Sie sind auf Seite 1von 7

GTP- 6

( To be filled in and signed by the tenderer)


SCHEDULE OF GAURANTEED TECHNICAL PARTICULARS FOR CONTROL AND
RELAY PANEL

A. CONTROL AND RELAY PANELS.


1. Make.
2. Type of sheet steel
3. Thickness of sheet steel
i. Front.
ii. Back.
iii. Sides.
4. Details of painting
5. Weight of each panel sections
6. Overall dimensions of each panel section
(height x width x depth ).
7. Total weight of all panels.
8. Space required for installation of
allpanels.
9. Details of tropicalization
10. Largest package for transport
i. Gross weight
ii. Overall dimensions.
B. CONTROL SWITCHES
1. Make .
2. Type
3. Type of handle.
4. No. of possible positions of the handle
with diagrams.
i. No. of contacts available in each
position.
ii. Maximum no. of contacts which can be
accommodated for each position.
5. Ratings of contacts
i. Voltage
ii. Make and carry current continuously.
iii. Make and carry current for 0.5
seconds.
iv. Break resistive load
v. Break inductive load with L/R 40 m.
seconds.
6. Whether locking arrangement provided.
7. Mounting details
8. Dimensions
9. Other information, if any.
C. SEMAPHORE INDICATORS
1. Make
2. Type
3. Diameter of the disc.
Operating voltage
4.
5. Burden.
D. INDICATING LAMPS (LED)
1. Make
2. Type
3. Ratings
i. Current
ii. Voltage
iii. Wattage

4. Color of lamp
5. Permissible voltage variation
6. Whether series resistance is provided , if
so
i. Ohmic Value
ii. Power loss
7. Life of lamp in burning hours
8. Other information ,if any.
E. PUSH BUTTONS
1. Make
2. Contact type momentary/maintained
3. Whether shrouding provided to prevent
inadvertent operation
4. Whether integral engraved
Inscription plates provided.
4. No. of NO/NC contacts.
F. ANNUNCIATION
1. Name and type
2. No. of windows
3. Dimensions of each window
4. No. of lamps per window
5. Auxiliary supply voltage
6. Power consumption
7. Details of auxiliary equipment such as
relays etc.
8. Required instantaneous making capacity
of initiating contacts.
9. Type of reset manual/self
10 Overall dimensions annunciators.
11. Particulars of wiring
12. Technical literature ENCLOSED ? YES/NO
13. Brief write-up of the scheme ENCLOSED? YES/NO
G. INDICATING METERS
1. Make and type
2. Type of movement
3. Type of mounting
4. Range
i. Rated current
ii. Rated voltage drop
5. CT ratio
6. PT ratio
7. Details of shunt, if any
i. Rated current
ii. Rated voltage drop
8. Accuracy class
9. Total deflection angle
10. Total scale length
11. Overall dimensions
12. Reference condition of influencing
quantities.
13. Limits of applications for influencing
quantities.
14. Limit of error for variation of each of the
influencing quantities.
15. Burden
i. Current coil
ii. Voltage coil
16. Short time rating
i. Current coil
ii. Voltage coil
iii. Time
17. Other details.
18. Detailed literature ENCLOSED ? YES/NO
H. ELECTRONIC DIGITAL ENERGY METERS
1. Make
2. Type of measurement
3. Measuring range
4. CT ratio
5. PT ratio
6. Current coil rating
7. Voltage coil rating
8. Accuracy
9. PULSE/KWH
10. VA burden of current coil
11. VA burden of potential coil
12. Limits of error at UPF and
i. Rated current
ii. 125% & 25% of rated current
iii. 10% of rated current
13. limits of errors at 0.5 PF(lag) and
i. Rated current
ii. 125% & 25% of rated current
iii. 10% of rated current
14. Continuous overload rating of Current coil
i. For thermal limit
ii. For accuracy limit
15. Short time overload rating of current coil
i. Current
ii. Time
16. Continuous over voltage rating of
potential coil.
17. Whether temper recording facility
provided
18. Standard to which it conforms.
19. Mounting details
20. Testing facilities and other details , if
any.
I. OVER CURRENT RELAYS
1. Make
2. Type
3. Current coil rating
4. Potential coil rating
5. Polarization
6. Tap range
7. VA burden
i. Highest tap
ii. Lowest tap
8. Power consumption
Highest tap
Lowest tap
9. Time of operation of maximum time dial
setting at
5 times tap setting current
10 times tap setting current.
10. Type of characteristics
11. Trip contacts rating (amps)
12. Whether seal in contacts provided
13. Technical literature ENCLOSED ? YES/NO
J. DIFFERNTIAL RELAYS
1. Make
2. Type
3. Current coil rating
4. Tap range
5. Maximum VA burden
i. Operating coil.
Ii Restraining coil.
6. Is the scope setting available
7. Harmonic restraint provided or not
8. Range of HT/LT ratios over which the
relay can be used.
9. Operating time.
10. Trip contact rating
11. Whether seal in contact provided or not.

