Control of Deflections :
Minimum Thicknesses
Initial Camber
=
1 + 500
Time Factor for Sustained Loads
(SNI/ACI Code 9.5.2.5)
Duration of Load Time Factor
5 years or more 2.0
12 months 1.4
6 months 1.2
3 months 1.0
In the SNI/ACI Code, Sections 10.6.3 and 10.6.4 require that flexural
tensile reinforcement be well distributed within the zones of
maximum tension so that the center-to-center spacing of the
reinforcing closest to a tension surface is not greater than the value
computed with the following expression:
280 280
s = 380 2.5cc 300
fs fs
The term cc represents the clear cover from the nearest surface in
tension to the surface of the tensile reinforcement.
For beam with fy = 400 MPa, and clear decking 40 mm, maximum bar
spacing is: !
280
s = 380 2 2.5 40 = 215mm