Sie sind auf Seite 1von 85

MECHANICAL

VENTILATION WITH
HEAT RECOVERY
(MVHR)

IMPROVING
INDOOR
AIR QUALITY IN
NEW HOMES

1
NUAIRES PEDIGREE

Proud to Build British


Nuaire is a world leader in the design and
manufacture of fans and ventilation systems. We Based in South Wales,
put our energy into efficient ventilation so you dont our factory covers
waste yours. 18,000m2, allowing us to
manufacture almost all
Nuaire is a British company that designs and manufactures innovative of our products on site;
ventilation products for the residential and commercial sectors. We are from small bathroom
proud to be recognised for our expertise, commitment to innovation fans to large air
and the outstanding quality of our products and customer service. handling units.

Our people are at the heart of Nuaire, we have more than 400 In recent years Nuaire has
experienced staff based at our headquarters, with a further 65 invested millions of pounds
technical sales engineers throughout the UK and Ireland. into a new manufacturing
plant to supports its plans
for growth.

MADE IN
GREAT BRITAIN

Our manufacturing
facility is approximately
4 x the size of the
Wembley pitch

Nuaires technical application team


can offer expert advice and support to
help you make the right choice in your
ventilation strategy. Providing a simple,
quick selection or offering advice on
compliance with the very latest building
regulations and environmental issues, we
are here for you every step of the way.
GETTING IT
RIGHT FROM
THE START

2
Advice On
Compliance and SAP Q
Stay ahead of the latest building
regulations and make the best
product and fabric choices.

Over 65 Sales Staff


Field and office based
staff to support you at
every stage.

Gold Star Aftercare


Our comprehensive product
warranty and dedicated after sales
support gives you peace of mind.

The Full Service


Help with product selection,
detailed parts lists and fast delivery
ensure you meet your deadline
and budget.

3
NUAIRES MVHR

MECHANICAL
VENTILATION WITH
HEAT RECOVERY
(MVHR - System 4)
Heat recovery (MVHR) is fast becoming the most popular strategy for
effective whole home ventilation for new build properties.
A proven low-energy, highly efficient ventilation method, Nuaires heat The continuous revision of Government legislations and building
recovery MRXBOX range offers all year round ventilation by extracting regulations, in the pursuit of air-tight properties, are resulting in
moisture and supplying fresh air, whilst recovering the heat that would poor indoor air quality which in turn presents serious health hazards.
otherwise be lost. The MRXBOXAB range are also the first MVHR units
on the market with integral automatic summer bypass as standard. Nuaires award winning, wide range of MVHR solutions are up to
95% efficient and will quietly and effectively provide fresh, filtered
Nuaire offers the widest range of heat recovery systems in the UK, specifically air all year round. MVHR systems will retain heat that would have
designed to meet building regulations with the best SFPs/SAP Appendix Q otherwise been lost to atmosphere, and warm incoming fresh air
scores. With a range of compact ceiling and void mounted units designed,
Nuaire will have a unit to fit the requirements of your project.

MVHR How does it work?


HIGH EFFICIENCY
FILTERS HELP CREATE
NO NEED TO
A HEALTHY LIVING
OPEN WINDOWS
ENVIRONMENT
TO VENTILATE
Clean, fresh air passes through the
Clean fresh air is continuously
filter inside the unit and into the
drawn into the property
counter-flow heat exchanger, where
from outside through
it is warmed using the heat recovered
the intake air ducting.
from extract before it is delivered to
the habitable rooms of the home.

PREVENTS
CONDENSATION BY
BOOST FACILITY KEEPING MOISTURE
Both the supply and extract air LEVELS LOW
can be boosted at any time by Stale air is continuously extracted
the home owner to increase the from the moisture producing
ventilation levels. areas, such as kitchens and bathrooms.
Light switches, PIRs and The MVHR unit takes advantage
Humidistats can be used. of the heat by absorbing up
to 95% of it and storing it
in the heat exchanger.
4
All the options you need
Ventilation is often overlooked, or considered
late in the construction when joists and other
services are installed.

Nuaire offer a wide range of solutions, including MVHR units


that can be wall or ceiling mounted. Nuaire also offer acoustic
solutions to ensure you not only meet building regulations, but
have an efficient, whisper-quiet performance.

WALL VOID

Design Services
Nuaires Technical Application Team can
offer expert advice and support on design.

Services include 3D Revit designs which


illustrate your choice of product, ducting
and ancillaries. This bespoke package
enables correct selection and aids project
management and site control.

As well as a simple, clean system layout in


3D showing ventilation, Nuaire provides a
complete parts list with installation visuals.

5
NUAIRES MVHR

Building Regulations Part F

Location of Ventilation Devices


Table 5.1a Extract Ventilation Rates

Room Intermittent Continuous Extract Extract should be from each wet room. Air should normally be supplied
Extract to each habitable room. The total supply air flow should usually be
Minimum Rate Minimum High Rate Minimum Low Rate distributed in proportion to the habitable room volumes. Recirculation
Kitchen 30 l/s adjacent 13 l/s Total extract rate
by the system of moist air from the wet rooms to the habitable room
to hob, or should be at least should be avoided.
60 l/s elsewhere the whole dwelling
ventilation rate Mechanical extract terminals and fans should be installed as high as is
Utility Room 30 l/s 8 l/s given in Table 5.1b
practicable and preferably less than 400mm below the ceiling.
Bathroom 15 l/s 8 l/s

Sanitary 6 l/s 6 l/s Mechanical supply terminals should be located and directed to avoid
Accommodation draughts.

Where ducts etc. are provided in a dwelling with a protected stairway,


Table 5.1b Whole Dwelling Ventilation Rates precautions may be necessary to avoid the possibility of the system
Number of bedrooms in dwelling allowing smoke or fire to spread into the stairway. See Approved
1 2 3 4 5 Document B.

Whole dwelling ventilation rate a.b.


(l/s) 13 17 21 25 29 Background ventilators are not required with System 4.

Notes:
a. In addition, the minimum ventilation rates should be no less than 0.3 l/s per m2 of Air Transfer
internal floor area (this includes all floors, e.g. for a two-storey building, add the ground
and first floor areas).
To ensure good transfer of air throughout the dwelling, there should be an
undercut of minimum area 7600mm2 in all internal doors above the floor
b. This is based on two occupants in the main bedroom and a single occupant in all other
finish. This is equivalent to an undercut of 10mm for a standard 760mm
bedrooms. This should be used as the default value. If a greater level of occupancy is
expected, add 4 l/s per occupant. width door. This should be achieved by making an undercut of 10mm
above the floor finish if the floor finish is fitted, or by a 20mm undercut
above the floorboards, or other surface, if the finish has not been fitted.
Design of MVHR systems
System 4 has been sized for the winter period. Additional ventilation may be Controls
required during warmer months and it has been assumed that the provisions Should be set up to operate without occupant intervention, but may
for purge ventilation (e.g. openable windows) could be used.
have manual or automatic controls to select the boost rate. Any manual
Step 1: For any design air permeability, determine the whole dwelling boost controls should be provided locally to spaces being served, e.g.
ventilation supply rate from Table 5.1b. bathrooms and kitchen, as provision of a single centrally located switch
may result in fans being left in an inappropriate mode of operation.
As an alternative where the designed air permeability is intended to be leakier
than (>)5m /(h.m ) at 50 Pa, allow for infiltration for all dwelling types by
3 2 Automatic controls could include sensors for humidity, occupancy/usage
subtracting from the whole dwelling ventilation supply rate from Table 5.1b: and pollutant release. Humidity controls should not be used for sanitary
0.04 l/(s.m3) x gross internal volume of the dwelling heated space (m3) accommodation as odour is the main pollutant.

Step 2: Calculate the whole dwelling extract ventilation rate by summing the In kitchens, any automatic control must provide sufcient ow during
individual room rates for minimum high rate from Table 5.1a. cooking with fossil fuel (e.g. gas) to avoid build up of combustion products.

(For sanitary accommodation only, as an alternative, the purge ventilation Ensure that the system always provides the minimum whole dwelling
provisions given in Appendix B can be used where security is not an issue. ventilation rate specified in table 5.1b.
In this case the minimum high extract rate for sanitary accommodation
should be omitted from the Step 2 calculation.) Where manual controls are provided, they should be within reasonable
reach of the occupants. It is recommended that they are located in
Step 3: The required extract rates are as follows: accordance with the guidance of Requirement N3 Safe Opening And
The maximum whole dwelling extract ventilation rate (i.e. the boost rate) Closing of Windows etc., which is given in Approved Document N. Where
should be at least the greater of Step 1 and Step 2. Note that the maximumreasonable, pull cords, operating rods or similar devices should be provided.
individual room extract rates should be at least those given in Table 5.1a for
'minimum high rate'. Noise
Any continuously running fans should be quiet so as not to discourage their
The minimum whole dwelling extract ventilation rate should be at least the
use by occupants.
whole dwelling ventilation rate found in Step 1.

6
NUAIRES MVHR

MVHR Product Selector


LOW
WALL MOUNTED PROFILE

MRXBOX95-WM1/ MRXBOX95AB-WM1/ MRXBOX95-WM2/ MRXBOX95AB-WM2/ MRBOX95-WH1/ MRXBOX95AB-WH1/ MRXBOX95AB-WH2/ MRXBOX95B-LP1/


MRXBOX95-WM1-OH MRXBOX95AB-WM1-OH MRXBOX95-WM2-OH MRXBOX95AB-WM2-OH MRBOX95-WH1-OH MRXBOX95AB-WH1-OH MRXBOX95AB-WH2-OH MRXBOX95B-LP1-OH

Feature For properties up to For properties up to For properties up to For properties up to For properties up to For properties up to For properties up to For properties up to
70m2 / 753ft2 70m2 / 753ft2 150m2 / 1614ft2 150m2 / 1614ft2 185m2 / 1991ft2 185m2 / 1991ft2 250m2 / 2690ft2 150m2/ 1614ft2

Kitchen + up
to 1 wet
room

Kitchen +
up to 4 wet
rooms

Kitchen +
up to 6 wet
rooms

Kitchen +
up to 7 wet
rooms

Discreet Run
Monitor

Integral
automatic
summer
bypass

Integral frost
protection

Integral
humidistat

Optional
sensors and
detectors

Summertime
boost facility

MRXBOX-VSC
LCD Controller Coming soon
compatible

Silencer (SIL) Coming soon

First Fix (FF)

Thermal Bypass

7
MVHR Range
WALL MOUNTED

MRXBOX 95AB-
MRXBOX95-WM2-AE/ MRXBOX95AB-WM2-AE/ MRXBOX95-WM2-1Z/ MRXBOX95AB-WM2-1Z/ MRXBOX95-WH1-AE/ MRXBOX95AB-WH1-AE/ MRXBOX95-WH1-1Z/
WH1-1Z/
MRXBOX95-WM2- MRXBOX95AB-WM2- MRXBOX95-WM2- MRXBOX95AB-WM2- MRXBOX95-WH1- MRXBOX95AB-WH1- MRXBOX95-WH1-
MRXBOX 95AB-WH1-
AE-OH AE-OH 1Z-OH 1Z-OH AE-OH AE-OH 1Z-OH
1Z-OH

Feature For properties up to For properties up to For properties up to For properties up to For properties up to For properties up to For properties up to For properties up to
150m2/ 1614ft2 150m2/ 1614ft2 150m2/ 1614ft2 150m2/ 1614ft2 185m2 / 1991ft2 185m2 / 1991ft2 185m2 / 1991ft2 185m2 / 1991ft2

Kitchen + up to
1 wet room

Kitchen + up to
4 wet rooms

Kitchen + up to
6 wet rooms

Discreet Run
Monitor

Integral
automatic
summer bypass

Integral frost
protection

Integral
humidistat

Optional sensors
and detectors

Summertime
boost facility

MRXBOX-VSC
LCD Controller
compatible

Distribution
Box (DB)

Thermal Bypass

8
TOTAL CONTROL WITH
THE LIGHTEST TOUCH

...what a breath of fresh air


Simple, intuitive and discreet, the Nuaire LCD control - MRXBOX-VSC
puts you in total control of your MVHR system. With a wide range
of functions and settings, no other product gives you the freedom to
tailor performance, whilst saving energy.

For more details call 029 2085 8500


email enquiries@nuaire.co.uk
or visit www.nuaire.co.uk/residential

9
NUAIRES MVHR CONTROL

Touch Screen Controller for MVHR: MRXBOX-VSC


The stylish touch screen wired controller has
been designed to make controlling your MVHR DIMENSIONS
ventilation system simple, for both the installer 73mm = Screen width
and the end user.
35mm = Surface
mounting depth
With a 3.5 touch screen display, the unit can be surface or
semi-recess mounted and is compatible with a standard 2 gang
recess back box. 85mm

When installing the MVHR, you can commission the unit through
the controller and program settings such as air flow, frost protection
57mm =
and summer bypass.
Screen depth
For the end user, they will be able to tailor the unit to suit their 145mm
lifestyle, through setting a timed or rising boost, or even putting the
unit into holiday or night mode to save on energy.
6mm = Recessed
mounting depth

FLEXIBLE
CONTROL
OPTION

10
Consultants Specification
MRXBOX-VSC (Visual System Controller) Summer Bypass shall be opened via the MRXBOX-VSC manually
The MRXBOX-VSC is compatible with the majority of Nuaire for a set time (adjustable) after which time the MVHR system will
MRXBOX95 heat recovery units, the controller comes complete with return to normal function.
commissioning and end user functions. Time shall be adjusted and set via the MRXBOX-VSC if required.
The display will be a 3.5 inch LCD display and will remain on standby
MAINTENANCE
until such time the screen is touched.
Filter maintenance when filter replacement is required a symbol
The initial display will show the MVHR system status as listed below: will appear on the home screen. Under the Maintenance tab a QR
Current Fan Speed. code appears which offers a direct link to the Nuaire e-commerce
Current indoor/outside temperature. site where filters can be purchased online.
Indicate when the summer bypass is activated. User Guides shall be available via a QR code and web link
Indicate when frost protection is activated. displayed on the VSC if it is desirable to read the guides online.
Indicate when the filters require cleaning/changing.
Diagnostic shall be visible through to MRXBOX-VSC. The
COMMISSIONING diagnostic screen will list out the status of all working components
Commissioning shall only be available through a PIN access that will and indicate if there is a fault with a particular component.
be set up when the MRXBOX-VSC is first switched on. Run Time shall allow the Landlord/Service team (if applicable) to
Fan Speeds for both the supply and extract fan are set independently be able to determine how long the MVHR system has been running
and are infinitely variable, the display will show the percentage of and identify when the MVHR has not been running.
speed the fan is running at and will allow each fan to have 3 separate
saved speed set points to allow the MVHR unit to run at background
rate, boost rate and a further purge flow rate.
Summer Bypass can be set up via the MRXBOX-VSC. The controller
will allow the temperature to be altered to suit installation requirement.
This function is only available on the MRXBOX95AB range.
Humidity control shall be adjusted via the VSC from its default
position to suit the environment and home owner lifestyle. This
function is only available on the MRXBOX95AB range.
Frost protection temperature can be adjusted from the factory
default if required using the MRXBOX-VSC.
Run on time can be adjusted from 0-60 minutes via the MRXBOX-VSC.

USER CONTROLS
The MRXBOX-VSC shall allow the home owner/occupier to carry out
the following functions if desired.
Holiday Mode shall allow the owner/occupier to set the
ventilation rate to a minimum flow rate to conserve additional
energy while on holiday for up to 21 days (adjustable) after which
time the MVHR system will return back to normal function.
Night Mode shall allow the owner/occupier to set the ventilation
rate to a minimum at night if desired up to a maximum of 8 hours
(adjustable) after which time the MVHR system will return back to
normal function.
MVHR Boost shall allow the owner/occupier to boost the
MVHR ventilation rate for a set time (adjustable) after which the
ventilation system will return to is normal function. The MRXBOX-
VSC shall allow the owner/occupier to adjust the rate at which the
MVHR will boost.

11
NUAIRES MVHR

MRXBOX95AB-WM1 (with automatic summer bypass)


& MRXBOX95-WM1
The MRXBOX95AB-WM1 has been designed Sensors for the MRXBOX95(AB)WM1 include:
with automatic summer bypass and the facility MRXBOX95-PIR (Passive Infrared) - A low voltage sensor, detects
to commission the supply and extract fans movement and activates system. Incorporates overrun
timer and timer adjustments.
independently on both minimum and maximum
MRXBOX95-HUM (Humidity) - A low voltage sensor, activates the
speeds, in addition to the features you will find on
system when the RH (Relative Humidity) sensor level is above set
the standard MRXBOX95-WM1. point. Incorporates overrun timer and RH set point level adjustment.

Both the MRXBOX95AB-WM1 and MRXBOX95-WM1 are designed MRXBOX95-RFI (Remote Fail Indicator) - If fan failure occurs, the
to provide optimised balanced (supply and extract) mechanical audio visual indicator will flash a warning.
ventilation with heat recovery. Tempered air is delivered into living
areas whilst extracting moisture-laden air from wet areas, creating
comfortable well- ventilated homes. The unit uses the latest
generation of low voltage DC fans and motors, counter flow heat
exchanger and easy accessible controls. The heat exchanger block can
recover up to 95% of the normally wasted heat. The two independent
fans have full speed control for background and boost ventilation
rates, as well as a run-on timer facility. Both units are listed on the SAP
Product Characteristics Database.