12. Technical literature ENCLOSED ? YES/NO


K. OVER FLUXING RELAYS
1. Make
2. Type
3. Voltage rating
4. Operating indicator
5. Operation indicator
6. Burden
i. A/C burden
ii D/C burden
7. Type and no. of time auxiliary elements.
8. Type and no. of adjustable time auxiliary
element.
9. Type of insulation.
10. Requirement for impulse voltage.
11. Requirement for high frequency
interference
12 Type of casting
13. Type of mounting
14. Detailed literature ENCLOSED? YES/NO
15. Any other details.
L. OVER VOLTAGE RELAYS
1. Make
2. Type
3. Voltage rating
4. Minimum operating voltage
5. Settings
6. Operating time
7. Thermal rating
i. AC supply voltage
ii. Frequency
iii. DC supply

8. Number and type of contacts


9. Contact rating
10. Type of insulation
11. Impulse voltage
12. High frequency interference
13. Type of casing
14. Type of mounting
15. Detailed literature ENCLOSED? YES/NO
16. Any other details
M. EARTH FAULT RELAY
1. Make
2. Type
3. Voltage rating
4. Minimum operating voltage
5. Settings
6. Operating time
7. Thermal rating
i. AC supply voltage
ii. Frequency
iii. DC supply
8. Number and type of contacts
9. Contact rating
10. Type of insulation
11. Impulse voltage
12. High frequency interference
13. Type of casing
14. Type of mounting
15. Detailed literature ENCLOSED ? YES/NO
16. Any other details
N. SENSITIVE EARTH FAULT RELAY
1. Make
2. Type
3. Voltage rating
4. Minimum operating voltage
5. Settings
6. Operating time
7. Thermal rating
i. AC supply voltage
ii. Frequency
iii. DC supply
8. Number and type of contacts
9. Contact rating
10. Type of insulation
11. Impulse voltage
12. High frequency interference
13. Type of casing
14. Type of mounting
15. Detailed literature ENCLOSED ? YES/NO
16. Any other details
O. TRIP CIRCUIT SUPERVISION RELAYS
1. Make
2. Type
3. Nominal voltage
4. Permissible variation in voltage
5. Operating time
6. Burdens (DC)
i. trip supply (max.watts)
ii. alarm supply (max. volts)
7. Thermal rating
8. Operation indicators
9. Contacts
10 Contacts ratings
i. Make and carry AC DC
continuously
ii. Make and carry for
three sec.
iii. Break
11. Insulation
12. Type of casing
13. Type of mounting
14. Detailed literature ENCLOSED ? YES/NO
15. Any other details.
P. AUXILIARY AND TRIP RELAYS
1. Make
2. Type
3. Nominal voltage
4. Permissible variation in voltage
5. Nominal current (in case of current
Operated relay)
6. Permissible variation in current
7. Contacts, hand reset/self reset
8. No. of pair of contacts
i. Make contacts
ii. Break contacts
9. Speed of operation of relay
10. Pick up/drop off voltage
11. Resetting time.
12. Burden of relay
13. Contact rating
i. Make and carry continuous
ii. Make and carry for 0.5 seconds.
iii. Break
a) -resistive load
b) -inductive load with 40 m.sec.
time constant.
14. Type of casing and available no. of
terminals
15. Type of mounting
16. Detailed literature ENCLOSED ? YES/NO
Q. AUXILIARY C.T.s AND V.T.s
1. Make
2. Ratio
3. Type
4. Rated output VA
5. Class of accuracy
6. Short time rating
i. Current
ii. Voltage
7. Knee point voltage for class PS
8. Excitation current for class PS
i. KPV
ii. 50% KPV
9. Internal impedance of
i. primary
ii. secondary
10. Temperature rise
11. Mounting details
12. Overall dimensions
13. Any other details

Date
Place
Signatu
re
Name
Status
Whether authorized attorney
of the tendering company
Name of the tendering
Company