2
Vertical Power Units
Note: Nachis policy of constantly improving its products, specifications are subject to change without notice. 3
Vertical Power Units
Operating Instructions Most foreign material and contaminents Pressures shown will load AC electric
Fill reservoir with new premium grade will be trapped by the return line filter motors to their nameplate horsepower
hydraulic fluid (Mobil DTE26 or equal). It after a few hours of operation. The return rating. Pressures shown should not be
is highly recommended to filter all line filter element should be replaced exceeded when system must be started
hydraulic fluid before filling the reservoir. when gauge indicates. (See pg. 8 for at full pressure. Momentary pressures
Fluid level gauge will indicate proper spare element numbers). Most industrial higher than those listed can be applied if
level. Electric motor wiring must conform applications should operate at a sufficient operating time at lower pump
to the motor wiring nameplate. Jog motor temperature below 140 degrees pressure or lower motor load during the
to check proper rotation, indicated by the fahrenheit. At higher temperatures, cycle will provide for motor cooling. Dead
rotation arrow on the unit. Incorrect problems are often experienced in head pressure loading would require full
rotation can be reversed by interchanging maintaining reliable and consistent motor HP using a constant displacement
any two lines on a three phase motor. hydraulic control. Component service life gear pump. Dead head pressure with a
is also reduced and hydraulic oil pressure compensated Piston or Vane
Relief or compensator control valve deteriorates. If the system tends to pump would require a small percentage
should be set at lowest pressure setting operate at an elevated temperature of the full flow loading, consequently
for startup. Decrease pressure by turning level, steps must be taken to reduce this generating less heat. Actual HP require-
the adjusting screw counterclockwise. If elevated operating temperature. ments depend on the duty cycle and
pump does not prime, vent pump operating conditions. This is many times
pressure line to atmosphere and into an Once a year or every 4000 hours of
operation, the reservoir's air breather best determined by actual testing by the
open container to establish flow. After customer.
pump has primed, reconnect pressure filter and the suction strainer should be
line and run at lowest pressure setting to replaced. The reservoir oil should be The components and piping are designed
purge air from the system piping. drained, and the reservoir cleaned. for the use of petroleum base fluids.
Recheck the fluid level in the reservoir, as Dusty or contaminated environments
some fluid could be lost in the filling of may require more frequent cleaning and
piping and components. maintenance.
5 Horsepower and larger can only be used on 10 gallon and larger reservoirs.
* Using this horsepower could cause pump to exceed maximum rated pressure
4 Note: Nachis policy of constantly improving its products, specifications are subject to change without notice.
Vertical Power Units
Reservoir Code
How to Order
REPLACEMENT ITEMS:
MOTOR ENCLOSURE
Totally enclosed motors (TEFC) are intended for
use where moisture, dirt, and/or corrosive
materials are present in indoor or outdoor
locations.
MOTOR VOLTAGE
Note: Nachis policy of constantly improving its products, specifications are subject to change without notice. 5
Vertical Power Units
MODULAR VALVES
ADD F FOR OPTIONAL
HYDRAULIC SHOCKLESS
SOLENOID
OG* - Reducing *
D03 SIZE ONLY
OR* - Relief *
OY - Flow Regulator
OC* - Check *
OCP* - Pilot Check *
6 Note: Nachis policy of constantly improving its products, specifications are subject to change without notice.
Vertical Power Units
System Pressure
Requirement PSI
Pump style Gear Vane Piston
GPM x PSI
Horsepower Requirement HP = HP
1714 x Std E(85%) PSI
Reservoir Code
Relief Valve pressure Range 150 ~ 1500 psi 250 ~ 3000psi Not Required
Manifold Code
Manufacturing Approved By (with date) Checked By (with date) Created By (with date)
Number Nachi Manager Nachi Engineer
Note: Nachis policy of constantly improving its products, specifications are subject to change without notice. 7
Vertical Power Units
Hydraulic Schematics
8 Note: Nachis policy of constantly improving its products, specifications are subject to change without notice.
Vertical Power Units
Standard Unit
Measurements are approximate. Where
dimensions are critical, obtain special
quotation.
