Sie sind auf Seite 1von 17

ZNS Van Dam

Geveltechniek b.v.
Postbus 35 2980 AA
Benedenrijweg 186 2987 VB
RIDDERKERK, The Netherlands
Telefax: +31 (0)180-462785
Telefoon: +31 (0)180-441800
e-mail: info@znsvandam.s3c.nl
internet: www.van-dam.nl
Bankrekening nr 44 37 43 606
K.v.K. Breda nr. 230 34 672
BTW-nr. NL002826227B01

BY E-MAIL

M/s Gujarat Fluorochemicals Limited (GFL)


Plot No. 17, Sector 16A
Noida 201301, UP
India

Attention Mr. Rajeev Gupta

Ridderkerk, 23rd of January 2006

Dear Mr,

Re.: Dahej Chemical Complex in India


Fire- and Blast Doors
Our ref.: 160178 rev.01
Your ref.: 2090/1308/X011-BRDoor/Civ/036 dated 10 Jan 06

Further to your enquiry by email message of 10th of January we herewith have pleasure to
issue our proposal for the design, engineering and fabrication of the relevant Fire- and Blast
Doors accordingly.

All materials as proposed in our bid have been applied on many onshore and offshore locations
worldwide. Our blast resistant doors have also been applied on the Jamnagar industrial plants
in India to our clients satisfaction. We are therefore assured that the materials offered will meet
your requirements and the local environmental requirements.

Our input will enable you to value engineer the project to an optimum, and we would be more
than welcome to present our proposal in more detail if so requested.

For any queries, please do not hesitate to contact the undersigned.

Kind Regards

ZNS VAN DAM


GEVELTECHNIEK B.V.

Petra Dronk

Op alle opdrachten aan ons, op al onze offertes en op alle met ons gesloten overeenkomsten zijn van toepassing de Algemene leveringsvoorwaarden voor de Metaal- en
Elektrotechnische Industrie. Gedeponeerd ter Griffie van de Arrondissements Rechtbank te s-Gravenhage op 19 oktober 1998 onder nr. 119/1998.
Andersluidende voorwaarden worden nadrukkelijk van de hand gewezen.
Terms and conditions to the General conditions for the Metaal- en Elektronische Industrie apply on all orders to us, on all our bids and on all agreed contracts. These
conditions have been registered at the Arrondissements Rechtbank in The Hague on 19 October 1998 under no. 119/1998.
Other conditions are rejected emphatically.
DAHEJ , G UJARAT CHEMICAL COMPLEX Our ref. no. 16017 rev. 01
Blast & Fire Doors
CONTENTS

A. Technical Part - Description & Product Data Sheets


1. General
2. Doors

B. Commercial Part
1. Pricing Schedule
2. Conditions
3. Schedule of hourly rates

C. Programme

D. D1 Method Plan
1. Quality and Safety

D2 Notes to this proposal


1. Design / Engineering
2. Manufacturing
3. Packing / Transport

E. Company Info
1. Company structure
2. Reference list
DAHEJ , G UJARAT CHEMICAL COMPLEX Our ref. no. 16017 rev. 01
Blast & Fire Doors
A. TECHNICAL PART

A1 General

Enclosed short specifications and datasheets describe the doors offered. If and when
required we can provide examples of drawings, details and data produced for the
application of these doors in similar previous projects. These will outline the doors in
much practical detail.

The construction quoted is in compliance with the performance requirements from your
specification and as described in enclosed technical description. Our companys attitude
and image is one of progressiveness and improvement of our products and people.
Innovation is the essence of ZNS Van Dam and we constantly seek it. We have very
considerable experience in engineering design; it is our policy to invest heavily in R&D,
to finance product testing (usually by independent test-houses) and wherever necessary,
actively to involve Certifying Authorities.

In order to be able to judge the competitiveness of the proposal, it is important to note the
design philosophy behind our door designs. Basically the doors shall be considered as to
be mechanical equipment. Repair and maintenance costs for doors in operation can over
the doors lifetime add up to double its initial acquisition cost. Based on evaluations taken
place by several leading operators we can confirm that our door designs, although in some
cases perhaps with higher initial costs, will have quantifiable reduced maintenance costs.
Also the safety and comfort aspect of reduction of malfunction are important key points of
our door designs.

