PREVENTIVE MAINTENANCE USAGE RATE CALCU

(Based on Least Square Regression Form


The Formula for Usage Rate Calculation is
Usage Rate = ((XY) - ( (X * Y) /N) ) / ( X 2 - ( (X)2 / N) )

X = current_reading_date - sysdate No of Past Readings defined for the Me


Y = life to date reading
N = No of Past Readings + 1

Current Reading Date System Date Life To Date Reading X

1/8/2006 7:21 6/23/2006 8:29 100 -166.0472453704


1/7/2006 7:21 6/23/2006 8:29 70 -167.0472453704
1/6/2006 7:21 6/23/2006 8:29 50 -168.0472453704
1/5/2006 7:21 6/23/2006 8:29 35 -169.0472453704
1/4/2006 7:21 6/23/2006 8:29 20 -170.0472453704
1/3/2006 7:21 6/23/2006 8:29 10 -171.0472453704

-1011.2834722222
(X)2 1022694.26118983

((XY) - ( (X * Y) /N) ) 307.5

( X2 - ( (X)2 / N) ) 17.5

Usage Rate 17.5714285714


AGE RATE CALCULATOR
Regression Formula)

ast Readings defined for the Meter = 5

Y XY X2

100 -16604.7245370370 27571.687695


70 -11693.3071759259 27904.782186
50 -8402.3622685185 28239.876677
35 -5916.6535879629 28576.971167
20 -3400.9449074074 28916.065658
10 -1710.4724537037 29257.160149

285 -47728.4649305553 170466.54353


PREVENTIVE MAINTENANCE USAGE RATE CALCULA
(Based on Direct Averaging)
The Formula for Usage Rate Calculation is

Usage Rate = (x_first_reading - x_last_reading) / (x_first_reading_date - x_last_reading_date)

No of Past Readings defined for the Meter = 5

LIFE_TO_DATE_READING
100
70
50
35
20

(x_first_reading - x_last_reading) 80

(x_first_reading_date - x_last_reading_date) 4.00000

Usage Rate 20
USAGE RATE CALCULATOR