Beruflich Dokumente
Kultur Dokumente
eXM UPS
10-250 kVA/kW
Efficient, Scalable, Intelligent Power
Optimized for Midsize IT
LIEBERT EXM UPS
yySuperior operating efficiencies are realized through both the Eco-Mode option, which yy Next Generation Touchscreen
performs at 99% and the Double Conversion Mode, which delivers 97% (480V Control Panel
models) The Liebert eXM UPS is ideal for:
yyENERGY STAR qualified yy Small to midsize IT applications
Liebert eXM UPS (40kVA/kW, 208V) in Double Conversion Mode yy Edge of the network operations
99%
98% yy Midsize/regional
97% colocation facilities
96% Liebert eXM UPS
Double Conversion
Efficiency
Touch-Screen Control Panel Offers yyVerify the health of the entire battery
Intelligent Control system
2
Flexible Configurations and Deployment Options
CRITICAL SERVICES
AND SUPPORT
Scale With Ease LIFE Services for
The flexible, scalable, redundant design of the Liebert eXM UPS is available in many yy24x7 continuous remote monitoring
system configurations to ensure optimal power protection. yyExpert analysis and diagnosis
Liebert Services
yy24x7 critical maintenance response
Response
3
LIEBERT EXM UPS
Specifications
208V NATIVE 208V NATIVE 480V NATIVE
Power Rating kW/kVA 10, 15, 20, 30, 40 60, 80, 100, 120, 140, 160, 180, 200 50, 100, 150, 200, 250
Internal Battery Supported Y N N
Input AC Specifications Phase/Power Factor/
3 / 0.99 lagging minimum at full load / 40-70 Hz
Freq Range
Input Voltage 208, 220, 4801, 6001 VAC, 60Hz, 3-phase, 4-wire plus ground 480, 600 VAC, 60Hz, 3-phase, 3-wire plus ground
General Specifications UPS Technology On-Line Double Conversion
Battery Specifications Battery Test Type/
Online / Valve-regulated lead acid battery
Battery Technology
Output AC Specifications Voltage 208/120, 220/127VAC, 60Hz 3-phase, 3- or 4-wire plus ground 480VAC, 60Hz 3-phase, 3-wire plus ground
Frequency Hz 60 Hza
Communications Options 3 Liebert IntelliSlots
Card Compatibility IS-UNITY-DP, IS-UNITY-LIFE, IS-485EXI, IS-RELAY
Protocols Available MODBUS-IP, MODBUS-485, BACNET-IP, BACNET-MSTP, SNMP, HTTP, LIFETM Services, Relay Contacts
Environmental Sensors Liebert SN Series Temperature, Humidity, Temperature/Humidity Combination, Contact Closure
Unit Weight
Physical Data UPS UPS Rating Dimensions, W X D X H in (mm) Unit Weight lb (kg) Dimensions, W X D X H in (mm)
lb (kg)
10kVA, 15kVA, 20kVA 604 (274) 23.6 x 39.5 x 78.7 (600 x 1000 x 2000)
30kVA, 40kVA 678 (307.5) 23.6 x 39.5 x 78.7 (600 x 1000 x 2000)
23.6 x 39.5 x 78.7
50kVA N/A N/A 748 (339)
(600 x 1000 x 2000)
60kVA 807 (366) 23.6 x 39.5 x 78.7 (600 x 1000 x 2000)
80kVA 881 (399.6) 23.6 x 39.5 x 78.7 (600 x 1000 x 2000)
23.6 x 39.5 x 78.7
100kVA 955 (433.1) 23.6 x 39.5 x 78.7 (600 x 1000 x 2000) 842 (382)
(600 x 1000 x 2000)
120kVA 1221 (553.8) 34.6 x 39.5 x 78.7 (880 x 1000 x 2000)
140kVA 1295 (587.4) 34.6 x 39.5 x 78.7 (880 x 1000 x 2000)
23.6 x 39.5 x 78.7
150kVA 936 (425)
(600 x 1000 x 2000)
160kVA 1368 (620.5) 34.6 x 39.5 x 78.7 (880 x 1000 x 2000)
180kVA 1442 (654) 34.6 x 39.5 x 78.7 (880 x 1000 x 2000)
23.6 x 39.5 x 78.7
200kVA 1516 (687.6) 34.6 x 39.5 x 78.7 (880 x 1000 x 2000) 1030 (467)
(600 x 1000 x 2000)
33.0 x 39.5 x 78.7
250kVA N/A N/A 1244 (564)
(880 x 1000 x 2000)
Physical Data Ancillaries Weight lb (kg) Dimensions, W X D X H in (mm) Weight lb (kg) Dimensions, W X D X H in (mm)
600mm Bypass Distribution Cabinet 550 (250) 23.6 x 39.5 x 78.7 (600 x 1000 x 2000) N/A N/A
11.8 x 39.5 x 78.7
300mm Maintenance Bypass Cabinet 288 (131) 11.8 x 39.5 x 78.7 (300 x 1000 x 2000) 288 (131)
(300 x 1000 x 2000)
7.9 x 39.5 x 78.7
200mm Maintenance Bypass Cabinet 198 (90) 7.9 x 39.5 x 78.7 (200 x 1000 x 2000) 198 (90)
(200 x 1000 x 2000)
4907 (2226) with 47.2 x 39.5 x 78.7
1200mm Battery Cabinet2 N/A N/A
HX540 batteries (1200 x 1000 x 2000)
3649 (1656) with 2962 (1344) with 34.7 x 39.5 x 78.7
880mm Battery Cabinet2 34.7 x 39.5 x 78.7 (880 x 1000 x 2000)
HX540 batteries HX300 batteries (880 x 1000 x 2000)
2454 (1114) with
600mm Battery Cabinet2 23.6 x 39.5 x 78.7 (600 x 1000 x 2000) N/A N/A
HX330 batteries
1432 (650) with
320mm Battery Cabinet3 12.6 x 39.5 x 78.7 (320 x 1000 x 2000) N/A N/A
HX205 batteries
Operating Temperature, F (C): UPS: 32 to 104F (0-40C); Battery: 68 to 86F (20-30C). Relative Humidity: 0% to 95%,
Environmental non-condensing. Operating Altitude: Up to 3,300 ft. (1,000m) without derating. Acoustical Noise, db, at 39 in.: Less than 59 dBA typical,
3.3 ft. (1m) from the unit
Listed to UL 1778 and CSA certified. Meets current requirements for safe high performance UPS operation.
Agency/Certification/Conformance
ENERGY STAR qualified
Warranty Standard 1 year
4
VertivCo.com | Vertiv Headquarters, 1050 Dearborn Drive, Columbus, OH, 43085, USA
2016 Vertiv Co. All rights reserved. Vertiv and the Vertiv logo are trademarks or registered trademarks of Vertiv Co. All other names and logos referred to are trade names, trademarks or registered trademarks of their respective owners. While every precaution has been
taken to ensure accuracy and completeness herein, Vertiv Co. assumes no responsibility, and disclaims all liability, for damages resulting from use of this information or for any errors or omissions. Specifications are subject to change without notice.
SL-26003 (06/16)