Typical Installation
INSTALLATION FEATURES

Filter being removed

Filter Code
MVHR-WM1-FILTERKIT
Filter cover

12
Performance - MRXBOX95(AB)-WM1
CODE DESCRIPTION
350
MRXBOX95-WM1
300

250
1 2 3 4
1
1. Multi-room supply and extract heat recovery
Fan Static Pressure (Pa)

200
2. Product range
3. Efficiency
150
2 4. Wall/cupboard application
5. Medium duty
100
3

50
4
MRXBOX95AB -WM1
0
0 10 20 30 40 50 60
1 2 3 4 5 6
Air Volume Flow Rate (l/s)

1. Multi-room supply and extract heat recovery


2. Product range
3. Efficiency
4. Automatic Summer Bypass
5. Wall/cupboard application
6. Medium duty

Electrical & Sound


Maximum dBA
Frequency/Hz 63 125 250 500 1K 2K 4K 8K
power consumption @3m
Curve (Watts) Sound Power Levels dB re 1pW
1 71 Open inlet 45 41 48 47 41 39 24 24
Open Outlet 48 51 57 59 54 47 39 33
Breakout 51 50 53 51 43 38 30 26 33
2 36 Open inlet 43 39 45 43 36 34 19 19
Open Outlet 46 49 54 55 49 42 34 28
Breakout 49 48 50 47 38 33 25 21 26
3 15 Open inlet 42 37 42 39 30 28 <16 <16
Open Outlet 45 47 51 51 43 36 28 22
Breakout 48 46 47 43 32 27 19 <16 22
4 5 Open inlet 40 34 38 33 21 19 <16 <16
Open Outlet 43 44 47 45 34 27 19 <16
Breakout 46 43 43 37 23 18 <16 <16 17
The maximum power consumption shown above (Watts) is consumed on units running continuously, not taking into account any heat recovery saving and based on SAP Appendix
Q testing. The breakout case-radiated dBA values are given for Hemispherical free field radiation at 3m - to obtain the Spherical radiated data, subtract 3 dBA.

13
NUAIRES MVHR

SAP 2012 Test Results


MRXBOX95AB-WM1 MRXBOX95-WM1

Application Specific Fan Power Heat Exchange Energy Saving Specific Fan Power Heat Exchange Energy Saving
(W/l/s) Efficiency Trust Best Practice (W/l/s) Efficiency Trust Best Practice
Compliant Compliant

Kitchen + 1 Wet Room 0.91 86% Yes 0.72 92% Yes


Kitchen + 2 Wet Room 1.26 85% Yes 0.99 91% Yes

General Arrangement
SPIGOT LOCATION &
DUCTING REFERENCES

Spigot 1. 125mm dia. = Extract air from dwelling.


Spigot 2. 125mm dia. = Exhaust air to outside.
Spigot 3. 125mm dia. = Intake air from outside.
Spigot 4. 125mm dia. = Supply air to property.

Mounting Bracket on
wall and rear of unit

3 1

Two removable
G2 Filters

Condensate Tray

14
Technical - MRXBOX95(AB)-WM1
DIMENSIONS (mm)
Weight - 16kg

Front View Side View View from top

400
Filter
Access

79
468

288
130
100 125

79
79 400 124

603 288

Electrical Details
Please note: the electrical connection of the unit must be carried out
Detail of unit control on front panel.
by a qualified electrician.
The unit is supplied with a flexible cord for connection to the
mains supply.
NOTE: This unit must be earthed.
The mains power supply cable should be connected to a fixed wiring
installation, via a fused isolator, in accordance with current IEE Extract
Fan
Supply
Fan

wiring regulations. Extract


Fan Supply
Fan

Run on
Trickle
Boost
Trickle
Boost

Run on Trickle Boost Trickle Boost

ELECTRICAL DETAILS: MRXBOX95-WM1


Voltage: 230V 1ph 50Hz Tamper proof label following commissioning, includes system status indication.
Consumption: 75W - 0.6 Amp
Fuse rating: 3 Amp

15
NUAIRES MVHR

Wiring - MRXBOX95(AB)-WM1
DIMENSIONS
DIMENSIONS (MM)
(MM) && WEIGHT
WEIGHT UNIT
UNIT
UNIT SERVING KITCHEN & BATHROOM

Supply cord
N Green/Yellow from unit
L
MAINS
Blue
230V N
50Hz L Brown

Fuse 2A Room Black


light
3 Pole
Light isolator
switch
(Double Pole)

Kitchen switch

UNIT SERVING KITCHEN & TWO BATHROOMS


Supply cord
Green/Yellow from unit
MAINS
230V N Blue
50Hz L Brown
N Black
Fuse
L 2A Room
lights 3 Pole
Light
switches isolator
(Double Pole)

Kitchen switch

OPTIONAL SENSORS AND DETECTORS


Customise MRXBOX95AB-WM1 for enhanced
performance. All supplied with pre-plugged 10m data
cable and incorporates status LED.

MRXBOX95-PIR (Passive Infrared)


A low voltage sensor, detects movement
and activates system. Incorporates overrun
timer and timer adjustments.

MRXBOX95-HUM (Relative Humidity)


A low voltage sensor, activates the system
when the RH level is above set point. Incorporates
overrun timer and RH setpoint level adjustment.

MRXBOX95-RFI (Remote Fail Indicator)


If fan failure occurs the audio visual indicator
will flash a warning.

16
Consultants Specification
SPECIFICATION INTEGRAL AUTOMATIC SUMMER BYPASS
The unit shall be fully insulated providing excellent thermal and (MRXBOX95AB-WM1)
acoustic characteristics and shall be complete with a multi plate The bypass damper shall open automatically via a wax actuator,
counter flow high efficiency heat exchanger block, with a thermal allowing the air to bypass the heat exchanger to deliver fresh filtered
efficiency of up to 95%. The heat exchanger shall be protected air during the warmer months.
by G2 grade filters on fresh air inlet and system extract. The heat
exchanger and filters shall be accessible via the front access panel, CONTROL OPTIONS
enabling quick and easy maintenance. All versions shall have the following functions integrally mounted
The unit shall have low energy, high efficiency d.c. fan/motor within the fan unit on a purpose made PCB, all such components
assemblies with sealed for life bearings, the impellers shall be pre-wired and factory fitted by the manufacturer:
backward curved centrifugal type. The motors shall be suitable of Independent control of background supply and extract flow rates.
an ambient temperature of 40C. Independent control of boost speed supply and extract flow rates.
The unit shall be supplied complete with an insulated condensate Integral heat exchanger frost protection.
drip tray and 21.5mm drain connection. Integral adjustable run on timer.
Fan failure indication.
The unit shall be suitable for 125mm circular ducting. Integral S/L terminal for boost from remote switch, e.g. light switch.
Note: The unit is also available in opposite handed format, refer to Indication and controls The unit shall have clear LED visual
spigot configuration for set up. indication for maintenance, servicing and operation mode, i.e.
summer bypass, frost protection.
The breakout noise level and power requirements shall be as
detailed by the unit manufacturer and in accordance with the
ventilation equipment schedule.
Units shall be MRXBOX95-WM1 or MRXBOX95AB-WM1 as
manufactured by Nuaire and shall be listed on the SAP Appendix
Q database.

OPERATION
The supply and extract system shall be wall/cupboard mounted in
accordance with the specification.
The combined supply and extract with heat recovery unit shall
supply filtered fresh air to each of the habitable rooms and
moisture-laden air shall be extracted from all wet areas, e.g.
bathroom, en suite, w.c, kitchen, utility rooms etc. The supply air
shall be pre-heated by the warm extract air via the integrated
counter-flow heat exchanger element.
The ventilation unit shall vary its speed and therefore the
ventilation rate, as it receives signals from one of the following:
Switched live signal from light/remote switches.
Optional externally interconnected sensors.
When signals are received, the fan shall alter its speed to
adjustable, normal and boost rates.
An adjustable run-on facility is integrated into the unit which
allows the fans to run-on for between 1 and 60 minutes after the
signals have been switched off.
The unit shall have the facility to commission the supply and
extract fans independently on minimum speed (continuous
background ventilation), and boost speed, via inbuilt minimum and
maximum speed adjustment. The fans shall have infinitely variable
speed control.

17
NUAIRES MVHR

MRXBOX95AB-WM1-OH (with automatic summer bypass)


& MRXBOX95-WM1-OH
The MRXBOX95AB-WM1-OH has been designed Sensors for the MRXBOX95(AB)WM1-OH include:
with automatic summer bypass and the facility MRXBOX95-PIR (Passive Infrared) - A low voltage sensor, detects
to commission the supply and extract fans movement and activates system. Incorporates overrun timer and
timer adjustments.
independently on both minimum and maximum
MRXBOX95-HUM (Humidity) - A low voltage sensor, activates the
speeds, in addition to the features you will find on
system when the RH level is above set point. Incorporates overrun
the standard MRXBOX95-WM1-OH. timer and RH set point level adjustment.

Both the MRXBOX95AB-WM1-OH and MRXBOX95-WM1-OH MRXBOX95-RFI (Remote Fail Indicator) - If fan failure occurs, the
are designed to provide optimised balanced (supply and extract) audio visual indicator will flash a warning.
mechanical ventilation with heat recovery. Tempered air is delivered
into living areas whilst extracting moisture-laden air from wet areas,
creating comfortable well - ventilated homes. The unit uses the latest
generation of low voltage DC fans and motors, counter flow heat
exchanger and easy accessible controls. The heat exchanger block can
recover up to 95% of the normally wasted heat. The two independent
fans have full speed control for background and boost ventilation
rates, as well as a run-on timer facility. Both units are listed on the SAP
Product Characteristics Database.

Typical Installation
INSTALLATION FEATURES

Filter being removed

Filter Code
MVHR-WM1-FILTERKIT
Filter cover

18
Performance - MRXBOX95(AB)-WM1-OH
CODE DESCRIPTION
350
MRXBOX95-WM1-OH
300

250
1 2 3 4 5 6
1
Fan Static Pressure (Pa)

1. Multi-room supply and extract heat recovery


200
2. Product range
3. Efficiency
150
2
4. Wall/cupboard application
5. Medium duty
100
3 6. Opposite hand
50
4

0
MRXBOX95AB -WM1-OH
0 10 20 30 40 50 60
Air Volume Flow Rate (l/s)
1 2 3 4 5 6 7
1. Multi-room supply and extract heat recovery
2. Product range
3. Efficiency
4. Automatic Summer Bypass
5. Wall/cupboard application
6. Medium duty
7. Opposite hand

Electrical & Sound


Maximum dBA
Frequency/Hz 63 125 250 500 1K 2K 4K 8K
power consumption @3m
Curve (Watts) Sound Power Levels dB re 1pW
1 71 Open inlet 45 41 48 47 41 39 24 24
Open Outlet 48 51 57 59 54 47 39 33
Breakout 51 50 53 51 43 38 30 26 33
2 36 Open inlet 43 39 45 43 36 34 19 19
Open Outlet 46 49 54 55 49 42 34 28
Breakout 49 48 50 47 38 33 25 21 26
3 15 Open inlet 42 37 42 39 30 28 <16 <16
Open Outlet 45 47 51 51 43 36 28 22
Breakout 48 46 47 43 32 27 19 <16 22
4 5 Open inlet 40 34 38 33 21 19 <16 <16
Open Outlet 43 44 47 45 34 27 19 <16
Breakout 46 43 43 37 23 18 <16 <16 17
The maximum power consumption shown above (Watts) is consumed on units running continuously, not taking into account any heat recovery saving and based on SAP Appendix
Q testing. The breakout case-radiated dBA values are given for Hemispherical free field radiation at 3m - to obtain the Spherical radiated data, subtract 3 dBA.

19
NUAIRES MVHR

SAP 2012 Test Results


Product Code MRXBOX95AB-WM1-OH MRXBOX95-WM1-OH
SAP Identifier MRXBOX95AB-WM1 MRXBOX95-WM1
Application Specific Fan Power Heat Exchange Energy Saving Specific Fan Power Heat Exchange Energy Saving
(W/l/s) Efficiency Trust Best Practice (W/l/s) Efficiency Trust Best Practice
Compliant Compliant

Kitchen + 1 Wet Room 0.91 86% Yes 0.72 92% Yes


Kitchen + 2 Wet Room 1.26 85% Yes 0.99 91% Yes

General Arrangement
SPIGOT LOCATION &
DUCTING REFERENCES

Spigot 1. 125mm dia. = Intake air from outside.


Spigot 2. 125mm dia. = Supply air to property.
Spigot 3. 125mm dia. = Extract air from dwelling.
Spigot 4. 125mm dia. = Exhaust air to outside.

Mounting Bracket on
wall and rear of unit

3 1

Two removable
G2 Filters

20
Technical - MRXBOX95(AB)-WM1-OH
DIMENSIONS (mm)
Weight - 16kg

Front View Side View View from top

400
Filter
Access

79
468

288
130
100 125

79
79 400 124

603 288

Electrical Details
Please note: the electrical connection of the unit must be carried out
Detail of unit control on front panel.
by a qualified electrician.
The unit is supplied with a flexible cord for connection to the
mains supply.
NOTE: This unit must be earthed.
The mains power supply cable should be connected to a fixed wiring
installation, via a fused isolator, in accordance with current IEE Extract
Fan
Supply
Fan

wiring regulations. Extract


Fan Supply
Fan

Run on
Trickle
Boost
Trickle
Boost

Run on Trickle Boost Trickle Boost

ELECTRICAL DETAILS: MRXBOX95-WM1-OH


Voltage: 230V 1ph 50Hz Tamper proof label following commissioning, includes system status indication.
Consumption: 75W - 0.6 Amp
Fuse rating: 3 Amp

21
NUAIRES MVHR

Wiring - MRXBOX95(AB)-WM1-OH
DIMENSIONS
DIMENSIONS (MM)
(MM) && WEIGHT
WEIGHT UNIT
UNIT
UNIT SERVING KITCHEN & BATHROOM

Supply cord
N Green/Yellow from unit
L
MAINS
Blue
230V N
50Hz L Brown

Fuse 2A Room Black


light
3 Pole
Light isolator
switch
(Double Pole)

Kitchen switch

UNIT SERVING KITCHEN & TWO BATHROOMS


Supply cord
Green/Yellow from unit
MAINS
230V N Blue
50Hz L Brown
N Black
Fuse
L 2A Room
lights 3 Pole
Light
switches isolator
(Double Pole)

Kitchen switch

OPTIONAL SENSORS AND DETECTORS


Customise MRXBOX95AB-WM1-OH for enhanced
performance. All supplied with pre-plugged 10m data
cable and incorporates status LED.

MRXBOX95-PIR (Passive Infrared)


A low voltage sensor, detects movement
and activates system. Incorporates overrun
timer and timer adjustments.

MRXBOX95-HUM (Relative Humidity)


A low voltage sensor, activates the system
when the RH level is above set point. Incorporates
overrun timer and RH setpoint level adjustment.

MRXBOX95-RFI (Remote Fail Indicator)


If fan failure occurs the audio visual indicator
will flash a warning.

22
Consultants Specification
SPECIFICATION INTEGRAL AUTOMATIC SUMMER BYPASS
The unit shall be fully insulated providing excellent thermal and (MRXBOX95AB-WM1-OH)
acoustic characteristics and shall be complete with a multi plate The bypass damper shall open automatically via a wax actuator,
counter flow high efficiency heat exchanger block, with a thermal allowing the air to bypass the heat exchanger to deliver fresh filtered
efficiency of up to 95%. The heat exchanger shall be protected air during the warmer months.
by G2 grade filters on fresh air inlet and system extract. The heat
exchanger and filters shall be accessible via the front access panel, CONTROL OPTIONS
enabling quick and easy maintenance. All versions shall have the following functions integrally mounted
The unit shall have low energy, high efficiency d.c. fan/motor within the fan unit on a purpose made PCB, all such components
assemblies with sealed for life bearings, the impellers shall be pre-wired and factory fitted by the manufacturer:
backward curved centrifugal type. The motors shall be suitable of Independent control of background supply and extract flow rates.
an ambient temperature of 40C. Independent control of boost speed supply and extract flow rates.
The unit shall be supplied complete with an insulated condensate Integral heat exchanger frost protection.
drip tray and 21.5mm drain connection. Integral adjustable run on timer.
Fan failure indication.
The unit shall be suitable for 125mm circular ducting. Integral S/L terminal for boost from remote switch, e.g. light switch.
Note: The unit is also available in standard format, refer to spigot Indication and controls The unit shall have clear LED visual
configuration for set up. indication for maintenance, servicing and operation mode,
i.e. summer bypass, frost protection.
The breakout noise level and power requirements shall be as
detailed by the unit manufacturer and in accordance with the
ventilation equipment schedule.
Units shall be MRXBOX95-WM1-OH or MRXBOX95AB-WM1-
OH as manufactured by Nuaire and shall be listed on the SAP
Appendix Q database under product codes MRXBOX95-WM1 and
MRXBOX95AB-WM1 respectively.

OPERATION
The supply and extract system shall be wall/cupboard mounted in
accordance with the specification.
The combined supply and extract with heat recovery unit shall
supply filtered fresh air to each of the habitable rooms and
moisture-laden air shall be extracted from all wet areas, e.g.
bathroom, en suite, w.c, kitchen, utility rooms etc. The supply air
shall be pre-heated by the warm extract air via the integrated
counter-flow heat exchanger element.
The ventilation unit shall vary its speed and therefore the
ventilation rate, as it receives signals from one of the following:
Switched live signal from light/remote switches.
Optional externally interconnected sensors.
When signals are received, the fan shall alter its speed to
adjustable, normal and boost rates.
An adjustable run-on facility is integrated into the unit which
allows the fans to run-on for between 1 and 60 minutes after the
signals have been switched off.
The unit shall have the facility to commission the supply and
extract fans independently on minimum speed (continuous
background ventilation), and boost speed, via inbuilt minimum and
maximum speed adjustment. The fans shall have infinitely variable
speed control.

23
NUAIRES MVHR

MRXBOX95AB-WM2 (with automatic summer bypass)


& MRXBOX95-WM2
The MRXBOX95AB-WM2 has been designed
with automatic summer bypass and the facility
to commission the supply and extract fans
independently on both minimum and maximum
speeds, in addition to the features you will find on
the standard MRXBOX95-WM2.