F B
7
(4) 16 Dia. Mounting Holes
(VALVE MOUNTING SURFACE) J
G 3
8
C
F B F B
7 H 7 H
(4) 16 Dia. Mounting Holes (4) 16 Dia. Mounting Holes
7 G 7 G
16 C 16 C
X X
A A
E D
Note: Nachis policy of constantly improving its products, specifications are subject to change without notice. 9
Vertical Power Units
Standard Unit
Measurements are approximate. Where
dimensions are critical, obtain special
quotation.
D B D B
7 7 7
7 E (4) 16 Dia. Mounting E
(4) 16 Dia. Mounting Holes 16 Holes 16
C C
X X
A A
NV20 Thru NV30 Gallon w/Intank Filter NV20 Thru NV30 Gallon w/Inline Filter
X
UNIT DIMENSIONS (INCHES) HORSEPOWER
(TEFC)
RESERVOIR
A B C D E F G H J 1 10 5/8
1.5 10 5/8
NV5 10 12.5 14.5 - - 10 13.5 1.25 .05 2 11 5/8
3 12 1/4
NV10 19.7 16.5 19 - - 14 13.5 1.25 .075
5 14 1/2
10 Note: Nachis policy of constantly improving its products, specifications are subject to change without notice.
Vertical Power Units
Manifold Dimensions
5 - 1/4
B Typ. A B
C
A
RV
Relief Valve
5/8
D
5 - 1/4
B SAE Customer Connection
P RV
C
A
D Relief Valve
1 - 5/8
Note: Nachis policy of constantly improving its products, specifications are subject to change without notice. 11
Vertical Power Units
Note:
1. Bolt kits to be ordered separately when using modulars.
2. Bolt kits are furnished with directional valves when no modulars are required.
3. All DO3 modulars are 40mm thick.
4. DO5 modulars are 55mm thick.
12 Note: Nachis policy of constantly improving its products, specifications are subject to change without notice.
Horizontal Power Units
Air Breather/Filter
Combination
Reservoir Fill Port
Note: Nachis policy of constantly improving its products, specifications are subject to change without notice. 13
Horizontal Power Units
Operating Instructions Most foreign material and contaminents Pressures shown will load AC electric
Fill reservoir with new premium grade will be trapped by the return line filter motors to their nameplate horsepower
hydraulic fluid (Mobil DTE26 or equal). It after a few hours of operation. The return rating. Pressures shown should not be
is highly recommended to filter all line filter element should be replaced exceeded when system must be started
hydraulic fluid before filling the reservoir. when gauge indicates. (See pg. 8 for at full pressure. Momentary pressures
Fluid level gauge will indicate proper spare element numbers). Most industrial higher than those listed can be applied if
level. Electric motor wiring must conform applications should operate at a sufficient operating time at lower pump
to the motor wiring nameplate. Jog motor temperature below 140 degrees pressure or lower motor load during the
to check proper rotation, indicated by the fahrenheit. At higher temperatures, cycle will provide for motor cooling. Dead
rotation arrow on the unit. Incorrect problems are often experienced in head pressure loading would require full
rotation can be reversed by interchanging maintaining reliable and consistent motor HP using a constant displacement
any two lines on a three phase motor. hydraulic control. Component service life gear pump. Dead head pressure with a
is also reduced and hydraulic oil pressure compensated Piston or Vane
Relief or compensator control valve deteriorates. If the system tends to pump would require a small percentage
should be set at lowest pressure setting operate at an elevated temperature of the full flow loading, consequently
for startup. Decrease pressure by turning level, steps must be taken to reduce this generating less heat. Actual HP require-
the adjusting screw counterclockwise. If elevated operating temperature. ments depend on the duty cycle and
pump does not prime, vent pump operating conditions. This is many times
pressure line to atmosphere and into an Once a year or every 4000 hours of
operation, the reservoir's air breather best determined by actual testing by the
open container to establish flow. After customer.
pump has primed, reconnect pressure filter and the suction strainer should be
line and run at lowest pressure setting to replaced. The reservoir oil should be The components and piping are designed
purge air from the system piping. drained, and the reservoir cleaned. for the use of petroleum base fluids.
Recheck the fluid level in the reservoir, as Dusty or contaminated environments
some fluid could be lost in the filling of may require more frequent cleaning and
piping and components. maintenance.
