MAINTENANCE MANUAL

D25RE2
0.2 to 2%
1:500 to 1:50

Press Ctrl + L for full screen

DOSATRON INTERNATIONAL, INC. 800-523-8499


STANDARD INSTALLATION

Inlet Outlet

Optional
accessories Union ball
200 mesh /80 check/check
Optional accessories: micron filter valve or
water
Pressure regulator Concentrate hammer
arrestor
Solenoid valves
Water meter
Flow restrictor
2
click for next step
DOSATRON INTERNATIONAL, INC. 800-523-8499
MAIN MENU

CHAPTER 1 REMOVING THE DISPENSER FROM INSTALLATION


CHAPTER 2 DISASSEMBLING THE DISPENSER
CHAPTER 3 REASSEMBLING THE DISPENSER
CHAPTER 4 PISTON MAINTENANCE
CHAPTER 5 AIR BLEED MAINTENANCE
CHAPTER 6 BY-PASS MAINTENANCE
CHAPTER 7 TROUBLESHOOTING GUIDE

Click on a specific chapter


or
Click for next slide

3
click for next step
DOSATRON INTERNATIONAL, INC. 800-523-8499
SPECIFICATIONS

D25RE2
Injection Range:
1:500 to 1:50 - 0.2 to 2%
Water Flow Range:
0.05 to 11 GPM
Operating Water Pressure:
4.3 to 85 PSI
Maximum Water Temperature:
104F 40C
Note: Normal safety precautions should be practiced when
working with chemicals and equipment.
4
click for next step
DOSATRON INTERNATIONAL, INC. 800-523-8499
CHAPTER 1

REMOVING THE DISPENSER FROM INSTALLATION

D25RE2
0.2 to 2%
1:500 to 1:50

Return to Main Menu


click for next slide
5

DOSATRON INTERNATIONAL, INC. 800-523-8499


REMOVING THE DISPENSER FROM INSTALLATION

After turning off the water and


relieving the pressure on the unit,
unscrew the dispenser inlet/outlet
couplings and allow it to drain.

Unscrew the suction tube nut


and remove the hose.

6
click for next step
DOSATRON INTERNATIONAL, INC. 800-523-8499
CHAPTER 2

DISASSEMBLING THE DISPENSER

D25RE2
0.2 to 2%
1:500 to 1:50

Return to Main Menu


click for next slide
7

DOSATRON INTERNATIONAL, INC. 800-523-8499


DISASSEMBLING THE DISPENSER

Unscrew and remove the lid.

8
click for next step
DOSATRON INTERNATIONAL, INC. 800-523-8499
DISASSEMBLING THE DISPENSER

Place the dispenser upside-down on a


table and remove the 4 dosing assembly
retaining screws.
Use a #2 Phillips screwdriver.

9
click for next step
DOSATRON INTERNATIONAL, INC. 800-523-8499
DISASSEMBLING THE DISPENSER

Pull the injection stem


assembly out of the body, and
let the solution drain out of it.

Caution:
Caution Stem may be full of
undiluted chemical. Be aware of
hazardous materials and take
the necessary precautions for
protection.

WATCH OUT FOR SPLASHING! 10


click for next step
DOSATRON INTERNATIONAL, INC. 800-523-8499
DISASSEMBLING THE DISPENSER

Grab the valve support and pull the piston out of the body, at
the same time, push the plunger up.

11
click for next step
DOSATRON INTERNATIONAL, INC. 800-523-8499
DISASSEMBLING THE DISPENSER
Dosing assembly - disassembly

Unscrew and
remove the barbed
fitting.

Unscrew and
remove the conical
nut.

12
click for next step
DOSATRON INTERNATIONAL, INC. 800-523-8499
DISASSEMBLING THE DISPENSER
Dosing assembly - disassembly

Remove the
anti-friction ring.
Unscrew and
remove the
adjusting nut
from the
sleeve.

13
click for next step
DOSATRON INTERNATIONAL, INC. 800-523-8499
DISASSEMBLING THE DISPENSER

Dosing assembly - disassembly

Remove the injection stem from the top


of the sleeve.

Gently remove the sleeve O-ring.

14
click for next step
DOSATRON INTERNATIONAL, INC. 800-523-8499
DISASSEMBLING THE DISPENSER
Dosing assembly - disassembly

Gently push the check valve out of the


injection stem with a pencil or similar
object. Do not scratch the inside of the
injection stem.

Gently remove the injection stem O-ring.

