Beruflich Dokumente
Kultur Dokumente
This document has been archived and will no longer be maintained or updated.
For a full list of papers go to
http://en.community.dell.com/techcenter/storage/w/wiki/2632.storage-infrastructure-and-solutions-team-publications.aspx
or contact support.
2011 Dell Inc. All rights reserved. Reproduction of this material in any manner whatsoever without
the express written permission of Dell Inc. is strictly forbidden. For more information, contact Dell.
Dell, the DELL logo, and the DELL badge, PowerConnect, EqualLogic, PowerEdge and
PowerVault are trademarks of Dell Inc. Broadcom is a registered trademark of Broadcom
Corporation. Cisco and Cisco Nexus are registered trademarks of Cisco Systems, Inc. and/or its
affiliates in the U.S. and other countries. Intel is a registered trademark of Intel Corporation in the
U.S. and other countries. Microsoft, Windows, Windows Server, and Active Directory are either
trademarks or registered trademarks of Microsoft Corporation in the United States and/or other
countries.
SWRA1013 Dell EqualLogic PS Series Reference Architecture for Cisco Nexus 5020 i
Table of Contents
1 Introduction ....................................................................................................................................................... 2
2 Objective ............................................................................................................................................................. 3
3 Conclusions........................................................................................................................................................ 4
4 Reference architecture..................................................................................................................................... 5
4.1 Reference architecture overview ........................................................................................................... 5
4.2 Server configuration ..................................................................................................................................7
4.3 Array configuration ....................................................................................................................................7
4.4 Switch configuration..................................................................................................................................7
4.4.1 Overview of the switch configuration ............................................................................................7
4.4.2 Global Switch Setting: Configure no-drop class and jumbo frames ....................................... 8
4.4.3 Array and server port configuration ............................................................................................... 9
4.4.4 Link Aggregation Group configuration........................................................................................ 10
Appendix A Switch port mapping ...................................................................................................................13
Appendix B TCP/IP configuration .................................................................................................................. 14
SWRA1013 Dell EqualLogic PS Series Reference Architecture for Cisco Nexus 5020 ii
Acknowledgements
This whitepaper was produced by the PG Storage Infrastructure and Solutions team between October
2011 and December 2011 at the Dell Labs facility in Round Rock, Texas.
Feedback
We encourage readers of this publication to provide feedback on the quality and usefulness of this
information. You can submit feedback to this email address:
SISfeedback@Dell.com
SWRA1013 Dell EqualLogic PS Series Reference Architecture for Cisco Nexus 5020 1
1 Introduction
The Cisco Nexus 5020 is a two-rack-unit (2RU), 10 Gigabit Ethernet, Fibre Channel over Ethernet
(FCoE), and Fibre Channel switch built to provide 1.04 terabits per second (Tbps) throughput with very
low latency. It has 40 fixed 10 Gigabit Ethernet and FCoE Small Form-Factor Pluggable Plus (SFP+)
ports. The hardware of the first 16 fixed ports supports both 10 Gigabit Ethernet and Gigabit Ethernet,
providing a smooth migration path to 10 Gigabit Ethernet. Two expansion module slots can be
configured to support up to 12 additional 10 Gigabit Ethernet and FCoE SFP+ ports, up to 16 Fibre
Channel switch ports, or a combination of both. The switch has a serial console port and an out-of-
band 10/100/1000-Mbps Ethernet management port. The switch is powered by 1+1 redundant, hot-
pluggable power supplies and 4+1 redundant, hot-pluggable fan modules to provide highly reliable
front-to-back cooling.
SWRA1013 Dell EqualLogic PS Series Reference Architecture for Cisco Nexus 5020 2
2 Objective
This document provides details on configuring the Cisco Nexus 5020 switch for use with Dell
EqualLogic PS Series storage arrays. The goal of this exercise is not to provide a comprehensive set
of possible configurations, but to illustrate one possible solution that provides excellent performance
and scalability as validated by testing in our labs.
Note: The Cisco Nexus 5020 switch is targeted at converged DCB environments, but the switch does
not fully support the IEEE DCB standards for iSCSI over DCB. Because of this, this reference
architecture is focused on using the Cisco Nexus 5020 switch as a non-DCB Ethernet network
infrastructure.
The test objectives used while testing the Cisco Nexus 5020 switch configuration are defined below:
Test the ability of the switch configuration to pass iSCSI traffic as defined by realistic
application workloads and server/storage configurations while meeting stringent networking
performance parameters.
Determine the scalability behavior of the switch configuration for a standardized set of I/O
workloads and provide sizing guidance in terms of the number of storage arrays and servers
that can be supported by a SAN consisting of Cisco Nexus 5020 switches.
SWRA1013 Dell EqualLogic PS Series Reference Architecture for Cisco Nexus 5020 3
3 Conclusions
Cisco Nexus 5020 switch passed switch validation objectives in a dual switch configuration with up to
12 arrays.
With the Cisco Nexus 5020 switches, the SAN scaled easily to support 12 arrays and 12 hosts.
Sequential Write performance scaled linearly to 97% of the theoretical baseline in terms of
throughput as measured at the host.
Sequential Read Performance scaled linearly to 91% in terms of throughput as measured at the
host.
The Random Read/Write performance in terms of IOs per second scaled to 88% of the
theoretical baseline on a per-server performance basis.
TCP retransmissions from arrays, as polled periodically from array counters and SAN
Headquarters (SANHQ) were low (< 0.1%) across all test configurations. This is another
indicator that there are no bottlenecks or design issues within the switch that limited the ability
of the switch to support the reference architecture.
Recommended number of arrays is up to 12+ arrays in a dual switch configuration due to port
count limits.