Please note that all our doors systems have been fully tested and do have the required type
approval certificates from Lloyds Register.
DAHEJ , G UJARAT CHEMICAL COMPLEX Our ref. no. 16017 rev. 01
Blast & Fire Doors
A. TECHNICAL PART

A2 Doors

The doors we offer are of our well established, Lloyds certified offshore range, pre-
assembled as complete units and provided with stainless steel heavy duty in-house made
hardware (ss 304). The construction and design of the doors will be as per our standard
certified and patented designs as indicated on attached datasheets. Doorleaves will be
spotwelded in order to prevent distortion of the doorleaves.

Special attention is given to the seals, which are tested for gas- and water tightness and to
the hardware that provides friction-free opening and closing.

We have noted the requirement for attachment of doors into concrete. We have indicated
in the pricing schedule optional items for providing the subframing requirement for proper
installation of our doors.
DAHEJ , G UJARAT CHEMICAL COMPLEX Our ref. no. 16017 rev. 01
Blast & Fire Doors
A. TECHNICAL PART

Single hinged external fire rated doors


Exterior 240 minutes smoke and fire rating regarding stability and integrity door, complete
with pre-drilled frame (no insulation requirements). Double doors have been actually
tested to 180 minutes according A-fire curve. We therefore can state that these single
hinged doors will achieve stability and integrity to 240 minutes.
Type: Gadam design 1 as per datasheet

Total 8 number:
Structural opening: H2150 x W1300 mm
Clear opening: H2010 x W1118 mm
Total 16 number:
Structural opening: H2150 x W1100 mm
Clear opening: H2010 x W918 mm

Material: mild steel


Conservation: blasted, primed and provided with coating system total 180 mu end
colour RAL7036 doorleaf and RAL9010 doorframe
Blast overpressure: 0.2812 bar

Including the following stainless steel heavy duty hardware:


3-point latch system
handles with shields
continuous hinge
compressed seals
doorcloser
cylinder lock with masterkey system
earthing
Optional item:
panic opening device

Enclosures:

Datasheets
DOORS AND HATCHES 1.
TECHNICAL DATA 1.7

GADAM TYPE 1.7.2

DESIGN 1 DOOR WITH TOUCHING SEAL A0 - A60 1.7.2.1

doorcloser

15
3 60

55
clear opening H1

opening in bulkhead H2
doorleaf H3
1050

55
60 3

15

H
right hinged as shown
left hinged opposite
(sit. 1, ref. data sheet 1.5.1)

opening in bulkhead W2

15 45 clear opening 90 W1 52 55 15

bulkhead and frame


P insulation as required
80

60 3 doorleaf W3 22 60

ZNS Van Dam Geveltechniek b.v.


P.O. Box 35 2980 AA Ridderkerk
Code nr. : 01G01
Phone: +31(0)180 44 18 00 Fax: +31(0)180 46 27 85 Date of issue : 16.10.2003
e-mail: info@vandam.s3c.nl internet: www.van-dam.nl Sheet : 1.7.2.1
DAHEJ , G UJARAT CHEMICAL COMPLEX Our ref. no. 16017 rev. 01
Blast & Fire Doors
C. PLANNING

C1 Preliminary planning indication see attached barchart.

Above mentioned is based on average man force and calculated total hours required.
However, we work out detailed planning in co-operation with your planning department
and effectively try to modify it accordingly.
ZNS VAN DAM BV ZNS Van Dam ref. 16017
P.O. Box 35
2980 AA Ridderkerk DAHEJ CHEMICAL COMPLEX INDIA
The Netherlands External Fire/Blast Doors

20 Feb '06 27 Feb '06 6 Mar '06 13 Mar '06 20 Mar '06 27 Mar '06 3 Apr '06 10 Apr '06 17 Apr '06 24 Apr '06 1 May '06 8 May '06
ID Task Name Week 1 Week 2 Week 3 Week 4 Week 5 Week 6 Week 7 Week 8 Week 9 Week 10 Week 11 Week 12
1 Contract Award
2 Design Engineering
3 Review and Approval
4 Shopdrawings
5 Procurement
6 Fabrication

Task Summary Rolled Up Progress

planning rev. 01 Split Rolled Up Task External Tasks


Date: Mon 23-1-06 Progress Rolled Up Split Project Summary

Milestone Rolled Up Milestone

rev. 01 Page 1
DAHEJ , G UJARAT CHEMICAL COMPLEX Our ref. no. 16017 rev. 01
Blast & Fire Doors
D. METHOD PLAN

D1 Method Plan

D1.1 Quality and Safety Information

Our quality system in accordance with ISO 9001 includes a documentation system.

