IMPLEMENTING OFF PAGE CONNECTORS IN


AUTOCAD P&ID
Posted on DECEMBER 21, 2012 8:00 AM by DAVE WOLFE

This time of the year is typically pretty hectic. Over the last couple months I did training for companies in
Atlanta, Denver, and Houston. And of course we were at AU 2012. All that to say, sorry for not posting!

Todays article is one topic we get asked about pretty frequently, and is one of the first customization
topics clients approach.

In another post I will show how our PDO Extended Fields plugin allows you more accuracy and flexibility
for including equipment tags, but this post will start off with the basics.

To customize our off page connectors, we will follow these steps:

Decide which attributes we need to show in our connector.


Create a new symbol style.
Modify the block associated with the symbol style.
Test our new Symbols

Lastly well discuss some advanced options for your tags.

Remember to switch your tool palettes to the appropriate group for your project.

http://www.pdoteam.com/2012/12/implementing-off-page-connectors-in-autocad-pid/ 05-05-2015
Implementing Off Page Connectors in AutoCAD P&ID | Process Design, from the Ou... Page 2 of 9

Deciding on Attributes
Personally, I like to include the connected Equipment, the line number tag, and the connected drawing
name. Including these will force us to create a From Off Page Connector and a To Off Page connector
so that we can use different attributes from the line.

Create a new Symbol Style


The class we are concerned with is under P&ID DWG Settings > P&ID Class Definitions > Non-
Engineering Items > Connectors > Off Page Connector

With this class selected, click Add Symbols. I recommend starting off with a copy of the existing block.
You can copy/paste in line work from an existing block at a later point, but it helps us start off with the
right attribute properties to work off the default symbol.

http://www.pdoteam.com/2012/12/implementing-off-page-connectors-in-autocad-pid/ 05-05-2015
Implementing Off Page Connectors in AutoCAD P&ID | Process Design, from the Ou... Page 3 of 9

I am also working using the PIP symbol set.

To start off with the default PIP off page connector (OPC), browse to your current projects
projsymbolstyle.dwg. This file is crucial to storing project settings, so make sure its never purged.

The block name is PIP OFF-PLOT CONNECTOR; click Add to select the block. Click Next.

For the symbol name, From Off Page Connector, and well keep the default settings by clicking Finish
now.

Modifying our Symbol Block

http://www.pdoteam.com/2012/12/implementing-off-page-connectors-in-autocad-pid/ 05-05-2015
Implementing Off Page Connectors in AutoCAD P&ID | Process Design, from the Ou... Page 4 of 9

With the From Off Page connector symbol selected, click Edit Block. First, remember that we are in the
default opc, so we will use Save As to create a new block. Click the flyout on the Open/Save Panel and
click Save Block As.

Type in OPC From for the Block Name and click Ok.

You should see something like this:

The AttachmentPointX leaders are called Point parameters. AutoCAD P&ID uses these to figure out
where line should connect to blocks. The blue dimensions are linear parameters and then are associated
with stretch actions.

http://www.pdoteam.com/2012/12/implementing-off-page-connectors-in-autocad-pid/ 05-05-2015
Implementing Off Page Connectors in AutoCAD P&ID | Process Design, from the Ou... Page 5 of 9

The AutoCAD P&ID uses stretch actions to know what to change if the text overflows the block.

For more information on Dynamic Blocks I recommend checking out Matt Murphys class:
http://au.autodesk.com/?nd=class&session_id=5251

In our block we have four attributes that we need to discuss.

The attributes being populated by AutoCAD P&ID/Plant 3D, use a special formatting #(). When we
click the #() button, we get to choose how to populate an attribute or text. The target object property
allows use to use a property from more than once class. When we specify a class directly (like the
PipeLineGroup.Service) the program will try to use the objects relationship to locate that property.

The #(=Drawing.General.PnID) is a special value that pulls in the connected P&ID drawing. You can use
any drawing properties, just remember to put the = sign after the first parenthesis so that the connected
drawing is displayed and not the current drawing.

Before testing our block we need to change the Symbol to use the block we created using the Save As.
Click Edit Symbol and select the OPC From Block. Now, click Add to Tool Palette to add our new
symbol to the current tool palette.