Both the MRXBOX95AB-WM2 and MRXBOX95-WM2 are designed


to provide optimised balanced (supply and extract) mechanical
ventilation with heat recovery. Tempered air is delivered into living
areas whilst extracting moisture-laden air from wet areas, creating
comfortable well ventilated homes. The heat exchanger block can
recover up to 95% of the normally wasted heat. The two independent
fans have full speed control for background and boost ventilation
rates, as well as a run-on timer facility. Both units are listed on the SAP
Product Characteristics Database.

Typical Installation
INSTALLATION FEATURES

Filter being removed

Filter Code
MVHR-WM2-FILTERKIT
Filter cover

24
Performance - MRXBOX95(AB)-WM2
CODE DESCRIPTION
600
MRXBOX95-WM2
500
1 2 3 4

1 1. Multi-room supply and extract


400 heat recovery
2. Product range
3. Efficiency
Fan Static Pressure (Pa)

300 4. Wall/cupboard application


2 5. Medium duty

200

3
MRXBOX95AB-WM2
100
1 2 3 4 5 6
4

1. Multi-room supply and extract


0 heat recovery
0 20 40 60 80 100
2. Product range
Air Volume Flow Rate (l/s)
3. Efficiency
4. Automatic Summer Bypass
5. Wall/cupboard application
6. Medium duty

Electrical & Sound


Maximum dBA
Frequency/Hz 63 125 250 500 1K 2K 4K 8K
power consumption @3m
Curve (Watts) Sound Power Levels dB re 1pW
1 146 Open inlet 57 58 61 56 51 47 36 34
Open Outlet 55 65 71 67 64 60 51 43
Breakout 61 61 56 53 47 44 35 33 37
2 75 Open inlet 52 53 57 50 42 37 27 23
Open Outlet 54 60 63 60 57 54 42 34
Breakout 57 56 52 46 40 37 25 21 27
3 32 Open inlet 48 48 48 42 33 28 18 <16
Open Outlet 52 56 55 53 49 45 33 25
Breakout 53 54 47 39 34 30 16 <16 22
4 10 Open inlet 43 43 36 31 25 18 <16 <16
Open Outlet 51 51 47 46 41 34 23 16
Breakout 49 52 43 32 27 24 <16 <16 18
The maximum power consumption shown above (Watts) is consumed on units running continuously, not taking into account any heat recovery saving and based on SAP Appendix
Q testing. The breakout case-radiated dBA values are given for Hemispherical free field radiation at 3m - to obtain the Spherical radiated data, subtract 3 dBA.

25
NUAIRES MVHR

SAP 2012 Test Results


Product Code MRXBOX95AB-WM2 MRXBOX95-WM2
Application Specific Fan Power Heat Exchange Energy Saving Specific Fan Power Heat Exchange Energy Saving
(W/l/s) Efficiency Trust Best Practice (W/l/s) Efficiency Trust Best Practice
Compliant Compliant

Kitchen + 1 Wet Room 0.56 86% Yes 0.56 87% Yes


Kitchen + 2 Wet Room 0.66 85% Yes 0.68 87% Yes

Kitchen + 3 Wet Room 0.79 84% Yes 0.85 86% Yes

Kitchen + 4 Wet Room 1.02 83% Yes 1.06 86% Yes

Kitchen + 5 Wet Room 1.23 82% Yes Yes

General Arrangement
SPIGOT LOCATION &
DUCTING REFERENCES

Spigot 1. 125mm dia. = Extract air from dwelling.


Spigot 2. 125mm dia. = Exhaust air to outside.
Spigot 3. 125mm dia. = Intake air from outside.
Spigot 4. 125mm dia. = Supply air to property.

Mounting Bracket on
wall and rear of unit

3 1

Two removable
G3 Filters

Condensate Tray

26
Technical - MRXBOX95(AB)-WM2
DIMENSIONS (mm)
Weight - 20kg
Mounting
Front View Side View bracket View from top
416

16
123

90
172

172
507

Spigots
4x 125mm dia.

607 356

Electrical Details
Please note: the electrical connection of the unit must be carried out
Detail of unit control on front panel.
by a qualified electrician.
The unit is supplied with a flexible cord for connection to the
mains supply. Ventilation Controls Post commissioning remove
adhesive backing and seal

NOTE: This unit must be earthed.


Supply Extract
+ -
Fan + - + -
Fan + -
The mains power supply cable should be connected to a fixed wiring
installation, via a fused isolator, in accordance with current IEE wiring
Extract
Fan Supply
Fan

Run on
Trickle
Boost
Trickle
Boost

Power Fan
Trickle Boost Trickle Boost Failure

regulations.
061020

Tamper proof label following commissioning, includes system status indication.


ELECTRICAL DETAILS: MRXBOX95-WM2
Voltage: 230V 1ph 50Hz
Consumption: WM2 - 1.3 Amp
Fuse rating: 3 Amp

27
NUAIRES MVHR

Wiring - MRXBOX95(AB)-WM2
DIMENSIONS
UNIT SERVING(MM) & WEIGHT
KITCHEN UNIT
& BATHROOM

Supply cord
N Green/Yellow from unit
L
MAINS
Blue
230V N
50Hz L Brown

Fuse 2A Room Black


light
3 Pole Grey
Light isolator
switch
(Double Pole) Optional summer boost switch

Kitchen switch

UNIT SERVING KITCHEN & TWO BATHROOMS


Supply cord
Green/Yellow from unit
MAINS
230V N Blue
50Hz L Brown
N Black
Fuse
L 2A Room
lights 3 Pole Grey
Light
switches isolator
(Double Pole) Optional summer boost switch

Kitchen switch

OPTIONAL SENSORS AND DETECTORS


Customise MRBOX95(AB)-WM2 for enhanced
performance. All supplied with pre-plugged 10m data
cable and incorporates status LED.
MRXBOX-VSC
MRXBOX95-PIR (Passive Infrared) CONTROL SCREEN
A low voltage sensor, detects movement COMPATIBLE WITH
and activates system. Incorporates overrun THIS UNIT
timer and timer adjustments.

MRXBOX95-HUM (Relative Humidity)


A low voltage sensor, activates the system
when the RH level is above set point. Incorporates
overrun timer and RH setpoint level adjustment.

MRXBOX95-RFI (Remote Fail Indicator)


If fan failure occurs the audio visual indicator
will flash a warning.

28
Consultants Specification
SPECIFICATION INTEGRAL AUTOMATIC SUMMER BYPASS
The unit shall be fully insulated providing excellent thermal and (MRXBOX95AB-WM2)
acoustic characteristics and shall be complete with a multi plate The bypass damper shall open automatically via a wax actuator,
counter flow high efficiency heat exchanger block, with a thermal allowing the air to bypass the heat exchanger to deliver fresh filtered
efficiency of up to 95%. The heat exchanger shall be protected air during the warmer months.
by G3 grade filters on fresh air inlet and system extract. The heat
exchanger and filters shall be accessible via the front access panel, INTEGRAL HUMIDITY SENSOR
enabling quick and easy maintenance.
The integral humidity sensor incorporated within the extract fan
The unit shall have low energy, high efficiency EC fan/motor chamber will automatically boost both the extract and supply fan, to
assemblies with sealed for life bearings, the impellers shall be the commissioned boost speed, when the humidity level exceeds that
backward curved centrifugal type. The motors shall be suitable of set by the front panel mounted adjustment potentiometer.
an ambient temperature of 40C.
CONTROL OPTIONS
The unit shall be supplied complete with an insulated condensate
All versions shall have the following functions integrally mounted
drip tray and 21.5mm drain connection.
within the fan unit on a purpose made PCB, all such components
The unit shall be suitable for 125mm circular ducting. pre-wired and factory fitted by the manufacturer:

Note: The unit is also available in opposite handed format, refer to Independent control of background supply and extract flow rates.
spigot configuration for set up. Independent control of boost speed supply and extract flow rates.
Integral heat exchanger frost protection.
The breakout noise level and power requirements shall be as
Fan failure indication.
detailed by the unit manufacturer and in accordance with the
Integral S/L terminal for boost from remote switch, e.g. light switch.
ventilation equipment schedule.
Additional S/L terminal for 100% boost speed from remote switch,
Units shall be MRXBOX95-WM2 or MRXBOX95AB-WM2 as e.g. plate switch.
manufactured by Nuaire and shall be listed on the SAP Appendix Discreet daily run monitor.
Q database. Remote fail indicator (part number MRXBOX95-RFI)
Indication and controls The unit shall have clear LED visual
OPERATION indication for maintenance, servicing and operation mode,
The supply and extract system shall be positioned as indicated on i.e. summer bypass, frost protection.
the drawings and shall be in accordance with the particular fan
schedule in the specification. MRXBOX-VSC (VISUAL SYSTEM CONTROLLER)
The combined supply and extract with heat recovery unit shall The MRXBOX-VSC is compatible with the Nuaire MRXBOX95(AB)-WM2
supply filtered fresh air to each of the habitable rooms and heat recovery units and can be purchased separately. The controller
moisture-laden air shall be extracted from all wet areas, e.g. comes complete with commissioning and end user functions.
bathroom, en suite, w.c, kitchen, utility rooms etc. The supply air The display will be a 3.5 LCD display and will remain on standby until
shall be pre-heated by the warm extract air via the integrated such time the screen is touched.
counter-flow heat exchanger element. The extracted air shall also
be filtered before it reaches the heat exchanger block. The initial display will show the MVHR system status as listed below:

The ventilation unit shall vary its speed and therefore the Current Fan Speed.
ventilation rate, as it receives signals from one of the following: Current indoor/outside temperature.
Indicate when the summer bypass is activated.
Switched live signal from light/remote switches. Indicate when frost protection is activated.
When signals are received, the fan shall alter its speed to Indicate when the filters require cleaning/changing.
adjustable, normal and boost rates.
The unit shall have the facility to commission the supply and
extract fans independently on minimum speed (continuous
background ventilation), and boost speed, via inbuilt minimum and
maximum speed adjustment. The fans shall have infinitely variable
speed control.

29
NUAIRES MVHR

MRXBOX95AB-WM2-OH (with automatic summer bypass)


& MRXBOX95-WM2-OH
The MRXBOX95AB-WM2-OH has been designed
with automatic summer bypass and the facility
to commission the supply and extract fans
independently on both minimum and maximum
speeds, in addition to the features you will find on
the standard MRXBOX95-WM2-OH.

Both the MRXBOX95AB-WM2-OH and MRXBOX95-WM2-OH


are designed to provide optimised balanced (supply and extract)
mechanical ventilation with heat recovery. Tempered air is delivered
into living areas whilst extracting moisture-laden air from wet areas,
creating comfortable well ventilated homes. The heat exchanger
block can recover up to 95% of the normally wasted heat. The two
independent fans have full speed control for background and boost
ventilation rates, as well as a run-on timer facility. Both units are listed
on the SAP Product Characteristics Database.

Typical Installation
INSTALLATION FEATURES

Filter being removed

Filter Code
MVHR-WM2-FILTERKIT
Filter cover

30
Performance - MRXBOX95(AB)-WM2-OH
CODE DESCRIPTION
600
MRXBOX95-WM2-OH
500
1 2 3 4 5 6

1 1. Multi-room supply and extract


400 heat recovery
2. Product range
3. Efficiency
Fan Static Pressure (Pa)

300 4. Wall/cupboard application


2 5. Medium duty
6. Opposite hand
200

3
MRXBOX95AB-WM2-OH
100
1 2 3 4 5 6 7
4

1. Multi-room supply and extract


0 heat recovery
0 20 40 60 80 100
2. Product range
Air Volume Flow Rate (l/s)
3. Efficiency
4. Automatic Summer Bypass
5. Wall/cupboard application
6. Medium duty
7. Opposite hand

Electrical & Sound


Maximum dBA
Frequency/Hz 63 125 250 500 1K 2K 4K 8K
power consumption @3m
Curve (Watts) Sound Power Levels dB re 1pW
1 146 Open inlet 57 58 61 56 51 47 36 34
Open Outlet 55 65 71 67 64 60 51 43
Breakout 61 61 56 53 47 44 35 33 37
2 75 Open inlet 52 53 57 50 42 37 27 23
Open Outlet 54 60 63 60 57 54 42 34
Breakout 57 56 52 46 40 37 25 21 27
3 32 Open inlet 48 48 48 42 33 28 18 <16
Open Outlet 52 56 55 53 49 45 33 25
Breakout 53 54 47 39 34 30 16 <16 22
4 10 Open inlet 43 43 36 31 25 18 <16 <16
Open Outlet 51 51 47 46 41 34 23 16
Breakout 49 52 43 32 27 24 <16 <16 18
The maximum power consumption shown above (Watts) is consumed on units running continuously, not taking into account any heat recovery saving and based on SAP Appendix
Q testing. The breakout case-radiated dBA values are given for Hemispherical free field radiation at 3m - to obtain the Spherical radiated data, subtract 3 dBA.

31
NUAIRES MVHR

SAP 2012 Test Results


Product Code MRXBOX95AB-WM2-OH MRXBOX95-WM2-OH
SAP Identifier MRXBOX95AB-WM2 MRXBOX95-WM2
Application Specific Fan Power Heat Exchange Energy Saving Specific Fan Power Heat Exchange Energy Saving
(W/l/s) Efficiency Trust Best Practice (W/l/s) Efficiency Trust Best Practice
Compliant Compliant

Kitchen + 1 Wet Room 0.56 86% Yes 0.56 87% Yes


Kitchen + 2 Wet Room 0.66 85% Yes 0.68 87% Yes

Kitchen + 3 Wet Room 0.79 84% Yes 0.85 86% Yes

Kitchen + 4 Wet Room 1.02 83% Yes 1.06 86% Yes

Kitchen + 5 Wet Room 1.23 82% Yes Yes

General Arrangement
SPIGOT LOCATION &
DUCTING REFERENCES

Spigot 1. 125mm dia. = Intake air from outside.


Spigot 2. 125mm dia. = Supply air to property.
Spigot 3. 125mm dia. = Extract air from dwelling.
Spigot 4. 125mm dia. = Exhaust air to outside.

Mounting Bracket on
wall and rear of unit

3 1

Two removable
G3 Filters

32
Technical - MRXBOX95(AB)-WM2-OH
DIMENSIONS (mm)
Weight - 20kg
Mounting
Front View Side View bracket View from top
416

16
123

90
172

172
507

Spigots
4x 125mm dia.

607 356

Electrical Details
Please note: the electrical connection of the unit must be carried out Detail of unit control on front panel.
by a qualified electrician.
The unit is supplied with a flexible cord for connection to the
mains supply. Ventilation Controls Post commissioning remove
adhesive backing and seal

NOTE: This unit must be earthed. Supply


Fan +
Extract
Fan +
+ - - + - -

The mains power supply cable should be connected to a fixed wiring Run on
Extract
Fan

Trickle
Boost
Supply
Fan

Trickle

installation, via a fused isolator, in accordance with current IEE wiring


Boost

Power Fan
Trickle Boost Trickle Boost Failure
061020

regulations.
Tamper proof label following commissioning, includes system status indication.
ELECTRICAL DETAILS: MRXBOX95-WM2-OH
Voltage: 230V 1ph 50Hz
Consumption: WM2 - 1.3 Amp
Fuse rating: 3 Amp

33
NUAIRES MVHR

Wiring - MRXBOX95(AB)-WM2-OH
UNIT SERVING KITCHEN & BATHROOM

Supply cord
N Green/Yellow from unit
L
MAINS
Blue
230V N
50Hz L Brown

Fuse 2A Room Black


light
3 Pole Grey
Light isolator
switch
(Double Pole) Optional summer boost switch

Kitchen switch

UNIT SERVING KITCHEN & TWO BATHROOMS


Supply cord
Green/Yellow from unit
MAINS
230V N Blue
50Hz L Brown
N Black
Fuse
L 2A Room
lights 3 Pole Grey
Light
switches isolator
(Double Pole) Optional summer boost switch

Kitchen switch

OPTIONAL SENSORS AND DETECTORS


Customise MRBOX95(AB)-WM2-OH for enhanced
performance. All supplied with pre-plugged 10m data
cable and incorporates status LED.
MRXBOX-VSC
MRXBOX95-PIR (Passive Infrared) CONTROL SCREEN
A low voltage sensor, detects movement COMPATIBLE WITH
and activates system. Incorporates overrun THIS UNIT
timer and timer adjustments.

MRXBOX95-HUM (Relative Humidity)


A low voltage sensor, activates the system
when the RH level is above set point. Incorporates
overrun timer and RH setpoint level adjustment.

MRXBOX95-RFI (Remote Fail Indicator)


If fan failure occurs the audio visual indicator
will flash a warning.