Our Safety Management System has, as its foundation, such legislation as was
imposed by the Health and Safety at Work Act, 1974. All materials will be reported
in a COSHH listing and will be free from health hazards. Furthermore, all
installation of our materials can be done with standard tools. Also for this project a
project specific health and safety plan will be issued.

Further requirements have been included in recognition of the VCA Standard: this is
essentially a check-list introduced by an authoritative panel of industrial safety experts in
which, by way of interest, all Shell operations participate.

D2 Notes to this propsal

D2.1 Design / Engineering

All our design / engineering activities will take place at our offices in Ridderkerk, where
we have the latest CAD technology (Autocad 2000), and access to the internet for data
exchanges. Our prices do include for documents and drawings to be sent from review
approval 1 x.
Our Design Manager will attend design meetings with the projects design team.

D2.2 Manufacturing

Manufacturing of all components will take place at our factory works in Ridderkerk,
and with our panel manufacturer in Holland. All components will be packed into
containers for shipment to site, in accordance with the on-site installation sequence.
Fabrication locations are available in Ridderkerk, Holland / Bruno, Tsechia /
Sandefjord, Norway / Dubai, UAE.

D2.3 Packing / Transport

We have included for FOB Rotterdam harbour.


DAHEJ , G UJARAT CHEMICAL COMPLEX Our ref. no. 16017 rev. 01
Blast & Fire Doors
E. COMPANY INFO

E1 Company Structure

ZNS Van Dam has a long outstanding experience in the application of sheet metal
engineering in the building, offshore and shipbuilding industry. Van Dam was founded in
1906 and has since been active in all kinds of sheet metal work, mainly for architectural
industrial purposes. In the course of years van Dam built up a great expertise in the
areas of research and development, design, fabrication and installation.

This expertise is based on many years of experience in meeting the stringent


requirements of some of the worlds most exacting customers. For each individual case
unique solutions are found, which emphasises on major cost and weight savings within
the requirements of structural integrity, durability and safety considerations.

The applications are in:

1. Thin gauged metal load bearing constructions.

2. Sheet metal engineering for architectural building components.

3. Architectural metal cladding, walls, roofs, floors and doors.

The main functions available in our group are:

Research and Development

Design / Engineering

Project management

Manufacturing and installation

Installation supervision

Quality control
DAHEJ , G UJARAT CHEMICAL COMPLEX Our ref. no. 16017 rev. 01
Blast & Fire Doors
E. COMPANY INFO

Our company is part of the S3C holding company participating a.o. the companies Zuid
Nederlandse Staalbouw, Hollandia Kloos and Bailey.
DAHEJ , G UJARAT CHEMICAL COMPLEX Our ref. no. 16017 rev. 01
Blast & Fire Doors
E. COMPANY INFO

Project Organogram

Managing Director

Project Manager

Fabrication
Design Procurement Fabrication Installation
DAHEJ , G UJARAT CHEMICAL COMPLEX Our ref. no. 16017 rev. 01
Blast & Fire Doors
E. COMPANY INFO

E2 Reference list

Our company has a longstanding experience in the design, engineering, fabrication and
supply of heavy duty blast- and firewalls for the offshore industry. The attached
reference list will give you an overview of some of the largest of special projects we
carried out since the early eighties.
DAHEJ , G UJARAT CHEMICAL COMPLEX Our ref. no. 16017 rev. 01
Blast & Fire Doors
E. COMPANY INFO

