Rev: 2.2015
Fiberglass Tanks
Process Vessels
Scrubbers
A UL
S C US
M
E LISTED
RTP
Composites USA
A Critical Process Systems Group Company
Composites USA
A Critical Process Systems Group Company
V-001 1
Style No.: Sheet:
Fitting: Index
A ASME RTP-1 Certified Fiberglass Tanks & Process Vessels Standards
S
M Underwriters C UL
US
E
Laboratories
RTP Listed LISTED
1 V-000 Index
2 V-001 Fitting Style Sheet
Nozzles:
3 V-501 Penetrating Stand-off Nozzle 52 V-765 Electric Heat Panels
4 V-505 Flush Stand-off Nozzle 53 V-770 Internal (Fixed) Coils
5 V-510 Double Sided Stand-off Nozzle 54 V-775 Flanged (Removable) Insert Coils
6 V-515 Pad Flange Nozzle 55 V-780 Double Wall Containment Tank Design
7 V-520 Flush Drain Nozzle 56 V-785 Integral Leak Detection Systems
8 V-525 Full Drain Nozzle Lugs, Supports & Guying:
9 V-530 Van Stone Style Nozzle 57 V-800 Flush Bottom "L" Hold Down Lugs
10 V-535 Sanitary Connection Nozzle 58 V-805 Side Wall Shear Ledge
11 V-540 45 Siphon Nozzle 59 V-810 Side Wall Chair Support Lugs
12 V-545 90 Siphon Nozzle 60 V-815 Universal Lift & Hold Down Lugs
13 V-550 Cone Gussets 61 V-820 Half Round Lift Lugs
14 V-555 Plate Gussets 62 V-825 Drilled Plate Lift Lugs
Vents: 63 V-830 Universal Mounting Clip
15 V-560 "V" Vents 64 V-835 "T" Bracket Mount
16 V-565 Gooseneck or "U" Vents 65 V-840 Guy Lug
17 V-570 Mushroom Vents 66 V-845 Guy Ring
18 V-575 Flanged Nozzle (Pipe Away) Vents Ladders & Platforms:
Threaded Connections: 67 V-850 Ladder Clips
19 V-580 Threaded Half Couplings 68 V-855 Platform Clips
20 V-585 Threaded Full Couplings 69 V-860 Ladders
Manways & Access Ports: 70 V-865 Ladders with Cages
71 V-870 Top Access Platforms
21 V-600 Flanged & Bolted Stand-off Manways 72 V-875 Intermediate Level Platforms
22 V-605 Rectangular Flanged & Bolted Manways 73 V-880 Top Guard Rail Systems
23 V-610 Flush Hinged Manways 74 V-885 Full Top Platforms
24 V-615 Loose Cap Manways
25 V-620 Flanged & Bolted Flush Cover Manways Tower Internals:
26 V-625 Hand Access Ports 75 V-900 Support Rings
Fill, Overflow & Cleaning: 76 V-905 Wall Wipers
77 V-910 Support Grating
27 V-640 Fill Line 78 V-915 Support Trays
28 V-643 Overflow Line 79 V-920 Flow Distributors - Weir & Trough
29 V-645 Dip Pipe - Fixed 80 V-925 Flow Redistributors
30 V-647 Dip Pipe - Removable
31 V-650 Clean in Place (CIP) Fittings Vessel Bottoms & Supports:
32 V-655 Spray Lance 81 VB-1000 Flat Bottom
View Ports & Level Gages: 82 VB-1005 Flat Bottom with Internal Slope
83 VB-1010 Flat Bottom with External Slope
33 V-660 View Port with Clear Bolt-on Cover 84 VB-1030 Dish Bottom
34 V-665 View Port with Glass Window Bolt-on Cover 85 VB-1040 Cone Bottom with 90 Included Angle
35 V-670 Illuminated View Port 86 VB-1045 Cone Bottom with 135 Included Angle
36 V-675 Full Light Port 87 VB-1050 Pipe Legs
37 V-680 Gage Strip 88 VB-1055 Angle Legs
38 V-690 Level Stand-off Gages 89 VB-1060 Skirt Support
Baffles & Agitator Supports: 90 VB-1065 Integral Stand
39 V-700 Wedge Baffles with Stand-off 91 VB-1070 Loose Stand
40 V-705 Wedge Baffles without Stand-off 92 VB-1075 Saddle Supports (for Horizontal Vessels)
41 V-710 Plate Baffles with Stand-off Vessel Tops:
42 V-715 Plate Baffles without Stand-off 93 VT-1100 Flat Welded Top
43 V-720 Vortex Breaker 94 VT-1105 Flat Welded Top with Hinged Split
44 V-725 Overflow Baffle 95 VT-1110 Flat Flanged Top
45 V-730 Top Bridge Agitator Mount in Steel 96 VT-1115 Flat Flanged Top with Hinged Split
46 V-735 Top Bridge Agitator Mount in Fiberglass 97 VT-1120 Loose Flat Cover
47 V-740 Top Head Flange Mount for Agitator 98 VT-1125 Loose Flat Cover with Hinged Split
48 V-745 Side Entry Flange Mount for Agitator 99 VT-1130 Dished Welded Top
49 V-750 Top Side Bracket for Agitator 100 VT-1135 Dished Flanged Top
50 V-755 Agitator Shaft Gland Collar 101 VT-1140 Cone Top with 90 Included Angle
Insulation, Heating, Cooling & Dual Wall: 102 VT-1145 Cone Top with 135 Included Angle