34
Consultants Specification
SPECIFICATION INTEGRAL AUTOMATIC SUMMER BYPASS
The unit shall be fully insulated providing excellent thermal and (MRXBOX95AB-WM2-OH)
acoustic characteristics and shall be complete with a multi plate The bypass damper shall open automatically via a wax actuator,
counter flow high efficiency heat exchanger block, with a thermal allowing the air to bypass the heat exchanger to deliver fresh filtered
efficiency of up to 95%. The heat exchanger shall be protected air during the warmer months.
by G3 grade filters on fresh air inlet and system extract. The heat
exchanger and filters shall be accessible via the front access panel, INTEGRAL HUMIDITY SENSOR
enabling quick and easy maintenance.
The integral humidity sensor incorporated within the extract fan
The unit shall have low energy, high efficiency EC fan/motor chamber will automatically boost both the extract and supply fan, to
assemblies with sealed for life bearings, the impellers shall be the commissioned boost speed, when the humidity level exceeds that
backward curved centrifugal type. The motors shall be suitable of set by the front panel mounted adjustment potentiometer.
an ambient temperature of 40C.
CONTROL OPTIONS
The unit shall be supplied complete with an insulated condensate
All versions shall have the following functions integrally mounted
drip tray and 21.5mm drain connection.
within the fan unit on a purpose made PCB, all such components
The unit shall be suitable for 125mm circular ducting. pre-wired and factory fitted by the manufacturer:

Note: The unit is also available in standard format, refer to spigot Independent control of background supply and extract flow rates.
configuration for set up. Independent control of boost speed supply and extract flow rates.
Integral heat exchanger frost protection.
The breakout noise level and power requirements shall be as
Fan failure indication.
detailed by the unit manufacturer and in accordance with the
Integral S/L terminal for boost from remote switch, e.g. light switch.
ventilation equipment schedule.
Additional S/L terminal for 100% boost speed from remote switch,
Units shall be MRXBOX95-WM2-OH or MRXBOX95AB-WM2- e.g. plate switch.
OH as manufactured by Nuaire and shall be listed on the SAP Discreet daily run monitor.
Appendix Q database under product codes MRXBOX95-WM2 and Remote fail indicator (part number MRXBOX95-RFI).
MRXBOX95AB-WM2 respectively. Indication and controls The unit shall have clear LED visual
indication for maintenance, servicing and operation mode,
OPERATION i.e. summer bypass, frost protection.
The supply and extract system shall be positioned as indicated on
the drawings and shall be in accordance with the particular fan MRXBOX-VSC (VISUAL SYSTEM CONTROLLER)
schedule in the specification. The MRXBOX-VSC is compatible with the Nuaire MRXBOX95(AB)-
The combined supply and extract with heat recovery unit shall WM2-OH heat recovery units and can be purchased separately. The
supply filtered fresh air to each of the habitable rooms and controller comes complete with commissioning and end user functions.
moisture-laden air shall be extracted from all wet areas, e.g. The display will be a 3.5 LCD display and will remain on standby until
bathroom, en suite, w.c, kitchen, utility rooms etc. The supply air such time the screen is touched.
shall be pre-heated by the warm extract air via the integrated
counter-flow heat exchanger element. The extracted air shall also The initial display will show the MVHR system status as listed below:
be filtered before it reaches the heat exchanger block. Current Fan Speed.
The ventilation unit shall vary its speed and therefore the Current indoor/outside temperature.
ventilation rate, as it receives signals from one of the following: Indicate when the summer bypass is activated.
Indicate when frost protection is activated.
Switched live signal from light/remote switches. Indicate when the filters require cleaning/changing.
When signals are received, the fan shall alter its speed to
adjustable, normal and boost rates.
The unit shall have the facility to commission the supply and
extract fans independently on minimum speed (continuous
background ventilation), and boost speed, via inbuilt minimum and
maximum speed adjustment. The fans shall have infinitely variable
speed control.

35
NUAIRES MVHR

MRXBOX95AB-WH1 (with automatic summer bypass)


& MRXBOX95-WH1
The MRXBOX95AB-WH1 has been designed
with automatic summer bypass and the facility
to commission the supply and extract fans
independently on both minimum and maximum
speeds, in addition to the features you will find on
the standard MRXBOX95-WH1.

Both the MRXBOX95AB-WH1 and MRXBOX95-WH1 are designed


to provide optimised balanced (supply and extract) mechanical
ventilation with heat recovery. Tempered air is delivered into living
areas whilst extracting moisture-laden air from wet areas, creating
comfortable well ventilated homes. The heat exchanger block can
recover up to 95% of the normally wasted heat. The two independent
fans have full speed control for background and boost ventilation
rates, as well as a run-on timer facility. Both units are listed on the SAP
Product Characteristics Database.

Typical Installation
INSTALLATION FEATURES

Filter being removed

Filter Code
MVHR-WH1-FILTERKIT
Filter cover

36
Performance - MRBOX95(AB)-WH1
CODE DESCRIPTION
600
MRXBOX95-WH1
500
1 2 3 4 5
1. Multi-room supply and extract
400 heat recovery
2. Product range
3. Efficiency
Fan Static Pressure (Pa)

1
4. Wall/cupboard application
300
5. High 1 Model

2
200 MRXBOX95AB-WH1
3
100
1 2 3 4 5 6
1. Multi-room supply and extract
4
heat recovery
2. Product range
0
0 20 40 60 80 100 120 3. Efficiency
Air Volume Flow Rate (l/s) 4. Automatic Summer Bypass
5. Wall/cupboard application
6. High 1 Model

Electrical & Sound


Maximum dBA
Frequency/Hz 63 125 250 500 1K 2K 4K 8K
power consumption @3m
Curve (Watts) Sound Power Levels dB re 1pW
1 158 Open inlet 48 51 58 49 47 39 25 <16
Open Outlet 56 63 67 67 62 60 50 41
Breakout 56 61 59 53 43 40 25 <16 36
2 81 Open inlet 46 49 55 45 42 34 20 <16
Open Outlet 54 61 64 63 57 55 45 36
Breakout 54 59 56 49 38 35 20 <16 30
3 34 Open inlet 45 47 52 41 36 28 <16 <16
Open Outlet 53 59 61 59 51 49 39 30
Breakout 53 57 53 45 32 29 <16 <16 27
4 10 Open inlet 43 44 48 35 27 19 <16 <16
Open Outlet 51 56 57 53 42 40 30 21
Breakout 51 54 49 39 23 20 <16 <16 22
The maximum power consumption shown above (Watts) is consumed on units running continuously, not taking into account any heat recovery saving and based on SAP Appendix
Q testing. The breakout case-radiated dBA values are given for Hemispherical free field radiation at 3m - to obtain the Spherical radiated data, subtract 3 dBA.

37
NUAIRES MVHR

SAP 2012 Test Results


Product Code MRXBOX95AB-WH1 MRXBOX95-WH1
Application Specific Fan Power Heat Exchange Energy Saving Specific Fan Power Heat Exchange Energy Saving
(W/l/s) Efficiency Trust Best Practice (W/l/s) Efficiency Trust Best Practice
Compliant Compliant

Kitchen + 1 Wet Room 0.52 88% Yes 0.42 91% Yes


Kitchen + 2 Wet Room 0.56 88% Yes 0.50 91% Yes

Kitchen + 3 Wet Room 0.67 88% Yes 0.61 89% Yes

Kitchen + 4 Wet Room 0.78 86% Yes 0.75 88% Yes

Kitchen + 5 Wet Room 0.95 86% Yes 0.90 87% Yes

Kitchen + 6 Wet Room 1.16 85% Yes 1.05 85% Yes

Kitchen + 7 Wet Room 1.40 85% Yes Yes

General Arrangement
SPIGOT LOCATION &
DUCTING REFERENCES

Spigot 1. 150mm dia. = Extract air from dwelling.


Spigot 2. 150mm dia. = Exhaust air to outside.
Spigot 3. 150mm dia. = Intake air from outside.
Spigot 4. 150mm dia. = Supply air to property.

Mounting Bracket on
wall and rear of unit

3 1

Two removable
G3 Filters

Condensate Tray

38
Technical - MRBOX95(AB)-WH1
DIMENSIONS (mm)
MRXBOX95-WH1 - DIMENSIONS (mm)
Weight - 24kg

Front View Side View View from top

458

16
Mounting
bracket

120
123

226
226
623

Spigots
4x 150mm dia.

658 432

Electrical Details
Please note: the electrical connection of the unit must be carried out
Detail of unit control on front panel.
by a qualified electrician.
The unit is supplied with a flexible cord for connection to the
mains supply.
Ventilation Controls Post commissioning remove
adhesive backing and seal

NOTE: This unit must be earthed.


Supply Extract
Fan + Fan +
The mains power supply cable should be connected to a fixed + - - + - -

wiring installation, via a fused isolator, in accordance with current Run on


Extract
Fan

Trickle
Boost
Supply
Fan

Trickle
Boost

Power Fan
Trickle Boost Trickle Boost
IEE wiring regulations.
Failure
061020

Tamper proof label following commissioning, includes system status indication.


ELECTRICAL DETAILS: MRXBOX95-WH1
Voltage: 230V 1ph 50Hz
Consumption: WH1 - 1.3 Amp
Fuse rating: 3 Amp

39
NUAIRES MVHR

Wiring - MRBOX95(AB)-WH1
DIMENSIONS (MM) & WEIGHT UNIT
UNIT SERVING KITCHEN & BATHROOM

Supply cord
N Green/Yellow from unit
L
MAINS
Blue
230V N
50Hz L Brown

Fuse 2A Room Black


light
3 Pole Grey
Light isolator
switch
(Double Pole) Optional summer boost switch

Kitchen switch

UNIT SERVING KITCHEN & TWO BATHROOMS


Supply cord
Green/Yellow from unit
MAINS
230V N Blue
50Hz L Brown
N Black
Fuse
L 2A Room
lights 3 Pole Grey
Light
switches isolator
(Double Pole) Optional summer boost switch

Kitchen switch

OPTIONAL SENSORS AND DETECTORS


Customise MRBOX95(AB)-WH1 for enhanced
performance. All supplied with pre-plugged 10m data
cable and incorporates status LED.
MRXBOX-VSC
MRXBOX95-PIR (Passive Infrared)
CONTROL SCREEN
A low voltage sensor, detects movement
and activates system. Incorporates overrun COMPATIBLE WITH
timer and timer adjustments. THIS UNIT
MRXBOX95-HUM (Relative Humidity)
A low voltage sensor, activates the system
when the RH level is above set point. Incorporates
overrun timer and RH setpoint level adjustment.

MRXBOX95-RFI (Remote Fail Indicator)


If fan failure occurs the audio visual indicator
will flash a warning.

40
Consultants Specification
SPECIFICATION INTEGRAL AUTOMATIC SUMMER BYPASS
The unit shall be fully insulated providing excellent thermal and (MRXBOX95AB-WH1)
acoustic characteristics and shall be complete with a multi plate The bypass damper shall open automatically via a wax actuator,
counter flow high efficiency heat exchanger block, with a thermal allowing the air to bypass the heat exchanger to deliver fresh filtered
efficiency of up to 95%. The heat exchanger shall be protected air during the warmer months.
by G3 grade filters on fresh air inlet and system extract. The heat
exchanger and filters shall be accessible via the front access panel, INTEGRAL HUMIDITY SENSOR
enabling quick and easy maintenance. The integral humidity sensor incorporated within the extract fan
The unit shall have low energy, high efficiency EC fan/motor chamber will automatically boost both the extract and supply fan, to
assemblies with sealed for life bearings, the impellers shall be the commissioned boost speed, when the humidity level exceeds that
backward curved centrifugal type. The motors shall be suitable of set by the front panel mounted adjustment potentiometer.
an ambient temperature of 40C.
CONTROL OPTIONS
The unit shall be supplied complete with an insulated condensate All versions shall have the following functions integrally mounted
drip tray and 21.5mm drain connection. within the fan unit on a purpose made PCB, all such components
The unit shall be suitable for 150mm circular ducting. pre-wired and factory fitted by the manufacturer:

Note: The unit is also available in opposite handed format, refer to Independent control of background supply and extract flow rates.
spigot configuration for set up. Independent control of boost speed supply and extract flow rates.
Integral heat exchanger frost protection.
The breakout noise level and power requirements shall be as Fan failure indication.
detailed by the unit manufacturer and in accordance with the Integral S/L terminal for boost from remote switch, e.g. light switch.
ventilation equipment schedule. Additional S/L terminal for 100% boost speed from remote switch,
Units shall be MRXBOX95-WH1 or MRXBOX95AB-WH1 as e.g. plate switch.
manufactured by Nuaire and shall be listed on the SAP Appendix Discreet daily run monitor.
Q database. Remote fail indicator (part number MRXBOX95-RFI).
Indication and controls The unit shall have clear LED visual
OPERATION indication for maintenance, servicing and operation mode,
The supply and extract system shall be positioned as indicated on i.e. summer bypass, frost protection.
the drawings and shall be in accordance with the particular fan
schedule in the specification. MRXBOX-VSC (VISUAL SYSTEM CONTROLLER)
The combined supply and extract with heat recovery unit shall The MRXBOX-VSC is compatible with the Nuaire MRXBOX95(AB)-WH1
supply filtered fresh air to each of the habitable rooms and heat recovery units and can be purchased separately. The controller
moisture-laden air shall be extracted from all wet areas, e.g. comes complete with commissioning and end user functions.
bathroom, en suite, w.c, kitchen, utility rooms etc. The supply air The display will be a 3.5 LCD display and will remain on standby until
shall be pre-heated by the warm extract air via the integrated such time the screen is touched.
counter-flow heat exchanger element. The extracted air shall also
be filtered before it reaches the heat exchanger block. The initial display will show the MVHR system status as listed below:

The ventilation unit shall vary its speed and therefore the Current Fan Speed.
ventilation rate, as it receives signals from one of the following: Current indoor/outside temperature.
Indicate when the summer bypass is activated.
Switched live signal from light/remote switches. Indicate when frost protection is activated.
When signals are received, the fan shall alter its speed to Indicate when the filters require cleaning/changing.
adjustable, normal and boost rates.
The unit shall have the facility to commission the supply and
extract fans independently on minimum speed (continuous
background ventilation), and boost speed, via inbuilt minimum and
maximum speed adjustment. The fans shall have infinitely variable
speed control.

41
NUAIRES MVHR

MRXBOX95AB-WH1-OH (with automatic summer bypass)


& MRXBOX95-WH1-OH
The MRXBOX95AB-WH1-OH has been designed
with automatic summer bypass and the facility
to commission the supply and extract fans
independently on both minimum and maximum
speeds, in addition to the features you will find on
the standard MRXBOX95-WH1-OH.

Both the MRXBOX95AB-WH1-OH and MRXBOX95-WH1-OH


are designed to provide optimised balanced (supply and extract)
mechanical ventilation with heat recovery. Tempered air is delivered
into living areas whilst extracting moisture-laden air from wet areas,
creating comfortable well ventilated homes. The heat exchanger
block can recover up to 95% of the normally wasted heat. The two
independent fans have full speed control for background and boost
ventilation rates, as well as a run-on timer facility. Both units are listed
on the SAP Product Characteristics Database.

Typical Installation
INSTALLATION FEATURES

Filter being removed

Filter Code
MVHR-WH1-FILTERKIT
Filter cover

42
Performance - MRBOX95(AB)-WH1-OH
CODE DESCRIPTION
600
MRXBOX95-WH1-OH
500
1 2 3 4 5 6
1. Multi-room supply and extract
400 heat recovery
2. Product range
3. Efficiency
Fan Static Pressure (Pa)

1
4. Wall/cupboard application
300
5. High 1 Model
6. Opposite hand
2
200

3
100
MRXBOX95AB-WH1-OH
4

0 1 2 3 4 5 6 7
0 20 40 60 80 100 120
1. Multi-room supply and extract
Air Volume Flow Rate (l/s)
heat recovery
2. Product range
3. Efficiency
4. Automatic Summer Bypass
5. Wall/cupboard application
6. High 1 Model
7. Opposite hand

Electrical & Sound


Maximum dBA
Frequency/Hz 63 125 250 500 1K 2K 4K 8K
power consumption @3m
Curve (Watts) Sound Power Levels dB re 1pW
1 158 Open inlet 48 51 58 49 47 39 25 <16
Open Outlet 56 63 67 67 62 60 50 41
Breakout 56 61 59 53 43 40 25 <16 36
2 81 Open inlet 46 49 55 45 42 34 20 <16
Open Outlet 54 61 64 63 57 55 45 36
Breakout 54 59 56 49 38 35 20 <16 30
3 34 Open inlet 45 47 52 41 36 28 <16 <16
Open Outlet 53 59 61 59 51 49 39 30
Breakout 53 57 53 45 32 29 <16 <16 27
4 10 Open inlet 43 44 48 35 27 19 <16 <16
Open Outlet 51 56 57 53 42 40 30 21
Breakout 51 54 49 39 23 20 <16 <16 22
The maximum power consumption shown above (Watts) is consumed on units running continuously, not taking into account any heat recovery saving and based on SAP Appendix
Q testing. The breakout case-radiated dBA values are given for Hemispherical free field radiation at 3m - to obtain the Spherical radiated data, subtract 3 dBA.

43
NUAIRES MVHR

SAP 2012 Test Results


Product Code MRXBOX95AB-WH1-OH MRXBOX95-WH1-OH
SAP Identifier MRXBOX95AB-WH1 MRXBOX95-WH1
Application Specific Fan Power Heat Exchange Energy Saving Specific Fan Power Heat Exchange Energy Saving
(W/l/s) Efficiency Trust Best Practice (W/l/s) Efficiency Trust Best Practice
Compliant Compliant

Kitchen + 1 Wet Room 0.52 88% Yes 0.42 91% Yes


Kitchen + 2 Wet Room 0.56 88% Yes 0.50 91% Yes

Kitchen + 3 Wet Room 0.67 88% Yes 0.61 89% Yes

Kitchen + 4 Wet Room 0.78 86% Yes 0.75 88% Yes

Kitchen + 5 Wet Room 0.95 86% Yes 0.90 87% Yes

Kitchen + 6 Wet Room 1.16 85% Yes 1.05 85% Yes

Kitchen + 7 Wet Room 1.40 85% Yes Yes

General Arrangement
SPIGOT LOCATION &
DUCTING REFERENCES

Spigot 1. 150mm dia. = Intake air from outside.


Spigot 2. 150mm dia. = Supply air to property.
Spigot 3. 150mm dia. = Extract air from dwelling.
Spigot 4. 150mm dia. = Exhaust air to outside. Mounting Bracket on
wall and rear of unit

3 1

Two removable
G3 Filters

44
Technical - MRBOX95(AB)-WH1-OH
DIMENSIONS (mm)
MRXBOX95-WH1 - DIMENSIONS (mm)
Weight - 24kg

View from front with cover removed Side View View from top

458

16
Mounting
bracket

120
123

226
226
623

Spigots
4x 150mm dia.

658 432

Electrical Details
Please note: the electrical connection of the unit must be carried out
by a qualified electrician. Detail of unit control on front panel.

