Inspection
Inspector: Julio G. Alvarado Negron InspectionDate: 11-Oct-2017
Affiliation: CIAPR InspectionTime: 04:00 AM PM
AreasInspected: ExteriorOnly ExteriorandInterior
SchoolBuildingDescription
Name: FORTUNATO JORGE CORONA SchoolCode: 41822
Address: CARR. 370 KM.6 HM.3 BO. BUENA VISTA, Las Marias, Puerto Rico Latitude: 18.2432
BuildingContact/phone: 827-2033 Longitude: -66.9538
BuildingStories: 2 NumberofBuildings: 3 SchoolDistrict: MAYAGUEZ

GeneralConditions Services&Other:
FloodedAreas: No PotableWaterService Unavailable
FloodedBuildings: Yes PotableWaterCistern Available
WaterDamages: Yes SewerService: Available
Mildew: Yes ElectricalPowerService: Unavailable
VentilationStatus: Adequate GeneratorAvailable: Unavailable
ACSystemStatus: Inadequate Gas(LP)StorageTank: Available
FireSuppressionSystem: N/A Window/DoorScreens: Available
ExhaustSystems: N/A DiningAreaStatus: Adequate
AccesstoBuildings: Inadequate KitchenEquipment: Adequate
SurroundingAreas: Inadequate RecreationalFacilities: Inadequate
Comments: Accessing to School 41822 requires to drive through a road potentially dangerous due to landslides.
At time of inspection, no power/water facilities were available.

DamageAssessment
ObservedConditions Assessment EstimatedDamage
Collapse,PartialCollapseorBuildingoffFoundation Moderate 10 to 30 percent
BuildingSignificantlyoutofplumborindanger Moderate 10 to 30 percent
Damagetoprimarystructuralmembers,crackingofwalls Minor/None None
Fallinghazardduetononstructuraldamage Minor/None None
Geotechnicalhazard,scour,erosion,slopefailure,etc. Moderate 10 to 30 percent
Electricallines/fixuressubmerged/leaningtrees Minor/None None
Other: Foundations damaged on Kitchen/Dining room Minor/None None

Notes: The school comprises a set of 3 buildings. The most affected one is the Kitchen/Dining room building which

Posting
Severeconditionsendangeringtheoverallschool/buildingaregroundsforanUnsafeposting.Localized
SevereandoverallModerateconditionsmayallowaRestrictedUseposting.Addcommentsasneeded:
Building1: UNSAFE (Red) Foundations damaged due to landslide
Building2: INSPECTED (Green)
Building3: INSPECTED (Green)
Building4: N/A
Building5: N/A
Recommendations
Review the structural condition of Building 1. Landslide is undermining main support beams. This presents a potential danger for
people in the building.

AdaptedfromATC45 CIAPR2017 Page1


SchoolBuildingRapidEvaluationSafetyAssessmentForm
FurtherActions
Barricadesneededinthefollowingareas:

EngineeringEvaluationrecommended: Structural Geotechnical Other


SubstantialDamagedeterminationrecommended
Otherrecommendations: Review the structural integrity of support beams under building 1.
Repair cyclone fence behind basketball court since it provides open access to dangerous zone.
Clean walls and water outlets currently plagued with mildew. Clean handicap access ramp currently with mildew.
Repair water cisterns currently damaged without proper top cover. Also they appear to be disconnected.

AdditionalMemoranda
- School FORTUNATO JORGE CORONA (41822) is located in a remote location in Las Marias, Puerto Rico. The main road to the
school is prone to landslides and damages due to Hurricane Maria devastation as well as continuous rains in the area.
- The school consists of 3 main buildings, 2 of them have 2 stories and a single story building. The building 1(B1) presents most of the
damage. This building contains the kitchen and dining area of the school.
- The damage to B1 consists in the main foundations, which clearly appear to be undermined by water/landslides. The grease trap
also appears visibly undermined by the slide.
- Other damages to the school are noted below:
-> The water cisterns (2) do not have proper coverage. The top covers were damaged/unavailable. Also the pipe connections
do not appear to be properly connected.
-> The fence behind the basketball court is fallen off, providing access to a dangerous zone
-> There is still tree debris inside the school
-> The handicap ramp is full with mildew, which presents a slippery surface when wet
-> There are walls with evident mildew and fungus
-> Electricity service is not available
- Supporting Photos were attached to the email containing this report.

InspectorData

Name: Julio G. Alvarado Negron


Julio G. Alvarado Negron
email: julio.alvarado@outlook.com
ReportCompleted: 16-Nov-2017

AdaptedfromATC45 CIAPR2017 Page2