15
click for next step
DOSATRON INTERNATIONAL, INC. 800-523-8499
DISASSEMBLING THE DISPENSER
CLEANING & MAINTENANCE PROCEDURE
When disassembly of the Dosatron unit is complete, soak it in lukewarm soapy
water. A soft bristled brush may be used to break up residue.
J009
Change seal kit every 12 months.
Seal kit part # ED252 includes:

J009 - Plunger seal


PJ121 - Injection stem assembly
J024 - Injection sleeve O-ring
MPDI122 - Check valve assembly
J051 - Check valve seal

16
click for next step
DOSATRON INTERNATIONAL, INC. 800-523-8499
CHAPTER 3

REASSEMBLING THE DISPENSER

D25RE2
0.2 to 2%
1:500 to 1:50

Return to Main Menu


click for next slide
17

DOSATRON INTERNATIONAL, INC. 800-523-8499


REASSEMBLING THE DISPENSER

Dosing assembly

Replace the O-ring on the dosing stem.

18
click for next step
DOSATRON INTERNATIONAL, INC. 800-523-8499
REASSEMBLING THE DISPENSER
Dosing assembly

Reinsert the injection stem into the injection sleeve. Make sure that the long groove
in the injection stem aligns with the tooth inside the injection sleeve.

19
click for next step
DOSATRON INTERNATIONAL, INC. 800-523-8499
REASSEMBLING THE DISPENSER
Dosing assembly

Replace the sleeve O-ring.

20
click for next step
DOSATRON INTERNATIONAL, INC. 800-523-8499
REASSEMBLING THE DISPENSER
Dosing assembly

Insert the metal


retainer.

Thread the adjusting nut


onto the sleeve until it
reaches the top of the
scale.
21
click for next step
DOSATRON INTERNATIONAL, INC. 800-523-8499
REASSEMBLING THE DISPENSER
Dosing assembly

Align teeth on the inside of the anti-friction ring with the 2 grooves in
the dosing stem and slide it up to the adjusting nut.
22
click for next step
DOSATRON INTERNATIONAL, INC. 800-523-8499
REASSEMBLING THE DISPENSER
Dosing assembly

Thread the conical nut onto the dosing


stem. It should be hand tight.

23
click for next step
DOSATRON INTERNATIONAL, INC. 800-523-8499
REASSEMBLING THE DISPENSER
Dosing assembly

Replace and slide the check valve


assembly into the injection stem.
The cone should point out.

24
click for next step
DOSATRON INTERNATIONAL, INC. 800-523-8499
REASSEMBLING THE DISPENSER
Dosing assembly

Remove, replace and Thread the barbed fitting onto


position the check valve seal the injection stem. It should be
into the barbed fitting with the hand tight.
groove facing up. 25
click for next step
DOSATRON INTERNATIONAL, INC. 800-523-8499
REASSEMBLING THE DISPENSER

Remove and replace the plunger Insert the piston straight into
seal by sliding the seal over the end the body all the way down.
of the plunger. 26
click for next step
DOSATRON INTERNATIONAL, INC. 800-523-8499
REASSEMBLING THE DISPENSER

Align the metal retaining


plate with the holes in the
body and install 4 screws.
Carefully align the plunger inside Use #2 Phillips screwdriver.
the injection stem assembly. 27
click for next step
DOSATRON INTERNATIONAL, INC. 800-523-8499
REASSEMBLING THE DISPENSER

Reseat or replace the lid O-ring.


Replace the O-ring if leaking. Screw the lid onto the body of the
dispenser. It should be hand tight.
28
click for next step
DOSATRON INTERNATIONAL, INC. 800-523-8499
REASSEMBLING THE DISPENSER

The dispenser is now


reassembled.

29
click for next step
DOSATRON INTERNATIONAL, INC. 800-523-8499
CHAPTER 4

PISTON MAINTENANCE

D25RE2
0.2 to 2%
1:500 to 1:50

Return to Main Menu


click for next slide
30

DOSATRON INTERNATIONAL, INC. 800-523-8499


PISTON MAINTENANCE
Piston Fit Test

Insert piston into the body half way down, suspend the unit from the valve support ONLY, ONLY
then lift it. The piston should be snug in the body and the body should not fall off, if it does, the
piston shell needs to be replaced. Also inspect the inside of the body and look for deep
vertical scratches, if this is the case, the body needs to be replaced.
Note: Remove plunger seal prior to doing this 31
test so it will not interfere. See page 48. click for next step
DOSATRON INTERNATIONAL, INC. 800-523-8499
PISTON MAINTENANCE
Piston disassembly

Actuate the piston so the piston


valves are in the up position.
Unscrew and remove the valve
support retaining screw.