The unit is supplied with a flexible cord for connection to the


mains supply.
Ventilation Controls Post commissioning remove
adhesive backing and seal
NOTE: This unit must be earthed.
Supply Extract
The mains power supply cable should be connected to a fixed + -
Fan + - + -
Fan + -

wiring installation, via a fused isolator, in accordance with current Run on


Extract
Fan

Trickle
Boost
Supply
Fan

Trickle
Boost

Power Fan
IEE wiring regulations. Trickle Boost Trickle Boost Failure
061020

Tamper proof label following commissioning, includes system status indication.


ELECTRICAL DETAILS: MRXBOX95-WH1-OH
Voltage: 230V 1ph 50Hz
Consumption: WH1 - 1.3 Amp
Fuse rating: 3 Amp

45
NUAIRES MVHR

Wiring - MRBOX95(AB)-WH1-OH
DIMENSIONS (MM) & WEIGHT UNIT
UNIT SERVING KITCHEN & BATHROOM

Supply cord
N Green/Yellow from unit
L
MAINS
Blue
230V N
50Hz L Brown

Fuse 2A Room Black


light
3 Pole Grey
Light isolator
switch
(Double Pole) Optional summer boost switch

Kitchen switch

UNIT SERVING KITCHEN & TWO BATHROOMS


Supply cord
Green/Yellow from unit
MAINS
230V N Blue
50Hz L Brown
N Black
Fuse
L 2A Room
lights 3 Pole Grey
Light
switches isolator
(Double Pole) Optional summer boost switch

Kitchen switch

OPTIONAL SENSORS AND DETECTORS


Customise MRBOX95(AB)-WH1-OH for enhanced
performance. All supplied with pre-plugged 10m data
cable and incorporates status LED.
MRXBOX-VSC
MRXBOX95-PIR (Passive Infrared)
CONTROL SCREEN
A low voltage sensor, detects movement
and activates system. Incorporates overrun COMPATIBLE WITH
timer and timer adjustments. THIS UNIT
MRXBOX95-HUM (Relative Humidity)
A low voltage sensor, activates the system
when the RH level is above set point. Incorporates
overrun timer and RH setpoint level adjustment.

MRXBOX95-RFI (Remote Fail Indicator)


If fan failure occurs the audio visual indicator
will flash a warning.

46
Consultants Specification
SPECIFICATION INTEGRAL AUTOMATIC SUMMER BYPASS
The unit shall be fully insulated providing excellent thermal and (MRXBOX95AB-WH1-OH)
acoustic characteristics and shall be complete with a multi plate The bypass damper shall open automatically via a wax actuator,
counter flow high efficiency heat exchanger block, with a thermal allowing the air to bypass the heat exchanger to deliver fresh filtered
efficiency of up to 95%. The heat exchanger shall be protected air during the warmer months.
by G3 grade filters on fresh air inlet and system extract. The heat
exchanger and filters shall be accessible via the front access panel, INTEGRAL HUMIDITY SENSOR
enabling quick and easy maintenance. The integral humidity sensor incorporated within the extract fan
The unit shall have low energy, high efficiency EC fan/motor chamber will automatically boost both the extract and supply fan, to
assemblies with sealed for life bearings, the impellers shall be the commissioned boost speed, when the humidity level exceeds that
backward curved centrifugal type. The motors shall be suitable of set by the front panel mounted adjustment potentiometer.
an ambient temperature of 40C.
CONTROL OPTIONS
The unit shall be supplied complete with an insulated condensate All versions shall have the following functions integrally mounted
drip tray and 21.5mm drain connection. within the fan unit on a purpose made PCB, all such components
The unit shall be suitable for 150mm circular ducting. pre-wired and factory fitted by the manufacturer:

Note: The unit is also available in standard format, refer to spigot Independent control of background supply and extract flow rates.
configuration for set up. Independent control of boost speed supply and extract flow rates.
Integral heat exchanger frost protection.
The breakout noise level and power requirements shall be as Fan failure indication.
detailed by the unit manufacturer and in accordance with the Integral S/L terminal for boost from remote switch, e.g. light switch.
ventilation equipment schedule. Additional S/L terminal for 100% boost speed from remote
Units shall be MRXBOX95-WH1-OH or MRXBOX95AB-WH1- switch, e.g. plate switch.
OH as manufactured by Nuaire and shall be listed on the SAP Discreet daily run monitor.
Appendix Q database under product codes MRXBOX95-WH1 and Remote fail indicator (part number MRXBOX95-RFI).
MRXBOX95AB-WH1 respectively. Indication and controls The unit shall have clear LED visual
indication for maintenance, servicing and operation mode,
OPERATION i.e. summer bypass, frost protection.
The supply and extract system shall be positioned as indicated on
the drawings and shall be in accordance with the particular fan MRXBOX-VSC (VISUAL SYSTEM CONTROLLER)
schedule in the specification. The MRXBOX-VSC is compatible with the Nuaire MRXBOX95(AB)-WH1-
OH heat recovery units and can be purchased separately. The controller
The combined supply and extract with heat recovery unit shall
comes complete with commissioning and end user functions.
supply filtered fresh air to each of the habitable rooms and
moisture-laden air shall be extracted from all wet areas, e.g. The display will be a 3.5 LCD display and will remain on standby until
bathroom, en suite, w.c, kitchen, utility rooms etc. The supply air such time the screen is touched.
shall be pre-heated by the warm extract air via the integrated
The initial display will show the MVHR system status as listed below:
counter-flow heat exchanger element. The extracted air shall also
be filtered before it reaches the heat exchanger block. Current Fan Speed.
Current indoor/outside temperature.
The ventilation unit shall vary its speed and therefore the
Indicate when the summer bypass is activated.
ventilation rate, as it receives signals from one of the following:
Indicate when frost protection is activated.
Switched live signal from light/remote switches. Indicate when the filters require cleaning/changing.

When signals are received, the fan shall alter its speed to
adjustable, normal and boost rates.
The unit shall have the facility to commission the supply and
extract fans independently on minimum speed (continuous
background ventilation), and boost speed, via inbuilt minimum and
maximum speed adjustment. The fans shall have infinitely variable
speed control.

47
NUAIRES MVHR

MRXBOX95AB-WH2 (with automatic summer bypass)


The MRXBOX95AB-WH2 has been designed with
automatic summer bypass and the facility to
commission the supply and extract fans independently
on both minimum and maximum speeds.

This unit is designed to provide optimised balanced (supply and extract)


mechanical ventilation with heat recovery, with a heat exchanger block
that can recover up to 95% of the normally wasted heat. Tempered
air is delivered into living areas whilst extracting moisture laden air
from wet areas, creating comfortable well-ventilated homes. The two
independent fans have full speed control for background and boost
ventilation rates, as well as a run-on timer facility. This unit is listed on
the SAP Product Characteristics Database.

Typical Installation
INSTALLATION FEATURES

Filter being removed

Filter Code
MVHR-WH2-FILTERKIT
Filter cover

Typical cupboard installation of MRXBOX95AB-WH2

48
Performance - MRXBOX95AB-WH2
CODE DESCRIPTION
1250
MRXBOX95AB-WH2
1000

1 2 3 4 5 6
Fan Static Pressure (Pa)

750
1. Multi-room supply and extract
1 heat recovery
500 2. Product range
2 3. Efficiency
250
4. Automatic Summer Bypass
3
5. Wall/cupboard application
4
6. High 2 Model
0
0 20 40 60 80 100 120 140 160 180 200
Air Volume Flow Rate (l/s)

Electrical & Sound


Maximum dBA
Frequency/Hz 63 125 250 500 1K 2K 4K 8K
power consumption @3m
Curve (Watts) Sound Power Levels dB re 1pW
1 341 Open inlet 58 56 57 63 57 51 46 45
Open Outlet 67 63 65 75 68 63 56 53
Breakout 61 61 60 63 53 48 40 35 44
2 173 Open inlet 56 54 54 59 52 46 41 40
Open Outlet 65 61 62 71 63 58 51 48
Breakout 59 59 57 59 48 43 35 30 37
3 73 Open inlet 55 52 51 55 45 39 34 33
Open Outlet 64 59 59 67 56 51 44 41
Breakout 58 57 54 55 41 36 28 23 32
4 21 Open inlet 53 49 47 49 37 31 26 25
Open Outlet 62 56 55 61 48 48 36 33
Breakout 56 54 50 49 33 28 20 <16 27
The maximum power consumption shown above (Watts) is consumed on units running continuously, not taking into account any heat recovery saving and based on SAP Appendix
Q testing. The breakout case-radiated dBA values are given for Hemispherical free field radiation at 3m - to obtain the Spherical radiated data, subtract 3 dBA.

49
SAP 2012 Test Results
Product Code MRXBOX95AB-WH2
Application Specific Fan Power Heat Exchange Energy Saving Trust Best
(W/l/s) Efficiency Practice Compliant

Kitchen + 1 Wet Room 0.60 89% Yes


Kitchen + 2 Wet Room 0.61 88% Yes
Kitchen + 3 Wet Room 0.68 88% Yes
Kitchen + 4 Wet Room 0.79 87% Yes
Kitchen + 5 Wet Room 0.95 86% Yes
Kitchen + 6 Wet Room 1.15 85% Yes
Kitchen + 7 Wet Room 1.38 85% Yes

General Arrangement
SPIGOT LOCATION &
DUCTING REFERENCES

Spigot 1. 200mm dia. = Extract air from dwelling.


Spigot 2. 200mm dia. = Exhaust air to outside.
Spigot 3. 200mm dia. = Intake air from outside.
Spigot 4. 200mm dia. = Supply air to property.

Mounting Bracket on
wall and rear of unit

Two removable
G3 Filters

Condensate Tray

50
Technical - MRXBOX95AB-WH2
DIMENSIONS (mm)
Weight - 44Kg

View from top


485

= = Ecosmart connection grommets

4 x Spigots
180mm Internal Diameter
139

200mm External Diameter


290

Dimensions: Unit wall mounting bracket position


(Viewed from back)
Front view Side view
Mounting
= =

200
176
710

5 Fixing Bracket to
Points be fitted to
534

the wall

710 585 40.0 CRS 40.0 CRS


492 CRS
67 67

Electrical Details - MRXBOX95AB-WH2


Please note: the electrical connection of the unit must be carried out
Detail of unit control on front panel.
by a qualified electrician.
The unit is supplied with a flexible cord for connection to the mains supply.
NOTE: In the event of 1kV transients the fans may stop running,
normal operation will be resumed when the interference has ceased.
The mains power supply cable should be connected to a fixed
wiring installation, via a fused isolator, in accordance with current
For commissioning:

IEE wiring regulations. Ventilation Controls refer to user manual

Post commissioning remove


adhesive backing under
this section
+ - + - + - + - + - + -
ELECTRICAL DETAILS: MRXBOX95AB-WH2
Voltage: 230V 1ph 50Hz Power

060905

Consumption: 2.5 Amp


Tamper proof label following commissioning, includes system status indication.
Fuse rating: 5 Amp

51
NUAIRES MVHR

Wiring
Note: Wiring is N
for reference purposes only as the connections are factory fitted. The unit is pre-wired with a 2 metre fly lead.
L
UNIT SERVING KITCHEN & BATHROOM
N
L Green/Yellow
MAINS
Blue
230V N
50Hz L Brown

Fuse 5A 2 Pole Black


Isolator 1
L
Grey
2

3 Position Switch Supply cord


Ancillary code: from unit
MRXBOX95-3SWITCH
N
UNIT SERVING ONE BATHROOM
L Green/Yellow
MAINS
Blue
230V N
50Hz Brown
L
Fuse 5A Room Black
N light 1
Light 3 Pole L
L Isolator 2
Grey
switch
(Double
Pole) 3 Position Switch Supply cord
Ancillary code: from unit
MRXBOX95-3SWITCH

UNIT SERVING TWO BATHROOMS


MAINS
230V N
50Hz
L
Room
Fuse 5A lights
N 3 Pole L 1
Light
L switch Isolator 2
(Double
N Pole)
L 3 Position Switch Supply cord
Ancillary code: from unit
MRXBOX95-3SWITCH

OPTIONAL SENSORS AND DETECTORS


Customise MRBOX95AB-WH2 for enhanced
performance. All supplied with pre-plugged 10m data
cable and incorporates status LED. MRXBOX-VSC
MRXBOX95-PIR (Passive Infrared) Coming soon
A low voltage sensor, detects movement with this unit!
and activates system. Incorporates overrun
timer and timer adjustments.

MRXBOX95-HUM (Relative Humidity)


A low voltage sensor, activates the system
when the RH level is above set point. Incorporates
overrun timer and RH setpoint level adjustment.

MRXBOX95-RFI (Remote Fail Indicator)


If fan failure occurs the audio visual indicator
will flash a warning.

52
Consultants Specification
MRXBOX95AB-WH2 SPECIFICATION INTEGRAL HUMIDITY SENSOR
The unit shall be fully insulated providing excellent thermal and The integral humidity sensor incorporated within the extract fan
acoustic characteristics and shall be complete with a multi plate chamber will automatically boost both the extract and supply fan, to
counter flow high efficiency heat exchanger block, with a thermal the commissioned boost speed, when the humidity level exceeds that
efficiency of up to 95%. The heat exchanger shall be protected by G3 set by the side panel mounted adjustment potentiometer.
grade filters on fresh air inlet and system extract.
OPTIONAL REMOTE SWITCH
The heat exchanger and filters shall be accessible via the front access (MRXBOX95-3 SWITCH)
panel, enabling quick and easy maintenance.
The unit shall have the facility to wire a three position remote switch to
The unit shall have low energy, high efficiency EC fan/motor a suitable location within the property. The switch shall have 3 settings,
assemblies with sealed for life bearings, the impellers shall be trickle, boost and summertime boost facility. The remote switch will
backward curved centrifugal type. act as the master switch and will override all other switches.
The motors shall be suitable of an ambient temperature of 40C. CONTROL OPTIONS
The unit shall be supplied complete with a condensate drip tray and All versions shall have the following functions integrally mounted
32mm drain connection. within the fan unit on a purpose made PCB, all such components pre-
wired and factory fitted by the manufacturer:
The unit shall be suitable for 200mm diameter circular ducting.
Independent control of background supply and extract flow rates.
Note: The unit is also available in opposite handed format, refer to
Independent control of boost speed supply and extract flow rates.
spigot configuration for set up.
Integral fan failure indication.
The breakout noise level and power requirements shall be as detailed Integral S/L terminal for boost to commissioned level, from remote
by the unit manufacturer and in accordance with the ventilation switch, e.g. light switch.
equipment schedule. Integral S/L terminal for summertime boost speed, from remote
switch e.g. plate switch.
The unit shall be MRXBOX95AB-WH2 as manufactured by Nuaire
Integral heat exchanger frost protection.
and shall be listed on the SAP Appendix Q database.
Discreet daily run monitor.
OPERATION Remote fail indicator (Part number-MRXBOX95-RFI).
The supply and extract ventilation unit shall be positioned as Indication and controls - The unit shall have clear LED visual
indicated on the drawings and shall be in accordance with the indication for maintenance, servicing and operation mode i.e.
particular fan schedule in the specification. summer bypass, frost protection.

The combined supply and extract with heat recovery unit shall supply The unit shall be offered with a 5 year warranty.
filtered fresh air to each of the habitable rooms and moisture-laden The manufacturers recommendations should be observed at all
air shall be extracted from the wet areas e.g. bathroom, en-suite, w.c, times. The unit shall be the MRXBOX95AB-WH2 and shall be
kitchen, utility rooms, etc. The supply air shall be pre-heated by the warm manufactured by Nuaire.
extract air via the integrated counter-flow heat exchanger element.
The extracted air shall also be filtered before it reaches the heat
exchanger block. The ventilation unit shall vary its speed and therefore
the ventilation rate, as it receives signals from one of the following:
Switched live signal from light/remote switches.
When signals are received, the fan shall alter its speed to adjustable,
normal and boost rates.
The unit shall have the facility to commission the supply and extract
fans independently on minimum speed (continuous background
ventilation), boost speed, via inbuilt minimum and maximum speed
adjustment. The fans shall have infinitely variable speed control.

INTEGRAL AUTOMATIC SUMMER BYPASS


The bypass damper shall open automatically via a wax actuator
allowing the air to bypass the heat exchanger to deliver fresh filtered
air during the warmer months.

53
NUAIRES MVHR

MRXBOX95AB-WH2-OH (with automatic summer bypass)


The MRXBOX95AB-WH2-OH has been designed
with automatic summer bypass and the facility to
commission the supply and extract fans independently
on both minimum and maximum speeds.

This unit is designed to provide optimised balanced (supply and extract)


mechanical ventilation with heat recovery, with a heat exchanger block
that can recover up to 95% of the normally wasted heat. Tempered
air is delivered into living areas whilst extracting moisture-laden air
from wet areas, creating comfortable well-ventilated homes. The two
independent fans have full speed control for background and boost
ventilation rates, as well as a run-on timer facility. This unit is listed on
the SAP Product Characteristics Database.

Typical Installation
INSTALLATION FEATURES

Filter being removed

Filter Code
MVHR-WH2-FILTERKIT
Filter cover

Typical cupboard installation of MRXBOX95AB-WH2

54
Performance - MRXBOX95AB-WH2-OH
CODE DESCRIPTION
1250
MRXBOX95AB-WH2-OH
1000

1 2 3 4 5 6 7
Fan Static Pressure (Pa)

750
1. Multi-room supply and extract
1 heat recovery
500 2. Product range
2 3. Efficiency
250
4. Automatic Summer Bypass
3
5. Wall/cupboard application
4
6. High 2 Model
0
0 20 40 60 80 100 120 140 150 160 180 7. Opposite hand
Air Volume Flow Rate (l/s)

Electrical & Sound


Maximum dBA
Frequency/Hz 63 125 250 500 1K 2K 4K 8K
power consumption @3m
Curve (Watts) Sound Power Levels dB re 1pW
1 341 Open inlet 58 56 57 63 57 51 46 45
Open Outlet 67 63 65 75 68 63 56 53
Breakout 61 61 60 63 53 48 40 35 44
2 173 Open inlet 56 54 54 59 52 46 41 40
Open Outlet 65 61 62 71 63 58 51 48
Breakout 59 59 57 59 48 43 35 30 37
3 73 Open inlet 55 52 51 55 45 39 34 33
Open Outlet 64 59 59 67 56 51 44 41
Breakout 58 57 54 55 41 36 28 23 32
4 21 Open inlet 53 49 47 49 37 31 26 25
Open Outlet 62 56 55 61 48 48 36 33
Breakout 56 54 50 49 33 28 20 <16 27
The maximum power consumption shown above (Watts) is consumed on units running continuously, not taking into account any heat recovery saving and based on SAP Appendix
Q testing. The breakout case-radiated dBA values are given for Hemispherical free field radiation at 3m - to obtain the Spherical radiated data, subtract 3 dBA.