In conclusion, our test results indicate that the only limitation this reference architecture has with
respect to scaling an EqualLogic SAN is in the number of available ports that two switches provide, not
with any limitations in the performance of the switch.
SWRA1013 Dell EqualLogic PS Series Reference Architecture for Cisco Nexus 5020 4
4 Reference architecture
Because our goal is to help you deploy a switch-based SAN easily and quickly, we use a standard host
configuration and a standard EqualLogic Group configuration, accept default switch settings wherever
possible, and employ all accepted best-practice recommendations for EqualLogic SANs.
The Cisco Nexus 5020 switch is targeted at converged DCB environments, but the switch
does not fully support the IEEE DCB standards for iSCSI over DCB. Because of this, this
reference architecture is focused on using the Cisco Nexus 5020 switch as a non-DCB
Ethernet network infrastructure.
All hosts have two iSCSI Ethernet ports attached to the SAN.
All NICs are configured based on the default, out of the box settings where possible.
o The exceptions are the use of Jumbo Frames and Flow Control, both of which are
enabled for all testing.
Microsoft Windows Server is the operating system used for all hosts.
We use EqualLogic Host Integration Toolkit for all hosts. In particular, we use the MPIO Device
Specific Module to provide EqualLogic-aware multi-pathing.
Host connections to the SAN are equal to the number of active array ports connected to the
SAN.
o Since each PS6x10 series array has two active array ports, for each array in the test
configuration there is one host connected to the SAN.
All SAN infrastructures are single subnet, non-routed designs.
All SAN infrastructures are based on standard IPv4 addressing.
All testing includes three pre-defined standardized workloads that reflect various types of real-
world SAN utilization.
Note: For more information on EqualLogic SAN design common practice recommendations, consult
the EqualLogic Configuration Guide that can be found
at www.delltechcenter.com/page/equallogic+configuration+guide
SWRA1013 Dell EqualLogic PS Series Reference Architecture for Cisco Nexus 5020 5
Figure 1 Two switch and 12 array SAN test configuration
SWRA1013 Dell EqualLogic PS Series Reference Architecture for Cisco Nexus 5020 6
4.2 Server configuration
This reference architecture uses 12 PowerEdge R610 rack servers. Each server is described in Table 1
below.
Based on our analysis of the switch architecture and lab testing, the following subsections specify the
commands and settings recommended to configure the switches in this reference architecture.
SWRA1013 Dell EqualLogic PS Series Reference Architecture for Cisco Nexus 5020 7
Table 3 Switch settings used
Switch settings
Switch Model Cisco Nexus 5020
Switch inter-connection Dynamic Link Aggregation Group (LACP LAG)
Flow control enabled on each port channel group
Enable jumbo frames policy
Global Switch Settings Enable spanning-tree on edge-port
Individual Port Settings Enable jumbo frames policy
Set Layer 2 mode
Enable Port
Activate Flowcontrol
Switch Firmware 5.0(3)N2(2)
Host-Switch Cable Type Cisco 10G Active SFP-H10GB-CU3M
3 meter cable
Array-Switch Cable Type Array: SFP+ SR Optical Transceiver (DP/N 0N743D);
Switch: Cisco Nexus SFP SR Optical Transceiver (SFP-10G-SR,
10-2415-03)
LC-LC Fiber Optic Cable
Switch-Switch Cable Type Switch: Cisco Nexus SFP SR Optical Transceiver (SFP-10G-SR,
10-2415-03)
LC-LC Fiber Optic Cable
4.4.2 Global Switch Setting: Configure no-drop class and jumbo frames
To get flow control to properly work on the individual ports, you must configure a no-drop class and
also apply jumbo frames. The following CLI commands must be done on both switches.
SWRA1013 Dell EqualLogic PS Series Reference Architecture for Cisco Nexus 5020 8
sw1(config-cmap-nq)# match qos-group 2
5. Configure class-nodrop as no-drop class in network-qos policy-map and add jumbo frames
sw1(config-sys-qos)#
sw1(config)interface e1/1
SWRA1013 Dell EqualLogic PS Series Reference Architecture for Cisco Nexus 5020 9
mode. For this reference architecture, switch ports 0 through port 36 on each switch were used for
either server or array connections.
The following commands were used to configure the array and server ports on each switch.
sw1# configure
Enter configuration commands one per line. To end, press <Ctrl> <z>.
sw1(config-if)# exit
sw1(config-if-range)# exit
sw1(config)# exit
The following commands configure the single LAG used to interconnect the two Cisco Nexus 5020
switches. The commands must be run on each switch.
sw1# configure
Enter configuration commands one per line. To end, press <Ctrl> <z>.
sw1(config-if)# switchport
sw1(config-if)# exit
SWRA1013 Dell EqualLogic PS Series Reference Architecture for Cisco Nexus 5020 10
2. Add interfaces to port channel
sw1# configure
Enter configuration commands one per line. To end, press <Ctrl> <z>.
sw1(config)# exit
sw1# configure
Enter configuration commands one per line. To end, press <Ctrl> <z>.
sw1(config-if-range)# exit
sw1(config)# exit
sw1# configure
Enter configuration commands one per line. To end, press <Ctrl> <z>.
sw1(config-if)# exit
sw1# conf
SWRA1013 Dell EqualLogic PS Series Reference Architecture for Cisco Nexus 5020 11
sw1(config-if-range)# int po1
sw1(config-if)# exit
sw1(config)# exit
SWRA1013 Dell EqualLogic PS Series Reference Architecture for Cisco Nexus 5020 12
Appendix A Switch port mapping
Figure 2 shows the switch port mappings for the Cisco Nexus 5020 switch.
SWRA1013 Dell EqualLogic PS Series Reference Architecture for Cisco Nexus 5020 13
Appendix B TCP/IP configuration
Table 4 shows the TCP/IP configuration for the arrays.