This time of the year is typically pretty hectic. Over the last couple months I did training for companies in
Atlanta, Denver, and Houston. And of course we were at AU 2012. All that to say, sorry for not posting!
Todays article is one topic we get asked about pretty frequently, and is one of the first customization
topics clients approach.
In another post I will show how our PDO Extended Fields plugin allows you more accuracy and flexibility
for including equipment tags, but this post will start off with the basics.
Remember to switch your tool palettes to the appropriate group for your project.
http://www.pdoteam.com/2012/12/implementing-off-page-connectors-in-autocad-pid/ 05-05-2015
Implementing Off Page Connectors in AutoCAD P&ID | Process Design, from the Ou... Page 2 of 9
Deciding on Attributes
Personally, I like to include the connected Equipment, the line number tag, and the connected drawing
name. Including these will force us to create a From Off Page Connector and a To Off Page connector
so that we can use different attributes from the line.
With this class selected, click Add Symbols. I recommend starting off with a copy of the existing block.
You can copy/paste in line work from an existing block at a later point, but it helps us start off with the
right attribute properties to work off the default symbol.
http://www.pdoteam.com/2012/12/implementing-off-page-connectors-in-autocad-pid/ 05-05-2015
Implementing Off Page Connectors in AutoCAD P&ID | Process Design, from the Ou... Page 3 of 9
To start off with the default PIP off page connector (OPC), browse to your current projects
projsymbolstyle.dwg. This file is crucial to storing project settings, so make sure its never purged.
The block name is PIP OFF-PLOT CONNECTOR; click Add to select the block. Click Next.
For the symbol name, From Off Page Connector, and well keep the default settings by clicking Finish
now.
http://www.pdoteam.com/2012/12/implementing-off-page-connectors-in-autocad-pid/ 05-05-2015
Implementing Off Page Connectors in AutoCAD P&ID | Process Design, from the Ou... Page 4 of 9
With the From Off Page connector symbol selected, click Edit Block. First, remember that we are in the
default opc, so we will use Save As to create a new block. Click the flyout on the Open/Save Panel and
click Save Block As.
Type in OPC From for the Block Name and click Ok.
The AttachmentPointX leaders are called Point parameters. AutoCAD P&ID uses these to figure out
where line should connect to blocks. The blue dimensions are linear parameters and then are associated
with stretch actions.
http://www.pdoteam.com/2012/12/implementing-off-page-connectors-in-autocad-pid/ 05-05-2015
Implementing Off Page Connectors in AutoCAD P&ID | Process Design, from the Ou... Page 5 of 9
The AutoCAD P&ID uses stretch actions to know what to change if the text overflows the block.
For more information on Dynamic Blocks I recommend checking out Matt Murphys class:
http://au.autodesk.com/?nd=class&session_id=5251
The attributes being populated by AutoCAD P&ID/Plant 3D, use a special formatting #(). When we
click the #() button, we get to choose how to populate an attribute or text. The target object property
allows use to use a property from more than once class. When we specify a class directly (like the
PipeLineGroup.Service) the program will try to use the objects relationship to locate that property.
The #(=Drawing.General.PnID) is a special value that pulls in the connected P&ID drawing. You can use
any drawing properties, just remember to put the = sign after the first parenthesis so that the connected
drawing is displayed and not the current drawing.
Before testing our block we need to change the Symbol to use the block we created using the Save As.
Click Edit Symbol and select the OPC From Block. Now, click Add to Tool Palette to add our new
symbol to the current tool palette.
Heres how I configured my OPC. The #(PipeLines.Tag) will put in the line number tag for the line
segment thats connected. The #(Pipelines.From) will put in the equipment that is connected to the
current line segment.
I will repeat the process and create an OPC To symbols so I can switch the styles of the OPCs as
needed.
http://www.pdoteam.com/2012/12/implementing-off-page-connectors-in-autocad-pid/ 05-05-2015
Implementing Off Page Connectors in AutoCAD P&ID | Process Design, from the Ou... Page 6 of 9
The final steps is to set the default symbol style for the Off Page Connector Class. With the Off Page
Connector Class selected, scroll down to the Graphical Styles Property and select our new From Page
Connector Style.
http://www.pdoteam.com/2012/12/implementing-off-page-connectors-in-autocad-pid/ 05-05-2015
Implementing Off Page Connectors in AutoCAD P&ID | Process Design, from the Ou... Page 7 of 9
Advanced OPCs
Some people like to have a to or from included with their OPCs. To include those, you can use fill in the
attribute with TO #(=Drawing.General.PnID) where space is created using a non-breaking space (hold
down the Alt key and enter 0160). You have to do this in an annotation though, as P&ID fills in the
symbol with only the property information.
Our video implementing the PDO XF Elevations demonstrates how this can be done in an annotation:
Implementing BOP Elevations in Orthographics
In those scenarios, you may want to create some subclasses of the off page connector so that you can
define a particular annotation to come in (ie To or From) along with your opc.
Related Posts:
Off Page Connectors with PDO Extended Fields
Sharing Awesomeness Part 2 Data Population in AutoCAD
Enhanced Fields for AutoCAD Plant Design
Creating Custom Image for Process Line Palettes
Sharing Awesomeness in AutoCAD Plant 3D Sending
Share this:
AUTOCAD PNID
Tags: AUTOCAD P&ID, OFF PAGE CONNECTORS
http://www.pdoteam.com/2012/12/implementing-off-page-connectors-in-autocad-pid/ 05-05-2015
Implementing Off Page Connectors in AutoCAD P&ID | Process Design, from the Ou... Page 8 of 9
LOGIN
Username
Password
Remember Me
Log In
Register
Lost Password
TOP POSTS
RECENT POSTS
Line Gaps not showing when publishing PDFs February 17, 2015
SERIES
http://www.pdoteam.com/2012/12/implementing-off-page-connectors-in-autocad-pid/ 05-05-2015
Implementing Off Page Connectors in AutoCAD P&ID | Process Design, from the Ou... Page 9 of 9
ARCHIVES ECAD
http://www.pdoteam.com/2012/12/implementing-off-page-connectors-in-autocad-pid/ 05-05-2015