55
NUAIRES MVHR

SAP 2012 Test Results


Product Code MRXBOX95AB-WH2-OH
SAP Identifier MRXBOX95AB-WH2
Application Specific Fan Power Heat Exchange Energy Saving Trust Best
(W/l/s) Efficiency Practice Compliant

Kitchen + 1 Wet Room 0.60 89% Yes


Kitchen + 2 Wet Room 0.61 88% Yes
Kitchen + 3 Wet Room 0.68 88% Yes
Kitchen + 4 Wet Room 0.79 87% Yes
Kitchen + 5 Wet Room 0.95 86% Yes
Kitchen + 6 Wet Room 1.15 85% Yes
Kitchen + 7 Wet Room 1.38 85% Yes

General Arrangement
SPIGOT LOCATION &
DUCTING REFERENCES

Spigot 1. 200mm dia. = Intake air from outside.


Spigot 2. 200mm dia. = Supply air to property.
Spigot 3. 200mm dia. = Extract air from dwelling.
Spigot 4. 200mm dia. = Exhaust air to outside. Mounting Bracket on
wall and rear of unit

3 1

Two removable
G3 Filters

56
Technical - MRXBOX95AB-WH2-OH
DIMENSIONS (mm)
Weight - 44Kg

View from top


485

= = Ecosmart connection grommets


4 x Spigots
180mm Internal Diameter
139

200mm External Diameter


290

Dimensions: Unit wall mounting bracket position


(Viewed from back)
Front view Side view
Mounting
= =

200
176
710

5 Fixing Bracket to
Points be fitted to
534

the wall

710 585 40.0 CRS 40.0 CRS


492 CRS
67 67

Electrical Details - MRXBOX95AB-WH2-OH


Please note: the electrical connection of the unit must be carried out
by a qualified electrician. Detail of unit control on front panel.

The unit is supplied with a flexible cord for connection to the mains supply.
NOTE: In the event of 1kV transients the fans may stop running,
normal operation will be resumed when the interference has ceased.
The mains power supply cable should be connected to a fixed
wiring installation, via a fused isolator, in accordance with current
IEE wiring regulations.
For commissioning:
Ventilation Controls refer to user manual

Post commissioning remove


adhesive backing under
this section
+ - + - + - + - + - + -
ELECTRICAL DETAILS: MRXBOX95AB-WH2-OH
Voltage: 230V 1ph 50Hz Power

Consumption: 2.5 Amp 060905

Fuse rating: 5 Amp Tamper proof label following commissioning, includes system status indication.

57
NUAIRES MVHR

Wiring
Note: Wiring is for reference purposes only as the connections are factory fitted. The unit is pre-wired with a 2 metre fly lead.

N
UNIT SERVING
L KITCHEN & BATHROOM
N Green/Yellow
MAINS L Blue
230V N
50Hz L Brown

Fuse 5A 2 Pole Black


Isolator 1
L
Grey
2

3 Position Switch Supply cord


Ancillary code: from unit
MRXBOX95-3SWITCH

UNIT SERVING
N ONE BATHROOM
Green/Yellow
MAINS L
Blue
230V N
50Hz Brown
L
N Fuse 5A Room Black
L light
3 Pole L
1
Light Grey
Isolator 2
switch
(Double
Pole) 3 Position Switch Supply cord
Ancillary code: from unit
MRXBOX95-3SWITCH

UNIT SERVING TWO BATHROOMS


MAINS
230V N
50Hz
L
NFuse 5A Room
lights
1
L Light 3 Pole L
N switch Isolator 2
L (Double
Pole)
3 Position Switch Supply cord
Ancillary code: from unit
MRXBOX95-3SWITCH

OPTIONAL SENSORS AND DETECTORS


Customise MRXBOX95AB-WH2-OH for enhanced
performance. All supplied with pre-plugged 10m data
cable and incorporates status LED.
MRXBOX-VSC
MRXBOX95-PIR (Passive Infrared) Coming soon
A low voltage sensor, detects movement with this unit!
and activates system. Incorporates overrun
timer and timer adjustments.

MRXBOX95-HUM (Relative Humidity)


A low voltage sensor, activates the system
when the RH level is above set point. Incorporates
overrun timer and RH setpoint level adjustment.

MRXBOX95-RFI (Remote Fail Indicator)


If fan failure occurs the audio visual indicator
will flash a warning.
58
Consultants Specification
MRXBOX95AB-WH2-OH - SPECIFICATION INTEGRAL HUMIDITY SENSOR
The unit shall be fully insulated providing excellent thermal and The integral humidity sensor incorporated within the extract fan
acoustic characteristics and shall be complete with a multi plate chamber will automatically boost both the extract and supply fan, to
counter flow high efficiency heat exchanger block, with a thermal the commissioned boost speed, when the humidity level exceeds that
efficiency of up to 95%. The heat exchanger shall be protected by G3 set by the side panel mounted adjustment potentiometer.
grade filters on fresh air inlet and system extract.
OPTIONAL REMOTE SWITCH
The heat exchanger and filters shall be accessible via the front access (MRXBOX95-3 SWITCH)
panel, enabling quick and easy maintenance.
The unit shall have the facility to wire a three position remote switch to
The unit shall have low energy, high efficiency EC fan/motor a suitable location within the property. The switch shall have 3 settings,
assemblies with sealed for life bearings, the impellers shall be trickle, boost and summertime boost facility. The remote switch will
backward curved centrifugal type. act as the master switch and will override all other switches.
The motors shall be suitable of an ambient temperature of 40C. CONTROL OPTIONS
The unit shall be supplied complete with a condensate drip tray and All versions shall have the following functions integrally mounted
32mm drain connection. within the fan unit on a purpose made PCB, all such components
pre-wired and factory fitted by the manufacturer:
The unit shall be suitable for 200mm diameter circular ducting.
Independent control of background supply and extract flow rates.
Note: The unit is also available in standard format, refer to spigot
Independent control of boost speed supply and extract flow rates.
configuration for set up.
Integral fan failure indication.
The breakout noise level and power requirements shall be as detailed Integral S/L terminal for boost to commissioned level, from remote
by the unit manufacturer and in accordance with the ventilation switch, e.g. light switch.
equipment schedule. Integral S/L terminal for summertime boost speed, from remote
switch e.g. plate switch.
The unit shall be MRXBOX95AB-WH2-OH as manufactured by
Integral heat exchanger frost protection.
Nuaire and shall be listed on the SAP Product Characteristics
Discreet daily run monitor.
Database as MRXBOX95AB-WH2.
Remote fail indicator (Part number-MRXBOX95-RFI).
OPERATION Indication and controls - The unit shall have clear LED visual
The supply and extract ventilation unit shall be positioned as indication for maintenance, servicing and operation mode i.e.
indicated on the drawings and shall be in accordance with the summer bypass, frost protection.
particular fan schedule in the specification. The unit shall be offered with a 5 year warranty.
The combined supply and extract with heat recovery unit shall supply The manufacturers recommendations should be observed at all
filtered fresh air to each of the habitable rooms and moisture-laden times. The unit shall be the MRXBOX95AB-WH2-OH and shall be
air shall be extracted from the wet areas e.g. bathroom, en-suite, w.c, manufactured by Nuaire.
kitchen, utility rooms, etc. The supply air shall be pre-heated by the warm
extract air via the integrated counter-flow heat exchanger element.
The extracted air shall also be filtered before it reaches the heat
exchanger block. The ventilation unit shall vary its speed and therefore
the ventilation rate, as it receives signals from one of the following:
Switched live signal from light/remote switches.
When signals are received, the fan shall alter its speed to adjustable,
normal and boost rates.
The unit shall have the facility to commission the supply and extract
fans independently on minimum speed (continuous background
ventilation), boost speed, via inbuilt minimum and maximum speed
adjustment. The fans shall have infinitely variable speed control.

INTEGRAL AUTOMATIC SUMMER BYPASS


The bypass damper shall open automatically via a wax actuator
allowing the air to bypass the heat exchanger to deliver fresh filtered
air during the warmer months.

59
NUAIRES MVHR

MRXBOX95B-LP1 (with automatic summer bypass)


MRXBOX95B-LP1 is specifically designed for
apartment applications where space is a premium.

The MVHR unit provides optimised balanced (supply & extract)


mechanical ventilation with heat recovery. Tempered air is
delivered into living areas whilst extracting moisture-laden air
from wet areas, creating comfortable well-ventilated homes.
The unit has a facility to commission the supply & extract fans
independently on both minimum and maximum speeds. The two
independent fans have full speed control for background and boost
ventilation rates, as well as a run-on timer facility. This unit is listed
on the SAP Product Characteristics Database.

Typical Installation
INSTALLATION FEATURES

Air valve 204 x 60mm Side view of unit


in ceiling Ducting in mounted in the
Filter plate and filter Control module
ceiling void ceiling void Access to second filter
being removed

60
Performance - MRXBOX95B-LP1
CODE DESCRIPTION
600

500
MRXBOX95B-LP1
400
1 2 3 4 5
Fan Static Pressure (Pa)

300 1. Multi-room supply and extract


1 heat recovery
200
2
2. Product range
100
3 3. Efficiency
4 4. Automatic Bypass
0
0 20 40 60 80 5. Low profile
Air Volume Flow Rate (l/s)

Electrical & Sound


Maximum Frequency/Hz 63 125 250 500 1K 2K 4K 8K dBA
power consumption @3m
Curve (Watts) Sound Power Levels dB re 1pW
1 147 Open inlet 50 56 55 55 46 42 32 23
Open Outlet 57 66 67 68 66 65 55 48
Breakout 65 64 63 62 52 47 38 30 52
2 75 Open inlet 49 51 54 49 41 37 25 <16
Open Outlet 55 61 63 63 61 57 48 39
Breakout 61 61 60 56 47 41 30 17 35
3 32 Open inlet 43 46 45 41 33 27 18 <16
Open Outlet 51 55 55 56 53 51 38 29
Breakout 55 55 52 47 38 30 21 <16 27
4 9 Open inlet 38 40 34 32 23 17 <16 <16
Open Outlet 45 48 45 46 43 41 26 <16
Breakout 48 47 41 36 26 <16 <16 <16 16
The maximum power consumption shown above (Watts) is consumed on units running continuously, not taking into account any heat recovery saving based on SAP Appendix Q
testing. The breakout case-radiated dBA values are given for Hemispherical free field radiation at 3m - to obtain the Spherical radiated data, subtract 3 dBA.

61
NUAIRES MVHR

SAP 2012 Test Results


Product Code MRXBOX95B-LP1
Exhaust terminal Specific Fan Power Heat Exchange
Configuration (W/l/s) Efficiency
Kitchen + 1 Wet Room 0.59 76%
Kitchen + 2 Wet Room 0.71 76%
Kitchen + 3 Wet Room 0.91 78%
Kitchen + 4 Wet Room 1.15 79%
Kitchen + 5 Wet Room 1.40 79%

General Arrangement
MRXBOX95B-LP1-OH

Control module

Filter Code
MVHR-LP1-FILTERKIT 4 x Spigots for 204 x 60mm
rectangular ducting

Filter and filter plate


being removed

Second filter and filter plate


being removed

62
Technical - MRXBOX95B-LP1
DIMENSIONS
MRXBOX95B-LP1 (mm) (mm)
- DIMENSIONS

Weight - 37kg
View from underside with lid removed (B)
900
700

21.5mm Condensate drain

View from control side (A) End view 371

67
200

200

153

(B)

Electrical Details
Please note: the electrical connection of the unit must be carried out
by a qualified electrician. Detail of unit control on control panel.
Control
The unit is supplied with a flexible cord for connection to the module
mains supply.
NOTE: This unit must be earthed.
The three core cable from the mains power supply should be
connected to a fixed wiring installation, via a fused isolator, in
accordance with current IEE wiring regulations.

ELECTRICAL DETAILS: MRXBOX95B - LP1


Voltage: 230V 1ph 50Hz
Consumption: LP1 - 1.3 Amp
Tamper proof label following commissioning, includes system status indication.
Fuse rating: 1.3 Amp

63
NUAIRES MVHR

Wiring MRXBOX95B-LP1
DIMENSIONS (MM) & WEIGHT UNIT
UNIT SERVING KITCHEN & BATHROOM

Supply cord
N Green/Yellow from unit
L
MAINS
Blue
230V N
50Hz L Brown

Fuse 2A Room Black


light
3 Pole Grey
Light isolator
switch
(Double Pole) Optional summer boost switch

Kitchen switch

UNIT SERVING KITCHEN & TWO BATHROOMS


Supply cord
Green/Yellow from unit
MAINS
230V N Blue
50Hz L Brown
N Black
Fuse
L 2A Room
lights 3 Pole Grey
Light
switches isolator
(Double Pole) Optional summer boost switch

Kitchen switch

OPTIONAL SENSORS AND DETECTORS


Customise MRXBOX95B-LP1 for enhanced performance.
All supplied with pre-plugged 10m data cable and
incorporates status LED. MRXBOX-VSC
MRXBOX95-PIR (Passive Infrared) CONTROL SCREEN
A low voltage sensor, detects movement COMPATIBLE WITH
and activates system. Incorporates overrun THIS UNIT
timer and timer adjustments.

MRXBOX95-HUM (Relative Humidity)


A low voltage sensor, activates the system
when the RH level is above set point. Incorporates
overrun timer and RH setpoint level adjustment.

MRXBOX95-RFI (Remote Fail Indicator)


If fan failure occurs the audio visual indicator
will flash a warning.

64
NUAIRES MVHR

Consultants Specification
SPECIFICATION INTEGRAL AUTOMATIC SUMMER BYPASS
The unit shall be manufactured from galvanised sheet steel with a white, (MRXBOX95B-LP1)
pre-painted removable access panel. The unit shall be fully insulated The bypass damper shall open automatically via a wax actuator,
providing excellent thermal and acoustic characteristics and shall be allowing the air to bypass the heat exchanger to deliver fresh filtered
complete with a multi plate, aluminium, counter flow high efficiency air during the warmer months.
heat exchanger block, with a thermal efficiency of up to 80%. The heat
exchanger shall be protected by G3 grade filters on fresh air inlet and CONTROL OPTIONS
system extract. The heat exchanger and filters shall be accessible via the All versions shall have the following functions integrally mounted
underside access panels, enabling quick and easy maintenance. within the fan unit on a purpose made PCB, all such components
The unit shall have a maximum depth of 200mm to fit within ceiling pre-wired and factory fitted by the manufacturer:
void restrictions. The unit shall have low energy, high efficiency EC Independent control of background supply and extract flow rates.
fan/motor assemblies with sealed for life bearings, the impellers shall Independent control of boost speed supply and extract flow rates.
be backward curved centrifugal type. Integral heat exchanger frost protection.
The motors shall be suitable of an ambient temperature of 40C. Fan failure indication.
Integral S/L terminal for boost from remote switch, e.g. light switch.
Motor assemblies shall be removable from the underside of the unit Additional S/L terminal for 100% boost speed from remote switch,
and will not require the unit to be removed from situ. e.g. plate switch.
The unit shall be supplied complete with a condensate drip tray and Discreet daily run monitor.
21.5mm drain connection. Remote fail indicator (part number MRXBOX95-RFI).
Indication and controls The unit shall have clear LED visual
The unit shall be suitable for 204x60mm rectangular ducting. indication for maintenance, servicing and operation mode,
Note: The unit is also available in opposite handed format, refer to i.e. summer bypass, frost protection.
spigot configuration for set up.
MRXBOX-VSC (VISUAL SYSTEM CONTROLLER)
The breakout noise level and power requirements shall be as detailed
The MRXBOX-VSC is compatible with the Nuaire MRXBOX95(AB)-WH1
by the unit manufacturer and in accordance with the ventilation
heat recovery units and can be purchased separately. The controller
equipment schedule.
comes complete with commissioning and end user functions.
Units shall be MRXBOX95B-LP1 as manufactured by Nuaire and shall
The display will be a 3.5 LCD display and will remain on standby until
be listed on the Sap Appendix Q database.
such time the screen is touched.
OPERATION The initial display will show the MVHR system status as listed below:
The supply and extract ventilation unit shall be positioned as
Current Fan Speed.
indicated on the drawings and shall be in accordance with the
Current indoor/outside temperature.
particular fan schedule in the specification.
Indicate when the summer bypass is activated.
The combined supply and extract with heat recovery unit shall supply Indicate when frost protection is activated.
filtered fresh air to each of the habitable rooms and moisture-laden Indicate when the filters require cleaning/changing.
air shall be extracted from the wet areas e.g. bathroom, en-suite, w.c,
kitchen, utility rooms, etc. The supply air shall be pre-heated by the warm
extract air via the integrated counter-flow heat exchanger element.
The extracted air shall also be filtered before it reaches the heat
exchanger block. The ventilation unit shall vary its speed and therefore
the ventilation rate, as it receives signals from one of the following:
Switched live signal from light/remote switches.
When signals are received, the fan shall alter its speed to adjustable,
normal and boost rates.
The unit shall have the facility to commission the supply and extract
fans independently on minimum speed (continuous background
ventilation), and boost speed, via inbuilt minimum and maximum
speed adjustment. The fans shall have infinitely variable speed control.