COMPANY /PROJECT QTY DESCRIPTION COMPLE


-TED
Prefabricateds.s. and m.s. composite
BP Magnus 5000 m 1982
firewalls
m.s. lightweight internal and external
Statoil Statpipe RP 2/4S 2000 m 1984
firewalls
NAM AWG 2000 m m.s. external walls and doors 1985
British Gas Rough 800 m m.s. walls and doors 1985
Agip El Bouri 1000 m m.s. firewalls 1986
Petroland Zuidwal 800 m External walls and doors 1986
Pillips Tommeliten 610 m m.s. internal and external walls 1987
Esso Mosselbay 2500 m m.s. walls and doors 1989
Amoco Hod 500 m Walls and cladding 1990
Amoco Montrose 2500 m Cladding for L.Q. and doors 1990
Occcidental Saltire 2500 m Cladding for L.Q. and doors 1990
Placid L11 400 m External fire walls and doors 1990
NAM L5, L15 1500 m External fire walls and doors 1992
Shell Nelson L.Q. 3000 m External fire walls and doors 1992
NAM F3 1800 m External fire walls and doors 1993
Shell Galleon PN 550 m External fire walls and doors 1993
Wintershall L8-P 250 m External fire walls and doors 1993
Shell Brent A L.Q. 1000 m Replacement fire/blast walls 1994
Petroland K5A/K5D/K5P 2100 m External and internal fire walls 1994
Shell Barque PL 400 m External and internal fire walls 1994
Wintershall K13A 700 m External firewalls 1994
Placid K11 300 m External firewalls 1994
BP Clyde 1 X Automatic closing firewall 1995
Shell Cormorant A 1600 m m.s. external fire walls 1995
Maersk Tyra East 900 m External firewalls and doors 1995
Amoco P15D 200 m External firewalls and doors 1995
DAHEJ , G UJARAT CHEMICAL COMPLEX Our ref. no. 16017 rev. 01
Blast & Fire Doors
E. COMPANY INFO

COMPANY /PROJECT QTY DESCRIPTION COMPLE


-TED
BP Cleeton Compression 200 m External firewalls 1995
Amoco Valhall 200 m External blastwall 1995
External and internal firewalls and glazed
British Gas Armada 2900 m 1996
wall partitions
Wanadoo Wanadoo B 1100 m m.s. external and internal firewalls 1996
Phillips
Ekofisk 2/4J 2000 m m.s. internal acoustic firewalls 1996
Petroleum
Maersk Dan FF 2300 m m.s. fire and blastwalls and doors 1996
Elf Petroland K6 Compr. 2500 m m.s. firewalls and doors 1996
Elf Petroland K5 EN/C 350 m m.s. firewalls and doors 1996
Shell Curlew 450 m m.s. firewalls 1996
Elf Petroland K4 en K 400 m m.s. firewalls and doors 1998
NAM L9 Gas Development 1844 m Fire- and blastwalls and doors 1997
Amoco Valhall Module 200 m External blast- and firewalls and doors 1997
Esso Jotun WHP 1700 m External fire- and blastwalls and doors 1998
Total Sirri A&E 500 m External fire- and blastwalls and doors 1998
Elf Petroland K6GT 450 m Firewalls and doors 1998
Wintershall D15FA 2100 m External fire- and blastwalls 1999
Wintershall A6A 2700 m External fire- and blastwalls 2000
Elf Petroland K4BE 580 m m.s. firewalls and doors 2000
Wintershall L8P4 2700 m External fire- and blastwalls 2000
Clyde Petroleum Q4A 460 m External walls and doors 2000
Statfjord C 350 m External firewalls 2000
Sakhalin Wellbay 400 m External walls 2001
Elf Petroland K1A 570 m External firewalls and doors 2001
Esso Ringhorne Drilling 4320 m External firewalls and doors 2002
NAM NAM K81-LQ 1485 m External fire- and blastwalls 2001
Gaz de France G17 K9 K12 1200 m External fire- and blastwalls and doors 2002
Elf Petroland K5PK 650 m External fire- and blastwalls 2002
DAHEJ , G UJARAT CHEMICAL COMPLEX Our ref. no. 16017 rev. 01
Blast & Fire Doors
E. COMPANY INFO

COMPANY /PROJECT QTY DESCRIPTION COMPLE


-TED
Maersk Dan F 1200 m External fire- and blastwalls and doors 2002
Maersk Halfdan BA 650 m External fire- and blastwalls and doors 2002
NAM Compression Module 800 m External fire- and blastwalls and doors 2002
NAM K14 FB-1 250 m External firewalls 2002
AIOC Drilling Phase 1 1000 m External fire- and blastwalls and doors 2003
Clyde Q4C 2400 m External fire- and blastwalls and doors 2003
Conoco CMS 450 m External fire- and blastwalls and doors 2003
External and internal firewalls,
Sakhalin LUN-A & PAB 25000 m Ongoing
blastwalls, cladding and doors
External and internal firewalls,
Sakhalin Orlan 2000 m Ongoing
blastwalls, cladding and doors
Sakhalin Orlan 1100 m Internal walls and doors Ongoing
Siemens HSL Tunnels 116 pcs Fireblast escape doors Ongoing