Reservoir Code
How to Order
MOTOR ENCLOSURE
Combination of reservoir and pumps are Nachi standard horizontal power units come with totally
generally a 2:1 reservoir to pump flow ratio. enclosed fan cooled motors (TEFC). These motors are
Smaller pump and motor combinations intended for use where moisture, dirt, and/or corrosive
materials are present in indoor or outdoor locations.
may be mounted on larger reservoirs.
MOTOR VOLTAGE
All standard horizontal power units come with
3 PHASE - 208-230/460V, 60HZ
(Single phase and special voltages available upon request)
Note: Nachis policy of constantly improving its products, specifications are subject to change without notice. 15
Horizontal Power Units
OR* - Relief *
OY - Flow Regulator
OC* - Check *
OCP* - Pilot Check *
16 Note: Nachis policy of constantly improving its products, specifications are subject to change without notice.
Horizontal Power Units
System Pressure
Requirement PSI
Reservoir Code
Relief Valve pressure Range 150 ~ 1500 psi 250 ~ 3000psi Not Required
Manifold Code
Manufacturing Approved By (with date) Checked By (with date) Created By (with date)
Number Nachi Manager Nachi Engineer
Note: Nachis policy of constantly improving its products, specifications are subject to change without notice. 17
Horizontal Power Units
HYDRAULIC SCHEMATICS
18 Note: Nachis policy of constantly improving its products, specifications are subject to change without notice.
Horizontal Power Units
Standard Unit
Measurements are approximate. F H
Where dimensions are critical, obtain
special quotation.
G K
7/16
TYP
COOLER OPTION:
A01 -- 3.22
AO2 -- 5.11
AO3 -- 5.85
L J
E D
B A
Note: Nachis policy of constantly improving its products, specifications are subject to change without notice. 19
Horizontal Power Units
CONSULT FACTORY
2 Station 12.00 12.00
NH20 26 16 15.5 25.2 15 3.38 7 3 Station 12.00 12.00
4 Station 12.00 15.25
NH30 26 16 21.5 25.2 15 3.38 7
5 Station 14.25 18.50
NH40 26 16 27.5 25.2 15 5.38 9.25 6 Station 16.25 21.75
MOTOR HORSEPOWER
2 3 5 7.5 10 15 20
J 9.95 11.88 11.88 13.50 13.50 16.59 16.59
K 7.04 8.08 8.08 9.31 9.31 10.96 10.96
20 Note: Nachis policy of constantly improving its products, specifications are subject to change without notice.
Horizontal Power Units
GPM Max Hp
Removed
A01 15 .85 HP
A02 20 1.50 HP
A03 24 2.50 HP
A04 24 2.85 HP
Note:
1. Bolt kits to be ordered separately when using modulars.
2. Bolt kits are furnished with directional valves when no modulars are required.
3. All DO3 modulars are 40mm thick.
4. DO5 modulars are 55mm thick.
Note: Nachis policy of constantly improving its products, specifications are subject to change without notice. 21
NSP Power Units
FEATURES
Space-Saving Lightweight Design New Structure Increases Efficiency Greatly Improved Cooling Capacity
A smaller tank capacity makes the Based on years of experience, the A powerful, energy-efficient built-in
power unit more compact, and structure includes an improved pump cooling system eliminates the need
greatly reduces space requirements. joint that provides more efficient for fan motor wiring and coolant
operation. pipes.
SPECIFICATIONS
Item Model No. NSP-*-*V0A* NSP-*-*V1A* NSP-*-*V2A*
Pump Capacity cm3 /rev. {in3/rev} 8.0 {0.49} 16.0 {0.98} 26.0 {1.59}
Maximum pressure MPa {psi} 8.0 {1160} (Full cutoff pressure) 7.0 {1015} (Full cutoff pressure)
Allowed peak pressure: 13.0 (1885)
Motor Output kW {HP} 0.75 {1}, 1.5 {2} 1.5 {2}, 2.2 {3} 2.2 {3}, 3.7 {5}
Tank Capacity l {gallon} 20 {5.28} 30 {7.92}, 40 {10.57}
Installation space mm {inch} 300 X 400 {11.81 x 15.75} 340 x 450 {13.39 x 17.72}
Approximate weight kg {lbs} 39 {86} (20 l, 1.5kW) 63 {139} (30 l, 2.2kW,
excluding options)
22 Note: Nachis policy of constantly improving its products, specifications are subject to change without notice.
NSP Power Units
Model Code
How to Order
NSP 10 07 V 0 A2 2TF E13
Design number
E13 220 Volt 60 Hz
E13G 460 Volt 60 Hz
E13M 230 Volt 60 Hz
Option (Indicate in alphabetic sequence.)