65
NUAIRES MVHR

MRXBOX95B-LP1-OH (with automatic summer bypass)


MRXBOX95B-LP1-OH is specifically designed for
apartment applications where space is a premium.

The MVHR unit provides optimised balanced (supply & extract)


mechanical ventilation with heat recovery. Tempered air is delivered
into living areas whilst extracting moisture-laden air from wet
areas, creating comfortable well-ventilated homes. The unit has a
facility to commission the supply & extract fans independently on
both minimum and maximum speeds. The two independent fans
have full speed control for background and boost ventilation rates, as
well as a run-on timer facility. This unit is listed on the SAP Product
Characteristics Database.

Typical Installation
INSTALLATION FEATURES

Air valve 204 x 60mm Side view of unit


in ceiling Ducting in mounted in the
ceiling void ceiling void Access to second filter Filter plate and filter Control module
being removed

66
Performance - MRXBOX95B-LP1-OH
CODE DESCRIPTION
600

500
MRXBOX95B-LP1-OH
400
1 2 3 4 5 6
Fan Static Pressure (Pa)

300 1. Multi-room supply and extract


1 heat recovery
200
2
2. Product range
100
3 3. Efficiency
4 4. Automatic Bypass
0
0 20 40 60 80 5. Low profile
Air Volume Flow Rate (l/s) 6. Opposite hand

Electrical & Sound


Maximum Frequency/Hz 63 125 250 500 1K 2K 4K 8K dBA
power consumption @3m
Curve (Watts) Sound Power Levels dB re 1pW
1 147 Open inlet 50 56 55 55 46 42 32 23
Open Outlet 57 66 67 68 66 65 55 48
Breakout 65 64 63 62 52 47 38 30 52
2 75 Open inlet 49 51 54 49 41 37 25 <16
Open Outlet 55 61 63 63 61 57 48 39
Breakout 61 61 60 56 47 41 30 17 35
3 32 Open inlet 43 46 45 41 33 27 18 <16
Open Outlet 51 55 55 56 53 51 38 29
Breakout 55 55 52 47 38 30 21 <16 27
4 9 Open inlet 38 40 34 32 23 17 <16 <16
Open Outlet 45 48 45 46 43 41 26 <16
Breakout 48 47 41 36 26 <16 <16 <16 16
The maximum power consumption shown above (Watts) is consumed on units running continuously, not taking into account any heat recovery saving based on SAP Appendix Q
testing. The breakout case-radiated dBA values are given for Hemispherical free field radiation at 3m - to obtain the Spherical radiated data, subtract 3 dBA.

67
NUAIRES MVHR

SAP 2012 Test Results


Product Code MRXBOX95B-LP1-OH
SAP Identifier MRXBOX95B-LP1
Exhaust terminal Specific Fan Power Heat Exchange
Configuration (W/l/s) Efficiency
Kitchen + 1 Wet Room 0.59 76%
Kitchen + 2 Wet Room 0.71 76%
Kitchen + 3 Wet Room 0.91 78%
Kitchen + 4 Wet Room 1.15 79%
Kitchen + 5 Wet Room 1.40 79%

General Arrangement
MRXBOX95B-LP1-OH

Control module

Filter Code
MVHR-LP1-FILTERKIT 4 x Spigots for 204 x 60mm
rectangular ducting

Filter and filter plate


being removed

Second filter and filter plate


being removed

68
Technical - MRXBOX95B-LP1-OH
DIMENSIONS
MRXBOX95B-LP1 (mm) (mm)
- DIMENSIONS

Weight - 37kg
View from underside with lid removed (B)
900
700

21.5mm Condensate drain

View from control side (A) End view 371

67
200

200

153

(B)

Electrical Details
Please note: the electrical connection of the unit must be carried out
Detail of unit control on control panel.
by a qualified electrician.
Control
The unit is supplied with a flexible cord for connection to the module
mains supply.
NOTE: This unit must be earthed.
The three core cable from the mains power supply should be
connected to a fixed wiring installation, via a fused isolator, in
accordance with current IEE wiring regulations.

ELECTRICAL DETAILS: MRXBOX95B - LP1-OH


Voltage: 230V 1ph 50Hz
Consumption: LP1 - 2.5 Amp
Tamper proof label following commissioning, includes system status indication.
Fuse rating: 1.3 Amp

69
NUAIRES MVHR

Wiring MRXBOX95B-LP1-OH
DIMENSIONS (MM) & WEIGHT UNIT
UNIT SERVING KITCHEN & BATHROOM

Supply cord
N Green/Yellow from unit
L
MAINS
Blue
230V N
50Hz L Brown

Fuse 2A Room Black


light
3 Pole Grey
Light isolator
switch
(Double Pole) Optional summer boost switch

Kitchen switch

UNIT SERVING KITCHEN & TWO BATHROOMS


Supply cord
Green/Yellow from unit
MAINS
230V N Blue
50Hz L Brown
N Black
Fuse
L 2A Room
lights 3 Pole Grey
Light
switches isolator
(Double Pole) Optional summer boost switch

Kitchen switch

OPTIONAL SENSORS AND DETECTORS


Customise MRBOX95B-LP1-OH for enhanced
performance. All supplied with pre-plugged 10m data
cable and incorporates status LED. MRXBOX-VSC
MRXBOX95-PIR (Passive Infrared) CONTROL SCREEN
A low voltage sensor, detects movement COMPATIBLE WITH
and activates system. Incorporates overrun THIS UNIT
timer and timer adjustments.

MRXBOX95-HUM (Relative Humidity)


A low voltage sensor, activates the system
when the RH level is above set point. Incorporates
overrun timer and RH setpoint level adjustment.

MRXBOX95-RFI (Remote Fail Indicator)


If fan failure occurs the audio visual indicator
will flash a warning.

70
Consultants Specification
SPECIFICATION INTEGRAL AUTOMATIC SUMMER BYPASS
The unit shall be manufactured from galvanised sheet steel with a white, (MRXBOX95B-LP1-OH)
pre-painted removable access panel. The unit shall be fully insulated The bypass damper shall open automatically via a wax actuator,
providing excellent thermal and acoustic characteristics and shall be allowing the air to bypass the heat exchanger to deliver fresh filtered
complete with a multi plate, aluminium, counter flow high efficiency air during the warmer months.
heat exchanger block, with a thermal efficiency of up to 80%. The heat
exchanger shall be protected by G3 grade filters on fresh air inlet and CONTROL OPTIONS
system extract. The heat exchanger and filters shall be accessible via the All versions shall have the following functions integrally mounted
underside access panels, enabling quick and easy maintenance. within the fan unit on a purpose made PCB, all such components
The unit shall have a maximum depth of 200mm to fit within ceiling pre-wired and factory fitted by the manufacturer:
void restrictions. The unit shall have low energy, high efficiency EC Independent control of background supply and extract flow rates.
fan/motor assemblies with sealed for life bearings, the impellers shall Independent control of boost speed supply and extract flow rates.
be backward curved centrifugal type. Integral heat exchanger frost protection.
The motors shall be suitable of an ambient temperature of 40C. Fan failure indication.
Integral S/L terminal for boost from remote switch, e.g. light switch.
Motor assemblies shall be removable from the underside of the unit Additional S/L terminal for 100% boost speed from remote switch,
and will not require the unit to be removed from situ. e.g. plate switch.
The unit shall be supplied complete with a condensate drip tray and Discreet daily run monitor.
21.5mm drain connection. Remote fail indicator (part number MRXBOX95-RFI).
Indication and controls The unit shall have clear LED visual
The unit shall be suitable for 204x60mm rectangular ducting. indication for maintenance, servicing and operation mode,
i.e. summer bypass, frost protection.
Note: The unit is also available in standard format, refer to spigot
configuration for set up.
MRXBOX-VSC (VISUAL SYSTEM CONTROLLER)
The breakout noise level and power requirements shall be as detailed The MRXBOX-VSC is compatible with the Nuaire MRXBOX95(AB)-WH1
by the unit manufacturer and in accordance with the ventilation heat recovery units and can be purchased separately. The controller
equipment schedule. comes complete with commissioning and end user functions.
Units shall be MRXBOX95B-LP1-OH as manufactured by Nuaire and The display will be a 3.5 LCD display and will remain on standby until
shall be listed on the Sap Appendix Q database. such time the screen is touched.

OPERATION The initial display will show the MVHR system status as listed below:
The supply and extract ventilation unit shall be positioned as Current Fan Speed.
indicated on the drawings and shall be in accordance with the Current indoor/outside temperature.
particular fan schedule in the specification. Indicate when the summer bypass is activated.
Indicate when frost protection is activated.
The combined supply and extract with heat recovery unit shall supply
Indicate when the filters require cleaning/changing.
filtered fresh air to each of the habitable rooms and moisture-laden
air shall be extracted from the wet areas e.g. bathroom, en-suite, w.c,
kitchen, utility rooms, etc. The supply air shall be pre-heated by the warm
extract air via the integrated counter-flow heat exchanger element.
The extracted air shall also be filtered before it reaches the heat
exchanger block. The ventilation unit shall vary its speed and therefore
the ventilation rate, as it receives signals from one of the following:
Switched live signal from light/remote switches.
When signals are received, the fan shall alter its speed to adjustable,
normal and boost rates.
The unit shall have the facility to commission the supply and extract fans
independently on minimum speed (continuous background ventilation),
and boost speed, via inbuilt minimum and maximum speed adjustment.
The fans shall have infinitely variable speed control.

71
NUAIRES MVHR

Airepod
AP-MVHR-LL & AP-MVHR-RL
The Airepod system is a 90% efficient whole house/
apartment heat recovery unit which uniquely also
provides a minimum of 70% of the property's
heating, removing the need for a wet heating NEW
system. It replaces the typical inflexible wet heating
system and removes the need for radiators. Airepod
is a low-profile ceiling mounted system, just Airepod uses a traditional heat exchanger but differs from conventional
235.0mm in depth, saving valuable storage space. heat recovery systems in that it includes a third blower which allows
additional, pre-tempered room air to be recirculated and mixed
The 70% base heating load is delivered by an LTHW heating coil with incoming fresh air through the heater battery. Control of the
within the Airepod fed from either central CHP or energy centre. recirculating fan is independent of the supply/extract fans. The approved
The remaining 30% of heat is provided by electric heaters within document F ventilation rates are maintained at all times with the
the duct system, or fan-coils in higher specification apartments. recirculating blower only topping up air-flow when heating is needed.
Both units are listed on the SAP Product Characteristics Database.

AIREPOD How does it work?

Performance SAP 2012 Test Results


Airepod AP-MVHR-LL / AP-MVHR-RL

Application Specific Fan Power Heat Exchange Efficiency


600
(W/l/s)
500
Kitchen + 1 Wet Room 0.67 86%
400 Kitchen + 2 Wet Rooms 0.66 86%
Fan Static Pressure (Pa)

300
Kitchen + 3 Wet Rooms 0.7 86%
Kitchen + 4 Wet Rooms 0.8 86%
200
Kitchen + 5 Wet Rooms 0.89 85%
100 Kitchen + 6 Wet Rooms 1.07 85%
0

0 10.0 20.0 30.0 40.0 50.0 60.0 70.0 80.0 90.0 Call for further information
Air Volume Flow Rate (l/s)

Tel: 029 2085 8500


Email: residential.enquiries@nuaire.co.uk
72
General Arrangement
DIMENSIONS (mm)
Weight - 40Kg 1279.0 DRAWING NOT TO
1152.0
E
AL
47.5 47.5 Re-Circulation Damper RI

MAIN UNIT
253.0

222.0
O
Control Box fitted
with 1000mm
umbilical cable
21.5 Condensate Drain 87.8 745.0
Extract
Filter Access

Discharge Extract
652.0
707.3

232.0
Fresh Air

Supply 64.4
142.8 657.6

Coil Tails
Filter Access
40.0
153.2

Nuaire Limit
Western Industrial Estate
Caerphilly CF83 1NA
United Kingdom
www.nuaire.co.uk

CONTROL BOX 372.8


132.7

204.4
6
6.
No

355.8
4

83.6

4
73
NUAIRES MVHR

Consultants Specification
OPERATION HEAT RECOVERY BYPASS OPERATION
The Nuaire AP-MVHR-LL/RL unit fulfils two separate, but related The Nuaire AP-MVHR-LL/RL unit incorporates a high efficiency
functions and is available as either Left-hand Low-pressure (LL), or counter-flow heat recovery device, with a 100% bypass facility.
Right-hand Low-pressure (RL). It should be understood that the heat recovery bypass operation
serves only to prevent unwanted heat gain in the supply air stream
The unit provides continuous ventilation for the apartment supply
from the extract air stream. It is a passive control measure the
ventilation (fresh, outside air ducted to the habitable rooms), and extract
resultant supply air temperature in bypass mode being simply that
ventilation (moisture-laden air extracted from the wet rooms, and
of the outside air temperature. In heat recovery mode, the supply air
discharged from the building). The unit incorporates a high efficiency
temperature will fall between that of the outside air and that of the
heat recovery section that transfers heat from the extract air, and uses
room return air, and largely biased towards the higher of the two
it to warm the supply air. This arrangement reduces the ventilation
regardless of which this is.
heating load.
The bypass damper is not capable of modulation. Control of the
The heat recovery section includes a bypass arrangement that may be
bypass damper shall be by others (switched mains signal).
used to prevent heat transfer occurring in operational periods when
heating is not required. FREE COOLING
The additional function is to provide a percentage of the overall Because of the relatively low airflow rates delivered by a residential
heating requirement for the apartment. ventilation system, the potential for free cooling by means of the
bypass is extremely limited.
This heating is provided by a LTHW coil that is mounted within the
MVHR unit. HEATING
The outside air supply and vitiated air extract rates are to be Control of the LTHW heating coil output shall be by others.
determined (for each apartment) by the methods described in Operation of the unit heating coil, shall necessitate the supply
Approved Document F (Ventilation). system operation at the boost rate, and where appropriate, the
operation of the re-circulation fan / damper.
Typically, for ventilation only, there are a number of operating conditions :
Whole Dwelling Supply Rate (WDSR) based on the number of CONDENSATE
bedrooms or 0.3 l/s per m2 of floor area. In the course of normal operation, it is to be expected that
condensate will be produced as a result of the cooling of the
High extract rate (HER), based on pre-set values for type and quantity
extract air-stream. Condensate is discharged from the unit via a
of wet rooms.
plain un-trapped connection.
Low extract rate (LER), equal to the Whole Dwelling Supply Rate.
UNIT FAIL SIGNAL
The ventilation air flow rates for each apartment therefore must be
A common fault output is available at the unit, and should be
individually determined.
verified as clear prior to operation of any heating mode.
Unit operation at the HER is typically initiated by manual switch and /
(Note the consultant engineer has recently requested
or light switch interface.
independent fan failure indication. This is under evaluation, but
For the heating function, there is a different airflow criterion to meet, does not currently form part of the product specification).
as the heating input must be delivered at maximum temperature of
50 deg C. SOCIAL HOUSING APPLICATIONS
In these properties, the additional 30% of the base heating input is
Again, the heat loss conditions are specific to, and must be
to be provided by burst fire controlled duct mounted electric heaters.
determined for, each apartment.
One heater is to be provided for each habitable room.
If the heat loads and supply temperature limit require supply flow
The control of these heaters shall be by individual room set-point
rates that are greater than the standard ventilation rates, this can be
controller. The output of these controllers is directly applied to the
economically accomplished by means of the re-circulation feature
relevant burst fired controlled heater.
within the Nuaire AP-MVHR-LL/RL unit.
These controllers shall be enabled by the central controller whenever
The maximum supply air flow rate that can be achieved in this
heating is required in the apartment, and this enable signal shall
manner will be limited principally by the ductwork resistance, and
necessitate the supply system operation at boost rate, and where
acceptable noise levels within the apartment.
appropriate, the operation of the re-circulation fan / damper.

7474
NUAIRE SUMMARY:- Screw fastened access panels shall be provided, enabling all required
Supply - at a minimum rate of WDSR, and at a maximum maintenance functions to be carried out.
rate determined by the heating requirement, and initiated by The unit shall be provided with 4 brackets and threaded mounting
a switched 230V HEATING ENABLE signal from the central points to enable fixing to the ceiling slab.
controller. Maximum rate operation may include operation of
Ductwork connection spigots (sheet metal or PVC mouldings) shall
the units re-circulation function.
be provided.
Extract at a minimum rate of LER, and at a maximum rate of
An electrical connection box, with terminal strips, shall be provided,
HER when initiated by manual switch/light switch (230V signal).
fixed to the outside of the unit casing, for connection to mains power
Bypass limits heat pick up in the supply air. Bypass operation and the third party controller. (The unit does not incorporate a means
shall be controlled by switched 230V signal from the central of electrical isolation.) N.B. Control cables should not be routed within
controller or other source. 50mm of mains supply cables.
Common fault signal Available at unit. Unit operation shall be Unit current rating:- 1.5 A Fusing requirement :- 3A Power supply 1 ph.
verified prior to operation of heating system. (NB this is essential 230V 50 Hz AC. This unit must be earthed.
for the electrical heating system for social housing).
Controls the unit shall be fitted with a local control having the
LTHW heating coil control by others. following functionality:

SOCIAL HOUSING APARTMENTS 2 stage speed / duty adjustment of the supply and extract fans, and
The system shall include duct mounted electric heaters, with burst single duty adjustment of the recirculation fan.
fired electric controllers.
Each habitable room shall be provided with an individual heating
set-point control.
Re-circ. fan
This control shall be enabled by a switched 230V HEATING
ENABLE signal from the central controller that simultaneously
boosts the supply airflow rate.