51 V-760 Insulation & Insulation Jacket 103 VT-1150 Hemispherical Heads (for Horizontal Vessels)
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 1 of 103
Composites USA
A Critical Process Systems Group Company
V-002 2
Style No.: Sheet:
Vents:
V-560 / V-575
Vessel Tops:
VT-1100 / VT-1150
Tower Internals:
V-900 / V-925
Threaded Connections:
V-580 / V-585
Nozzles:
V-501 / V-555
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 2 of 103
Composites USA
A Critical Process Systems Group Company
V-501 3
Style No.: Sheet:
STANDARD TYPE NOZZLE SCHEDULE 150# DRILLING PER ASME RTP-1 ( ALL DIMENSIONS IN INCHES )
STD 50 PSI
PIPE I.D. FLG O.D. FLG B.C. NO. OF HOLES ti dr
HOLE DIA. T (MIN.) tn
1 4-3/4 3-1/8 4 5/8 1/2 3/16 V.3m 7
1-1/2 5-1/2 3-7/8 4 5/8 1/2 3/16 V.3m 7.5
2 6 4-3/4 4 3/4 5/8 3/16 V.3m 8
3 7-1/2 6 4 3/4 5/8 3/16 V.3m 9
4 9 7-1/2 8 3/4 13/16 3/16 V.3m 10
6 11 9-1/2 8 7/8 15/16 3/16 V.3m 12
8 13-1/2 11-3/4 8 7/8 1-1/8 3/16 V.3m 16
10 16 14-1/4 12 1 1-1/4 3/16 V.3m 20
12 19 17 12 1 1-7/16 3/16 V.3m 24
14 21 18-3/4 12 1-1/8 1-1/16 3/16 V.3m 28
16 23-1/2 21-1/4 16 1-1/8 1-9/16 3/16 V.3m 32
18 25 22-3/4 16 1-1/4 1-5/8 3/16 V.3m 36
20 27-1/2 25 20 1-1/4 1-13/16 3/16 V.3m 40
24 32 29-1/2 20 1-3/8 2-1/8 7/16 V.3m 48
hi
ho
ti
I.D. B.C. O.D. dr
tn
to
ti T
ts
ho
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 3 of 103
Composites USA
A Critical Process Systems Group Company
V-505 4
Style No.: Sheet:
STANDARD TYPE NOZZLE SCHEDULE 150# DRILLING PER ASME RTP-1 ( ALL DIMENSIONS IN INCHES )
STD 50 PSI
PIPE I.D. FLG O.D. FLG B.C. NO. OF HOLES ti dr
HOLE DIA. T (MIN.) tn
1 4-3/4 3-1/8 4 5/8 1/2 3/16 V.3m 7
1-1/2 5-1/2 3-7/8 4 5/8 1/2 3/16 V.3m 7.5
2 6 4-3/4 4 3/4 5/8 3/16 V.3m 8
3 7-1/2 6 4 3/4 5/8 3/16 V.3m 9
4 9 7-1/2 8 3/4 13/16 3/16 V.3m 10
6 11 9-1/2 8 7/8 15/16 3/16 V.3m 12
8 13-1/2 11-3/4 8 7/8 1-1/8 3/16 V.3m 16
10 16 14-1/4 12 1 1-1/4 3/16 V.3m 20
12 19 17 12 1 1-7/16 3/16 V.3m 24
14 21 18-3/4 12 1-1/8 1-1/16 3/16 V.3m 28
16 23-1/2 21-1/4 16 1-1/8 1-9/16 3/16 V.3m 32
18 25 22-3/4 16 1-1/4 1-5/8 3/16 V.3m 36
20 27-1/2 25 20 1-1/4 1-13/16 3/16 V.3m 40
24 32 29-1/2 20 1-3/8 2-1/8 7/16 V.3m 48
6" OR AS SPECIFIED tr = ts
to = ts or .26" minimum
tr ho = hi = 1.5" ts < 3/8"
ho = hi = 2" ts < 1/2"
ho = hi = 3" ts < 3/4"
ho
hi
I.D. B.C. O.D. dr
tn
to
ti T
ts
ho
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 4 of 103
Composites USA
A Critical Process Systems Group Company
V-510 5
Style No.: Sheet:
STANDARD TYPE NOZZLE SCHEDULE 150# DRILLING PER ASME RTP-1 ( ALL DIMENSIONS IN INCHES )
STD 50 PSI
PIPE I.D. FLG O.D. FLG B.C. NO. OF HOLES ti dr
HOLE DIA. T (MIN.) tn
1 4-3/4 3-1/8 4 5/8 1/2 3/16 V.3m 7
1-1/2 5-1/2 3-7/8 4 5/8 1/2 3/16 V.3m 7.5
2 6 4-3/4 4 3/4 5/8 3/16 V.3m 8
3 7-1/2 6 4 3/4 5/8 3/16 V.3m 9
4 9 7-1/2 8 3/4 13/16 3/16 V.3m 10
6 11 9-1/2 8 7/8 15/16 3/16 V.3m 12
8 13-1/2 11-3/4 8 7/8 1-1/8 3/16 V.3m 16
10 16 14-1/4 12 1 1-1/4 3/16 V.3m 20
12 19 17 12 1 1-7/16 3/16 V.3m 24
14 21 18-3/4 12 1-1/8 1-1/16 3/16 V.3m 28
16 23-1/2 21-1/4 16 1-1/8 1-9/16 3/16 V.3m 32
18 25 22-3/4 16 1-1/4 1-5/8 3/16 V.3m 36
20 27-1/2 25 20 1-1/4 1-13/16 3/16 V.3m 40
24 32 29-1/2 20 1-3/8 2-1/8 7/16 V.3m 48
hi
tn ho
ti
I.D. B.C. O.D. dr
to
JOINT
T T
ti
ts
ho
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 5 of 103
Composites USA
A Critical Process Systems Group Company
V-515 6
Style No.: Sheet:
STANDARD TYPE NOZZLE SCHEDULE 150# DRILLING PER ASME RTP-1 ( ALL DIMENSIONS IN INCHES )
STD 50 PSI
PIPE I.D. FLG O.D. FLG B.C. NO. OF HOLES ti
H (THREADS) T
1 4-3/4 3-1/8 4 5/8-11UNC 1-1/4 V.3m
1-1/2 5-1/2 3-7/8 4 5/8-UNC 1-1/4 V.3m
2 6 4-3/4 4 3/4-UNC 1-1/2 V.3m
3 7-1/2 6 4 3/4-UNC 1-1/2 V.3m
4 9 7-1/2 8 3/4-UNC 1-1/2 V.3m
6 11 9-1/2 8 7/8-9UNC 1-3/4 V.3m
8 13-1/2 11-3/4 8 7/8-9UNC 1-3/4 V.3m
10 16 14-1/4 12 1-8UNC 2 V.3m
12 19 17 12 1-8UNC 2 V.3m
14 21 18-3/4 12 1-1/8-7UNC 2-1/4 V.3m
tn
1
H ( STN. STL. HELICAL INSERTS )
1
ti
3" MIN.
