ICCESReport
ESR2495
ICCES|(800)4236587|(562)6990543|www.icces.org Reissued04/2016
000 Thisreportissubjecttorenewal04/2017.


DIVISION:030000CONCRETE
SECTION:032100REINFORCINGSTEEL


REPORTHOLDER:

DAYTONSUPERIORCORPORATION

1125BYERSROAD

MIAMISBURG,OHIO45342



EVALUATIONSUBJECT:


BARLOCKCOUPLERLANDS/CASERIESSYSTEMSFOR
CONNECTINGSTEELREINFORCINGBARS

LookforthetrustedmarksofConformity!

2014RecipientofPrestigiousWesternStatesSeismicPolicyCouncil
(WSSPC)AwardinExcellence ASubsidiaryof

ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not
specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a
recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as
to any finding or other matter in this report, or as to any product covered by the report.

Copyright2016ICCEvaluationService,LLC.Allrightsreserved.
ICC-ES Evaluation Report ESR-2495
Reissued April 2016
This report is subject to renewal April 2017.

www.icc-es.org | (800) 423-6587 | (562) 699-0543 A Subsidiary of the International Code Council

DIVISION: 03 00 00CONCRETE 3.0 DESCRIPTION


Section: 03 21 00Reinforcing Steel
3.1 General:
REPORT HOLDER: The Bar-Lock Coupler L- and S/CA-series systems are
used to splice No. 4 through No. 14 deformed steel
DAYTON SUPERIOR CORPORATION reinforcing bars; the largest S/CA-series system is used to
1125 BYERS ROAD splice No. 18 deformed steel reinforcing bars. See Figure 1
MIAMISBURG, OHIO 45342 and Tables 1 and 2 for additional details.
3.2 Materials:
EVALUATION SUBJECT:
3.2.1 Couplers: The couplers are illustrated in Figure 1.
BAR-LOCK COUPLER L- AND S/CA- SERIES SYSTEMS L- and S/CA-series couplers consist of lock-shear bolts
FOR CONNECTING STEEL REINFORCING BARS threaded into the side of seamless, hot-rolled steel tubing.
The couplers have two serrated steel strips, the same
1.0 EVALUATION SCOPE length as the coupler, inside the tubing. The lock-shear
bolts have conical ends, designed to embed themselves
Compliance with the following codes: into the reinforcing bars. The heads of the lock-shear bolts

2012, 2009 and 2006 International Building Code (IBC) are configured to shear off when tightened to the
appropriate installation torque specified in Tables 1 and 2.
2012, 2009 and 2006 International Residential Code The bolts are manufactured from steel complying with
(IRC) ASTM A108 Grade AISI 41L40 or 4140. The couplers are
manufactured from steel having a minimum tensile
2013 Abu Dhabi International Building Code (ADIBC) strength of 100,000 psi (689 MPa) and conforming to a

The ADIBC is based on the 2009 IBC. 2009 IBC code sections referenced proprietary steel grade having chemical composition
in this report are the same sections in the ADIBC. values midway between those specified for ASTM A519
Property evaluated: Grades 1030 and 1035. The S/CA-series couplers are the
same as the L-series couplers, except the S/CA-series
Structural couplers are shorter in length and use fewer lock-shear
bolts.
2.0 USES
3.2.2 Reinforcing Steel Bars: The reinforcing steel bars
The Bar-Lock Couplers, L- and S/CA-series systems, are must be uncoated, deformed, steel complying with ASTM
used as mechanical splices of deformed steel reinforcing A615 Grade 60 or ASTM A706 Grade 60, specifications.
bars used in reinforced concrete construction. The L- and
S/CA- series systems comply with Section 12.14.3.2 of ACI 4.0 DESIGN AND INSTALLATION
318 (ACI 318 is referenced in IBC Section 1901.2) for use 4.1 General:
as tension and compression mechanical connections of
deformed steel reinforcing bars conforming to ASTM A615 The Bar-Lock Couplers, L- and S/CA-series systems must
Grade 60 or ASTM A706 Grade 60 and are for use where be designed and installed in accordance with the IBC and
Type 1 mechanical splices are specified by the IBC and this evaluation report. The splice locations must be
ACI 318. The L-series system also complies with the Type detailed on plans approved by the code official. All required
2 mechanical splice requirements of Section 21.1.6.1 of spacing and concrete protection (cover) described in the
ACI 318-11 for the 2012 IBC (Section 21.1.6.1 of ACI 2012 and 2009 IBC Table 721.1(1) [2006 IBC Table
318-08 for the 2009 IBC, and Section 21.2.6 of ACI 318-05 720.1.1(1)] and Sections 7.6 and 7.7 of ACI 318 must be
for the 2006 IBC) and are for use where Type 2 measured from the outside of the splice systems.
mechanical splices are specified by the IBC and ACI 318, 4.2 Installation:
except the system used to splice No. 18 bars is limited to
ASTM A615 Grade 60 bars. The first reinforcing bar must be inserted halfway into the
coupler, to the center pin, and the coupler must be held in
The Bar-Lock Couplers, L- and S/CA-series systems may place while the corresponding bolts are tightened in an
be used under the IRC when an engineered design is alternating pattern (e.g., 2-4-3-1 for a four-bolt coupler)
submitted in accordance with IRC Section R301.1.3. until each lock-shear bolt is medium-tight. The second bar

ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed
as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as
to any finding or other matter in this report, or as to any product covered by the report.
1000

Copyright 2016 ICC Evaluation Service, LLC. All rights reserved. Page 1 of 4
ESR-2495 | Most Widely Accepted and Trusted Page 2 of 4

is inserted and the lock-shear bolts must be tightened and axial forces in frame members, structural walls
following the same procedure. The lock-shear bolts must and coupling beams, with the Bar-Lock Coupler
then be tightened in a random, alternating pattern. At least systems, mill certificates of reinforcing bars must be
two passes of tightening each lock-shear bolt must be submitted to the code official as evidence that the
done before the lock-shear bolt heads are sheared off. steel reinforcing bars comply with ACI 318-08 Section
21.1.5.2.
4.3 Special Inspection:
5.5 Under the 2006 IBC, for structures regulated by
Special inspection is required in accordance with Section
Chapter 21 of ACI 318-05 (as required by 2006 IBC
1705 of the 2012 IBC (Section 1704 of the 2009 and 2006
Section 1908.1), to splice uncoated, deformed
IBC). The inspector's duties include verifying that the
reinforcing bars resisting earthquake-induced flexure
coupler is identified and installed in accordance with this
and axial forces in frame members and in structural
report, verifying grade and size of reinforcing bars, coupler
wall boundary elements, with the Bar-Lock Coupler
identification, position of coupler, rebar insertion length, the
systems, mill certificates of reinforcing bars must be
bolt tightening pattern and placement of rebar splices as
submitted to the code official as evidence that the
well as installation of coupler to rebars.
steel reinforcing bars comply with ACI 318-05 Section
5.0 CONDITION OF USE 21.2.5.
The Bar-Lock mechanical splice systems described in this 5.6 Special inspections must be provided in accordance
report comply with, or are suitable alternatives to what is with Section 4.3 of this report.
specified in, those codes listed in Section 1.0 of this report,
5.7 The minimum concrete cover must be in accordance
subject to the following conditions:
with the IBC, and must be measured from the outer
5.1 The splice systems must be installed in accordance surface of the coupler.
with the applicable code, the manufacturers
6.0 EVIDENCE SUBMITTED
instructions, and this report. In the case of a conflict
between the manufacturers published instructions Data in accordance with the Acceptance Criteria for
and this report, this report governs. Mechanical Connector Systems for Steel Reinforcing Bars
(AC133), dated December 2012.
5.2 Splice locations must comply with applicable code
requirements and be noted on plans approved by the 7.0 IDENTIFICATION
code official.
Each S/CA-series coupler is stamped with the coupler size
5.3 Under the 2012, for structures regulated by Chapter designation, the Series designation S, the production
21 of ACI 318-11 (as required by the 2012 IBC lot number, the Series designation CA, and the type
Section 1905.1), to splice uncoated, deformed designation Type 1. Each L- series coupler is stamped
reinforcing bars resisting earthquake-induced flexure, with the coupler size, the Series designation L, the
axial force, or both, in special moment frames, special production lot number, and the type designation Type 2.
structural walls, and all components of special Each bundle, pallet or skid of couplers has a shipping tag
structural walls including coupling beams and wall bearing the Bar-Lock Coupler Systems company name
piers, with the Bar-Lock Coupler systems, mill and address, the product designation and size, the
certificates of reinforcing bars must be submitted to production lot number, the installation instructions, and the
the code official as evidence that the steel reinforcing evaluation report number (ESR-2495).
bars comply with ACI 318-11 Section 21.1.5.2.
5.4 Under the 2009 IBC, for structures regulated by
Chapter 21 of ACI 318-08 (as required by 2009 IBC
Section 1908.1), to splice uncoated, deformed
reinforcing bars resisting earthquake-induced flexural
ESR-2495 | Most Widely Accepted and Trusted Page 3 of 4