OUTLINE SPECIFICATION
It is anticipated that apartment layouts and utility cupboard Bypass control terminals (230V AC) (Bypass actuator fitted and
restrictions will result in the requirement for a number of product connected internally)
configurations. Generally these do not affect product costs.
Heating Enable terminals (230V AC) (Boosts unit flow rate and
The MVHR unit shall provide supply and extract ventilation and initiates Re-circulation fan /
part of the heating requirement for the dwellings. damper operation if required)
The unit shall incorporate high efficiency supply and extract fans of Typical wiring example - manual control of High/Low flow rate by
backward curved centrifugal design with integral EC type motors. light switch.
The unit shall incorporate a high efficiency counter- flow heat UNIT SERVING KITCHEN AND BATHROOM
recovery module c/w 100% bypass facility. Supply cord
from unit
Green/Yellow
The unit shall incorporate a LTHW heating coil (capacity specific to MAINS
Blue
230V N
Brown
property requirements). The coil connections (15mm copper x 2) shall 50Hz L
Black
Room
terminate outside the unit casing for connection to third party valve gear. Fuse light
2A 3 Pole
isolator
The unit shall incorporate a re-circulation facility, with damper, Light Summer
switch bypass
damper actuator, and high efficiency fan of backward curved (Double Pole) Kitchen switch switch Grey (only used
on bypass unit)
centrifugal design with integral EC type motor.
The unit shall incorporate an insulated drip tray for collection of
condensate generated by the heat recovery device. A condensate
drain connection shall be provided, terminating outside the unit casing
(trapping, by others, is normally required when connecting to household
drainage. Use of the Nuaire product - MVHR-DRAIN is recommended).
The unit casing shall be manufactured in galvanised mild steel
(natural finish), acoustically and thermally insulated to a level
appropriate for the application.

75
NUAIRES MVHR

Acoustic solution for


MRXBOX95(AB)-WH1 and
MRXBOX95(AB)-WM2
Nuaires First Fix and Acoustic Solution are designed to
not only reduce noise but to improve the installation
when wall or cupboard mounting the MRXBOX95(AB)-
WH1 and MRXBOX95(AB)-WM2 Units.

Offering the only complete MVHR acoustic and first fix solution to
overcome both noise and ease the installation of heat recovery units.
Nuaires solution addresses both duct and breakout noise, provides an
aesthetically pleasing cupboard installation for the home occupant and
reduces installation errors and time.
These units are also available in Opposite Handed format.

Typical Installation

FIRST FIX SOLUTION FF-WH1/FF-WM2


Nuaires First Fix box is fixed
to the underside of the floor
slab at first fix stage of the build.
The box has four airflow
chambers with optional positions
for 204x60mm spigots. Ceilings MRXBOX-FF-WH1
can then be boarded within the cupboard space easily and
quickly without the risk of the spigots not aligning to the fan unit.

SILENCER SIL-WH1/SIL-WM2
Nuaire has created a unique solution that is not only designed to
reduce noise significantly, addressing duct and breakout noise,
but is visibly appealing for the home occupant. It can be used
with or without the First Fix Solution.

MRXBOX95(AB)-WH1/ MRXBOX95(AB)- WM2


Nuaires Silencer and First Fix solution are compatible with the
MRXBOX95(AB)-WH1 and MRXBOX95(AB)-WM2 heat recovery
units, which are designed for medium to large properties.

76
Acoustic data for MRXBOX95(AB)-WH1
with Silencer and/or First Fix
dBA
WH1 with SIL Sound Data Frequency/Hz 63 125 250 500 1K 2K 4K 8K
@3m
Curve Max. Power/W Sound power levels dB re 1pW
1 Open Inlet 40 41 49 39 25 <16 <16 <16
150 Open Outlet 45 53 58 53 39 34 30 26
Breakout 56 61 59 53 43 40 25 16 37

dBA
WH1 with FF Sound Data Frequency/Hz 63 125 250 500 1K 2K 4K 8K
@3m
Curve Max. Power/W Sound power levels dB re 1pW
1 Open Inlet 44 44 53 43 40 32 19 <16
150 Open Outlet 48 58 63 60 55 53 44 35
Breakout 56 61 59 53 43 40 25 16 37

dBA
WH1 with FF & SIL Sound Data Frequency/Hz 63 125 250 500 1K 2K 4K 8K
@3m
Curve Max. Power/W Sound power levels dB re 1pW
1 Open Inlet 36 31 43 33 25 <16 <16 <16
150 Open Outlet 38 45 49 42 32 25 22 <16
Breakout 56 61 59 53 43 40 25 16 37

The breakout case-radiated dBA values are given for Hemispherical free field radiation at 3m to obtain the spherical radiated data, subtract 3dBA.

Silencer Corrections

SIL Corrections Open Inlet -8 -10 -9 -10 -22 -24 -16 -13

Open Outlet -11 -10 -9 -14 -23 -26 -20 -15

Breakout 0 0 0 0 0 0 0 0

FF Corrections Open Inlet -4 -7 -5 -6 -7 -7 -6 -4

Open Outlet -8 -5 -4 -7 -7 -7 -6 -6

Breakout 0 0 0 0 0 0 0 0

FF+SIL Corrections Open Inlet -12 -20 -15 -16 -22 -24 -19 -16

Open Outlet -18 -18 -18 -25 -30 -35 -28 -26

Breakout 0 0 0 0 0 0 0 0

77
NUAIRES MVHR

Technical
DIMENSIONS (mm) for WH1 unit
SIL-WH1 655 445
TOP VIEW 458 CRS SIDE VIEW

= =

150
=
227 CRS
432

FF-WH1 FRONT/REAR VIEW 400


= =
=
=

204 x 60

666
TOP VIEW SIDE VIEW
458 CRS FACE TO BE MOUNTED 110
NEAREST TO WALL = =
= =
107

150
227 CRS

=
242 CRS
489

=
155

COMPLETED SYSTEM 30
TOP VIEW SIDE VIEW
167
462

1132
1110

965
648

CROSS BRACE
66

= =
ADJUSTABLE FEET
WALL/SOLID STRUCTURE
672
ANGLE BRACKET
78
Consultants Specification
SIL-WH1 OPERATION
The unit offers the facility to be fitted directly to the MVHR unit and The supply and extract ventilation unit shall be positioned as indicated
plenum chamber without the need for spigots reducing breakout noise. on the drawings and shall be in accordance with the particular fan
However, there is the capability to fit 150mm circular spigots as an schedule in the specification. This unit is also available in Opposite
alternative option. Hand formatting.
The unit shall be fully lined with acoustic material offering excellent The combined supply and extract with heat recovery unit, shall supply
noise reduction. filtered fresh air to each of the habitable rooms and vitiated air shall be
extracted from the wet areas e.g. bathroom, en-suite, w.c, kitchen, utility
Wall mounting brackets are to be supplied as part of the system to allow
rooms, etc. The supply air shall be pre-heated by the warm extract air via
the MVHR unit to be raised after other system components are installed
the integrated counter-flow heat exchanger element. The extracted air
to form an airtight seal and enable the installation to be levelled.
shall also be filtered before it reaches the heat exchanger block.
The unit shall be clamped to the MRXBOX95(AB)-WH1 unit to provide
The ventilation unit shall vary its speed and therefore the ventilation
an efficient seal and ensure correct alignment.
rate, as it receives signals from the switched live signal from light/
The unit shall be fixed in position during installation as a standalone remote switches or any ancillary sensors. When signals are received, the
section without relying on other system elements. fan shall alter its speed to adjustable, normal and boost rates.
The unit shall have the facility to commission the supply and extract
FF- WH1
fans independently on minimum speed (continuous background
The unit shall be supplied with 204mm x 60mm rectangular spigots to
ventilation), and boost speed, via inbuilt minimum and maximum
connect to the duct run, with the ability to be fitted in eight separate
speed adjustment. The fans shall have infinitely variable speed control.
positions reducing the requirement for bends in the system.
The unit offers the facility to be fitted directly to the mating sections
INTEGRAL AUTOMATIC SUMMER BYPASS
without the need for spigots reducing breakout noise, additional
(MRXBOX95AB-WH1 & MRXBOX95AB-WH1-OH only)
150mm circular spigots to be supplied as an alternative option. Including Automatic SUMMER BYPASS where intake and return air
temperatures shall be measured so that supply air temperatures can be
TECHNICAL DATA maximised during winter months and minimised as external ambient
Units shall be one of MRXBOX95AB-WH1, MRXBOX95-WH1, temperature rises. The Summer Bypass damper shall be opened by a
MRXBOX95AB-WH1-OH, MRXBOX95-WH1-OH as manufactured wax actuator. Supply and Extract air shall be filtered irrespective of the
by Nuaire. bypass setting (open or closed).

SPECIFICATION CONTROL OPTIONS


The unit shall be fully insulated providing excellent thermal and All versions shall have the following functions integrally mounted
acoustic characteristics and shall be complete with a multi plate within the fan unit on a purpose made PCB, all such components
counter flow high efficiency heat exchanger block, with a thermal pre- wired and factory fitted by the manufacturer:
efficiency of up to 95%. The heat exchanger shall be protected by G3
Independent control of background supply and extract flow rates.
grade filters on fresh air inlet and system extract. The heat exchanger
Independent control of boost speed supply and extract flow rates.
and filters shall be accessible via the front access panel, enabling quick
Integral fan failure indication.
and easy maintenance.
Integral S/L terminal for boost from remote switch, e.g. light switch,
The unit shall have low energy, high efficiency EC fan/motor kitchen boost switch.
assemblies with sealed for life bearings, the impellers shall be backward Integral heat exchanger frost protection.
curved centrifugal type. The motors shall be suitable of an ambient Discreet daily run monitor.
temperature of 40C. Integral humidistat.

The unit shall be supplied complete with a condensate drip tray and OPTIONAL CONTROLS
21.5mm drain connection.
MRXBOX95-RFI Remote fail indicator.
The unit shall be suitable for 150mm diameter circular ducting.
MRXBOX95-PIR (Passive Infra-Red) A low voltage sensor which detects
The breakout noise level and power requirements shall be as detailed movement and activates system.
by the unit manufacturer and in accordance with the ventilation
MRXBOX95-HUM A low voltage sensor which activates the system
equipment schedule.
when the relative humidity level is above a set point.
The unit shall be offered with a 5 year warranty.
MRXBOX-VSC An LCD controller for MVHR system with a 3.5 touch
screen display.

79
NUAIRES MVHR

Acoustic data for MRXBOX95(AB)-WM2


with Silencer and/or First Fix
dBA
WM2 with SIL Sound Data Frequency/Hz 63 125 250 500 1K 2K 4K 8K
@3m
Curve Max. Power/W Sound power levels dB re 1pW
1 Open Inlet 49 47 52 46 28 23 20 21
150 Open Outlet 44 55 62 53 41 34 31 28
Breakout 61 61 56 53 47 44 35 33 37

dBA
WM2 with FF Sound Data Frequency/Hz 63 125 250 500 1K 2K 4K 8K
@3m
Curve Max. Power/W Sound power levels dB re 1pW
1 Open Inlet 53 50 56 50 43 40 30 30
150 Open Outlet 47 60 67 60 57 53 45 37
Breakout 61 61 56 53 47 44 35 33 37

dBA
WM2 with FF & SIL Sound Data Frequency/Hz 63 125 250 500 1K 2K 4K 8K
@3m
Curve Max. Power/W Sound power levels dB re 1pW
1 Open Inlet 45 37 46 40 28 <16 <16 <16
150 Open Outlet 37 47 53 42 34 25 23 17
Breakout 61 61 53 47 44 35 33 37

The breakout case-radiated dBA values are given for Hemispherical free field radiation at 3m to obtain the spherical radiated data, subtract 3dBA.

Silencer Corrections

SIL Corrections Open Inlet -8 -10 -9 -10 -22 -24 -16 -13

Open Outlet -11 -10 -9 -14 -23 -26 -20 -15

Breakout 0 0 0 0 0 0 0 0

FF Corrections Open Inlet -4 -7 -5 -6 -7 -7 -6 -4

Open Outlet -8 -5 -4 -7 -7 -7 -6 -6

Breakout 0 0 0 0 0 0 0 0

FF+SIL Corrections Open Inlet -12 -20 -15 -16 -22 -24 -19 -16

Open Outlet -18 -18 -18 -25 -30 -35 -28 -26

Breakout 0 0 0 0 0 0 0 0

80
Technical
DIMENSIONS (mm) for WM2 unit
SIL-WM2 605
TOP VIEW 445 SIDE VIEW
417 CRS

= =

125
=
172 CRS
353

FF-WM2 400
FRONT/REAR VIEW
= =
=
=

204 x 60
670 110
TOP VIEW
SIDE VIEW
417 CRS FACE TO BE MOUNTED
= =
NEAREST TO WALL
= =
97
172 CRS

125
=
242 CRS
489

=
220

COMPLETED SYSTEM
30
TOP VIEW SIDE VIEW
167

Wall Mounting
Bracket
461

1001
979

834
519

66

CROSS BRACE
= = ADJUSTABLE FEET

ANGLE BRACKET WALL/SOLID STRUCTURE


626
81
Consultants Specification
SIL- WM2 OPERATION
The unit offers the facility to be fitted directly to the MVHR unit and The supply and extract ventilation unit shall be positioned as indicated
plenum chamber without the need for spigots reducing breakout noise. on the drawings and shall be in accordance with the particular fan
However, there is the capability to fit 125mm circular spigots as an schedule in the specification. This unit is also available in Opposite
alternative option. Hand formatting.
The unit shall be fully lined with acoustic material offering excellent The combined supply and extract with heat recovery unit, shall supply
noise reduction. filtered fresh air to each of the habitable rooms and vitiated air shall be
extracted from the wet areas e.g. bathroom, en-suite, w.c, kitchen, utility
Wall mounting brackets are to be supplied as part of the system to allow
rooms, etc. The supply air shall be pre-heated by the warm extract air via
the MVHR unit to be raised after other system components are installed
the integrated counter-flow heat exchanger element. The extracted air
to form an airtight seal and enable the installation to be levelled.
shall also be filtered before it reaches the heat exchanger block.
The unit shall be clamped to the MRXBOX95(AB)-WM2 unit to provide
The ventilation unit shall vary its speed and therefore the ventilation
an efficient seal and ensure correct alignment.
rate, as it receives signals from the switched live signal from light/
The unit shall be fixed in position during installation as a standalone remote switches or any ancillary sensors. When signals are received, the
section without relying on other system elements. fan shall alter its speed to adjustable, normal and boost rates.

FF-WM2 The unit shall have the facility to commission the supply and extract
fans independently on minimum speed (continuous background
The unit shall be supplied with 204mm x 60mm rectangular spigots to
ventilation), and boost speed, via inbuilt minimum and maximum
connect to the duct run, with the ability to be fitted in eight separate
speed adjustment. The fans shall have infinitely variable speed control.
positions reducing the requirement for bends in the system.
The unit offers the facility to be fitted directly to the mating sections INTEGRAL AUTOMATIC SUMMER BYPASS
without the need for spigots reducing breakout noise, additional (MRXBOX95AB-WM2 & MRXBOX95AB-WM2-OH only)
125mm circular spigots to be supplied as an alternative option. Including Automatic SUMMER BYPASS where intake and return air
temperatures shall be measured so that supply air temperatures can be
TECHNICAL DATA maximised during winter months and minimised as external ambient
Units shall be one of MRXBOX95AB-WM2, MRXBOX95-WM2, temperature rises. The Summer Bypass damper shall be opened by a
MRXBOX95AB-WM2-OH, MRXBOX95-WM2-OH as manufactured wax actuator. Supply and Extract air shall be filtered irrespective of the
by Nuaire. bypass setting (open or closed).

SPECIFICATION CONTROL OPTIONS


The unit shall be fully insulated providing excellent thermal and All versions shall have the following functions integrally mounted
acoustic characteristics and shall be complete with a multi plate within the fan unit on a purpose made PCB, all such components
counter flow high efficiency heat exchanger block, with a thermal pre- wired and factory fitted by the manufacturer:
efficiency of up to 95%. The heat exchanger shall be protected by G3
Independent control of background supply and extract flow rates.
grade filters on fresh air inlet and system extract. The heat exchanger
Independent control of boost speed supply and extract flow rates.
and filters shall be accessible via the front access panel, enabling quick
Integral fan failure indication.
and easy maintenance.
Integral S/L terminal for boost from remote switch, e.g. light switch,
The unit shall have low energy, high efficiency EC fan/motor kitchen boost switch.
assemblies with sealed for life bearings, the impellers shall be backward Integral heat exchanger frost protection.
curved centrifugal type. The motors shall be suitable of an ambient Discreet daily run monitor.
temperature of 40C. Integral humidistat.
The unit shall be supplied complete with a condensate drip tray and OPTIONAL CONTROLS
21.5mm drain connection.
MRXBOX95-RFI Remote fail indicator.
The unit shall be suitable for 125mm diameter circular ducting.
MRXBOX95-PIR (Passive Infra-Red) A low voltage sensor which detects
The breakout noise level and power requirements shall be as detailed movement and activates system.
by the unit manufacturer and in accordance with the ventilation
MRXBOX95-HUM A low voltage sensor which activates the system
equipment schedule.
when the relative humidity level is above a set point.
The unit shall be offered with a 5 year warranty.
MRXBOX-VSC An LCD controller for MVHR system with a 3.5 touch
screen display.

82
82
Notes

83 83
Notes

84 84
NUAIRE
Western Industrial Estate
Caerphilly
CF83 1NA

Residential product orders or enquiry:


Tel: +44 (0)29 2085 8500
Fax: +44 (0)29 2085 8555
residential.enquiries@nuaire.co.uk

After sales technical support:


Tel: +44(0)29 2085 8400
Fax: +44(0)29 2085 8555
technicalsupport@nuaire.co.uk

www.nuaire.co.uk
@NuaireHomes

As part of our policy of continuous product development Nuaire reserves the right to alter specifications without prior notice.
Telephone calls may be recorded for quality and training purposes.
8585
11.16