Beruflich Dokumente
Kultur Dokumente
proven solutions
Crude Oil Characterization for Sulfur, Nitrogen and Carbon from a Single Analysis
Fast Hydrocarbon, Nitrogen, and Sulfur Boiling Point Distribution Information
Comparable to ASTM D2887, D6352, D7500 and D7169 SIMDIS Methods
Advanced Hardware Design for Wide Boiling Point Range Coverage (FBP up to 700C and
Unique DHA Front End for Light End Fractions)
WWW.PACLP.COM
CNS SIMDIS
Lastly, they have an environmental interest that is getting increased LIGHT GAS OIL
C
N S
WWW.PACLP.COM
solid partners
proven solutions
SPECIFICATIONS
Ordering Information LOW TEMP CNS SIMDIS HIGH TEMP CNS SIMDIS
CCG6005A SIMDIS D2887 CNS 120V -
CCG6005C SIMDIS D2887 CNS 230V -
CCG6006A - SIMDIS High Temp CNS 120V
CCG6006C - SIMDIS High Temp CNS 230V
Utility Requirements
Carrier gas Helium (99.999%)
FID fuel Hydrogen (99.999%)
Nitrogen (99.999%)
and Air
Cooling Compressed dry air
System power 110 230 Volts
Accessories Included Operating manual, Calibration samples, Reference samples, Startup kit, Carrier gas filters, Oven exhaust detector
Factory plumbing for quick installation
Analysis Scope LOW TEMP CNS SIMDIS HIGH TEMP CNS SIMDIS
Comparable to ASTM D2887, D3710, D7096, ASTM D6352, D7500, D6417, D7213, D7398 and D7169, EN15199-3, IP545 (DHA FE)
ISO3924, IP406
Sample Type / Range Jet Fuel, Diesel Distillates, Base Oils, Lube base Stocks
Carbon Number Range C5-C44 C2-C90***
Boiling Point Range FBP < 538C (1000F) IBP > 151C (304F)
FBP <700C (1292F)
Sample Injection Neat 1-2% dilution
LOW TEMP CNS SIMDIS HIGH TEMP CNS SIMDIS
Analysis Performance
S N C S N C
Sensitivity * 1 pg/sec 3 pg/sec n.a. 1 pg/sec 3 pg/sec n.a.
Limit of Quantitation** 10 ppm 30 ppm n.a. 50 ppm 150 ppm n.a.
Linear Dynamic Range >10 3
>10 3
>10 7
>10 3
>10 3
>107
r / R (Concentration) ASTM ASTM ASTM ASTM
D5453 D4629 D5453 D4629
Stability of Response <10% for 10 consecutive runs in 5 hrs <10% for 10 consecutive runs in 5 hrs
Equimolarity <10% <10% n.a. <10% <10% n.a.
Selectivity S/C: 107 S/C: 107
N/C: 107 N/C: 107
* Corrected for mass reaching detector
** For distributions, single peak is more sensitive
*** With DHA FE addition (option)
Continuing research and development may result in specifications or appearance changes at any time
ABOUT PAC
PAC develops advanced instrumentation for lab and process Our solutions are from industry-leading brands: AC Analytical
applications based on strong Analytical Expertise that ensures Controls, Advanced Sensors, Alcor, Antek, Herzog, ISL, Cambridge
Optimal Performance for our clients. Our analyzers help our Viscosity, PSPI, and PetroSpec. We are committed to delivering
clients meet complex industry challenges by providing a low superior and local customer service worldwide with 16 ofce
cost of ownership, safe operation, high performance with fast, locations and a network of over 50 distributors. PAC operates as a
accurate, and actionable results, high uptime through reliable unit of Roper Technologies, Inc., a diversied technology company
instrumentation, and compliance with standard methods. and a constituent of S&P 500, Fortune 1000, and Russell 1000 indices.
Copyright 2016 PAC L.P. All rights reserved / CNS_SIMDIS-Rev1-06/16 www.paclp.com | www.linkedin.com/company/pac | http://www.youtube.com/paclp11