32
click for next step
DOSATRON INTERNATIONAL, INC. 800-523-8499
PISTON MAINTENANCE
Piston disassembly

Pull the valve support up and slide back to separate it


from the valve.

33
click for next step
DOSATRON INTERNATIONAL, INC. 800-523-8499
PISTON MAINTENANCE
Piston disassembly

On the top of the piston shell, Pull the actuator assembly


unscrew the 4 retaining screws. from under the piston shell.
Use #1 Phillips screwdriver. 34
click for next step
DOSATRON INTERNATIONAL, INC. 800-523-8499
PISTON MAINTENANCE
Piston disassembly: actuator assembly

Remove the 2 springs. When changing


a broken spring, it is best to replace
both springs.

35
click for next step
DOSATRON INTERNATIONAL, INC. 800-523-8499
PISTON MAINTENANCE
Piston disassembly: actuator assembly

Remove the push rod by


sliding it straight down.

36
click for next step
DOSATRON INTERNATIONAL, INC. 800-523-8499
PISTON MAINTENANCE
Piston disassembly: actuator assembly

Remove the plunger. To do this, lift the plunger from the actuator assembly and
pull it towards the outside of its housing. This separates the actuator assembly
entirely. 37
click for next step
DOSATRON INTERNATIONAL, INC. 800-523-8499
PISTON MAINTENANCE
Piston disassembly: actuator assembly

Carefully remove the inlet


valve O-ring, make sure not to
damage the valve.

38
click for next step
DOSATRON INTERNATIONAL, INC. 800-523-8499
PISTON MAINTENANCE

Piston reassembly

Replace the inlet valve O-ring.

39
click for next step
DOSATRON INTERNATIONAL, INC. 800-523-8499
PISTON MAINTENANCE
Piston reassembly

Insert the plunger in the housing of the actuator assembly.

40
click for next step
DOSATRON INTERNATIONAL, INC. 800-523-8499
PISTON MAINTENANCE
Piston reassembly

Inspect the condition of the


push rod and ridge (the
actuator assembly and the
push rod should be
replaced if they show signs
of wear or scoring).

The ridge of the push


rod must be aligned
with the corresponding
groove on the actuator Insert the push rod
assembly. with the long end up.
41
click for next step
DOSATRON INTERNATIONAL, INC. 800-523-8499
PISTON MAINTENANCE
Piston reassembly

Install the 2 actuator springs with


loop opening downward.

42
click for next step
DOSATRON INTERNATIONAL, INC. 800-523-8499
PISTON MAINTENANCE

Piston reassembly

The actuator assembly is now


assembled.

43
click for next step
DOSATRON INTERNATIONAL, INC. 800-523-8499
PISTON MAINTENANCE

Piston reassembly

Inspect the exterior piston shell Inspect o-ring and replace if necessary.
flanges. They should not be worn Align the o-ring in the groove on the
or scored. If they are scored, the bottom of the piston shell.
piston shell should be replaced. 44
click for next step
DOSATRON INTERNATIONAL, INC. 800-523-8499
PISTON MAINTENANCE
Piston reassembly

Position the actuator assembly in the


piston shell.

Align the push rod and valve with the


corresponding holes in the piston shell. 45
click for next step
DOSATRON INTERNATIONAL, INC. 800-523-8499
PISTON MAINTENANCE
Piston reassembly

Push the actuator assembly into the


piston shell and align the screw with
the holes. Install the 4 screws.
Use #2 Phillips screwdriver.

46
click for next step
DOSATRON INTERNATIONAL, INC. 800-523-8499
PISTON MAINTENANCE

Piston reassembly

Align the top inlet valve with the


center groove of the valve support
and push forward until the outlet
valves reach their openings in the
piston shell.

47
click for next step
DOSATRON INTERNATIONAL, INC. 800-523-8499
PISTON MAINTENANCE
Piston reassembly

Position the valve support retainer Replace the plunger seal by


and install screw. sliding the seal over the end
of the plunger. 48
click for next step
DOSATRON INTERNATIONAL, INC. 800-523-8499
PISTON MAINTENANCE
Piston reassembly

The piston is ready to be reinstalled.


49
click for next step
DOSATRON INTERNATIONAL, INC. 800-523-8499
PISTON MAINTENANCE
Reset piston

To reset the piston, remove the lid, push the piston all the way down, it may
click, pull the piston all the way up. Holding it in up position, push down on
the vertical rod and it should click. Push the piston back all the way down
and it should click again. Screw the lid back on.