F*: Built-in block*=1~3
Pressure adjustment range (A: constant discharge type)
A2: 1.5 to 4.0 MPa (507 psi) Pressure gauge scale 16 MPa
A3: 3.5 to 6.0 MPa (725 psi) Pressure gauge scale 25 MPa
A4: 5.5 to 8.0 MPa (1015 psi) Pressure gauge scale 25 MPa
Note: 1. Figures in parentheses show factory default full cutoff set values.
Flow rate adjustment range (Maximum capacity)
0: 8 cm 3/ rev (.49 cu in)
1: 16 cm3/ rev (.98 cu in)
2: 26 cm/ rev (1.59 cu in)
Note: 2. Factory defaults are maximum values shown above.
Pump type: Variable vane pump
Motor capacity: 07: 0.75 kW (1 HP)
Note: 1. Note that there are certain
15: 1.5 kW (2 HP)
restrictions on pump capacity
22: 2.2 kW (3 HP) and motor capacity combinations.
37: 3.7 kW (5 HP) 2. Design numbers are subject to
Tank volume: 10, 20, 30, 40 l change without notice.
NSP 20L 07 V 0 A2 F 13
Design number
13 220 Volt 60 Hz
13G 460 Volt 60 Hz
13M 230 Volt 60 Hz
Option (Indicate in alphabetic sequence.)
F*: Built-in block*=1~2 Temp gauge standard
Pressure adjustment range (A: constant discharge type)
A2: 2.0 to 4.0 MPa (507 psi)
A3: 3.5 to 6.0 MPa (725 psi)
A4: 5.5 to 7.0 MPa (1015 psi)
Note: 1. Figures in parentheses show factory default full cutoff set values.
Flow rate adjustment range (Maximum capacity)
0: 8 cm / rev (.49 cu in)
1:16cm/ rev (.98 cu in)
Pump type: Variable vane pump
Dimensional Drawings
8.0, 16.0 cm 3/ rev Series
Air flow
NSP-*-**V*A*-13 2-unit lifting lug R c1/2 R c1/2 R c3/4
(M8 P T DR
(Above oil
level)
4
17.50.2( 0.69)
P :R c1/2 3
3 0.8
(LA )
4~M8 14 ( 17)
LB
5
64(2.52)
38.10.2( 1.5) (Above oil level)
6
SA E J 518b-1/2 P R c1/2
DR R c3/4 7
(1.97) (1.97)
50 50
T R c1/2
Details of flange mounting Flange
mounting 1 2
5(0.20)
Oil port also
serving
5 2-unit lifting lug
Note: The unit lifting lug (eye-bolt and eye-nut) also
serves as a screw for assembling the tank. If it
140 45( 1.77) (M8 eye-bolt) is removed, the tank upper plate will be removed.
( 5.51)
300( 11.81)
(LE )
3~M4 Oil level gauge
(LF )
6
(LG )
(LC )
LI
Handling
22( 0.87)
LH
procedure
2
PART NO. PART NAME
1 Oil tank 40( 1.58) 145( 5.71) 4~ 13 Trioxane
Drain port
R c3/8 12 12
( 0.47) 376( 14.80) ( 0.47)
2 Suction strainer 25( 0.98)
240( 9.45)
25( 0.98)
400( 15.75)
290( 11.42)