TABLE 1L-SERIES COUPLER SPECIFICATIONS

COUPLER REINFORCING BAR COUPLER SPECIFICATIONS LOCK-SHEAR BOLT SPECIFICATIONS


SIZEAND Size Diameter Outside Length Weight Quantity Diameter Approximate
SERIES Range Diameter (inches) (lb.) (inch) Torque
2
DESIGNATION (inches) (inches) (lbf-ft)
1 1
4L-X No. 4 0.453 - 0.551 1.3 5.5 1.6 6 /2 40
1 1
5L-X No. 5 0.591 - 0.709 1.7 6.3 2.8 6 /2 80
1 1
6L-X No. 6 0.669 - 0.866 1.9 8.0 4.5 8 /2 80
1 1
7L-X No. 7 0.827 - 0.945 1.9 9.8 5.5 10 /2 80
1 5
8L-X No. 8 0.984 - 1.063 2.1 12.3 9.5 10 /8 180
1 3
9L-X No. 9 1.100 - 1.260 2.9 11.5 11.4 8 /4 280
1 3
10L-X No. 10 1.181 - 1.338 2.9 14.0 19.5 10 /4 410
1 3
11L-X No. 11 1.338 - 1.536 3.1 16.5 24.0 12 /4 410
1 3
14L-X No. 14 1.693 - 1.929 3.5 26.6 40.0 20 /4 410
For SI: 1 inch = 25.4 mm, 1 lb = 0.4536 kg, 1 lbf-ft = 1.356 Nm.
1
Where X denotes production lot number; see Section 7.0 for additional information.
2
Approximate torque values are for reference only. All bolts must be tightened in accordance with Section 4.2 of this report
until the heads are sheared off, regardless of applied torque.

TABLE 2S/CA-SERIES COUPLER SPECIFICATIONS

COUPLER REINFORCING BAR COUPLER SPECIFICATIONS LOCK-SHEAR BOLT SPECIFICATIONS


SIZE AND Size Diameter Outside Length Weight Quantity Diameter Approximate
SERIES Range Diameter (inches) (lb.) (inch) Torque
2
DESIGNATION (inches) (inches) (lbf-ft)
1 1
4S-X-CA No. 4 0.453 - 0.551 1.3 3.9 1.0 4 /2 40
1 1
5S-X-CA No. 5 0.591 - 0.709 1.7 4.5 1.8 4 /2 80
1 1
6S-X-CA No. 6 0.669 - 0.866 1.9 6.3 3.5 6 /2 80
1 1
7S-X-CA No. 7 0.827 - 0.945 1.9 8.0 4.1 8 /2 80
1 5
8S-X-CA No. 8 0.984 - 1.063 2.2 10.2 7.6 8 /8 180
1 3
9S-X-CA No. 9 1.100 - 1.260 2.9 9.0 11.4 6 /4 280
1 3
10S-X-CA No. 10 1.181 - 1.338 2.9 11.5 15.5 8 /4 350
1 3
11S-X-CA No. 11 1.338 - 1.536 3.1 14.0 20.5 10 /4 350
1 3
14S-X-CA No. 14 1.693 - 1.929 3.5 16.5 26.0 12 /4 350
1 3
18S-X-CA No. 18 2.165 - 2.480 4.3 27.1 60.0 20 /4 475
For SI: 1 inch = 25.4 mm, 1 lb = 0.4536 kg, 1 lbf-ft = 1.356 Nm.
1
Where X denotes production lot number; see Section 7.0 for additional information.
2
Approximate torque values are for reference only. All bolts must be tightened in accordance with Section 4.2 of this report
until the heads are sheared off, regardless of applied torque.
ESR-2495 | Most Widely Accepted and Trusted Page 4 of 4