Field Acceptance Protocol

Field Acceptance Protocol Nokia Siemens Networks 1 (86)


The information in this document is subject to change without notice and describes only the product defined in the
introduction of this documentation. This document is intended for the use of Nokia Siemens Networks customers only for
the purposes of the agreement under which the document is submitted, and no part of it may be used, reproduced,
modified or transmitted in any form or means without the prior written permission of Nokia Siemens Networks. The
document has been prepared to be used by professional and properly trained personnel, and the customer assumes full
responsibility when using it. Nokia Siemens Networks welcomes customer comments as part of the process of
continuous development and improvement of the documentation.
The information or statements given in this document concerning the suitability, capacity, or performance of the
mentioned hardware or software products are given as is and all liability arising in connection with such hardware or
software products shall be defined conclusively in a separate agreement between Nokia Siemens Networks and the
customer. However, Nokia Siemens Networks has made all reasonable efforts to ensure that the instructions contained
in the document are adequate and free of material errors and omissions. Nokia Siemens Networks will, if deemed
necessary by Nokia Siemens Networks, explain issues which may not be covered by the document.
Nokia Siemens Networks will correct errors in the document as soon as possible. IN NO EVENT WILL NOKIA SIEMENS
NETWORKS BE LIABLE FOR ERRORS IN THIS DOCUMENT OR FOR ANY DAMAGES, INCLUDING BUT NOT
LIMITED TO SPECIAL, DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL OR ANY MONETARY
LOSSES,SUCH AS BUT NOT LIMITED TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS
OPPORTUNITY OR DATA,THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR THE INFORMATION IN IT
This document and the product it describes are considered protected by copyrights and other intellectual property rights
according to the applicable laws.
Wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark of Nokia Corporation.
Siemens is a registered trademark of Siemens AG.
Other product names mentioned in this document may be trademarks of their respective owners, and they are
mentioned for identification purposes only.
Copyright Nokia Siemens Networks 2008. All rights reserved.

Field Acceptance Protocol Nokia Siemens Networks 2 (86)


Content
Field Acceptance Protocol................................................................................................1
Abbreviations.........................................................................................................................3
Requirements .........................................................................................................................3
Test of Battery Voltage ..........................................................................................................3
Communication Q-F Interface ................................................................................................3
Communication Q-B3 Interface..............................................................................................3
Function Test of Service Channels (AUX)..............................................................................3
Function test of TIF-interface .................................................................................................3
Function Test of EOW ...........................................................................................................3
Bit Error Test on Line Side (12h, STM-1 trib) ........................................................................3
Computer Equipment .............................................................................................................3
Provisional Acceptance Sheet (Network)................................................................................3
IFO155M STM-1 Optical Mean Launched Power via ODF ................................................3
IFO155M STM-1 Optical Receive Power...........................................................................3
IFQ622M STM-4 Optical Mean Launched Power via ODF ................................................3
IFQ622M STM-4 Optical Receive Power...........................................................................3
IFS2G5 STM-16 Optical Mean Launched Power via ODF .................................................3
IFS2G5 STM-16 Optical Receive Power ............................................................................3
IFS2G5B STM-16 Optical Mean Launched Power via ODF...............................................3
IFS2G5B STM-16 Optical Receive Power..........................................................................3
IFQ2G5 STM-16 Optical Mean Launched Power via ODF.................................................3
IFQ2G5B STM-16 Optical Mean Launched Power via ODF ..............................................3
IFQ2G5 STM-16 Optical Receive Power............................................................................3
IFQ2G5B STM-16 Optical Receive Power .........................................................................3
IFS10G STM-64 Optical Mean Launched Power via ODF .................................................3
IFS10G STM-64 Optical Receive Power ............................................................................3
IFS10GB STM-64 Optical Mean Launched Power via ODF...............................................3
IFS10GB STM-64 Optical Receive Power..........................................................................3
IFS10G-WLS STM-64 Optical Mean Launched Power via ODF ........................................3
IFS10G-WLS STM-64 Optical Receive Power...................................................................3
IFS10G-M STM-64 Optical Mean Launched Power via ODF.............................................3
IFS10G-M STM-64 Optical Receive Power .......................................................................3
IFS10G-R STM-64 Optical Mean Launched Power via ODF..............................................3
IFS10G-R STM-64 Optical Receive Power ........................................................................3
IFS10G-R STM-64 Optical Mean Launched Power via ODF..............................................3
IFS10G-R STM-64 Optical Receive Power ........................................................................3
IFS40G-MX STM-256 Optical Mean Launched Power via ODF ........................................3
IFS40G-MX STM-256 Optical Receive Power...................................................................3
IFOFE-E Throughput, Latency and Frame Loss (RFC2544) Test .......................................3
IFOFE Throughput, Latency and Frame Loss (RFC2544) Test ...........................................3
IFQGBE Throughput, Latency and Frame Loss (RFC2544) Test........................................3
IFQGBEB Throughput, Latency and Frame Loss (RFC2544) Test .....................................3
IFQGBE-E Throughput, Latency and Frame Loss (RFC2544) Test ....................................3
IFQGBEB-E Throughput, Latency and Frame Loss (RFC2544) Test..................................3
IFOFES-E Throughput, Latency and Frameloss (RFC2544) Test........................................3
IF2M Cabling Test ............................................................................................................3
IF345M Cabling Test .........................................................................................................3
IFO155M-E - STM-1 Cabling test ......................................................................................3
PF2G5B IEEE 802.3 & RFC2544 Error Test......................................................................3
IF7FE2GEL2 Throughput, Latency and Frame Loss (RFC2544) Test.................................3
IF4FE4GE Throughput, Latency and Frame Loss (RFC2544) Test.....................................3
IFS10GBE Throughput, Latency and Frame Loss (RFC2544) Test.....................................3

Field Acceptance Protocol Nokia Siemens Networks 3 (86)


Summary of changes

Re-issue date Reason Modified by Version


2007.08.10 B550 version 01
2008.01.28 First Issue for B600 02
2008.01.31 Update of NE APS 03
2008.07.15 Update for R 3.4 B600

Abbreviations
APS Application Software
AUX Auxiliary Channel
CLU Clock Unit Interface
CP Card Protection
DC Double Core (Double-Row Subrack)
DCC Data Communication Channel
DCCM DCC Bytes D4 to D12 (Multiplex Section)
DCCR DCC Bytes D1 to D3 (Regenerator Section)
DCN Data Communication Network
DDF Digital Distributor Frame
ETH Ethernet
FW Firmware
G.703 Physical/Electrical characteristics of hierarchical digital interfaces
IEEE 802.3 Carrier Sense Multiple Access with Collision Detection (CSMA/CD) Access Method &
Physical Layer Specifications
IF2M Electrical Interface card for 2Mbits/s 63 Ports
IF345M Electrical Interface card for 34/45Mbits/s 3xDS3/E3 Ports
IFO155M Optical Interface card STM-1 8 Ports
IFOFE-E Electrical Fast Ethernet card 8 Ports
IFOFE Optical Fast Ethernet card 8 Ports
IFQ2G5 Optical Interface card STM-16 4 Ports
IFQ622M Optical Interface card STM-4 4 Ports
IFQGBE Optical Gigabit Ethernet card 4 Ports
IFQGBE-E Electrical Gigabit Ethernet card 4 Ports
IFS10GBE Electrical Gigabit Ethernet card 1 Ports
IFQGBEB Optical Gigabit Ethernet card 4 Ports
IFS10G Optical STM-64 card 1 Port
IFS10GB Optical STM-64 card 1 Port
IFS10GB Optical STM-64 card 1 Port WDM
FS10G-M Optical Coloured STM-64 card for Metro WDM 1 Port
IFS2G5 Optical Interface card STM-16 1 Port
IFS2G5B Optical Interface card STM-16 1 Port
IFS40G-MX Optical Mux/Demux for 40G Interface (input: 4x10G; output: 1x40G)
I FSOA Interface Single Optical Amplifier
I FSOA-PDC Interface Single Optical Amplifier with Passive Dispersion Compensation
I FSOB Interface Single Optical Booster
I FSOB-PDC Interface Single Optical Booster with Passive Dispersion Compensation
TU-T International Telecommunication Union Telecom
LAN Local Area Network
LCT Local Craft Terminal
LOS Loss of Signal
LSU Line Switching Unit (card) for 2 MBit/s ports
MAC Media Access Control
NCT Network Craft Terminal
NE Network Element
OBD Optical Booster Device (card)
ODF Optical Distributor Frame
OHX Overhead Crossconnection Function
OSI Open System Interconnection
PC Personal Computer
PDH Plesiochronous Digital Hierarchy
PF2G5 Packet Switch Fabric Card
Q-B3 Standardized Q interface
Q-F Operating Terminal Interface
RFC 2544 Benchmarking Methodology for Network Interconnect Devices
RPR Resilient Packet Ring
SC Single Core (Single-Row Subrack)

Field Acceptance Protocol Nokia Siemens Networks 4 (86)


SCOH Subrack Controller and Overhead Card
SDH Synchronous Digital Hierarchy
SF160G Switching Fabric (Central VC-4 switch card)
SF2G5 Switching Fabric (Low order VC-3/VC-12 switch card)
SFP Small Form-factor Pluggable (Optical modules)
SRAP Subrack Alarm Panel
STM Synchronous Transport Module (level 1, 4, 16)
SW Software
TRIB Tributary
UBAT Battery Voltage
V.11 Physical / Electrical interface characteristics
VC Virtual Container
WDM Wavelength Division Multiplexing
ZA Disturbance Alarm
ZA(A) High-Priority Alarm
ZA(B) Low-Priority Alarm

Field Acceptance Protocol Nokia Siemens Networks 5 (86)


Requirements
Equipment Type Recommendation

Bit error test set SDH/PDH-test set Optional: ANT-20 with STM-
16 interface
Ethernet test set IEEE802.3 & RFC2544 Agilent J2127A; GN Nettest
CMA5000; EXFO FTB8510-2
Digital analyser for slow bit
rates
(only if AUX channels are used)
Optical test equipment Power meter
10 dB optical attenuators
Cleaning material Isopropanol 99%
Fibre cables According to the delivered
cards
Multimeter/Voltmeter Range 0..1000V
Accuracy +/- 5%
ESD wristband

Write down type and serial number of each measuring device used by this protocol.

Equipment Model Type Serial-Number

Bit error test set


Power meter
Optical fiber scope
Multimeter
Ethernet test set

Inventory List
Station:

_____________________________________________

Historical Data:

Commissioning Date: Commissioner:

______________________________ _______________________________

Field Acceptance Protocol Nokia Siemens Networks 6 (86)


Test of Battery Voltage
Description: This test gives the Steps required to check the battery cabling of the NE.
The following item will be tested.

