These vials
should be cleaned properly before filling. Automatic vial washing machines are used to
clean but the process of cleaning of the vials should be validated. The efficiency of
these machines is verified by following tests.
Procedure: About 3000 vials of selected size are loaded on the feed belt and vial
washing machine is operated as per the standard operating procedure. Place the spiked
vials marked with permanent marker in between the other vials while machine is
running. These vials should be placed at the initial, middle and end of the washing
session. Collect the marked vials after washing and store properly to avoid the other
contamination from environment. These spiked vials are analysed separately. It should
be done three times for each vial size.
Acceptance Criteria:
1. Sodium chloride content should be absent in any of the spiked vial.
2. Vials should be free from foreign particle & fibers on visual inspection. 10 particles
should not be more than 25 and 25 particles should not be more than 3.
3. Vials should comply endotoxin limit i.e 0.25 EU/vial.