Sie sind auf Seite 1von 10

Technical data F - 3/12

F1 Ambient The turbomachinery plant was designed for the following


conditions ambient conditions:

F 1.1 Temperature

Ambient temperature: Outdoors Indoors


min. 23 C
max. 36 C

F 1.2 Installation of All foundation loads are indicated on the foundation plan/
turbomachine outline plan.

Installation

Component
Turbomachine X X X X

AC Doc. No. IM_TP-18391_2_F_en_0_0


Codeword Tanjung Priok

8.2-65
F - 4/12 Technical data

F2 Supply For further information about electrical connections refer to


connections, circuit diagram in the annex.
electricity and For dimensions of pipe connections refer to P + I diagram
auxiliary and layout plan/outline plan.
materials

F 2.1 Electric energy for:

Energy per turbomachine unit


Component no. per Voltage Power/ Phase Frequency
unit V total kW Hz
Driver 1 380 3200 3 50
Space heater, driver 1 220 1.68 1 50
Lubricating oil pump motor 1 380 11.2 3 50
Oil heater 2 380 9.0 3 50
Control Cabinet (remote) 1 220 4.3 1 50
Panel devices
Control Cabinet (remote) 1 220 3.28 1 50
UPS devices
Splitter Box (remote) 1 220 1.2 1 50
Fan noise hood 2 380 1.6 3 50
Fan gas cooler/oil cooler 2 380 18.60 3 50

F 2.2 Oil filling

Quality ISO VG 32 For recommended lubricants, refer


to chapter "Works Standards"
located in the annex .
Quantity filling 1833 l

AC Doc. No. IM_TP-18391_2_F_en_0_0


Codeword Tanjung Priok

8.2-66
Technical data F - 5/12

F 2.3 Instrument air and Seal and flushing gases must meet the following requirements
seal gas regarding particle size:
5 m
Instrument air per unit

Pressure min. 3.45 bar(g)


max. 10.34
Dew point C
Consumption 35.2 Nm3/h total estimated, depends on
control proceedings

Seal gas per unit

Type Process
Pressure min. 41 bar(g)
max. 53.8
Dew point C
Consumption operation Nm3/h

Seal buffer gas per unit

Type Nitrogen
Pressure min. 3.45 bar(g)
max. 10.34
Dew point C
Consumption operation 32 Nm3/h

AC Doc. No. IM_TP-18391_2_F_en_0_0


Codeword Tanjung Priok

8.2-67
F - 6/12 Technical data

F3 Machine data

F 3.1 Name plate

AC Doc. No. IM_TP-18391_2_F_en_0_0


Codeword Tanjung Priok

8.2-68
Technical data F - 7/12

AC Doc. No. IM_TP-18391_2_F_en_0_0


Codeword Tanjung Priok

8.2-69
F - 8/12 Technical data

F 3.2 Process gas data

Operating point
Component Symbol MW
kg/kmol
Nitrogen N2 28.02 % 0.61
Carbon CO2 44.01 % 5.0
dioxide
Methane CH4 16.04 % 84.5
Ethane C2H6 30.07 % 4.91
Propane C3H8 44.09 % 2.88
i-Butane i-C4H10 58.12 % 0.79
n-Butane n-C4H10 58.12 % 0.6
i-Pentane i-C5H12 72.15 % 0.27
n-Pentane n-C5H12 72.15 % 0.17
Hexanes C6H14 86.16 % 0.15
Heptane C7H16 100.205 % 0.12

Corrosive
components traces
of:
Hydrogen sulfide H2S (Trace) ppm

AC Doc. No. IM_TP-18391_2_F_en_0_0


Codeword Tanjung Priok

8.2-70
Technical data F - 9/12

F 3.3 Compressor data

Operating point Design Rated


3
Volumetric flow Vn Nm /h 67000.0 67000.3
(1.013 bar(a) 0 C)
Inlet mass flow kg/h 60119.7 60120.0
Suction pressure at stage 1 bar(a) 17.113 17.113

Inlet temperature at stage 1 C 35.5 30.0


Gas pressure at last stage bar(a) 41.013 41.353

Discharge temperature
last stage C 111.77 105.91
Driving shaft speed min-1 2980 2980
Maximum speed of pinion shaft min-1 30079 30079

F 3.4 Lubricating system

Operating point
Oil pressure before bar(g) 2.1
turbomachinery
Oil temperature before C 43
turbomachinery

AC Doc. No. IM_TP-18391_2_F_en_0_0


Codeword Tanjung Priok

8.2-71
F - 10/12 Technical data

F 3.5 Sound level of


compressor plant

Operating point
with driver
Mean acoustic power dB(A)
L WA *)

Emission level L pA at work dB(A)


place, undamped *)
without driver
Mean acoustic power dB(A)
L WA *)

Emission level L pA at work dB(A)


place, undamped *)
*) Distance to measuring surface: 1m
Sound data tolerance: 2 dB

AC Doc. No. IM_TP-18391_2_F_en_0_0


Codeword Tanjung Priok

8.2-72
Technical data F - 11/12

F 3.6 Performance curves

AC Doc. No. IM_TP-18391_2_F_en_0_0


Codeword Tanjung Priok

8.2-73
F - 12/12 Technical data