3 Uni-pump
4 Pressure gauge
Fluid supply port/
5 air breather
6 Fluid level gauge
7 Radiator
8 Flexible hose
9 Flexible hose
24 Note: Nachis policy of constantly improving its products, specifications are subject to change without notice.
NSP Power Units
P T DR
4 to M8x15
Above oil level
(0.69)
38.1
17.5
(1.50) 4
9 8
3
3 SA E J 518b-1/2
Flange mounting surface details 0.8 3.7kW.4P
LB
LA
8 5
6
7
DR:Rc3/4 (Above oil level) 9
P:Rc1/2
(2.16)(2.16)
55 55
T :Rc3/4 2 1 30 L
Flange mounting
(3.27)
83
surface
Oil supply port/
(0.35)
150 55
9
5 air breather (5.90) (2.16)
LJ 350
(13.78)
366
(14.41)
7
PART NO. PART NAME Fluid level
LE
6
LF
1 Oil tank LG
HIGH
2 Suction strainer
LC
Upper limit H
1
LI
LOW
4 Pressure gauge 2
LH
(1.06)
27
9 Flexible hose
Note: Nachis policy of constantly improving its products, specifications are subject to change without notice. 25
NSP-L Power Units
Dimensional Drawings
8.0, 16.0 cm 3/ rev Series 20.00
NSP-20L-**V*A*-13 18.00
6.00
6.00
0.88
14.00
12.82
11.00
7.91
1.00
0.19 23.00
0.38
14.00
3/4" PORT PLUGGED 1/2" PORT WITH DOWNSPOUT
1.50
12.82
5 M 2 UVN-1A-1A4-1.5-4-11
Pump Motor
6 3 SUS-A088-068-N16F
4 Strainer
4 948-173 3/4 Ball Valve
3
5 3A92-001-1050 Cooler
1 6 SM57XL-10 Filler/Breather
NSP-20L-07V0A*-(*)-E13
NSP-20L-15V0A*-(*)-E13
NSP-20L-15V1A*-(*)-E13
( ) 220V 60 Hz
(G) 460V 60 Hz
(M) 230V 60 Hz
26 Note: Nachis policy of constantly improving its products, specifications are subject to change without notice.
NSP Power Units
Option Details
4 to 8.5 drilling
4 to 8.5 drilling Rc3/8
Rc3/8 126
14 x 10 counterbore
14 x 10 counterbore 38.1 0.2 38.1 0.2
28 28
A A A
27
T P T P T
27
P
78
78
58
B B
38
58
To
17.5 0.2
38
To
17.5 0.2
49 77 49
77
150 (30) 78
106 (30) 78
15
15
B1 B2
B
34
P P
49
34
63
49
T T
63
A A1
A2
4 to Rc3/8 28 28
6 to Rc3/8 59
59
95
89
F1 126 F2
176
4 to 8.5 drilling
To
38.1 0.2 Rc3/8
14 x 10 counterbore 78
15.5
49
28
A A A
PT PT PT
78
58
38
17.5 0.2
B B B
127
200 (30) 78
15
B1 B2 B3
34
P
49
63
T
A1 A3
A2
28
8 to Rc3/8 78
109
145
176 F3
NSP-10-07V0A2-F2-E13
(01) (01)
Rc1/2 Rc3/4 2 to Rc3/8
T DR P T
(Above
oil level)
B1 A1 4 to Rc3/8 B2 A2
(403)
400
0.8 0.75kW.4P
DR:Rc3/4 (Above oil level)
50 50
T:Rc1/2 M
10 L
(3)
45
A1 A2 B1 B2 4 to Rc 3/8
300 P T 2 to Rc 3/8
(30)
78
(262)
(154)
160
(22)
Note: Nachis policy of constantly improving its products, specifications are subject to change without notice. 27
NSP Power Units
UVN Uni-Pump
Drain Port (5.04)
2.83
(2.40)
Flow Rate
1.97
3.27
1.97 Adjusting Screw
Pressure
Adjusting Screw
H
I
J
2.68
0.43
0.43
2.20
1.10
0.83
2.05
C
S
G
R* E E Gauge Port
T
M
Auxillary View Y
(4-locations)