3"
T
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 6 of 103
Composites USA
A Critical Process Systems Group Company
V-520 7
Style No.: Sheet:
STANDARD TYPE NOZZLE SCHEDULE 150# DRILLING PER ASME RTP-1 ( ALL DIMENSIONS IN INCHES )
STD 50 PSI
PIPE I.D. FLG O.D. FLG B.C. NO. OF HOLES ti dr
HOLE DIA. T (MIN.) tn
1 4-3/4 3-1/8 4 5/8 1/2 3/16 V.3m 7
1-1/2 5-1/2 3-7/8 4 5/8 1/2 3/16 V.3m 7.5
2 6 4-3/4 4 3/4 5/8 3/16 V.3m 8
3 7-1/2 6 4 3/4 5/8 3/16 V.3m 9
4 9 7-1/2 8 3/4 13/16 3/16 V.3m 10
6 11 9-1/2 8 7/8 15/16 3/16 V.3m 12
8 13-1/2 11-3/4 8 7/8 1-1/8 3/16 V.3m 16
tr = ts
to = ts or .26" minimum
ho = hi = 1.5" ts < 3/8"
ti ho = hi = 2" ts < 1/2"
ho = hi = 3" ts < 3/4"
dr
1" 6 OR AS
SPECIFIED
ti
TANK
BTM. dr / 2
ti
tn
dr / 2 2"
T
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 7 of 103
Composites USA
A Critical Process Systems Group Company
V-525 8
Style No.: Sheet:
tr = ts
ti to = ts or .26" minimum
ho = hi = 1.5" ts < 3/8"
ho = hi = 2" ts < 1/2"
ho = hi = 3" ts < 3/4"
dr
1" 6 OR AS
SPECIFIED
ti
TANK
BTM.
dr / 2
tn
45
2" 2"
T
dr / 2
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 8 of 103
Composites USA
A Critical Process Systems Group Company
V-530 9
Style No.: Sheet:
tr = ts
2" MIN 6" OR AS SPECIFIED to = ts or .26" minimum
ho = hi = 1.5" ts < 3/8"
tr ho = hi = 2" ts < 1/2"
ho = hi = 3" ts < 3/4"
T2
hi
ho
ti
I.D. O.D. B.C. O.D. dr
tn
to
T1
ts
ho
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 9 of 103
Composites USA
A Critical Process Systems Group Company
V-535 10
Style No.: Sheet:
FERRULE MATERIAL
OF CONSTRUCTION
STAINLESS STEEL
FRP
STOP FOR
FERRULE
O.D. "A"
FERRULE
INSIDE TANK
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 10 of 103
V-540 11
Style No.: Sheet:
STANDARD TYPE NOZZLE SCHEDULE 150# DRILLING PER ASME RTP-1 ( ALL DIMENSIONS IN INCHES )
STD 50 PSI
PIPE I.D. FLG O.D. FLG B.C. NO. OF HOLES ti dr
HOLE DIA. T (MIN.) tn
1 4-3/4 3-1/8 4 5/8 1/2 3/16 V.3m 7
1-1/2 5-1/2 3-7/8 4 5/8 1/2 3/16 V.3m 7.5
2 6 4-3/4 4 3/4 5/8 3/16 V.3m 8
3 7-1/2 6 4 3/4 5/8 3/16 V.3m 9
4 9 7-1/2 8 3/4 13/16 3/16 V.3m 10
6 11 9-1/2 8 7/8 15/16 3/16 V.3m 12
8 13-1/2 11-3/4 8 7/8 1-1/8 3/16 V.3m 16
tr = ts
ts 6 OR AS to = ts or .26" minimum
SPECIFIED ho = hi = 1.5" ts < 3/8"
ho = hi = 2" ts < 1/2"
ho = hi = 3" ts < 3/4"
tr
22-1/22
ti
45 to
1"
2" T
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 11 of 103
Composites USA
A Critical Process Systems Group Company
V-545 12
Style No.: Sheet:
STANDARD TYPE NOZZLE SCHEDULE 150# DRILLING PER ASME RTP-1 ( ALL DIMENSIONS IN INCHES )
STD 50 PSI
PIPE I.D. FLG O.D. FLG B.C. NO. OF HOLES ti dr
HOLE DIA. T (MIN.) tn
1 4-3/4 3-1/8 4 5/8 1/2 3/16 V.3m 7
1-1/2 5-1/2 3-7/8 4 5/8 1/2 3/16 V.3m 7.5
2 6 4-3/4 4 3/4 5/8 3/16 V.3m 8
3 7-1/2 6 4 3/4 5/8 3/16 V.3m 9
4 9 7-1/2 8 3/4 13/16 3/16 V.3m 10
6 11 9-1/2 8 7/8 15/16 3/16 V.3m 12
8 13-1/2 11-3/4 8 7/8 1-1/8 3/16 V.3m 16
ts 6 OR AS
tr = ts
SPECIFIED to = ts or .26" minimum
ho = hi = 1.5" ts < 3/8"
ho = hi = 2" ts < 1/2"
ho = hi = 3" ts < 3/4"
tr
LONG ti
RADIUS
ELBOW
to
to
2" T
tn
1"
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 12 of 103
Composites USA
A Critical Process Systems Group Company
V-550 13
Style No.: Sheet:
3/16" THK.
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 13 of 103
Composites USA
A Critical Process Systems Group Company
V-555 14
Style No.: Sheet:
60
1/4" THK.
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 14 of 103
Composites USA
A Critical Process Systems Group Company
V-560 15
Style No.: Sheet:
STANDARD FITTINGS
( ALL DIMENSIONS IN INCHES )
I.D. A B C T
2 11-1/8 5-1/2 3-3/4 1/4
3 12-3/4 6-3/8 3-3/4 1/4
4 14-1/2 7-1/4 3-3/4 1/4
6 18 9 3-3/4 1/4
8 21-1/2 10-3/4 3-3/4 1/4
10 25 12-1/2 3-3/4 1/4
12 28 14 3-3/4 1/4
14 31-3/4 15-7/8 3-3/4 5/16
60
B
C
OPTIONAL SCREEN
I.D. W/ STN. STL. CLAMP
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 15 of 103
Composites USA
A Critical Process Systems Group Company
V-565 16
Style No.: Sheet:
STANDARD FITTINGS
( ALL DIMENSIONS IN INCHES )
I.D. A B C T (MIN.)
2 8 6 12-3/16 1/4
3 8 9 14-3/16 1/4
4 6 12 16-1/4 1/4
6 6 18 18-1/4 1/4
8 6 24 22-5/16 1/4
10 6 30 26-5/16 1/4
12 6 36 30-5/16 1/4
14 6 42 34-5/16 5/16
OPTIONAL SCREEN
W/STN. STL. CLAMP
A
I.D.
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 16 of 103
Composites USA
A Critical Process Systems Group Company
V-570 17
Style No.: Sheet:
STANDARD FITTINGS
( ALL DIMENSIONS IN INCHES )
I.D. A B C D QTY & WIDTH T
2 4 8 2 (2) x 1" 1/4
3 6 8-1/2 2-1/2 (2) x 1" 1/4
4 8 8-3/4 2-3/4 (2) x 1" 1/4
6 12 9-1/2 3-1/2 (2) x 2" 1/4
8 16 10-1/4 4-1/4 (4) x 2" 1/4
10 20 10-3/4 4-3/4 (4) x 2" 1/4
12 24 11-1/2 5-1/2 (4) x 2" 1/4
14 28 12-1/4 6-1/4 (4) x 2" 5/16
6"
T I.D.