1. Voltage and correct polarity of the battery

Test equipment: Multimeter (Voltmeter)

Tested position:__________________

Step Procedure Expected Result Result Comply


(Y/N)
1 Test voltage and correct polarity (+/-) of Values should be within the range UBAT 1 -
connected battery voltage -40.5V to -75.0V UBAT 2 -
UBAT 3 -
UBAT 4 -

Field Acceptance Protocol Nokia Siemens Networks 7 (86)


Communication Q-F Interface
Description: This test gives the procedure to verify the NE communication interface
with LCT via the QF interface.

Test equipment: Local Craft Terminal LCT

Tested position:____________________

Step Procedure Expected Result Result Comply


(Y/N)
1 Configure NE and LCT as in Figure below
2 LCT login to NE
3 Do some configurations from LCT - NE can operate via LCT

PC/Laptop computer

Q-F
Q-F

NE

Field Acceptance Protocol Nokia Siemens Networks 8 (86)


Communication Q-B3 Interface
(Test is only necessary if Q-B3 is used)

Description: This test gives the procedure to verify the NE communication interface
with LTC/NTC via QB3 and within network via DCC

Test equipment: LTC/NTC with Ethernet connection

Remote stations:__________________

Step Procedure Expected Result Result Comply


(Y/N)
1 Configure LCT/NCT for QB3. Connect
LCT/NCT and NE as in Figure below via
Ethernet.
2 LCT/NCT login to local NE - Login is successful
3 Do some configurations from LCT/NCT - NE can operate via LCT
4 LCT/NCT login to remote NE - Login is successful
5 Do some configurations from LCT - NE can operate via LCT

Ethernet

DCCM/DCCR DCCM/DCCR
NE

PC/Laptop computer

NE NE

NE
DCCM/DCCR DCCM/DCCR

Field Acceptance Protocol Nokia Siemens Networks 9 (86)


Function Test of Service Channels (AUX)

Description: This test gives the steps required the test the AUX-channels of the NE.
The following item will be tested:

1. Function test of Service channels (AUX)

Test equipment: Digital analyzer for slow bit rates, Multimeter, LTC/NTC

Tested position:________________

Remark: This test is only done as field test if the AUX channels are connected to a
distributor.

Mark the tested AUX type:

V.11 used: asynchronous


used: synchronous

G.703

Bitrate of AUX channel:__________________

Step Procedure Expected Result Result Comply


(Y/N)
1 If necessary perform desired cross-
connection from AUX-port to any SDH-port or
line and loop the SDH-port with an external
loop.
2 When testing V.11 channels in synchronous
mode then connect in transmit direction
data and clock. In receive direction only
data should be connected.

3 When testing V.11 in asynchronous mode or


G.703 only data connections are used
4 Analyzer setup:
1. Choose the appropriate interface-setting.
When testing V.11 in synchronous mode set
clock to external. In all other cases set it to
internal.
5 Test the AUX channel with a PRBS11 -no bit errors and slips
6 Test the AUX channel with a pattern 0101 -no bit errors and slips

Field Acceptance Protocol Nokia Siemens Networks 10 (86)


Clock Data Data
in out in
DDF

a b a b a b a b a b a b a b

Data Clock Data Data Data Data Data


out out in out in + +
clock clock

V. 11 Interface V. 11 Interface G. 703


synchronous asynchronous codirectional

10 dB
L L
T
i i
n n
e e
any SDH
Trib NE
(alternatively)

10 dB

Field Acceptance Protocol Nokia Siemens Networks 11 (86)


Function test of TIF-interface
Description: This test gives the steps required to test the TIF-contacts of the NE. The
following item will be tested:

Test equipment: Multimeter, power-supply and LTC/NTC.

Tested position:________________

Remark: This test is only done, if TIF-contacts are connected to a distributor (external equipment).

Step Procedure Expected Result Result Comply


(Y/N)
1 Configure contacts (input, output) as
required.
2 Check with test-equipment values on according specification
distributor.
3 Additionally check alarms with LCT/NCT in according settings
function group OHX

Field Acceptance Protocol Nokia Siemens Networks 12 (86)


Function Test of EOW

Description: This test gives the steps required to test the EOW function.

Test equipment: LCT/NCT

Tested position: _____________

Step Procedure Expected Result Result Comply


(Y/N)
1 Enter in every NE a unique EOW-telephone
number (three digits).
2 Perform an OH-cross-connection from E1 or
E2 Byte of the desired line- /trib side to
conference-bus. Do this at all concerned
NEs in the line/ring.
3 Test calling and speaking. Calling and speaking is possible.
Every handset in the line can be
connected to the conference-bus
by pressing # on the handset.

4 If using a ring configuration the E1/E2 byte of Calling and speaking is possible.
one line/trib side in the ring has to be cross- Every handset in the line can be
connected to RM (ring manager) instead of connected to the conference-bus
conference Example of a network see by pressing # on the handset.
figure below
5 Mark settings in table 1

Field Acceptance Protocol Nokia Siemens Networks 13 (86)


Network example with EOW function:

RM Conf Conf Conf


E1 (e.g)
L L L L
i NE 1 i i i
NE 2
n n n n
e e e e

west east west east

Conf NE 3 Conf
E2 (e.g) any E1 (e.g)
L STM L
i Trib. i
n n

G. 703
e

Conf
e
west east

Conf

E1/E2 byte transmission L any L


i STM i
via AUX channel G. 703 Trib.
n n
e e
NE 4

figure

Table of EOW settings:

Trib/Line-position RM Conference E1 E2 G.703

Table 1 (mark the appropriate settings)

Field Acceptance Protocol Nokia Siemens Networks 14 (86)


Bit Error Test on Line Side (12h, STM-1 trib)
Description: This test gives the steps required to measure the line between two
terminal NEs. The following item will be tested:

1. Bit error measurement of line side (12hours, measured via STM-1)

Test equipment: SDH-analyzer

Tested Remote station:_____________________

Step Procedure Expected Result Result Comply


(Y/N)
1 Configure NE with an appropriate STM-1
interface and a cross-connection to the
Line side.
2 Loop the appropriate VC-4 at the remote
station in any kind. A chain of more than
one Multiplex-section in line- or ring
configuration is possible.

3 Do a bit error-measurement with the SDH < 10-10 bit errors


analyzer at the distributor and perform a
bit error-measurement with an injected
payload of 140MBit/s during 12h
(PRBS23)

4 If line protection is used, repeat step 3 for <10-10 bit errors


protection

Experimental arrangement

PC/Laptop computer

QB 3
Remote Station
NE NE

L L L L
i i i SF160G Station i
Local Station
SF160G
n
Remote n
n n
e e e e

STM- 1
STM- 1

DDF

SDH Analyzer

Field Acceptance Protocol Nokia Siemens Networks 15 (86)


Computer Equipment

PC Type, Fabrication# ________________________________________

Monitor Type, Fabrication# ________________________________________

Mouse Type, Fabrication# ________________________________________

Printer Type, Fabrication# ________________________________________

Windows Version: ________________________________________

NCT/LCT Software Version: ________________________________________

Osi-Stack Version: ________________________________________

Provisional Acceptance Sheet (Network)

Item Remark Open Comply


(Y/N)

Delivery complete
Documentation complete
Computer Equipment
Test cases
SW Database

Field Acceptance Protocol Nokia Siemens Networks 16 (86)


IFO155M STM-1 Optical Mean Launched Power via ODF
Description: This test gives the steps required to measure the STM-1 optical interface
of the NE. The following item will be tested:

Optical output power of laser

Test equipment: Optical power meter, LTC/NTC

STM-1 interfaces:
Type No. ITU SFP-Modul Order Line Launched Power
Number

1. Short-haul version 1310nm S-1.1 V50017-U323-K500 -15 dBm to -8 dBm


2. Long-haul version 1310nm L-1.1 V50017-U324-K500 -5 dBm to 0 dBm
3. Long-haul version 1550nm L-1.2/3 V50017-U325-K500 -5 dBm to 0 dBm

Tested position:________________

Step Procedure Expected Result Result Comply


(Y/N)
Connect STM-1 optical output to an optical
1 power meter (see Experimental
arrangement)
Force the laser to start Values should be within the limits
according the following rule:
(Measured value) + (connector
2 loss) = ITU table above.
Connector loss: 0,6 1dB per
connector

Record value of optical transmit power Look at STM1 Interface table


3.1 and enter :
Type No. / Port 1
3.2 --II-----II-- Type No. / Port 2
3.3 --II-----II-- Type No. / Port 3
3.4 --II-----II-- Type No. / Port 4
3.5 --II-----II-- Type No. / Port 5
3.6 --II-----II-- Type No. / Port 6
3.7 --II-----II-- Type No. / Port 7
3.8 --II-----II-- Type No. / Port 8

Field Acceptance Protocol Nokia Siemens Networks 17 (86)


Experimental arrangement

PC/Laptop computer

Q- F/ QB 3

L L
SF2G5/SF160G
i i
n n
e e

IFO155M NE

ODF

Power Meter

Field Acceptance Protocol Nokia Siemens Networks 18 (86)


IFO155M STM-1 Optical Receive Power
Description: This test gives the step required to measure the STM-1 optical interface
of the NE. The following item will be tested:

Optical receive power of laser

Test equipment: Optical power meter, LCT/NCT

STM-1 interfaces:
Type No. ITU SFP-Module Line Receive Power
Order Number

1. Short-haul version 1310nm S-1.1 V50017-U323-K500 -28 dBm to -8 dBm


2. Long-haul version 1310nm L-1.1 V50017-U324-K500 -34 dBm to -10 dBm
3. Long-haul version 1550nm L-1.2/3 V50017-U325-K500 -34 dBm to -10 dBm

Tested position:____________ Remote station:__________________

Step Procedure Expected Result Result Comply


(Y/N)
Connect STM-1 optical output to an optical
1 power meter (see Experimental
arrangement)
Force the laser to start Values should be within the limits
according the following rule:
(Measured value) + (connector
2 loss) = ITU table above.
Connector loss: 0,6 1dB per
connector

Record value of optical transmit power Look at STM1 Interface table


3.1 and enter :
Type No. / Port 1
3.2 --II-----II-- Type No. / Port 2
3.3 --II-----II-- Type No. / Port 3
3.4 --II-----II-- Type No. / Port 4
3.5 --II-----II-- Type No. / Port 5
3.6 --II-----II-- Type No. / Port 6
3.7 --II-----II-- Type No. / Port 7
3.8 --II-----II-- Type No. / Port 8

Field Acceptance Protocol Nokia Siemens Networks 19 (86)


Experimental arrangement

PC/Laptop computer

QB 3

NE 1 NE 2
ODF
L L L L
i i i i
Local Station STM-1 Remote Station
n n n n
e e e e

Power Meter

Field Acceptance Protocol Nokia Siemens Networks 20 (86)