Heres how I configured my OPC. The #(PipeLines.Tag) will put in the line number tag for the line
segment thats connected. The #(Pipelines.From) will put in the equipment that is connected to the
current line segment.

I will repeat the process and create an OPC To symbols so I can switch the styles of the OPCs as
needed.

http://www.pdoteam.com/2012/12/implementing-off-page-connectors-in-autocad-pid/ 05-05-2015
Implementing Off Page Connectors in AutoCAD P&ID | Process Design, from the Ou... Page 6 of 9

The final steps is to set the default symbol style for the Off Page Connector Class. With the Off Page
Connector Class selected, scroll down to the Graphical Styles Property and select our new From Page
Connector Style.

Testing our New Symbol


While we can insert new blocks for testing, we can also switch the style of existing blocks. Do both to
ensure that your symbol behaves as expected.

http://www.pdoteam.com/2012/12/implementing-off-page-connectors-in-autocad-pid/ 05-05-2015
Implementing Off Page Connectors in AutoCAD P&ID | Process Design, from the Ou... Page 7 of 9

Advanced OPCs
Some people like to have a to or from included with their OPCs. To include those, you can use fill in the
attribute with TO #(=Drawing.General.PnID) where space is created using a non-breaking space (hold
down the Alt key and enter 0160). You have to do this in an annotation though, as P&ID fills in the
symbol with only the property information.

Our video implementing the PDO XF Elevations demonstrates how this can be done in an annotation:
Implementing BOP Elevations in Orthographics

In those scenarios, you may want to create some subclasses of the off page connector so that you can
define a particular annotation to come in (ie To or From) along with your opc.

Related Posts:
Off Page Connectors with PDO Extended Fields
Sharing Awesomeness Part 2 Data Population in AutoCAD
Enhanced Fields for AutoCAD Plant Design
Creating Custom Image for Process Line Palettes
Sharing Awesomeness in AutoCAD Plant 3D Sending

Share this:

Facebook Google LinkedIn 4 Twitter Email More

AUTOCAD PNID
Tags: AUTOCAD P&ID, OFF PAGE CONNECTORS

Previous post Next post

http://www.pdoteam.com/2012/12/implementing-off-page-connectors-in-autocad-pid/ 05-05-2015
Implementing Off Page Connectors in AutoCAD P&ID | Process Design, from the Ou... Page 8 of 9

LOGIN

Username

Password

Remember Me

Log In

Register

Lost Password

TOP POSTS

Implementing Off Page Connectors in AutoCAD P&ID

Top Updates for Plant 3D 2016

Custom Components in AutoCAD Plant 3D

RECENT POSTS

Top Updates for Plant 3D 2016 April 24, 2015

Plant Design Suite 2016 April 17, 2015

Using Tolerances in Plant 3D 2016 April 15, 2015

Fast Track User Logging February 26, 2015

Line Gaps not showing when publishing PDFs February 17, 2015

SERIES

AutoCAD Plant 3D on SQL Express (5)

Converting CADWorx Specs (2)

Creating a Nozzle Report (2)

Custom Piping Components Plant 3D (3)

Custom PnID Lines (2)

Report Creator Scripts (2)

Sharing Projects with AutoCAD Plant 3D (3)

http://www.pdoteam.com/2012/12/implementing-off-page-connectors-in-autocad-pid/ 05-05-2015
Implementing Off Page Connectors in AutoCAD P&ID | Process Design, from the Ou... Page 9 of 9

POST CATEGORIES AUTODESK

Select Category + AutoCAD Plant 3D 2014 Object Enablers


+ Plant Exchange The Plant Exchange site that hosts
content and updates for the AutoCAD Plant platform

ARCHIVES ECAD

Select Month + ECAD Plugins


+ ECAD, Inc.
+ MDO Team
+ Plant 3d WishList

2015 ECAD, Inc. CW Magazine powered by WordPress

http://www.pdoteam.com/2012/12/implementing-off-page-connectors-in-autocad-pid/ 05-05-2015

Das könnte Ihnen auch gefallen