50
click for next step
DOSATRON INTERNATIONAL, INC. 800-523-8499
CHAPTER 5

AIR BLEED MAINTENANCE

D25RE2
0.2 to 2%
1:500 to 1:50

Return to Main Menu


click for next slide
51

DOSATRON INTERNATIONAL, INC. 800-523-8499


AIR BLEED MAINTENANCE
Air bleed disassembly

Using a small flat blade screwdriver, gently pry loose the rubber cap and
remove it from the top of the air bleed button.
52
click for next step
DOSATRON INTERNATIONAL, INC. 800-523-8499
AIR BLEED MAINTENANCE
Air bleed disassembly

Using a small flat blade Remove the ribbed collar


screwdriver, gently pry by pulling it straight up.
loose the ribbed collar.
53
click for next step
DOSATRON INTERNATIONAL, INC. 800-523-8499
AIR BLEED MAINTENANCE
Air bleed disassembly

Align a 7/8" socket with the Align the two tabs on the air
plastic nut on the underside of bleed with the
corresponding grooves in
the lid and gently twist the air the lid.
bleed turn. 54
click for next step
DOSATRON INTERNATIONAL, INC. 800-523-8499
AIR BLEED MAINTENANCE
Air bleed disassembly

Remove the air bleed button by pushing it through the lid.


55
click for next step
DOSATRON INTERNATIONAL, INC. 800-523-8499
AIR BLEED MAINTENANCE
Air bleed reassembly

Replace the O-ring.


The only serviceable part on
the air bleed is the O-ring.

56
click for next step
DOSATRON INTERNATIONAL, INC. 800-523-8499
AIR BLEED MAINTENANCE
Air bleed reassembly

Position the air bleed Install the air bleed button


button in the socket. from the inside of the cover.
Turn the socket turn to lock the button in the lid.
57
click for next step
DOSATRON INTERNATIONAL, INC. 800-523-8499
AIR BLEED MAINTENANCE
Air bleed reassembly

Install the ribbed collar so that


the slots align with the tabs on
the air bleed button.

58
click for next step
DOSATRON INTERNATIONAL, INC. 800-523-8499
AIR BLEED MAINTENANCE
Air bleed reassembly

Re-install the rubber cap on the air bleed button. Using a small flat
blade screwdriver, gently put back in place the rubber cap.
59
click for next step
DOSATRON INTERNATIONAL, INC. 800-523-8499
CHAPTER 6

BY-PASS MAINTENANCE

D25RE2
0.2 to 2%
1:500 to 1:50

Return to Main Menu


click for next slide
60

DOSATRON INTERNATIONAL, INC. 800-523-8499


BY-PASS MAINTENANCE

By-pass disassembling

Set the by-pass button to ON. Use needle nose pliers or awl to
push pin out.
61
click for next step
DOSATRON INTERNATIONAL, INC. 800-523-8499
BY-PASS MAINTENANCE

By-pass disassembling

Remove the pin from the Remove the "ON-OFF" knob by


"ON-OFF" knob and the firmly snapping it out of the
stainless steel stem of the collar.
by-pass.
62
click for next step
DOSATRON INTERNATIONAL, INC. 800-523-8499
BY-PASS MAINTENANCE

By-pass disassembling

Using a small flat blade screwdriver,


gently pry loose the ribbed collar.

Remove the ribbed collar by lifting it


straight up.

63
click for next step
DOSATRON INTERNATIONAL, INC. 800-523-8499
BY-PASS MAINTENANCE

By-pass disassembling

Align a 7/8" socket with the plastic nut


on the underside of the lid and gently
twist the by-pass turn.

Align the two tabs on the by-pass with


the corresponding grooves in the lid.

64
click for next step
DOSATRON INTERNATIONAL, INC. 800-523-8499
BY-PASS MAINTENANCE

By-pass disassembling

Remove the by-pass by pushing it


through the lid.

The O-ring is the only serviceable


part on the by-pass.

65
click for next step
DOSATRON INTERNATIONAL, INC. 800-523-8499
BY-PASS MAINTENANCE
By-pass reassembling

Slide the stainless steel Install the by-pass from the inside of the lid.
stem into the by-pass. With the socket, turn the by-pass turn to
lock it in the lid.
66
click for next step
DOSATRON INTERNATIONAL, INC. 800-523-8499
BY-PASS MAINTENANCE
By-pass reassembling

Install the ribbed collar so that the slots


align with the tabs on the bypass.