IFQ622M STM-4 Optical Mean Launched Power via ODF
Description: This test gives the steps required to measure the STM-4 optical interface
of the NE. The following item will be tested:

Optical output power of laser

Test equipment: Optical power meter, LCT/NCT

STM-4 interfaces:
Type No. ITU SFP-Module Line Launched Power
Order Number
1. Short-haul version 1310nm S-4.1 V50017-U330-K500 -15 dBm to 8 dBm
2. Long-haul version 1310nm L-4.1 V50017-U331-K500 -3 dBm to +2 dBm
3. Long-haul version 1550nm L-4.2/3 V50017-U332-K500 -3 dBm to +2 dBm
4. Very-long-haul version V-4.2/3 V50017-U333-K500 0 dBm to +4 dBm
1550nm

Tested position:__________________

Step Procedure Expected Result Result Comply


(Y/N)
Connect STM-4 optical output to an optical
1 power meter (see Experimental
arrangement)
Force the laser to start Values should be within the limits
according the following rule:
(Measured value) + (connector
2 loss) = ITU table above.
Connector loss: 0,6 1dB per
connector

Record value of optical transmit power Look at STM4 Interface table


3.1 and enter :
Type No. / Port 1
3.2 --II-----II-- Type No. / Port 2
3.3 --II-----II-- Type No. / Port 3
3.4 --II-----II-- Type No. / Port 4

Field Acceptance Protocol Nokia Siemens Networks 21 (86)


Experimental arrangement

PC/Laptop computer

Q- F/ QB 3

L L
SF2G5/SF160G
i i
n n
e e

IFQ622M NE

ODF

Power Meter

Field Acceptance Protocol Nokia Siemens Networks 22 (86)


IFQ622M STM-4 Optical Receive Power
Description: This test gives the step required to measure the STM-4 optical interface of
the NE. The following item will be tested:

Optical receive power of laser

Test equipment: Optical power meter, LCT/NCT

STM-4 interfaces:
Type No. ITU SFP-Module Line Receive Power
Order Number
1. Short-haul version 1310nm S-4.1 V50017-U330-K500 -28 dBm to -8 dBm
2. Long-haul version 1310nm L-4.1 V50017-U331-K500 -28 dBm to -8 dBm
3. Long-haul version 1550nm L-4.2/3 V50017-U332-K500 -28 dBm to -8 dBm
4. Very-long-haul version 1550nm V-4.2/3 V50017-U333-K500 -34 dBm to -18 dBm

Tested position:____________ Remote station:__________________

Step Procedure Expected Result Result Comply


(Y/N)
Connect the NE via STM-4 line with the no LOS alarm at appropriate
1 remote station. (see Experimental function unit
arrangement)
Disconnect the optical fibre at the local
2 station and connect it with the optical power
meter
Start the laser Measure the optical receive
power. Look at STM4 Interface
3.1 table and enter :

Type No. / Port 1


3.2 --II-----II-- Type No. / Port 2
3.3 --II-----II-- Type No. / Port 3
3.4 --II-----II-- Type No. / Port 4

Field Acceptance Protocol Nokia Siemens Networks 23 (86)


Experimental arrangement

PC/Laptop computer

QB 3

NE 1 NE 2
ODF
L L L L
i i i i
Local Station STM-4 Remote Station
n n n n
e e e e

Power Meter

Field Acceptance Protocol Nokia Siemens Networks 24 (86)


IFS2G5 STM-16 Optical Mean Launched Power via ODF
Description: This test gives the steps required to measure the STM-16 optical
interface of the NE. The following item will be tested:

Optical output power of laser

PC/Laptop computer

Q- F/ QB 3

L L
SF2G5/SF160G
i i
n n
e e
NE

IFS2G5 IFSOA

ODF

Power Meter

Test equipment: Optical power meter, LCT/NCT

STM-16 interfaces:
Type No. ITU Ordering number Line launch power

1. Short-haul version 1310nm S-16.1 S42024-L5210-A100 -5 dBm to 0 dBm


2. Long-haul version 1550nm JE (33dB)V16.2/3 S42024-L5210-A400 6 dBm to 10dBm
3. Very long-haul version JE (47dB)U16.2/3 S42024-L5210-D437 10 dBm to 13dBm
1550nm S42024-L5263-A100

Tested position:_________________
Step Procedure Expected Result Result Comply
(Y/N)
Connect STM-16 optical output to an optical
1 power meter (see Experimental

Field Acceptance Protocol Nokia Siemens Networks 25 (86)


arrangement)

Force the laser to start Values should be within the limits


according the following rule:
(Measured value) + (connector
2 loss) = ITU table above.
Connector loss: 0,6 1dB per
connector

Record value of optical transmit power Look at STM16 Interface table


3 and enter :
Type No. / Port 1

Experimental arrangement

Field Acceptance Protocol Nokia Siemens Networks 26 (86)


IFS2G5 STM-16 Optical Receive Power
Description: This test gives the step required to measure the STM-16 optical interface
of the NE. The following item will be tested:

Optical receive power of laser

Test equipment: Optical power meter, LCT/NCT

STM-16 interfaces:
Type No. ITU Ordering number Line Receive Power

1. Short-haul version 1310nm S-16.1 S42024-L5210-A100 -18 dBm to 0 dBm


2. Long-haul version 1550nm JE (33db)V16.2/3 S42024-L5210-A400 -9 dBm to -29 dBm
2. Very long-haul version JE (47db)V16.2/3 S42024-L5210-D437 -15dBm to -39 dBm
1550nm S42024-L5263-A100

Tested position:____________ Remote station:__________________

Step Procedure Expected Result Result Comply


(Y/N)
Connect the NE via STM-16 line with the no LOS alarm at appropriate
1 remote station. (see Experimental function unit
arrangement)
Disconnect the optical fibre at the local
2 station and connect it with the optical power
meter
Start the laser Measure the optical receive
power. Look at STM16 Interface
3 table and enter :

Type No. / Port 1

Field Acceptance Protocol Nokia Siemens Networks 27 (86)


Experimental arrangement

PC/Laptop computer

QB 3

NE 1 NE 2
ODF
L L L L
i i i i
Local Station STM-16 Remote Station
n n n n
e e e e

Power Meter

Field Acceptance Protocol Nokia Siemens Networks 28 (86)


IFS2G5B STM-16 Optical Mean Launched Power via ODF
Description: This test gives the steps required to measure the STM-16 optical
interface of the NE. The following item will be tested:

Optical output power of laser

Test equipment: Optical power meter, LCT/NCT

STM-16 interfaces:
Type No. ITU Ordering number Line launch power

1. Short-haul version 1310nm S-16.1 V50017-U340-K550 -5 dBm to 0 dBm


2. Intra-office version 1310nm I-16.1 V50017-U343-K550 -10 dBm to -3 dBm
3. Long-haul version 1310nm L16.1 V50017-U341-K550 -2 dBm to 3 dBm
4. Long-haul version 1550nm L16.2/3 V50017-U342-K550 -2 dBm to 3 dBm

Tested position:_________________

Step Procedure Expected Result Result Comply


(Y/N)
Connect STM-16 optical output to an optical
1 power meter (see Experimental
arrangement)
Force the laser to start Values should be within the limits
according the following rule:
(Measured value) + (connector
2 loss) = ITU table above.
Connector loss: 0,6 1dB per
connector

Record value of optical transmit power Look at STM16 Interface table


3 and enter :
Type No. / Port 1

Field Acceptance Protocol Nokia Siemens Networks 29 (86)


Experimental arrangement

PC/Laptop computer

Q- F/ QB 3

L L
SF2G5/SF160G
i i
n n
e e

IFS2G5 NE

ODF

Power Meter

Field Acceptance Protocol Nokia Siemens Networks 30 (86)


IFS2G5B STM-16 Optical Receive Power
Description: This test gives the step required to measure the STM-16 optical interface
of the NE. The following item will be tested:

Optical receive power of laser

Test equipment: Optical power meter, LCT/NCT

STM-16 interfaces:
Type No. ITU Ordering number Line launch power

1. Short-haul version 1310nm S-16.1 V50017-U340-K550 -18 dBm to 0 dBm


2. Intra-office version 1310nm I-16.1 V50017-U343-K550 -18 dBm to -3 dBm
3. Long-haul version 1310nm L16.1 V50017-U341-K550 -27 dBm to -9 dBm
4. Long-haul version 1550nm L16.2/3 V50017-U342-K550 -28 dBm to -9 dBm

Tested position:____________ Remote station:__________________

Step Procedure Expected Result Result Comply


(Y/N)
Connect the NE via STM-16 line with the no LOS alarm at appropriate
1 remote station. (see Experimental function unit
arrangement)
Disconnect the optical fibre at the local
2 station and connect it with the optical power
meter
Start the laser Measure the optical receive
power. Look at STM16 Interface
3 table and enter :

Type No. / Port 1

Field Acceptance Protocol Nokia Siemens Networks 31 (86)


IFQ2G5 STM-16 Optical Mean Launched Power via ODF
Description: This test gives the steps required to measure the STM-16 optical interface
of the NE. The following item will be tested:

Optical output power of laser

Test equipment: Optical power meter, LCT/NCT

STM-16 interfaces:
Type No. ITU SFP-Module Line launch power
Order Number

1. Intra-office version 1310nm I-16.1 V50017-U343-K500 -10 dBm to -3 dBm


2. Short-haul version 1310nm S-16.1 V50017-U340-K500 -5 dBm to 0 dBm
3. Long-haul version 1310nm L16.1 V50017-U341-K500 -2 dBm to 3 dBm
4. Long-haul version 1550nm L16.2/3 V50017-U342-K500 -2 dBm to 3 dBm

Tested position:_______________

Step Procedure Expected Result Result Comply


(Y/N)
Connect STM-16 optical output to an optical
1 power meter (see Experimental
arrangement)
Force the laser to start Values should be within the limits
according the following rule:
(Measured value) + (connector
2 loss) = ITU table above.
Connector loss: 0,6 1dB per
connector

Record value of optical transmit power Look at STM16 Interface table


3.1 and enter :
Type No. / Port 1
3.2 --II-----II-- Type No. / Port 2
3.3 --II-----II-- Type No. / Port 3
3.4 --II-----II-- Type No. / Port 4

Field Acceptance Protocol Nokia Siemens Networks 32 (86)


Experimental arrangement

PC/Laptop computer

Q- F/ QB 3

L L
SF2G5/SF160G
i i
n n
e e

IFQ2G5 NE

ODF

Power Meter

Field Acceptance Protocol Nokia Siemens Networks 33 (86)


IFQ2G5B STM-16 Optical Mean Launched Power via ODF
Description: This test gives the steps required to measure the STM-16 optical interface
of the NE. The following item will be tested:

Optical output power of laser

Test equipment: Optical power meter, LCT/NCT

STM-16 interfaces:
Type No. ITU SFP-Module Line launch power
Order Number

1. Intra-office version 1310nm I-16.1 V50017-U343-K500 -10 dBm to -3 dBm


2. Short-haul version 1310nm S-16.1 V50017-U340-K500 -5 dBm to 0 dBm
3. Long-haul version 1310nm L16.1 V50017-U341-K500 -2 dBm to 3 dBm
4. Long-haul version 1550nm L16.2/3 V50017-U342-K500 -2 dBm to 3 dBm

Tested position:_______________

Step Procedure Expected Result Result Comply


(Y/N)
Connect STM-16 optical output to an optical
1 power meter (see Experimental
arrangement)
Force the laser to start Values should be within the limits
according the following rule:
(Measured value) + (connector
2 loss) = ITU table above.
Connector loss: 0,6 1dB per
connector

Record value of optical transmit power Look at STM16 Interface table


3.1 and enter :
Type No. / Port 1
3.2 --II-----II-- Type No. / Port 2
3.3 --II-----II-- Type No. / Port 3
3.4 --II-----II-- Type No. / Port 4

Field Acceptance Protocol Nokia Siemens Networks 34 (86)


Experimental arrangement

PC/Laptop computer

Q- F/ QB 3

L L
SF2G5/SF160G
i i
n n
e e

IFQ2G5 NE

ODF

Power Meter

Field Acceptance Protocol Nokia Siemens Networks 35 (86)


IFQ2G5 STM-16 Optical Receive Power
Description: This test gives the step required to measure the STM-16 optical interface
of the NE. The following item will be tested:

Optical receive power of laser

Test equipment: Optical power meter, LCT/NCT

STM-16 interfaces:
Type No. ITU SFP-Modul Order Line Receive Power
Number

1. Intra-office version 1310nm I-16.1 V50017-U343-K500 -18 dBm to -3 dBm


2. Short-haul version 1310nm S-16.1 V50017-U340-K500 -18 dBm to 0 dBm
3. Long-haul version 1310nm L16.1 V50017-U341-K500 -27 dBm to -9 dBm
4. Long-haul version 1550nm L16.2/3 V50017-U342-K500 -28 dBm to 9 dBm

Tested position:____________ Remote station:__________________

Step Procedure Expected Result Result Comply


(Y/N)
Connect the NE via STM-16 line with the no LOS alarm at appropriate
1 remote station. (see Experimental function unit
arrangement)
Disconnect the optical fibre at the local
2 station and connect it with the optical power
meter
Start the laser Measure the optical receive
power. Look at STM16 Interface
3.1 table and enter :

Type No. / Port 1


3.2 --II-----II-- Type No. / Port 2
3.3 --II-----II-- Type No. / Port 3
3.4 --II-----II-- Type No. / Port 4

Field Acceptance Protocol Nokia Siemens Networks 36 (86)


Experimental arrangement

PC/Laptop computer

QB 3

NE 1 NE 2
ODF
L L L L
i i i i
Local Station STM-16 Remote Station
n n n n
e e e e

Power Meter

Field Acceptance Protocol Nokia Siemens Networks 37 (86)


IFQ2G5B STM-16 Optical Receive Power
Description: This test gives the step required to measure the STM-16 optical interface
of the NE. The following item will be tested:

Optical receive power of laser

Test equipment: Optical power meter, LCT/NCT

STM-16 interfaces:
Type No. ITU SFP-Modul Order Line Receive Power
Number

1. Intra-office version 1310nm I-16.1 V50017-U343-K500 -18 dBm to -3 dBm


2. Short-haul version 1310nm S-16.1 V50017-U340-K500 -18 dBm to 0 dBm
3. Long-haul version 1310nm L16.1 V50017-U341-K500 -27 dBm to -9 dBm
4. Long-haul version 1550nm L16.2/3 V50017-U342-K500 -28 dBm to 9 dBm

Tested position:____________ Remote station:__________________

Step Procedure Expected Result Result Comply


(Y/N)
Connect the NE via STM-16 line with the no LOS alarm at appropriate
1 remote station. (see Experimental function unit
arrangement)
Disconnect the optical fibre at the local
2 station and connect it with the optical power
meter
Start the laser Measure the optical receive
power. Look at STM16 Interface
3.1 table and enter :

Type No. / Port 1


3.2 --II-----II-- Type No. / Port 2
3.3 --II-----II-- Type No. / Port 3
3.4 --II-----II-- Type No. / Port 4

Field Acceptance Protocol Nokia Siemens Networks 38 (86)


Experimental arrangement

PC/Laptop computer

QB 3

NE 1 NE 2
ODF
L L L L
i i i i
Local Station STM-16 Remote Station
n n n n
e e e e

Power Meter

Field Acceptance Protocol Nokia Siemens Networks 39 (86)


IFS10G STM-64 Optical Mean Launched Power via ODF
Description: This test gives the steps required to measure the STM-64 optical interface
of the NE. The following item will be tested:

Optical output power of laser

Test equipment: Optical power meter, LCT/NCT

STM-64 interfaces:
Type Nr. ITU Ordering number Line launch power

1. Intra-office version 1310nm I-64.1 S42024-L5207-A100 -6 dBm to -1 dBm


2. Short-haul version 1310nm S-64.1 S42024-L5207-A110 +1 dBm to +5 dBm
3. Short-haul version 1550nm S-64.2/S-64.3 S42024-L5207-A120 -1 dBm to +2 dBm
4. Long-haul version 1550nm L-64.2b/L-64.3 S42024-L5207-A130 -2 dBm to +2 dBm
5. Long-haul version 1550nm V-64.2/V-64.3 S42024-L5207-A140 +10 dBm to +13 dBm

Tested position:__________________

Step Procedure Expected Result Result Comply


(Y/N)
Connect STM-64 optical output to an optical
1 power meter (see Experimental
arrangement)
Force the laser to start Values should be within the limits
according the following rule:
(Measured value) + (connector
2 loss) = ITU table above.
Connector loss: 0,6 1dB per
connector

Record value of optical transmit power Look at STM64 Interface table


3 and enter :
Type No. / Port 1

Field Acceptance Protocol Nokia Siemens Networks 40 (86)


Experimental arrangement

PC/Laptop computer

Q- F/ QB 3

L L
SF2G5/SF160G
i i
n n
e e

IFS10G NE

ODF

Power Meter

Field Acceptance Protocol Nokia Siemens Networks 41 (86)


IFS10G STM-64 Optical Receive Power
Description: This test gives the step required to measure the STM-64 optical interface
of the NE. The following item will be tested:

Optical receive power of laser

Test equipment: Optical power meter, LCT/NCT

STM-64 interfaces:
Type Nr. ITU Ordering number Line Receive Power

1. Intra-office version 1310nm I-64.1 S42024-L5207-A100 -11 dBm to -1 dBm


2. Short-haul version 1310nm S-64.1 S42024-L5207-A110 -11 dBm to -1 dBm
3. Short-haul version 1550nm S-64.2/S-64.3 S42024-L5207-A120 -14 dBm to -1 dBm
4. Long-haul version 1550nm L-64.2/L-64.3 S42024-L5207-A130 -14 dBm to -1 dBm
5. Long-haul version 1550nm V-64.2/V-64.3 S42024-L5207-A140 -25 dBm to -9 dBm

Tested position:____________ Remote station:__________________

Step Procedure Expected Result Result Comply


(Y/N)
Connect the NE via STM-64 line with the no LOS alarm at appropriate
1 remote station. (see Experimental function unit
arrangement)
Disconnect the optical fibre at the local
2 station and connect it with the optical power
meter
Start the laser Measure the optical receive
power. Look at STM16 Interface
3 table and enter :

Type No. / Port 1

Field Acceptance Protocol Nokia Siemens Networks 42 (86)


Experimental arrangement

PC/Laptop computer

QB 3

NE 1 NE 2
ODF
L L L L
i i i i
Local Station STM-64 Remote Station
n n n n
e e e e

Power Meter

Field Acceptance Protocol Nokia Siemens Networks 43 (86)


IFS10GB STM-64 Optical Mean Launched Power via ODF

with IFSOA/IFSOB/IFSOA-PDC/IFSOB-PDC :

Description: This test gives the steps required to measure the STM-64 optical interface
of the NE. The following item will be tested:

Optical output power of laser

Test equipment: Optical power meter, LCT/NCT

STM-64 interfaces:
Type Nr. ITU Ordering number Line launch power
1. Long-haul version 1550nm L-64.2b S42024-L5267-A130/S42024-L5266- +10 dBm to +13 dBm
A100
2. Long-haul version 1550nm V-64.2a S42024-L5267-A130/S42024-L5264- +10 dBm to +13 dBm
A100
3. Long-haul version 1550nm L-64.3 S42024-L5267-A130/S42024-L5265- +10 dBm to +13 dBm
A100
4. Long-haul version 1550nm V-64.3 S42024-L5267-A130/S42024-L5263- +10 dBm to +13 dBm
A100

Tested position:__________________

Step Procedure Expected Result Result Comply


(Y/N)
Connect STM-64 optical output to an optical
1 power meter (see Experimental
arrangement)
Force the laser to start Values should be within the limits
according the following rule:
(Measured value) + (connector
2 loss) = ITU table above.
Connector loss: 0,6 1dB per
connector

Record value of optical transmit power Look at STM64 Interface table


3 and enter :
Type No. / Port 1

Field Acceptance Protocol Nokia Siemens Networks 44 (86)


Experimental arrangement

PC/Laptop computer

Q- F/ QB 3

L L
SF2G5/SF160G
i i
n n
e e
NE

IFS10G ISFOB/
IFSOB-PDC

ODF

Power Meter

Field Acceptance Protocol Nokia Siemens Networks 45 (86)


PC/Laptop computer

Q- F/ QB 3

L L
SF2G5/SF160G
i i
n n
e e
NE

IFS10G IFSOA/
IFSOA-PDC

ODF

Power Meter

Field Acceptance Protocol Nokia Siemens Networks 46 (86)


IFS10GB STM-64 Optical Receive Power
with IFSOA/IFSOB/IFSOA-PDC/IFSOB-PDC :

Description: This test gives the step required to measure the STM-64 optical interface
of the NE. The following item will be tested:

Optical receive power of laser

Test equipment: Optical power meter, LCT/NCT

STM-64 interfaces:
Type Nr. ITU Ordering number Line launch power
1. Long-haul version 1550nm L-64.2b S42024-L5267-A130/S42024-L5266- -14 dBm to -3 dBm
A100
2. Long-haul version 1550nm V-64.2a S42024-L5267-A130/S42024-L5264- -25 dBm to -9 dBm
A100
3. Long-haul version 1550nm L-64.3 S42024-L5267-A130/S42024-L5265- -13 dBm to -3 dBm
A100
4. Long-haul version 1550nm V-64.3 S42024-L5267-A130/S42024-L5263- -24 dBm to -9 dBm
A100