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 17 of 103
Composites USA
A Critical Process Systems Group Company
V-575 18
Style No.: Sheet:
STANDARD TYPE NOZZLE SCHEDULE 150# DRILLING PER ASME RTP-1 ( ALL DIMENSIONS IN INCHES )
STD 50 PSI
PIPE I.D. FLG O.D. FLG B.C. NO. OF HOLES ti dr
HOLE DIA. T (MIN.) tn
1 4-3/4 3-1/8 4 5/8 1/2 3/16 V.3m 7
1-1/2 5-1/2 3-7/8 4 5/8 1/2 3/16 V.3m 7.5
2 6 4-3/4 4 3/4 5/8 1/4 V.3m 8
3 7-1/2 6 4 3/4 5/8 1/4 V.3m 9
4 9 7-1/2 8 3/4 13/16 1/4 V.3m 10
6 11 9-1/2 8 7/8 15/16 1/4 V.3m 12
8 13-1/2 11-3/4 8 7/8 1-1/8 1/4 V.3m 16
10 16 14-1/4 12 1 1-1/4 1/4 V.3m 20
12 19 17 12 1 1-7/16 1/4 V.3m 24
tr = ts
to = ts or .26" minimum
ho = hi = 1.5" ts < 3/8"
ho = hi = 2" ts < 1/2"
ho = hi = 3" ts < 3/4"
GUSSET AS REQUIRED
6" UNLESS
PER NOZZLE SPECS
OTHERWISE SPECIFIED
ti
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 18 of 103
Composites USA
A Critical Process Systems Group Company
V-580 19
Style No.: Sheet:
MATERIALS OF CONSTRUCTION
FRP STANDARD
SS, PVC, CPVC OPTIONAL
I.D. A
INSIDE TANK
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 19 of 103
Composites USA
A Critical Process Systems Group Company
V-585 20
Style No.: Sheet:
STANDARD FITTINGS
( ALL DIMENSIONS IN INCHES )
I.D. A B
3/4 6 4-1/2
1 7 4-1/2
B 1-1/2 7-1/2 4-1/2
2 8 4-1/2
2-1/2 8-1/2 4-1/2
3 9 4-1/2
4 10 4-1/2
6 12 4-1/2
MATERIALS OF CONSTRUCTION
FRP STANDARD
SS, PVC, CPVC OPTIONAL
I.D. A
INSIDE TANK
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 20 of 103
Composites USA
A Critical Process Systems Group Company
V-600 21
Style No.: Sheet:
2"
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 21 of 103
Composites USA
A Critical Process Systems Group Company
V-605 22
Style No.: Sheet:
DESCRIPTION OPTIONAL
STANDARD SUPPLY MATERIAL NOTES
INCLUDED
BOLTS PLATED STEEL
GASKETS NEOPRENE
HANDLES NO
DAVITS NO
SEE NOZZLE DRAWING V-501 FOR
INSTALLATION DETAILS L1
T T L
W1 W
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 22 of 103
Composites USA
A Critical Process Systems Group Company
V-610 23
Style No.: Sheet:
X X
10" Y 10"
2"
1-1/2" 1/2"
3"
DRILL FOR
3/8" DIA. BOLTS
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 23 of 103
Composites USA
A Critical Process Systems Group Company
V-615 24
Style No.: Sheet:
COVER I.D.
(ALL DIMENSIONS IN INCHES)
I.D. F (MIN) tn tc NOTES
18 19 1/4 1/4
20 21 1/4 1/4
22 23 1/4 1/4
24 25 1/4 1/4
30 31 5/16 5/16
6"
6"
FRP HANDLE
2"
tc tn
I.D.
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 24 of 103
Composites USA
A Critical Process Systems Group Company
V-620 25
Style No.: Sheet:
T T
A
SEE NOZZLE DRAWING
V-501 FOR INSTALLATION
DETAILS
A
2"
I.D. B.C. O.D.
3" 3"
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 25 of 103
Composites USA
A Critical Process Systems Group Company
V-625 26
Style No.: Sheet:
2" MIN
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 26 of 103
Composites USA
A Critical Process Systems Group Company
V-640 27
Style No.: Sheet:
SIZE STANDOFF LENGTH PIPE MATERIALS BRACKET BRACKET "U" BOLT MATL.
"D" "A" "B" OF CONSTRUCTION STYLE NUMBER OF CONSTRUCTION
D A
B
GUIDE AS REQUIRED,
CLAMP WITH "U" BOLTS
OPTIONAL VALVE
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 27 of 103
Composites USA
A Critical Process Systems Group Company
V-643 28
Style No.: Sheet:
SIZE STANDOFF LENGTH PIPE MATERIALS BRACKET BRACKET "U" BOLT MATL.
"D" "A" "B" OF CONSTRUCTION STYLE NUMBER OF CONSTRUCTION
GUIDE AS REQUIRED,
CLAMP WITH "U" BOLTS
12" TYP D
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 28 of 103
Composites USA
A Critical Process Systems Group Company
V-645 29
Style No.: Sheet:
STANDARD TYPE NOZZLE SCHEDULE 150# DRILLING PER ASME RTP-1 ( ALL DIMENSIONS IN INCHES )
STD 50 PSI
PIPE I.D. FLG O.D. FLG B.C. NO. OF HOLES ti dr
HOLE DIA. T (MIN.) tn
1 4-3/4 3-1/8 4 5/8 1/2 3/16 V.3m 7
1-1/2 5-1/2 3-7/8 4 5/8 1/2 3/16 V.3m 7.5
2 6 4-3/4 4 3/4 5/8 1/4 V.3m 8
3 7-1/2 6 4 3/4 5/8 1/4 V.3m 9
4 9 7-1/2 8 3/4 13/16 1/4 V.3m 10
6 11 9-1/2 8 7/8 15/16 1/4 V.3m 12
8 13-1/2 11-3/4 8 7/8 1-1/8 1/4 V.3m 16
10 16 14-1/4 12 1 1-1/4 1/4 V.3m 20
12 19 17 12 1 1-7/16 1/4 V.3m 24
dr
tr = ts
to = ts or .26" minimum
O.D. ho = hi = 1.5" ts < 3/8"
B.C. ho = hi = 2" ts < 1/2"
ho = hi = 3" ts < 3/4"
I.D.
