EXCESSIVE NOISE

A B C

PUMP NOISY MOTOR NOISY RELIEF VALVE NOISY

1. Cavitation 1. Coupling misaligned 1. Setting too low or too


Remedy: a Remedy: c close to another valve
setting
Remedy: d

2. Air in fluid 2. Motor or coupling 2. Worn poppet and seat


Remedy: b worn or damaged Remedy: e
Remedy: b
3. Coupling Misaligned
Remedy: c

4. Pump worn or
damaged
Remedy: e

Remedies:
a. Any or all of the following: b. Any or all of the following: c. Align unit and check condition of
seals, bearings and coupling.
Replace dirty filters; wash strainers Tighten leaking connections;
in solvent compatible with system d. Install pressure gauge and adjust
fluid; clean clogged inlet line; clean fill to correct pressure.
or replace reservoir breather vent; reservoir to proper level (with rare
change system fluid; change to exception all return lines should be e. Overhaul or replace.
proper pump drive motor speed; below fluid level in reservoir); bleed
overhaul or replace supercharge air from system; replace pump
pump; fluid may be too cold. shaft
seal (and shaft if worn at seal
journal).
EXCESSIVE
HEAT

A B C D

PUMP HEATED MOTOR HEATED RELIEF VALVE HEATED FLUID


HEATED

1. 1. Fluid heated 1. Fluid heated 1. System pressure too


Remedy: See column D Remedy: See column D Remedy: See column D high
Remedy: d

2. Cavitation 2. Relief or unloading 2. Valve setting incorrect 2. Unloading valve set


Remedy: a valve set too high Remedy: d too high
Remedy: d Remedy: d

3. Air in fluid 3. Excessive load 3. Worn or damaged valve 3. Fluid dirty or low supply
Remedy: b Remedy: c Remedy: e Remedy: f

4. Relief or unloading 4. Worn or damaged 4. Incorrect fluid


valve set too high motor viscosity
Remedy: d Remedy: e Remedy: f

5. Excessive load 5. Faulty fluid cooling


Remedy: c system
Remedy: g

6. Worn or damaged 6. Worn pump, valve,


pump motor, cylinder or other
component
Remedy: e
Remedy: e
Remedies:
a. Any or all of the following: c. Align unit and check condition of g. Clean cooler and/or cooler strainer;
Replace dirty filters; clean clogged seals and bearings; locate and replace cooler control valve; repair
inlet line; clean or replace reservoir correct mechanical binding; check for or replace cooler.
breather vent; change system work load in excess of circuit design.
fluid; change to proper pump drive
motor speed; overhaul or replace d. Install pressure gauge and adjust
supercharge pump. to correct pressure (keep at least
125
b. Any or all of the following: PSI difference between valve
settings).
Tighten leaking connections;
fill e. Overhaul or replace.
reservoir to proper level (with rare
exception all return lines should be f. Change filters and also system fluid
below fluid level in reservoir); bleed if improper viscosity; fill reservoir to
air from system; replace pump proper level.
shaft seal (and shaft if worn at seal
journal).

Das könnte Ihnen auch gefallen