Sie sind auf Seite 1von 2

Design

of Stepped End Column

Refer Appendix D Pg. 122 IS 800:2007

DL Self wt. IL CL
Load factor 1.5 1.5 1.5 1.05
Load in kN 11.8 10 0 21.2 54.96
Load in kN 0 0 53 0 79.5

USE ISMB 400


L2 = 2 m L1 = 8 m
P2 = 54.96 kN P1 = 79.5 kN
140 400 400
16

8.9 368 400

16
140 ISMB 400 ISMB 400
A 7846 mm2 A 15692 mm2
Ixx 2.05E+08 mm4 Ixx 4.09E+08 mm4
Iyy 6.22E+06 mm4 Iyy 2.52E+09 mm4
depending
upon the
axis of
I2 6.22E+06 mm4 I1 2.52E+09 mm4 buckling

I2 / I1 0.002 L2 / L1 0.25

Refer Table 38 - for pinned fixed connection


For K12 For K11
L2 / L1 L2 / L1
I2 / I1 0.2 0.25 0.3 0.2 0.25 0.3
0.05 1.66 1.88 2.1 0.67 0.745 0.82
0.002
0.1

2.447
C1 3.2189
K1 1.3315
K2 0.4136

Prepared by Sushank Dani 13/11/17 Page 1


Design of Stepped Middle Column

Refer Appendix D Pg. 122 IS 800:2007

DL Self wt. IL CL
Load factor 1.5 1.5 1.5 1.05
Load in kN 53 0 53 0 159

USE ISMB 400


L2 = 2 m L1 = 8 m
P2 = 109.92 kN P1 = 159 kN
140 400 400
16

8.9 368 400

16
140 ISMB 400 ISMB 400
A 7846 mm2 A 15692 mm2
Ixx 2.05E+08 mm4 Ixx 4.09E+08 mm4
Iyy 6.22E+06 mm4 Iyy 2.52E+09 mm4
depending
upon the
axis of
I2 6.22E+06 mm4 I1 2.52E+09 mm4 buckling

I2 / I1 0.002 L2 / L1 0.25

Refer Table 38 - for pinned fixed connection


For K12 For K11
L2 / L1 L2 / L1
I2 / I1 0.2 0.25 0.3 0.2 0.25 0.3
0.05 1.66 1.88 2.1 0.67 0.745 0.82
0.002
0.1

2.447
C1 3.2189
K1 1.3315
K2 0.4136

Prepared by Sushank Dani 13/11/17 Page 2