T
6"
to
ho
ti ts
tn
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 29 of 103
Composites USA
A Critical Process Systems Group Company
V-647 30
Style No.: Sheet:
STANDARD TYPE NOZZLE SCHEDULE 150# DRILLING PER ASME RTP-1 ( ALL DIMENSIONS IN INCHES )
STD 50 PSI
PIPE I.D. FLG O.D. FLG B.C. NO. OF HOLES ti dr
HOLE DIA. T (MIN.) tn
1 4-3/4 3-1/8 4 5/8 1/2 3/16 V.3m 7
1-1/2 5-1/2 3-7/8 4 5/8 1/2 3/16 V.3m 7.5
2 6 4-3/4 4 3/4 5/8 1/4 V.3m 8
3 7-1/2 6 4 3/4 5/8 1/4 V.3m 9
4 9 7-1/2 8 3/4 13/16 1/4 V.3m 10
6 11 9-1/2 8 7/8 15/16 1/4 V.3m 12
8 13-1/2 11-3/4 8 7/8 1-1/8 1/4 V.3m 16
10 16 14-1/4 12 1 1-1/4 1/4 V.3m 20
12 19 17 12 1 1-7/16 1/4 V.3m 24
OPTIONAL TABLE
DESCRIPTION MATERIAL OF CONSTRUCTION INCLUDED NOTES
tr = ts
BOLTS/NUTS PLATED STL. YES
to = ts or .26" minimum
GASKETS NEOPRENE YES ho = hi = 1.5" ts < 3/8"
PIPE FRP YES ho = hi = 2" ts < 1/2"
ho = hi = 3" ts < 3/4"
dr
O.D.
B.C.
I.D.
ti
tn I.D.
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 30 of 103
Composites USA
A Critical Process Systems Group Company
V-650 31
Style No.: Sheet:
GUSSET AS REQUIRED
BY TANK SPECIFICATIONS
SPRAY BALL
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 31 of 103
Composites USA
A Critical Process Systems Group Company
V-655 32
Style No.: Sheet:
STANDARD TYPE NOZZLE SCHEDULE 150# DRILLING PER ASME RTP-1 ( ALL DIMENSIONS IN INCHES )
STD 50 PSI
PIPE I.D. FLG O.D. FLG B.C. NO. OF HOLES ti dr
HOLE DIA. T (MIN.) tn
1 4-3/4 3-1/8 4 5/8 1/2 3/16 V.3m 7
1-1/2 5-1/2 3-7/8 4 5/8 1/2 3/16 V.3m 7.5
2 6 4-3/4 4 3/4 5/8 1/4 V.3m 8
3 7-1/2 6 4 3/4 5/8 1/4 V.3m 9
4 9 7-1/2 8 3/4 13/16 1/4 V.3m 10
6 11 9-1/2 8 7/8 15/16 1/4 V.3m 12
8 13-1/2 11-3/4 8 7/8 1-1/8 1/4 V.3m 16
INTERNAL SUPPORT tr = ts
REQUIRED Y/N to = ts or .26" minimum
SUPPORT MATERIAL ho = hi = 1.5" ts < 3/8"
CLAMP MATERIAL ho = hi = 2" ts < 1/2"
ho = hi = 3" ts < 3/4"
A 6" 6"
OR AS SPECIFIED
ti
TANK INSIDE
GUSSET AS
REQUIRED
BY TANK
SPECIFICATIONS
LONG RADIUS D2 D1
ELBOW
to
B
SUPPORT AS BOND PIPE TO FLANGE
REQUIRED
BLIND FLANGE
VESSEL NOZZLE (NOT PART
FNPT OF REMOVABLE FILL PIPE)
tn I.D. ts ho
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 32 of 103
Composites USA
A Critical Process Systems Group Company
V-660 33
Style No.: Sheet:
B.C. O.D.
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 33 of 103
Composites USA
A Critical Process Systems Group Company
V-665 34
Style No.: Sheet:
STANDARD TYPE NOZZLE SCHEDULE 150# DRILLING PER ASME RTP-1 ( ALL DIMENSIONS IN INCHES )
VIEW VIEW VIEW STD 50 PSI
NO. OF HOLES ti dr
PIPE I.D. FLG O.D. FLG B.C. HOLE DIA. T (MIN.) tn
4 9 7-1/2 8 3/4 13/16 3/16 V.3m 10
6 11 9-1/2 8 7/8 15/16 3/16 V.3m 12
8 13-1/2 11-3/4 8 7/8 1-1/8 3/16 V.3m 16
10 16 14-1/4 12 1 1-1/4 3/16 V.3m 20
COVER NO. COVER T2
COVER I.D.2 COVER O.D. FLANGE B.C.2
OF HOLES HOLES DIA.
tn
d.r.
I.D.2
ti
T1
T1
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 34 of 103
Composites USA
A Critical Process Systems Group Company
V-670 35
Style No.: Sheet:
6" OR AS
SPECIFIED
GASKETS
REFLECTOR
ELECTRICAL
CONNECTION
ON/OFF
SWITCH
d
HALOGEN
LAMP
VIEW AREA
GLASS
INSERT
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 35 of 103
Composites USA
A Critical Process Systems Group Company
V-675 36
Style No.: Sheet:
GASKETS
6" OR AS
SPECIFIED
8-3/8"
ELECTRICAL
CONNECTION
TERMINAL
COVER
4-3/4"
5-1/8"
d
ACCESS
COVER
HALOGEN
LAMP
REFLECTOR
DIE CAST ALUMINUM
MOUNTING BRACKET
GLASS
INSERT
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 36 of 103
Composites USA
A Critical Process Systems Group Company
V-680 37
Style No.: Sheet:
3"
750
500
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 37 of 103
Composites USA
A Critical Process Systems Group Company
V-690 38
Style No.: Sheet:
N GUIDE AS REQUIRED
CLAMP WITH "U" BOLTS
B D3
CLEAR
PVC
D2
PIPE
D1
DRAIN W/ PLUG
SHUTOFF VALVE
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 38 of 103
Composites USA
A Critical Process Systems Group Company
V-700 39
Style No.: Sheet:
BAFFLE LAMINATED
TABLE TO TANK WALL
30
TANK DIA. A L S T W
SECTION A - A
OPEN TOP
AND BOTTOM
A A
L
A
S W
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 39 of 103
Composites USA
A Critical Process Systems Group Company
V-705 40
Style No.: Sheet:
BAFFLE LAMINATED
TABLE TO TANK WALL
30
TANK DIA. A L T W
SECTION A - A
CLOSED TOP
AND BOTTOM
A A
L
A
W
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 40 of 103
Composites USA
A Critical Process Systems Group Company
V-710 41
Style No.: Sheet:
TABLE
TANK DIA. A L N S T1 T2 W
30 6"
MAX
50"
T1 MAX
SECTION A - A
STANDARD 30 BRACKET L
T2
A A
60
T1
A
OPTIONAL 60 BRACKET
S W
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 41 of 103
Composites USA
A Critical Process Systems Group Company
V-715 42
Style No.: Sheet:
TABLE
TANK DIA. A L N T1 T2 W
30 6"
MAX
50"
T1 MAX
SECTION A - A
STANDARD 30 BRACKET L
T2
A A
60
T1
A
OPTIONAL 60 BRACKET
W
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 42 of 103
Composites USA
A Critical Process Systems Group Company
V-720 43
Style No.: Sheet:
STANDARD TYPE NOZZLE SCHEDULE 150# DRILLING PER ASME RTP-1 ( ALL DIMENSIONS IN INCHES )
STD 50 PSI
PIPE I.D. FLG O.D. FLG B.C. NO. OF HOLES ti dr
HOLE DIA. T (MIN.) tn
1 4-3/4 3-1/8 4 5/8 1/2 3/16 V.3m 7
1-1/2 5-1/2 3-7/8 4 5/8 1/2 3/16 V.3m 7.5
2 6 4-3/4 4 3/4 5/8 1/4 V.3m 8
3 7-1/2 6 4 3/4 5/8 1/4 V.3m 9
4 9 7-1/2 8 3/4 13/16 1/4 V.3m 10
6 11 9-1/2 8 7/8 15/16 1/4 V.3m 12
8 13-1/2 11-3/4 8 7/8 1-1/8 1/4 V.3m 16
TABLE
"D" "H" "T" NO. OF GUSSETS NOTES
PLATE O.D. HEIGHT THICKNESS
A
T
GUSSET
A
TANK BOTTOM
SECTION "A-A"
D
GUSSET
TANK BOTTOM
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 43 of 103
Composites USA
A Critical Process Systems Group Company
V-725 44
Style No.: Sheet:
A FRP OVERFLOW
BAFFLE
H H
E
A
SECTION A - A
HORIZONTAL TANK
FRP OVERFLOW
BAFFLE
B B
T
H
SECTION B - B
E
VESSEL I.D.