Auxillary View X
Pump Out 3.56 L
BSPT 1/2 and 2.70 O
P
SAE J518b 1/2 A Wiring Connection
G 3/4
0.69 X
1.50
KB
KD
1.02 F F
Pump In N
2.74 IL
BSPT 3/4
28 Note: Nachis policy of constantly improving its products, specifications are subject to change without notice.
NSP Power Units
NSP-10-07V0A2-13 PUMP/MOTOR UVN-1A-0A2-07E-4M-11 1.4 GPM TO 3.8 GPM 217 PSI TO 580 PSI
NSP-10-07V0A3-13 UVN-1A-0A3-07E-4M-11 1.4 GPM TO 3.8 GPM 507 PSI TO 870 PSI
NSP-10-15V0A4-13 UVN-1A-0A4-15E-4M-11 1.4 GPM TO 3.8 GPM 797 PSI TO 1160 PSI
NSP-20-15V1A2-13 PUMP/MOTOR UVN-1A-1A2-15E-4M-11 3.7 GPM TP 7.6 GPM 217 PSI TO 580 PSI
NSP-20-22V1A3-13 UVN-1A-1A3-22E-4M-11 3.7 GPM TP 7.6 GPM 507 PSI TO 870 PSI
NSP-20-22V1A4-13 UVN-1A-1A4-22E-4M-11 3.7 GPM TP 7.6 GPM 797 PSI TO 1160 PSI
NSP-30-22V2A3-13 PUMP/MOTOR UVN-1A-2A3-22E-4M-11 3.7 GPM TO 12 GPM 507 PSI TO 870 PSI
NSP-30-22V2A4-13 UVN-1A-2A4-22E-4M-11 3.7 GPM TO 12 GPM 797 PSI TP 1160 PSI
NSP-30-37V2A3-13 UVN-1A-2A3-37E-4M-11 3.7 GPM TO 12 GPM 507 PSI TO 870 PSI
NSP-30-37V2A4-13 UVN-1A-2A4-37E-4M-11 3.7 GPM TO 12 GPM 797 PSI TP 1160 PSI
NSP-40-22V2A3-13 PUMP/MOTOR UVN-1A-2A3-22E-4M-11 3.7 GPM TO 12 GPM 507 PSI TO 870 PSI
NSP-40-37V2A4-13 UVN-1A-2A4-37E-4M-11 3.7 GPM TO 12 GPM 797 PSI TP 1160 PSI
Note: Nachis policy of constantly improving its products, specifications are subject to change without notice. 29
NSP Power Units
Example Solution
Find the motor to be used at a pressure of 3.5MPa Since the intersection of the two broken lines from a pressure of
{508psi} and discharge rate of 12l/min {3.2gpm}. 3.5MPa {508psi} and discharge rate of 12l/min {3.2gpm} intersect
in the area under the 1.5kW curve, it means that a 1.5kW motor
should be used.
50Hz 60Hz
07 15 2.2
13 13 13
15 9.2 22 15.8
3.7
6.6 3.7kw
10.5
Discharge rate Q
2.6 5.2
0.75kw 1.5kw 7.9
3.9 2.2kw
5.2
1.3 2.6
1.3 2.6
0 2 4 6 8 0 2 4 6 8 0 2 4 6 8
290 580 870 1160 290 580 870 1160 290 580 870 1160
Discharge pressure P psi Discharge pressure P psi Discharge pressure P psi
30 Note: Nachis policy of constantly improving its products, specifications are subject to change without notice.
NSP Power Units
Performance Characteristics
Power Consumption Noise Characteristics Conditions
Type: NSP-**-22V*A4-12 Type: NSP-20-*V*A4-12
The value in the left-hand drawing represents typical
70
characteristics under the following conditions:
1.5
Power consumption L (kW)
Condition (Full cutoff: when pressure is held) Oil used: ISO VG32 or its equivalent
Motor - Number of poles: 2.2kW - 4P Oil temperature: 104 +/- 41F
(room temperatu)(F)
Oil temperature rise
68
FC pressure 5.0MPa {724psi}
68
Speed: 1800 min-1
FC pressure 7.0MPa {1014psi} Room temperature: 84F
FC pressure 3.5MPa {507psi}
FC pressure 5.0MPa {724psi}
Motor: 0.75~2.2kW
50 50 Notes:
FC pressure 3.5MPa {507psi} 1. For 5.0MPa (724 psi) of a 2.6 gallon tank. It
should be noted that there is a big rise in oil
32 32 temperature under continuous operation. In this
0 1 2 3 4 0 1 2 3 4 case, we recommend use of a 5.3 gallon tank.
Time (Hr) Time (Hr) 2. Rise of oil temperature depends on the conditions
of using an actual machine, and so may be
different from the above description in some cases.
typical characteristics
Noise level dB (A)
Note: Nachis policy of constantly improving its products, specifications are subject to change without notice. 31
Nachi America Inc.
715 Pushville Rd, Greenwood, IN 46143
Tel. (800) 622-4410 Fax. (317) 530-1015
Email: hydraulics@nachiamerica.com
www.nachiamerica.com
December 2015