sali
Air Starter
Al7
Oel and service free
The type A17 air starters are
generally used for starting Diesel
engines of an approximate rating of up
to 300 kW (400 HP), although the suitability
depends, in practice, on the engine capacity, number
of cylinders and the ration of the driving pinion to
the flywheel ring gear.
Optimum starting conditions exist in the case of
engines of approx. 12 dm* (732 in’) total capacity
where the starting pressure is of 1-3 MPa (145—
435 ibffin), allowing thus for a considerable starting
reserve. If the available reserve capacity of starting
air is high or ifthe installation permits a reduction in
the number of starts, the pressure range can be con-
firmed to 2-3 MPa (290-435 ibifin’), thus allowing
the use of the type A17 starters for engines of up to
twice the capacity mentioned above.
‘ir power ot
ss677
52751200)
Clearance betveen cin non and Rywheal ger og
If the conditions of installation require the starter to
operate at its upper limit of power output, itis strongly
advisable that the more powerful type be selected.
The inlet nozzle may be arranged in four different
positions with regard to the exhaust.
‘The type A17 air starters are available for clockwise
and counterclockwise rotation. They are successfully
‘used in:
— Emergency generating sets
= Motor-compressor sets
= Motor-pump sets
~ Auxiliary ship engines or main engines of
smaller vessels
Industrial engines
— Forklift truck engines or those of other
industrial vehicles,
Max 12 (47 dep
rsus9
Alleaereonts mi
BAD boss 000 D-55411BINGEN - Am Ockenhelmer Graben 32 - Tel: (06721) 10026 + 10027 - Fax: (06721) 131.44Airstarter A17
POWER AND TORQUE FREE AIR DELIVERY
bb. tt Nm TORQUE POWER kW FAD, dnife av
$54 0 0 a
aye 10
504 70 he e
60 12 8
”
50 10 a
‘
204 49 5
5
7 ‘
| ®
3
0 ‘
10: -
10 2
1
0
0 1000 —2000-«—