VERTICAL TANK
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 44 of 103
Composites USA
A Critical Process Systems Group Company
V-730 45
Style No.: Sheet:
TABLE
D TANK DIA.
A FLG. SIZE
B BEAM SPACING
C BEAM SIZE
E PLATE WIDTH
F PLATE THK.
G CENTER HOLE DIA. E
C
L BOLT CIRCLE
M HOLE DIA.
HOLD DOWN G
HOLE DIA. L
NUMBER B
SPACING
MATERIAL & COATING
PAINT
GALVANIZED
M
S.S. / C.S.
BOLT TO
STANDARD CONSTRUCTION: FLANGE
Epoxy coated A-36 steel
A
OPTIONS:
Galvanized steel
Stainless steel
FRP
AGITATOR BRIDGE
STEEL LIFTING LUG SUPPORT F
RUBBER PAD
GUSSET A
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 45 of 103
Composites USA
A Critical Process Systems Group Company
V-735 46
Style No.: Sheet:
TABLE
D TANK DIA.
B BEAM SPACING
C BEAM SIZE
E PLATE WIDTH
F PLATE THK.
G CENTER HOLE DIA.
H HEIGHT
J TOTAL WIDTH
K FOAM THK.
L BOLT CIRCLE
M HOLE DIA.
E
C
J
K G
L
B
M
FOAM
SECTION A - A
FRP BRIDGE
F B E
A A
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 46 of 103
Composites USA
A Critical Process Systems Group Company
V-740 47
Style No.: Sheet:
ANSI 150#
D FLANGE
CONE
6 OR AS GUSSET
SPECIFIED
TOP HEAD
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 47 of 103
Composites USA
A Critical Process Systems Group Company
V-745 48
Style No.: Sheet:
SHELL
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 48 of 103
Composites USA
A Critical Process Systems Group Company
V-750 49
Style No.: Sheet:
TABLE
STANDARD T H W L NOTES
BRACKET NO.
AB-0
AB-1
AB-2
AB-3
LOCAL SHELL T W
REINFORCEMENT
FRP PLATE
H
L L
OVERLAY
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 49 of 103
Composites USA
A Critical Process Systems Group Company
V-755 50
Style No.: Sheet:
FRP
L M
NEOPRENE
E
RETAINING
RING
COLLAR
G = D - 12"
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 50 of 103
Composites USA
A Critical Process Systems Group Company
V-760 51
Style No.: Sheet:
EXPANSION JOINTS
AS REQUIRED BY
ENGINEERING DESIGN
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 51 of 103
Composites USA
A Critical Process Systems Group Company
V-765 52
Style No.: Sheet:
HEATING
ELEMENT
INSULATION
TANK SHELL
CONTROL BOX
CONTROL
BOX HEATING
ELEMENT
HEATING
ELEMENT
120 VAC
POWER LEAD
WIRES W/ GROUND
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 52 of 103
Composites USA
A Critical Process Systems Group Company
V-770 53
Style No.: Sheet:
HEATING
COILS
VARIES
FRP SUPPORT
OFF TANK BOTTOM
OR SIDE
SECTION A-A
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 53 of 103
Composites USA
A Critical Process Systems Group Company
V-775 54
Style No.: Sheet:
INSIDE TANK
FRP SUPPORT
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 54 of 103
Composites USA
A Critical Process Systems Group Company
V-780 55
Style No.: Sheet:
FRP OUTSIDE
TANK WALL
INTERSTITIAL MESH
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 55 of 103
Composites USA
A Critical Process Systems Group Company
V-785 56
Style No.: Sheet:
Optional Features:
- Multi channel monitor
- Acid sensor cable
- Hydrocarbon corrosive cable
- Junction box NEMA 4x
JUNCTION
BOX
INNER SHELL
AND BOTTOM
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 56 of 103
Composites USA
A Critical Process Systems Group Company
V-800 57
Style No.: Sheet:
THK
1/2"
SHIM AS REQ'D
BY OTHERS
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 57 of 103
Composites USA
A Critical Process Systems Group Company
V-805 58
Style No.: Sheet:
FRP BUILDUP
INSIDE TANK
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 58 of 103
Composites USA
A Critical Process Systems Group Company
V-810 59
Style No.: Sheet:
FRP OVERLAY
STEEL ANGLE
SEE VESSEL
X
DRAWING
FOR SIZES
e
W
L
FRP REINFORCEMENT
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 59 of 103
Composites USA
A Critical Process Systems Group Company
V-815 60
Style No.: Sheet:
F2
RATING
1/4" ( Based on 5:1 factor of safety )
1/2" THK. FW
OVERLAY (TYP)
5/8" R
10" 6"
3"
1"
1"
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 60 of 103
Composites USA
A Critical Process Systems Group Company
V-820 61
Style No.: Sheet:
F3
F1 = 1500 LB MAX
F2 = 400 LB MAX
F1 F3 = 3000 LB MAX
F2
RATING
( Based on 5:1 factor of safety )
12"
4"
INSIDE
VESSEL
1/4" THK
4" WELD
12"
2" RADIUS
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 61 of 103
Composites USA
A Critical Process Systems Group Company
V-825 62
Style No.: Sheet:
1/2" THK.
1" DIA. HOLE 2" RAD.
CAR. STL.