67
click for next step
DOSATRON INTERNATIONAL, INC. 800-523-8499
BY-PASS MAINTENANCE
By-pass reassembling

Carefully position by-pass Lightly tap on the top of the knob


knob in the collar. with a mallet to snap it in place.
68
click for next step
DOSATRON INTERNATIONAL, INC. 800-523-8499
BY-PASS MAINTENANCE
By-pass reassembling

With the lever in the "ON" Install the pin. When completed,
position, align the holes of the the pin should not protrude on
lever and stainless rod of the either side of the lever.
by-pass. 69
click for next step
DOSATRON INTERNATIONAL, INC. 800-523-8499
CHAPTER 7

TROUBLESHOOTING GUIDE

D25RE2
0.2 to 2%
1:500 to 1:50

Return to Main Menu


click for next slide
70

DOSATRON INTERNATIONAL, INC. 800-523-8499


TROUBLESHOOTING GUIDE

SYMPTOM CAUSE REMEDY


PISTON The unit is installed in the wrong The arrow on the unit should point in the same direction
Piston is not clicking direction as the water flow. Water supply and demand valves
should be open.
Piston locked up/not clicking Reset piston. See page 50 for instructions.
Broken actuator spring Replaced both actuator springs.

Excessive water flow 1. Reduce the flow rate and slowly restart the unit.
2. Remove the lid, pull out the piston and check if the O-
rings around the piston valves are missing or dislodged.
3. Reset piston (see page 50 for instructions) screw lid
back on.
Water hammer Reset piston (see page 50 for instructions) and install
water hammer arrestor in the appropriate location.
In line water filter is clogged Clean the water filter.
Worn, scratched/scored piston Do piston fit test (page 31). Replace piston shell and/or
shell and body body. Make sure installation has a 200 mesh filter before
the Dosatron.
DOSING Check valve dirty, worn, Clean or replace the check valve assembly. Pages 24 &
Water flowing back into assembled incorrectly or missing 25.
solution container

71
click for next step
DOSATRON INTERNATIONAL, INC. 800-523-8499
TROUBLESHOOTING GUIDE

SYMPTOM CAUSE REMEDY


No suction of solution Piston locked up/not clicking Reset piston. See page 50 for instructions.
Air leak in the suction tube Check suction tube connection. Inspect suction
tube for pin holes or cracks. Check tightness of
connection nuts.
Cut inch off the top of the hose and reattach it
correctly.
Suction tube or strainer clogged Clean suction tube and strainer or replace hose
assembly.
Raise strainer 2 inches off the bottom of stock
solution container.
Check valve worn, improperly Clean or replace check valve assembly. Pages
assembled, dirty or damaged 24 & 25.
Plunger seal is damaged, swollen or Clean or replace plunger seal. If plunger seal is
missing missing, check incoming water pressure; refer to
unit manual for specifications.
Worn piston shell and/or body Do piston fit test (page 31). If necessary
replace piston shell and/or body. Make sure your
installation has a 200 mesh filter before the
Dosatron.
72
click for next step
DOSATRON INTERNATIONAL, INC. 800-523-8499
TROUBLESHOOTING GUIDE

SYMPTOM CAUSE REMEDY


Under-Injection Worn or scratched piston shell Do piston fit test (page 31). If necessary replace
and/or body piston shell and/or body. Make sure the
installation has a 200 mesh filter before the
dispenser.
Suction of air Check suction tube connection. Inspect suction
tube for pin holes or cracks. Check tightness of
connection nuts.
Cut inch off the top of the hose and reattached
it correctly.
Excessive water flow Listen to the unit clicking, count the individual
clicks, should not exceed 46 in 15 seconds
otherwise is excessive flow. If excessive flow
reduce the flow rate and restart the unit slowly.
Worn plunger seal Replace plunger seal.

Worn or cracked injection stem Replace injection stem.


(inside or outside).
Check valve worn, improperly Clean or replace check valve assembly. Pages 24
assembled, dirty or damaged & 25.
73
click for next step
DOSATRON INTERNATIONAL, INC. 800-523-8499
TROUBLESHOOTING GUIDE

SYMPTOM CAUSE REMEDY


LEAKS Sleeve O-ring damaged, Replace sleeve O-ring.
Leaks near the metal collar under the improperly positioned or
body. missing
Leaks between adjusting nut and the anti- Injection stem O-ring Clean and replace injection stem O-ring.
lock ring. damaged, improperly
positioned or missing

Leaks between body and lid. Lid O-ring damaged, Position O-ring correctly, clean the seating
improperly positioned or surface of the O-ring or replace the lid O-ring.
missing

74
click for next step
DOSATRON INTERNATIONAL, INC. 800-523-8499
Thank you for using Dosatron liquid dispensers.

Please contact us at (800) 523-8499 for further


assistance or visit our website at
www.dosatronUSA.com

2090 Sunnydale Blvd., Clearwater, Florida 33765

75
click for next step
DOSATRON INTERNATIONAL, INC. 800-523-8499