Tested position:____________ Remote station:__________________

Step Procedure Expected Result Result Comply


(Y/N)
Connect the NE via STM-64 line with the no LOS alarm at appropriate
1 remote station. (see Experimental function unit
arrangement)
Disconnect the optical fibre at the local
2 station and connect it with the optical power
meter
Start the laser Measure the optical receive
power. Look at STM16 Interface
3 table and enter :

Type No. / Port 1

Field Acceptance Protocol Nokia Siemens Networks 47 (86)


Experimental arrangement

PC/Laptop computer

QB 3

NE 1 NE 2
ODF
L L L L
i i i i
Local Station STM-64 Remote Station
n n n n
e e e e

Power Meter

Field Acceptance Protocol Nokia Siemens Networks 48 (86)


IFS10G-WLS STM-64 Optical Mean Launched Power via ODF
Description: This test gives the steps required to measure the STM-64 optical interface
of the NE. The following item will be tested:

Output power of the laser

Test equipment: Optical power meter, LCT/NCT

STM-64 interfaces:
Type No. Frequency Order number Line launche power
THz

1. Interface Single 10 GBit/s WLS S42024-L5284-B100 -2 dBm to +2 dBm

Tested position:________________

Step Procedure Expected Result Result Comply


(Y/N)
Connect STM-64 optical output to an optical
1 power meter (see Experimental
arrangement)
Force the laser to start Values should be within the limits
according the following rule:
(Measured value) + (connector
2 loss) = ITU table above.
Connector loss: 0,6 1dB per
connector

Record value of optical transmit power Look at STM64 Interface table


3.1 and enter :
Type No. / Slot No.:
3.2 --II-----II-- Type No. / Slot No.:
3.3 --II-----II-- Type No. / Slot No.:
3.4 --II-----II-- Type No. / Slot No.:
3.5 --II-----II-- Type No. / Slot No.:
3.6 --II-----II-- Type No. / Slot No.:
3.7 --II-----II-- Type No. / Slot No.:
3.8 --II-----II-- Type No. / Slot No.:
3.9 --II-----II-- Type No. / Slot No.:
3.10 --II-----II-- Type No. / Slot No.:
3.11 --II-----II-- Type No. / Slot No.:
3.12 --II-----II-- Type No. / Slot No.:
3.13 --II-----II-- Type No. / Slot No.:
3.14 --II-----II-- Type No. / Slot No.:
3.15 --II-----II-- Type No. / Slot No.:
3.16 --II-----II-- Type No. / Slot No.:

Field Acceptance Protocol Nokia Siemens Networks 49 (86)


Experimental arrangement

PC/Laptop computer

Q- F/ QB 3

L L
SF2G5/SF160G
i i
n n
e e

IFS10G-WLS NE

ODF

Power Meter

Field Acceptance Protocol Nokia Siemens Networks 50 (86)


IFS10G-WLS STM-64 Optical Receive Power
Description: This test gives the step required to measure the STM-64 optical interface
of the NE. The following item will be tested:

Optical receive power of laser

Test equipment: Optical power meter, LCT/NCT

STM-64 interfaces:
Type No. Frequency Order number Line receive power
THz

1. Interface Single 10 GBit/s WLS S42024-L5284-B100 -14 dBm to -2 dBm

Tested position:____________ Remote NE:__________________

Step Procedure Expected Result Result Comply


(Y/N)
Connect the NE via STM-64 line with the no LOS alarm at appropriate
1 remote station. (see Experimental function unit
arrangement)
Disconnect the optical fibre at the local
2 station and connect it with the optical power
meter
Start the laser Measure the optical receive
power. Look at STM16 Interface
3.1 table and enter :

Type No. / Slot No.:


3.2 --II-----II-- Type No. / Slot No.:
3.3 --II-----II-- Type No. / Slot No.:
3.4 --II-----II-- Type No. / Slot No.:
3.5 --II-----II-- Type No. / Slot No.:
3.6 --II-----II-- Type No. / Slot No.:
3.7 --II-----II-- Type No. / Slot No.:
3.8 --II-----II-- Type No. / Slot No.:
3.9 --II-----II-- Type No. / Slot No.:
3.10 --II-----II-- Type No. / Slot No.:
3.11 --II-----II-- Type No. / Slot No.:
3.12 --II-----II-- Type No. / Slot No.:
3.13 --II-----II-- Type No. / Slot No.:
3.14 --II-----II-- Type No. / Slot No.:
3.15 --II-----II-- Type No. / Slot No.:
3.16 --II-----II-- Type No. / Slot No.:

Field Acceptance Protocol Nokia Siemens Networks 51 (86)


Experimental arrangement

PC/Laptop computer

QB 3

NE 1 NE 2
ODF
L L L L
Local Station
i i i i
Local Station STM-64 or
n n n n
e e e Remote Station e

Power Meter

Field Acceptance Protocol Nokia Siemens Networks 52 (86)


IFS10G-M STM-64 Optical Mean Launched Power via ODF
Description: This test gives the steps required to measure the STM-64 optical interface
of the NE. The following item will be tested:

Output power of the laser

Test equipment: Optical power meter, LCT/NCT

STM-64 interfaces:
Type No. Frequency Order number Line launche power
THz

01. STM-64 Metro WDM Card 1530.33nm 195,9 S42024-L5208-A309 +5 dBm to +7 dBm
02. STM-64 Metro WDM Card 1531.90nm 195,7 S42024-L5208-A317 +5 dBm to +7 dBm
03. STM-64 Metro WDM Card 1533.47nm 195,5 S42024-L5208-A325 +5 dBm to +7 dBm
04. STM-64 Metro WDM Card 1535.04nm 195,3 S42024-L5208-A333 +5 dBm to +7 dBm
05. STM-64 Metro WDM Card 1538.19nm 194,9 S42024-L5208-A349 +5 dBm to +7 dBm
06. STM-64 Metro WDM Card 1539.77nm 194,7 S42024-L5208-A357 +5 dBm to +7 dBm
07. STM-64 Metro WDM Card 1541.35nm 194,5 S42024-L5208-A365 +5 dBm to +7 dBm
08. STM-64 Metro WDM Card 1542.94nm 194,3 S42024-L5208-A373 +5 dBm to +7 dBm
09. STM-64 Metro WDM Card 1547.72nm 193,7 S42024-L5208-A397 +5 dBm to +7 dBm
10. STM-64 Metro WDM Card 1549.32nm 193,5 S42024-L5208-A405 +5 dBm to +7 dBm
11. STM-64 Metro WDM Card 1550.92nm 193,3 S42024-L5208-A413 +5 dBm to +7 dBm
12. STM-64 Metro WDM Card 1552.52nm 193,1 S42024-L5208-A421 +5 dBm to +7 dBm
13. STM-64 Metro WDM Card 1555.75nm 192,7 S42024-L5208-A437 +5 dBm to +7 dBm
14. STM-64 Metro WDM Card 1557.36nm 192,5 S42024-L5208-A445 +5 dBm to +7 dBm
15. STM-64 Metro WDM Card 1558.98nm 192,3 S42024-L5208-A453 +5 dBm to +7 dBm
16. STM-64 Metro WDM Card 1560.61nm 192,1 S42024-L5208-A461 +5 dBm to +7 dBm
17. STM-64 Metro WDM Card 1570.42nm 190,9 S42024-L5208-A509 +5 dBm to +7 dBm
18. STM-64 Metro WDM Card 1572.06nm 190,7 S42024-L5208-A517 +5 dBm to +7 dBm
19. STM-64 Metro WDM Card 1573.71nm 190,5 S42024-L5208-A525 +5 dBm to +7 dBm
20. STM-64 Metro WDM Card 1575.37nm 190,3 S42024-L5208-A533 +5 dBm to +7 dBm
21. STM-64 Metro WDM Card 1578.69nm 189,9 S42024-L5208-A549 +5 dBm to +7 dBm
22. STM-64 Metro WDM Card 1580.35nm 189,7 S42024-L5208-A557 +5 dBm to +7 dBm
23. STM-64 Metro WDM Card 1582.02nm 189,5 S42024-L5208-A565 +5 dBm to +7 dBm
24. STM-64 Metro WDM Card 1583.69nm 189,3 S42024-L5208-A573 +5 dBm to +7 dBm
25. STM-64 Metro WDM Card 1588.73nm 188,7 S42024-L5208-A597 +5 dBm to +7 dBm
26. STM-64 Metro WDM Card 1590.41nm 188,5 S42024-L5208-A605 +5 dBm to +7 dBm
27. STM-64 Metro WDM Card 1592.10nm 188,3 S42024-L5208-A613 +5 dBm to +7 dBm
28. STM-64 Metro WDM Card 1593.79nm 188,1 S42024-L5208-A621 +5 dBm to +7 dBm
29. STM-64 Metro WDM Card 1597.19nm 187,7 S42024-L5208-A637 +5 dBm to +7 dBm
30. STM-64 Metro WDM Card 1598.89nm 187,5 S42024-L5208-A645 +5 dBm to +7 dBm
31. STM-64 Metro WDM Card 1600.60nm 187,3 S42024-L5208-A653 +5 dBm to +7 dBm
32. STM-64 Metro WDM Card 1602.31nm 187,1 S42024-L5208-A661 +5 dBm to +7 dBm

Field Acceptance Protocol Nokia Siemens Networks 53 (86)


Tested position:________________

Step Procedure Expected Result Result Comply


(Y/N)
Connect STM-64 optical output to an optical
1 power meter (see Experimental
arrangement)
Force the laser to start Values should be within the limits
according the following rule:
(Measured value) + (connector
2 loss) = ITU table above.
Connector loss: 0,6 1dB per
connector

Record value of optical transmit power Look at STM64 Interface table


3.1 and enter :
Type No. / Slot No.:
3.2 --II-----II-- Type No. / Slot No.:
3.3 --II-----II-- Type No. / Slot No.:
3.4 --II-----II-- Type No. / Slot No.:
3.5 --II-----II-- Type No. / Slot No.:
3.6 --II-----II-- Type No. / Slot No.:
3.7 --II-----II-- Type No. / Slot No.:
3.8 --II-----II-- Type No. / Slot No.:
3.9 --II-----II-- Type No. / Slot No.:
3.10 --II-----II-- Type No. / Slot No.:
3.11 --II-----II-- Type No. / Slot No.:
3.12 --II-----II-- Type No. / Slot No.:
3.13 --II-----II-- Type No. / Slot No.:
3.14 --II-----II-- Type No. / Slot No.:
3.15 --II-----II-- Type No. / Slot No.:
3.16 --II-----II-- Type No. / Slot No.:

Experimental arrangement

PC/Laptop computer

Q- F/ QB 3

L L
SF2G5/SF160G
i i
n n
e e

IFS10G-M NE

ODF

Power Meter

Field Acceptance Protocol Nokia Siemens Networks 54 (86)


IFS10G-M STM-64 Optical Receive Power
Description: This test gives the step required to measure the STM-64 optical interface
of the NE. The following item will be tested:

Optical receive power of laser

Test equipment: Optical power meter, LCT/NCT

STM-64 interfaces:
Type No. Frequency Order number Line receive power
THz

01. STM-64 Metro WDM Card 1530.33nm 195,9 S42024-L5208-A309 -21 dBm to -7 dBm
02. STM-64 Metro WDM Card 1531.90nm 195,7 S42024-L5208-A317 -21 dBm to -7 dBm
03. STM-64 Metro WDM Card 1533.47nm 195,5 S42024-L5208-A325 -21 dBm to -7 dBm
04. STM-64 Metro WDM Card 1535.04nm 195,3 S42024-L5208-A333 -21 dBm to -7 dBm
05. STM-64 Metro WDM Card 1538.19nm 194,9 S42024-L5208-A349 -21 dBm to -7 dBm
06. STM-64 Metro WDM Card 1539.77nm 194,7 S42024-L5208-A357 -21 dBm to -7 dBm
07. STM-64 Metro WDM Card 1541.35nm 194,5 S42024-L5208-A365 -21 dBm to -7 dBm
08. STM-64 Metro WDM Card 1542.94nm 194,3 S42024-L5208-A373 -21 dBm to -7 dBm
09. STM-64 Metro WDM Card 1547.72nm 193,7 S42024-L5208-A397 -21 dBm to -7 dBm
10. STM-64 Metro WDM Card 1549.32nm 193,5 S42024-L5208-A405 -21 dBm to -7 dBm
11. STM-64 Metro WDM Card 1550.92nm 193,3 S42024-L5208-A413 -21 dBm to -7 dBm
12. STM-64 Metro WDM Card 1552.52nm 193,1 S42024-L5208-A421 -21 dBm to -7 dBm
13. STM-64 Metro WDM Card 1555.75nm 192,7 S42024-L5208-A437 -21 dBm to -7 dBm
14. STM-64 Metro WDM Card 1557.36nm 192,5 S42024-L5208-A445 -21 dBm to -7 dBm
15. STM-64 Metro WDM Card 1558.98nm 192,3 S42024-L5208-A453 -21 dBm to -7 dBm
16. STM-64 Metro WDM Card 1560.61nm 192,1 S42024-L5208-A461 -21 dBm to -7 dBm
17. STM-64 Metro WDM Card 1570.42nm 190,9 S42024-L5208-A509 -21 dBm to -7 dBm
18. STM-64 Metro WDM Card 1572.06nm 190,7 S42024-L5208-A517 -21 dBm to -7 dBm
19. STM-64 Metro WDM Card 1573.71nm 190,5 S42024-L5208-A525 -21 dBm to -7 dBm
20. STM-64 Metro WDM Card 1575.37nm 190,3 S42024-L5208-A533 -21 dBm to -7 dBm
21. STM-64 Metro WDM Card 1578.69nm 189,9 S42024-L5208-A549 -21 dBm to -7 dBm
22. STM-64 Metro WDM Card 1580.35nm 189,7 S42024-L5208-A557 -21 dBm to -7 dBm
23. STM-64 Metro WDM Card 1582.02nm 189,5 S42024-L5208-A565 -21 dBm to -7 dBm
24. STM-64 Metro WDM Card 1583.69nm 189,3 S42024-L5208-A573 -21 dBm to -7 dBm
25. STM-64 Metro WDM Card 1588.73nm 188,7 S42024-L5208-A597 -21 dBm to -7 dBm
26. STM-64 Metro WDM Card 1590.41nm 188,5 S42024-L5208-A605 -21 dBm to -7 dBm
27. STM-64 Metro WDM Card 1592.10nm 188,3 S42024-L5208-A613 -21 dBm to -7 dBm
28. STM-64 Metro WDM Card 1593.79nm 188,1 S42024-L5208-A621 -21 dBm to -7 dBm
29. STM-64 Metro WDM Card 1597.19nm 187,7 S42024-L5208-A637 -21 dBm to -7 dBm
30. STM-64 Metro WDM Card 1598.89nm 187,5 S42024-L5208-A645 -21 dBm to -7 dBm
31. STM-64 Metro WDM Card 1600.60nm 187,3 S42024-L5208-A653 -21 dBm to -7 dBm
32. STM-64 Metro WDM Card 1602.31nm 187,1 S42024-L5208-A661 -21 dBm to -7 dBm

Field Acceptance Protocol Nokia Siemens Networks 55 (86)


Tested position:____________ Remote NE:__________________

Step Procedure Expected Result Result Comply


(Y/N)
Connect the NE via STM-64 line with the no LOS alarm at appropriate
1 remote station. (see Experimental function unit
arrangement)
Disconnect the optical fibre at the local
2 station and connect it with the optical power
meter
Start the laser Measure the optical receive
power. Look at STM16 Interface
3.1 table and enter :

Type No. / Slot No.:


3.2 --II-----II-- Type No. / Slot No.:
3.3 --II-----II-- Type No. / Slot No.:
3.4 --II-----II-- Type No. / Slot No.:
3.5 --II-----II-- Type No. / Slot No.:
3.6 --II-----II-- Type No. / Slot No.:
3.7 --II-----II-- Type No. / Slot No.:
3.8 --II-----II-- Type No. / Slot No.:
3.9 --II-----II-- Type No. / Slot No.:
3.10 --II-----II-- Type No. / Slot No.:
3.11 --II-----II-- Type No. / Slot No.:
3.12 --II-----II-- Type No. / Slot No.:
3.13 --II-----II-- Type No. / Slot No.:
3.14 --II-----II-- Type No. / Slot No.:
3.15 --II-----II-- Type No. / Slot No.:
3.16 --II-----II-- Type No. / Slot No.:

Experimental arrangement

PC/Laptop computer

QB 3

NE 1 NE 2
ODF
L L L L
Local Station
i i i i
Local Station STM-64 or
n n n n
e e e Remote Station e

Power Meter

Field Acceptance Protocol Nokia Siemens Networks 56 (86)


IFS10G-R STM-64 Optical Mean Launched Power via ODF
Description: This test gives the steps required to measure the STM-64 optical interface
of the NE. The following item will be tested:

Output power of the laser

Test equipment: Optical power meter, LCT/NCT

STM-64 interfaces:
Type No. Frequency Order number Line launche power
THz

1. Interface Single 10 GBit/s Regio MTS S42024-L5231-B100 -2 dBm to +2 dBm

Tested position:________________

Step Procedure Expected Result Result Comply


(Y/N)
Connect STM-64 optical output to an optical
1 power meter (see Experimental
arrangement)
Force the laser to start Values should be within the limits
according the following rule:
(Measured value) + (connector
2 loss) = ITU table above.
Connector loss: 0,6 1dB per
connector

Record value of optical transmit power Look at STM64 Interface table


3.1 and enter :
Type No. / Slot No.:
3.2 --II-----II-- Type No. / Slot No.:
3.3 --II-----II-- Type No. / Slot No.:
3.4 --II-----II-- Type No. / Slot No.:
3.5 --II-----II-- Type No. / Slot No.:
3.6 --II-----II-- Type No. / Slot No.:
3.7 --II-----II-- Type No. / Slot No.:
3.8 --II-----II-- Type No. / Slot No.:
3.9 --II-----II-- Type No. / Slot No.:
3.10 --II-----II-- Type No. / Slot No.:
3.11 --II-----II-- Type No. / Slot No.:
3.12 --II-----II-- Type No. / Slot No.:
3.13 --II-----II-- Type No. / Slot No.:
3.14 --II-----II-- Type No. / Slot No.:
3.15 --II-----II-- Type No. / Slot No.:
3.16 --II-----II-- Type No. / Slot No.:

Field Acceptance Protocol Nokia Siemens Networks 57 (86)


Experimental arrangement

PC/Laptop computer

Q- F/ QB 3

L L
SF2G5/SF160G
i i
n n
e e

IFS10G-M NE

ODF

Power Meter

Field Acceptance Protocol Nokia Siemens Networks 58 (86)


IFS10G-R STM-64 Optical Receive Power
Description: This test gives the step required to measure the STM-64 optical interface
of the NE. The following item will be tested:

Optical receive power of laser

Test equipment: Optical power meter, LCT/NCT

STM-64 interfaces:
Type No. Frequency Order number Line receive power
THz

1. Interface Single 10 GBit/s Regio MTS S42024-L5231-B100 -14 dBm to -2 dBm

Tested position:____________ Remote NE:__________________

Step Procedure Expected Result Result Comply


(Y/N)
Connect the NE via STM-64 line with the no LOS alarm at appropriate
1 remote station. (see Experimental function unit
arrangement)
Disconnect the optical fibre at the local
2 station and connect it with the optical power
meter
Start the laser Measure the optical receive
power. Look at STM16 Interface
3.1 table and enter :

Type No. / Slot No.:


3.2 --II-----II-- Type No. / Slot No.:
3.3 --II-----II-- Type No. / Slot No.:
3.4 --II-----II-- Type No. / Slot No.:
3.5 --II-----II-- Type No. / Slot No.:
3.6 --II-----II-- Type No. / Slot No.:
3.7 --II-----II-- Type No. / Slot No.:
3.8 --II-----II-- Type No. / Slot No.:
3.9 --II-----II-- Type No. / Slot No.:
3.10 --II-----II-- Type No. / Slot No.:
3.11 --II-----II-- Type No. / Slot No.:
3.12 --II-----II-- Type No. / Slot No.:
3.13 --II-----II-- Type No. / Slot No.:
3.14 --II-----II-- Type No. / Slot No.:
3.15 --II-----II-- Type No. / Slot No.:
3.16 --II-----II-- Type No. / Slot No.:

Field Acceptance Protocol Nokia Siemens Networks 59 (86)


Experimental arrangement

PC/Laptop computer

QB 3

NE 1 NE 2
ODF
L L L L
Local Station
i i i i
Local Station STM-64 or
n n n n
e e e Remote Station e

Power Meter

Field Acceptance Protocol Nokia Siemens Networks 60 (86)


IFS10G-R STM-64 Optical Mean Launched Power via ODF
with IFSOA/IFSOB/IFSOA-PDC/IFSOB-PDC :

Description: This test gives the steps required to measure the STM-64 optical interface
of the NE. The following item will be tested:

Output power of the laser

Test equipment: Optical power meter, LCT/NCT

STM-64 interfaces:
Type No. ITU Order number Line receive power

1. Ultra long haul application 1550nm JE44 db-64.2/3/4/5 S42024-L5231-C100 +10dBm to +13 dBm

Tested position:________________

Step Procedure Expected Result Result Comply


(Y/N)
Connect STM-64 optical output to an optical
1 power meter (see Experimental
arrangement)
Force the laser to start Values should be within the limits
according the following rule:
(Measured value) + (connector
2 loss) = ITU table above.
Connector loss: 0,6 1dB per
connector

Record value of optical transmit power Look at STM64 Interface table


3 and enter :

Field Acceptance Protocol Nokia Siemens Networks 61 (86)


Experimental arrangement

PC/Laptop computer

Q- F/ QB 3

L L
i SF2G5/SF160G i
n n
e e
NE

IFS10G-R IFSOA/
ISFOB/
IFSOB-PDC
IFSOA-PDC

ODF

Power Meter

Field Acceptance Protocol Nokia Siemens Networks 62 (86)


IFS10G-R STM-64 Optical Receive Power
with IFSOA/IFSOB/IFSOA-PDC/IFSOB-PDC :

Description: This test gives the step required to measure the STM-64 optical interface
of the NE. The following item will be tested:

Optical receive power of laser

Test equipment: Optical power meter, LCT/NCT

STM-64 interfaces:
Type No. ITU Order number Line receive power

1. Ultra long haul application 1550nm JE44 db-64.2/3/4/5 S42024-L5231-C100 -36dBm to -9 dBm

Tested position:____________ Remote NE:__________________

Step Procedure Expected Result Result Comply


(Y/N)
Connect the NE via STM-64 line with the no LOS alarm at appropriate
1 remote station. (see Experimental function unit
arrangement)
Disconnect the optical fibre at the local
2 station and connect it with the optical power
meter
Start the laser Measure the optical receive
power. Look at STM16 Interface
3 table and enter :

Type No. / Port 1

Field Acceptance Protocol Nokia Siemens Networks 63 (86)


Experimental arrangement

PC/Laptop computer

QB 3

NE 1 NE 2
ODF
L L L L
i i i i
Local Station STM-64 Remote Station
n n n n
e e e e

Power Meter

Field Acceptance Protocol Nokia Siemens Networks 64 (86)


IFS40G-MX STM-256 Optical Mean Launched Power via ODF

with IFS10G WDM :

Description: This test gives the steps required to measure the IFS40G-MX optical
interface card of the NE. The following item will be tested:

Output power of the laser

Test equipment: Optical power meter, LCT/NCT

STM-64 IFS10G and STM-256 Interfaces of IFS40G-MX Card:


Type No. Frequency Order number Line launch power
THz

01. STM-64 interface port "C49" -1 dBm to +2 dBm


1538.19nm 194,9 S42024-L5213-A100/S42024-L5207-A349
02. STM-64 interface port "C47" -1 dBm to +2 dBm
1539.77nm 194,7 S42024-L5213-A100/S42024-L5207-A357
03. STM-64 interface port "C45" -1 dBm to +2 dBm
1541.35nm 194,5 S42024-L5213-A100/S42024-L5207-A365
04. STM-64 interface port "C43" -1 dBm to +2 dBm
1542.94nm 194,3 S42024-L5213-A100/S42024-L5207-A373
+1.4 dBm to +7.1
05. STM-256 interface port "S" S42024-L5213-A100 dBm

Tested position:________________

Step Procedure Expected Result Result Comply


(Y/N)
Connect STM-64 and STM-256 optical output
1 interfaces of IFS40G-MX to an optical power
meter. (see Experimental arrangement)
Force the laser to start. Values should be within the limits
according the following rule:
(Measured value) + (connector
2 loss) = ITU table above.
Connector loss: 0,6 1dB per
connector

Record value of optical transmit power. Look at STM-64 and STM-256


3.1 Interface table and fill in Slot No.:
Type No. 1 / Slot No.
3.2 --II-----II-- Type No. 2 / Slot No.
3.3 --II-----II-- Type No. 3 / Slot No.
3.4 --II-----II-- Type No. 4 / Slot No.
3.5 --II-----II-- Type No. 5 / Slot No.

Field Acceptance Protocol Nokia Siemens Networks 65 (86)


LCT/NCT

Local NE
or
Remote NE Local NE Remote NE
QB3 QB3 QB3

Field Acceptance Protocol


ODF IFS40G-MX ODF IFS40G-MX
Experimental arrangement

STM-64 coloured STM-64 coloured

C 49
C 49

IFS10G-WDM
IFS10G-WDM

R S

STM-64 coloured STM-64 coloured

C 47
C 47

Nokia Siemens Networks


IFS10G-WDM
IFS10G-WDM

STM-256

STM-64 coloured STM-64 coloured

C 45
C 45

IFS10G-WDM
IFS10G-WDM

S R

STM-64 coloured STM-64 coloured


C 43
C 43

IFS10G-WDM
IFS10G-WDM

Power Meter

66 (86)
with IFS10GB :

Description: This test gives the steps required to measure the IFS40G-MX optical
interface card of the NE. The following item will be tested:

Output power of the laser

Test equipment: Optical power meter, LCT/NCT

STM-64 IFS10GB and STM-256 Interfaces of IFS40G-MX Card:


Type No. Frequency Order number Line launch power
THz

01. STM-64 interface port "C49" -1 dBm to +2 dBm


1538.19nm 194,9 S42024-L5213-A100/S42024-L5267-A349
02. STM-64 interface port "C47" -1 dBm to +2 dBm
1539.77nm 194,7 S42024-L5213-A100/S42024-L5267-A357
03. STM-64 interface port "C45" -1 dBm to +2 dBm
1541.35nm 194,5 S42024-L5213-A100/S42024-L5267-A365
04. STM-64 interface port "C43" -1 dBm to +2 dBm
1542.94nm 194,3 S42024-L5213-A100/S42024-L5267-A373
+1.4 dBm to +7.1
05. STM-256 interface port "S" S42024-L5213-A100 dBm

Tested position:________________

Step Procedure Expected Result Result Comply


(Y/N)
Connect STM-64 and STM-256 optical output
1 interfaces of IFS40G-MX to an optical power
meter. (see Experimental arrangement)
Force the laser to start. Values should be within the limits
according the following rule:
(Measured value) + (connector
2 loss) = ITU table above.
Connector loss: 0,6 1dB per
connector

Record value of optical transmit power. Look at STM-64 and STM-256


3.1 Interface table and fill in Slot No.:
Type No. 1 / Slot No.
3.2 --II-----II-- Type No. 2 / Slot No.
3.3 --II-----II-- Type No. 3 / Slot No.
3.4 --II-----II-- Type No. 4 / Slot No.
3.5 --II-----II-- Type No. 5 / Slot No.

Field Acceptance Protocol Nokia Siemens Networks 67 (86)


Experimental arrangement
Remote NE
IFS10GB-WDM IFS10GB-WDM IFS10GB-WDM IFS10GB-WDM

STM-64 coloured STM-64 coloured STM-64 STM-64 coloured


coloured

QB3

IFS40G-MX
C 49 C 47 C 45 C 43
S R

STM-256
Power Meter

ODF

Local NE

IFS40G-MX
QB3 R S
C 49 C C 45 C 43
47

LCT/NC
T

ODF

STM-64 coloured STM-64 coloured STM-64 coloured STM-64 coloured

LocalRemote
NE NE
or

QB3

IFS10GB-WDM IFS10GB-WDM IFS10GB-WDM IFS10GB-WDM

Field Acceptance Protocol Nokia Siemens Networks 68 (86)


IFS40G-MX STM-256 Optical Receive Power
with IFS10G WDM :

Description: This test gives the steps required to measure the optical receive power of
the IFS40G-MX card. The following item will be tested:

Optical receive power

Test equipment: Optical power meter, LCT/NCT

STM-64 IFS10G and STM-256 Interfaces of IFS40G-MX Card:


Type No. Frequency Order number Receive power
THz

01. STM-64 interface port "C49" -15 dBm to 0 dBm


1538.19nm 194,9 S42024-L5213-A100/S42024-L5207-A349
02. STM-64 interface port "C47" -15 dBm to 0 dBm
1539.77nm 194,7 S42024-L5213-A100/S42024-L5207-A357
03. STM-64 interface port "C45" -15 dBm to 0 dBm
1541.35nm 194,5 S42024-L5213-A100/S42024-L5207-A365
04. STM-64 interface port "C43" -15 dBm to 0 dBm
1542.94nm 194,3 S42024-L5213-A100/S42024-L5207-A373
05. STM-256 interface port "S" S42024-L5213-A100 -4.4 dBm to +7.1 dBm

Tested position:____________ Remote NE:__________________

Step Procedure Expected Result Result Comply


(Y/N)
Connect the IFS40G-MX STM-64 interfaces No LOS alarm at appropriate
with IFS10G-WDM cards and the 40G function unit.
1 interface with the remote station. (see
Experimental arrangement)

Disconnect the optical fibre one after an


2 other at the local station and connect it with
the optical power meter.
Start the laser of the corresponding port. Measure the optical receive
3.1
power.
Record the measured optical receive value. Look at STM-64 and STM-256
Interface table and fill in the Slot
3.2 No.:
Type No. 1 / Slot No.
3.3 --II-----II-- Type No. 2 / Slot No.
3.4 --II-----II-- Type No. 3 / Slot No.
3.5 --II-----II-- Type No. 4 / Slot No.
3.6 --II-----II-- Type No. 5 / Slot No.

Field Acceptance Protocol Nokia Siemens Networks 69 (86)


LCT/NCT

Local NE
or
Remote NE Local NE Remote NE
QB3 QB3 QB3

Field Acceptance Protocol


ODF IFS40G-MX ODF IFS40G-MX
Experimental arrangement

STM-64 coloured STM-64 coloured

C 49
C 49

IFS10G-WDM
IFS10G-WDM

S R

STM-64 coloured STM-64 coloured

C 47
C 47

Nokia Siemens Networks


IFS10G-WDM
IFS10G-WDM

STM-256

STM-64 coloured STM-64 coloured

C 45
C 45

IFS10G-WDM
IFS10G-WDM

R S

STM-64 coloured STM-64 coloured


C 43
C 43

IFS10G-WDM
IFS10G-WDM

Power Meter

70 (86)
with IFS10GB :
Description: This test gives the steps required to measure the optical receive power of
the IFS40G-MX card. The following item will be tested:

Optical receive power

Test equipment: Optical power meter, LCT/NCT

STM-64 IFS10GB and STM-256 Interfaces of IFS40G-MX Card:


Type No. Frequency Order number Receive power
THz

01. STM-64 interface port "C49" -15 dBm to 0 dBm


1538.19nm 194,9 S42024-L5213-A100/S42024-L5267-A349
02. STM-64 interface port "C47" -15 dBm to 0 dBm
1539.77nm 194,7 S42024-L5213-A100/S42024-L5267-A357
03. STM-64 interface port "C45" -15 dBm to 0 dBm
1541.35nm 194,5 S42024-L5213-A100/S42024-L5267-A365
04. STM-64 interface port "C43" -15 dBm to 0 dBm
1542.94nm 194,3 S42024-L5213-A100/S42024-L5267-A373
05. STM-256 interface port "S" S42024-L5213-A100 -4.4 dBm to +7.1 dBm

Tested position:____________ Remote NE:__________________

Step Procedure Expected Result Result Comply


(Y/N)
Connect the IFS40G-MX STM-64 interfaces No LOS alarm at appropriate
with IFS10G-WDM cards and the 40G function unit.
1 interface with the remote station. (see
Experimental arrangement)

Disconnect the optical fibre one after an


2 other at the local station and connect it with
the optical power meter.