LIFTING LUG
FRP OVERLAY
3"
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 62 of 103
Composites USA
A Critical Process Systems Group Company
V-830 63
Style No.: Sheet:
MATERIAL A B C TC TO NOTES
FRP 4 4 2 0.250" 4M STANDARD CONSTRUCTION
TC
FRP OVERLAY C
TO
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 63 of 103
Composites USA
A Critical Process Systems Group Company
V-835 64
Style No.: Sheet:
MATERIAL A B C TC TO D X Y NOTES
FRP 4 4 4 0.375" 6M - - - STANDARD CONSTRUCTION
TC
TO
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 64 of 103
Composites USA
A Critical Process Systems Group Company
V-840 65
Style No.: Sheet:
W H T L LB/LUG MATERIAL
NOTE 1
G0 4 4 .250 - 280 FRP
G1 4 6 .375 4.5 663 CARBON STL.
G2 6 8 .500 4.5 1767 CARBON STL.
G3 6 10 .750 4.5 3977 CARBON STL.
G4 8 10 .875 4.52 7656 CARBON STL.
12"
4"
INSIDE
STACK
1/4" THK
4" H WELD
(MRMMRM)
12"
2" RADIUS
H R=1"(REF)
2"
L W
45
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 65 of 103
Composites USA
A Critical Process Systems Group Company
V-845 66
Style No.: Sheet:
1"
FRP STACK WALL
REINFORCEMENT = TR
FRP STACK WALL = TS FRP GUY RING
GUY RING
OVERLAY
FRP STACK WALL 5/8" DIA. HOLES
REINFORCEMENT = TR
GUY RING
FRP GUY RING
OVERLAY
1" DIA.
HOLE
H
BOLT HOLE
2"
4"
H
GUY LUG DETAIL
GUY WIRE
HOLE
BOLT HOLE
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 66 of 103
Composites USA
A Critical Process Systems Group Company
V-850 67
Style No.: Sheet:
T
L
INSIDE TANK
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 67 of 103
Composites USA
A Critical Process Systems Group Company
V-855 68
Style No.: Sheet:
T
VARIES
INSIDE TANK
L
0
W
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 68 of 103
Composites USA
A Critical Process Systems Group Company
V-860 69
Style No.: Sheet:
Fitting: Ladders
A ASME RTP-1 Certified Fiberglass Tanks & Process Vessels Standards
S
M Underwriters C UL
US Notes: 1. Dimensions may vary. Shown are typical dimensions for carbon steel ladder.
E
Laboratories 2. Ladder overall height = H1 + walk through (if any).
RTP Listed LISTED
Options: 1. Materials of construction: FRP, carbon steel, galvanized steel, stainless
steel, aluminum.
2. Walk through or straight.
3. Side rail construction: flat bar, angle or square tubing.
STEP OFF
16-3/4"
1
38" 1
42"
1-1/2" SQ.
15" TUBING
DET. A
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 69 of 103
Composites USA
A Critical Process Systems Group Company
V-865 70
Style No.: Sheet:
2 14-3/8"
1 R = 13-1/2"
R = 13-1/2"
16-3/8" 1-7/8"
1
40
TYP
TYP 3-7/8"
43"
H2
FB 2" x 5/16"
TYP 3
H1
33"
ITEM 3
CAGE
ASSEMBLY
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 70 of 103
Composites USA
A Critical Process Systems Group Company
V-870 71
Style No.: Sheet:
GRATING FRP
STRUCTURE
SUPPORT
C
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 71 of 103
Composites USA
A Critical Process Systems Group Company
V-875 72
Style No.: Sheet:
ANGLE
KNEE BRACE
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 72 of 103
Composites USA
A Critical Process Systems Group Company
V-880 73
Style No.: Sheet:
1-1/2" SCH 80
ARC = NOT TO EXCEED 8'-0" ( 1.90" O.D. )
PIPE CAR. STL.
21"
42"
TYP TYP
DETAIL "A"
TOE PLATE
TYPICAL HANDRAIL DETAIL 1/4" THK x 4" HIGH
BASE PLATE
2"
4x8x1/4
TYP
4"
DETAIL "A"
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 73 of 103
Composites USA
A Critical Process Systems Group Company
V-885 74
Style No.: Sheet:
42"
FRP STRUCTURAL
SUPPORT, NUMBER AND
SIZES AS REQUIRED
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 74 of 103
Composites USA
A Critical Process Systems Group Company
V-900 75
Style No.: Sheet:
VESSEL I.D. RING WIDTH RING THK. DESIGN LOAD INTERMEDIATE DRILLING
LB/FT 2 SUPPORT IF ANY NOTES
"D" "W" "T" REQUIRED
VESSEL I.D.
OPTIONAL
CONTINUOUS FRP RING,
INTERMEDIATE
SIZE DETERMINED BY
SUPPORT
VESSEL DESIGN
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 103 of 103
Composites USA
A Critical Process Systems Group Company
V-905 76
Style No.: Sheet:
VESSEL I.D.
45
TYP
T
WIPER I.D.
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 76 of 103
Composites USA
A Critical Process Systems Group Company
V-910 77
Style No.: Sheet:
VESSEL I.D.
FRP GRATING
OPTIONAL
INTERMEDIATE
SUPPORT
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 77 of 103
Composites USA
A Critical Process Systems Group Company
V-915 78
Style No.: Sheet:
PLATE MATERIAL OF
SUPPORT BEAM NOTES
THICKNESS CONSTRUCTION
W H FRP, PP, PVDF STANDARD CONFIGURATION
T NUMBER
WIDTH HEIGHT THICKNESS BASED ON LOADS
PER VESSEL
7.5" 11"
DIAMETER
SECTION A - A
W
A
T
H
VESSEL I.D. A
DETAIL
MULTIBEAM
PACKING SUPPORT
( SEE DETAIL )
FRP CONTINUOUS
SUPPORT RING
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 78 of 103
Composites USA
A Critical Process Systems Group Company
V-920 79
Style No.: Sheet:
LT
LW
WT
VESSEL I.D.
WEIR-TROUGH
WW
SIZE RANGE 48" DIA.
TW WEIR BOX AND LARGER
HW
WT
HT
TROUGH
OUTLET
FRP CONTINUOUS
SUPPORT RING SUPPORT BEAM(S)
AS REQUIRED
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 79 of 103
Composites USA
A Critical Process Systems Group Company
V-925 80
Style No.: Sheet:
RISERS
DOWNCOMER
HOLES
VESSEL I.D.
