Form XIX

DETAILS TO BE FURNISHED ALONG WITH APPLICATION FOR INSPECTION OF


BOILER AFTER TWELVE MONTHS OF THE CERTIFICATION UNDER APPENDIX JA
1. Name and address of the Owner : Thermal Power Tech Corporation India Ltd
Pynampuram/Nelaturu Village,
Muthukur Mandal
SPSR Nellore District- 524344.

2. Registry number of the boiler : AP/6119


3. Quality of steam and its temperature : SH steam 570OC, RH Steam-603 OC
4. Rate of steam generation : 2105 TPH
5. Heating Surface : 65717 M2
6. Year of make : 2012
7. Brief description of boiler : Water tube boiler, Supercritical
pressure, single furnace, once reheat, balanced draught, outdoor arrangement, dry ash
extraction, coal firing.
8. Type of construction (whether riveted or welded) : Welded
9. Whether fired or waste heat boiler : Fired
10. Date of registration : 18.10.2014
11. Details of past exemption granted by the government,
if any : --
12. Last date of annual inspection : 3.5.2014
13. Expiry date of current certificates : 01.05.2015
14. Working pressure at which last certificate was issued : 260Kg/Cm2
15. Details of past repairs (year-wise) : --
16. Remark as entered in the last certificate : Pending steam testing
17. Quality of boiler feed water : DM Water
18. Whether requisite number of feed pumps are in satisfactory
Working condition at present? : Yes
19. Number of safety valves mounted on Shell/drum and
super Heater :6
20. Total number of soot blowers provided in boiler : 90
21. Number of blowers in working condition : 90

22. Whether safety valves are blowing satisfactorily at


or below design pressure ? : Yes. Blowed satisfactorily.
23. Whether safety valve assembly is free from jamming as
Verified by operating casing lever? : Yes. Free from jamming.
24. Whether high and low water level alarm is in good
Condition? : Yes
25. Whether main steam stop valves, feed check valves,
Blow down valves and master pressure gauges are in
working condition? : Yes
26. Whether additional requirements for automatic boilers
as per Regulation 281A are complied with? : Yes
(If No give details)
27. Latest date of calibration for master pressure,
temperature Indicator/recorder for super-heater,
hot reheat, cold reheat and main steam line : 27.5.2014
28. Latest date when boiler protection device were
satisfactorily tested : Protections checked last month.
29. Details of boiler tripping for last three months with
reasons thereof : No
30. Present irregularities in instruments and controls if any
Observed in control-room of boiler house : No
31. Details of present boiler leakage : No leaks
32. Present operating pressure of the boiler : 254
33. Date when boiler water sample tested last (enclose copy of
Test report showing TDS) : 01.05.2015
34. State at what intervals such test is carried out : Daily
35. When boiler was last opened for internal and/or external
Cleaning : No
36. State at what intervals such cleaning is carried out : Yearly

37. Whether there was any shut down since last inspection
When the boiler could have been offered for inspection : No
38. Whether working pressure of the boiler ever exceeded
in the Past beyond certified limit? If any give details : No
39. Details of boiler accident which took place in the past,
if any : No such incident
40. Whether state Boilers operation Engineers /Attendants
Rules are complied with? : Yes
41. Irregularities if any, noticed in the past in compliance
of Indian Boiler Act 1923 : Nil
42. Whether guidelines laid down by Central Boiler Board for
Granting exemption to the Waste heat boiler are fulfilled or not : N/A.

GENERAL MANAGER (Generation)