RISERS
FRP CONTINUOUS
SUPPORT RING
DOWNCOMER
HOLES
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 80 of 103
Composites USA
A Critical Process Systems Group Company
VB-1000 81
Style No.: Sheet:
tb
ti
JOINT
LINE
OUTSIDE
RADIUS = 1" MIN. FOR TANK DIA. OVERLAY
48" AND UNDER, 1-1/2" MIN. FOR
TAND DIA. 48" AND OVER
to
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 81 of 103
Composites USA
A Critical Process Systems Group Company
VB-1005 82
Style No.: Sheet:
TANK INTERNAL BOTTOM INSIDE BOTTOM OUTSIDE SLOPE LOW SIDE CORE CROSS BRACING
DIAMETER LAMINATE THK. LAMINATE THK. IN/FT HEIGHT REQUIRED
"D" Ti To "X" HL DENSITY Y/N
.25"/FT 1" LB/FT 3
2.2 FRP STANDARD
12"
X
ti
FRP COVER
SEE VESSEL
DRAWING FOR
BOTTOM SLOPE
OUTSIDE
OVERLAY
JOINT
LINE
FOAM HL
tO
to
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 82 of 103
Composites USA
A Critical Process Systems Group Company
VB-1010 83
Style No.: Sheet:
ti
JOINT
LINE
OUTSIDE
RADIUS = 1" MIN. FOR TANK DIA. OVERLAY
48" AND UNDER, 1-1/2" MIN. FOR
TAND DIA. 48" AND OVER
to
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 83 of 103
Composites USA
A Critical Process Systems Group Company
VB-1030 84
Style No.: Sheet:
RK RD
J.L.
S.F. T.L.
O.A.H.
H
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 84 of 103
Composites USA
A Critical Process Systems Group Company
VB-1040 85
Style No.: Sheet:
MAY BE
TORISPHERICAL
T
45
1/2 x DIA.
6" OR AS SPECIFIED
I.D.
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 85 of 103
Composites USA
A Critical Process Systems Group Company
VB-1045 86
Style No.: Sheet:
8'-0" I.D.
67-1/2
21-3/8"
6" OR AS SPECIFIED
I.D.
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 86 of 103
Composites USA
A Critical Process Systems Group Company
VB-1050 87
Style No.: Sheet:
d
D
D END
CAP
A A
F
d
PIPE LEG
SECTION A - A
JOINT LINE
T.L.
GUSSET AS H
REQUIRED
PIPE
LEG
C tb
d BASE PLATE
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 87 of 103
Composites USA
A Critical Process Systems Group Company
VB-1055 88
Style No.: Sheet:
END W
CAP
D
F
ANGLE
A L
A
SECTION A - A
T.L.
ANGLE H
L x L x tL
C tb
A BASE PLATE
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 88 of 103
Composites USA
A Critical Process Systems Group Company
VB-1060 89
Style No.: Sheet:
FRP VESSEL
FRP LAY UP
T.L.
6" OR AS
SPECIFIED
REINFORCEMENT SKIRT
SKIRT ACCESS
D T
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 89 of 103
Composites USA
A Critical Process Systems Group Company
VB-1065 90
Style No.: Sheet:
FRP VESSEL
FRP FRAME
AND CRADLE
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 90 of 103
Composites USA
A Critical Process Systems Group Company
VB-1070 91
Style No.: Sheet:
A A
DH
DS
DH H
C
A
SECTION A - A
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 91 of 103
Composites USA
A Critical Process Systems Group Company
VB-1075 92
Style No.: Sheet:
LAMINATED
SUPPORT BAND
TANK WALL
RUBBER SHEAR PLY
SUPPORT
DETAIL A
Z AS REQUIRED
LAMINATED
SUPPORT R
D
BAND
120
A
DET. A
B X Y
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 92 of 103
Composites USA
A Critical Process Systems Group Company
VT-1100 93
Style No.: Sheet:
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 93 of 103
Composites USA
A Critical Process Systems Group Company
VT-1105 94
Style No.: Sheet:
DO NOT
WELD
HANDLE
CONTINUOUS PIANO HINGE
T
A B
D THK.
SEE VESSEL DWG.
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 94 of 103
Composites USA
A Critical Process Systems Group Company
VT-1110 95
Style No.: Sheet:
"DT " "T" NO. OF HOLE HOLE GASKET BOLT NO. OF NOTES
HOLES DIA. B.C. MATERIAL MATERIAL HANDLES
NOT NOT NOT STANDARD
INCLUDED INCLUDED INCLUDED CONSTRUCTION
FOR NUMBER
OF BOLTS/SIZE
SEE VESSEL
DRAWING
DT
T
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 95 of 103
Composites USA
A Critical Process Systems Group Company
VT-1115 96
Style No.: Sheet:
"DT " A B "T" NO. OF HOLE HOLE HINGE GASKET BOLT NO. OF NOTES
HOLES DIA. B.C. MATERIAL MATERIAL MATERIAL HANDLES
DO NOT
WELD
HANDLE
CONTINUOUS PIANO HINGE
T
A B
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 96 of 103
Composites USA
A Critical Process Systems Group Company
VT-1120 97
Style No.: Sheet:
1/8" (MIN.)
DT
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 97 of 103
Composites USA
A Critical Process Systems Group Company
VT-1125 98
Style No.: Sheet:
NOMINAL
VESSEL I.D. COVER I.D. "A" "B" "T" HINGED MATL. OF NO. OF NOTES
"D" "D T " CONSTRUCTION HANDLES
HANDLE
2"
1/8" (MIN.)
A B
DT
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 98 of 103
Composites USA
A Critical Process Systems Group Company
VT-1130 99
Style No.: Sheet:
H
O.A.H.
T.L.
J.L. S.F.
RK
RD
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 99 of 103
Composites USA
A Critical Process Systems Group Company
VT-1135 100
Style No.: Sheet:
H O.A.H.
T.L.
RK
RD S.F.
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 100 of 103
Composites USA
A Critical Process Systems Group Company
VT-1140 101
Style No.: Sheet:
6" OR AS SPECIFIED
I.D.
1/2 x DIA.
45
T
MAY BE
TORISPHERICAL
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 101 of 103
Composites USA
A Critical Process Systems Group Company
VT-1145 102
Style No.: Sheet:
I.D.
6" OR AS SPECIFIED
21-3/8"
67-1/2
8'-0" I.D.
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 102 of 103
Composites USA
A Critical Process Systems Group Company
VT-1150 103
Style No.: Sheet:
STANDARD VESSELS
( ALL DIMENSIONS IN INCHES )
TANK I.D. T NOTES
24
48
96
Composites USA This document contains confidential and proprietary information intended solely for the use of
One Peninsula Drive / North East, MD 21901 individuals or entities for reference only. The information contained herein shall not be disclosed,
T 410.287.2270 / F 410.287.5222 copied, or distributed other than for the intended purpose without express written consent of
Email: info@compositesusa.com Composites USA.
Fiberglass Tanks & Process Vessels Standards - Rev: A02.2015 - Page 103 of 103