Start the laser of the corresponding port. Measure the optical receive
3.1
power.
Record the measured optical receive value. Look at STM-64 and STM-256
Interface table and fill in the Slot
3.2 No.:
Type No. 1 / Slot No.
3.3 --II-----II-- Type No. 2 / Slot No.
3.4 --II-----II-- Type No. 3 / Slot No.
3.5 --II-----II-- Type No. 4 / Slot No.
3.6 --II-----II-- Type No. 5 / Slot No.

Field Acceptance Protocol Nokia Siemens Networks 71 (86)


Experimental arrangement
Remote NE
IFS10GB-WDM IFS10GB-WDM IFS10GB-WDM IFS10GB-WDM

STM-64 coloured STM-64 coloured STM-64 coloured STM-64 coloured

QB3

IFS40G-
MX C 49 C 47 C 45 C 43
R S

STM-256

ODF

Power Meter
Local NE

IFS40G-MX
QB3 S R
C 49 C 47 C 45 C 43

LCT/NCT

ODF

STM-64 coloured STM-64 coloured STM-64 coloured STM-64 coloured

LocalRemote
NE NE
or

QB3

IFS10GB-WDM IFS10GB-WDM IFS10GB-WDM IFS10GB-WDM

Field Acceptance Protocol Nokia Siemens Networks 72 (86)


IFOFE-E Throughput, Latency and Frame Loss (RFC2544)
Test
Description: This test gives the step to measure the Ethernet-functionality of the NE.
The test is valid for IFOFE-E cards. The following items will be tested:

Frame Loss, throughput and latency

Test equipment: Ethernet test set, LCT/NCT

Tested position:______________

Step Procedure Expected Result Result Comply


(Y/N)
Connect the NE via STM-16/STM-4 line with no LOS alarm at appropriate
1 the remote station. function unit
Configure the Ethernet card and connect the A flash at the connector shall be
2 test set (Sub channeling must be disabled) present because of polling
Enable the "internal loop back" function at Test set receives signal
3 the remote station
Do a quick RFC2544-measurement with the
4 ETH analyzer at the LAN-connector No packet loss and low latency

Reconfigure the Ethernet card as required


5 and unplug the measurement equippment. No alarm

Field Acceptance Protocol Nokia Siemens Networks 73 (86)


IFOFE Throughput, Latency and Frame Loss (RFC2544) Test
Description: This test gives the step to measure the Ethernet-functionality of the NE.
The test is valid for IFOFE cards. The following items will be tested:

Frame Loss, throughput and latency

Test equipment: Ethernet test set, LCT/NCT

Tested position:______________

Step Procedure Expected Result Result Comply


(Y/N)
Connect the NE via STM-16/STM-4 line with no LOS alarm at appropriate
1 the remote station. function unit
Configure the Ethernet card and connect the A flash at the connector shall be
2 test set (Sub channeling must be disabled) present because of polling
Enable the "internal loop back" function at Test set receives signal
3 the remote station
Do a quick RFC2544-measurement with the
4 ETH analyzer at the LAN-connector No packet loss and low latency

Reconfigure the Ethernet card as required


5 and unplug the measurement equippment. No alarm

Field Acceptance Protocol Nokia Siemens Networks 74 (86)


IFQGBE Throughput, Latency and Frame Loss (RFC2544) Test
Description: This test gives the step to measure the Ethernet-functionality of the NE.
The test is valid for IFQGBE cards. The following items will be tested:

Frame Loss, throughput and latency

Test equipment: Ethernet test set, LCT/NCT

Tested position:______________

Step Procedure Expected Result Result Comply


(Y/N)
Connect the NE via STM-64/STM-16 line no LOS alarm at appropriate
1 with the remote station. function unit
Configure the Ethernet card and connect the
2 test set (Sub channeling must be disabled)
Enable the "internal loop back" function at Test set receives signal
3 the remote station
Do a quick RFC2544-measurement with the
4 ETH analyzer at the LAN-connector No packet loss and low latency

Reconfigure the Ethernet card as required


5 and unplug the measurement equippment. No alarm

Field Acceptance Protocol Nokia Siemens Networks 75 (86)


IFQGBEB Throughput, Latency and Frame Loss (RFC2544)
Test
Description: This test gives the step to measure the Ethernet-functionality of the NE.
The test is valid for IFQGBEB cards. The following items will be tested:

Frame Loss, throughput and latency

Test equipment: Ethernet test set, LCT/NCT

Tested position:______________

Step Procedure Expected Result Result Comply


(Y/N)
Connect the NE via STM-64/STM-16 line no LOS alarm at appropriate
1 with the remote station. function unit
Configure the Ethernet card and connect the
2 test set (Sub channeling must be disabled)
Enable the "internal loop back" function at Test set receives signal
3 the remote station
Do a quick RFC2544-measurement with the
4 ETH analyzer at the LAN-connector No packet loss and low latency

Reconfigure the Ethernet card as required


5 and unplug the measurement equippment. No alarm

Field Acceptance Protocol Nokia Siemens Networks 76 (86)


IFQGBE-E Throughput, Latency and Frame Loss (RFC2544)
Test
Description: This test gives the step to measure the Ethernet-functionality of the NE.
The test is valid for IFQGBE-E cards. The following items will be tested:

Frame Loss, throughput and latency

Test equipment: Ethernet test set, LCT/NCT

Tested position:_______________

Step Procedure Expected Result Result Comply


(Y/N)
Connect the NE via STM-64/STM-16 line no LOS alarm at appropriate
1 with the remote station. function unit
Configure the Ethernet card and connect the A flash at the connector shall be
2 test set (Sub channeling must be disabled) present because of polling
Enable the "internal loop back" function at Test set receives signal
3 the remote station
Do a quick RFC2544-measurement with the
4 ETH analyzer at the LAN-connector No packet loss and low latency

Reconfigure the Ethernet card as required


5 and unplug the measurement equippment. No alarm

Field Acceptance Protocol Nokia Siemens Networks 77 (86)


IFQGBEB-E Throughput, Latency and Frame Loss (RFC2544)
Test
Description: This test gives the step to measure the Ethernet-functionality of the NE.
The test is valid for IFQGBE cards. The following items will be tested:

Frame Loss, throughput and latency

Test equipment: Ethernet test set, LCT/NCT

Tested position:______________

Step Procedure Expected Result Result Comply


(Y/N)
Connect the NE via STM-64/STM-16 line no LOS alarm at appropriate
1 with the remote station. function unit
Configure the Ethernet card and connect the
2 test set (Sub channeling must be disabled)
Enable the "internal loop back" function at Test set receives signal
3 the remote station
Do a quick RFC2544-measurement with the
4 ETH analyzer at the LAN-connector No packet loss and low latency

Reconfigure the Ethernet card as required


5 and unplug the measurement equippment. No alarm

Field Acceptance Protocol Nokia Siemens Networks 78 (86)


IFOFES-E Throughput, Latency and Frameloss (RFC2544)
Test
Description: This test gives the step to measure the Ethernet-functionality of the NE.
The test is valid for IFOFES-E cards. The following item will be tested:

Frame loss, throughput and latency

Test equipment: Ethernet test set, LCT/NCT

Tested position:______________

Step Procedure Expected Result Result Comply


(Y/N)
Connect the NE via STM-16/STM-4 line with no LOS alarm at appropriate
1 the remote station. function unit
Configure the Ethernet card and connect the A flash at the connector shall be
2 test set present because of polling
Enable the "internal loop back" function at Test set receives signal
3 the remote station
Do a quick RFC2544-measurement with the
4 ETH analyzer at the LAN-connector No packet loss and low latency

Reconfigure the Ethernet card as required


5 and unplug the measurement equipment. No alarm

Field Acceptance Protocol Nokia Siemens Networks 79 (86)


IF2M Cabling Test
Description: This test gives the steps required to check the PDH-port cabling of the NE.
The following item will be tested:

Testing of distributor connections

Test equipment: LCT/NCT; SDH/PDH analyzer

Tested positions:________________
Step Procedure Expected Result Result Comply
(Y/N)
1 Configure NE with IF2M PDH trib as
required and adjust internal loops via the
switching fabric on the appropriate VC-level
for every channel which has to be tested.
(see Experimental arrangement)

2 If the NE is equipped with line cards then


perform a cross-connection (only one
channel) to the appropriate line side and
loop the line side.
Use 10dB attenuation if looping an optical
signal.
This is necessary to test the line side locally.

3 Do a short (few seconds) bit error-test with -no bit errors


the PDH analyzer at the distributor for all
PDH tributaries.
Use PRBS15 for 2 Mbit/s trib.

Experimental arrangement

PC/Laptop computer

Q- F/ QB 3

10 dB
L L T
SF2G5/SF160G
i i
n n
e e

IF2M

DDF

SDH Analyser

Field Acceptance Protocol Nokia Siemens Networks 80 (86)


IF345M Cabling Test
Description: This test gives the steps required to check the PDH-port cabling of the NE.
The following item will be tested:

Testing of distributor connections

Test equipment: LCT/NCT; SDH/PDH analyzer

Tested positions:________________
Step Procedure Expected Result Result Comply
(Y/N)
1 Configure NE with IF345M PDH trib as
required and adjust internal loops via the
switching fabric on the appropriate VC-
level for every channel which has to be
tested. (see Experimental arrangement)

2 If the NE is equipped with line cards then


perform a cross-connection (only one
channel) to the appropriate line side and
loop the line side.
Use 10dB attenuation if looping an optical
signal.
This is necessary to test the line side
locally.

3 Do a short (few seconds) bit error-test -no bit errors


with the PDH analyzer at the distributor
for all PDH tributaries.
Use PRBS15 for 34 Mbit/s trib.

Experimental arrangement

PC/Laptop computer

Q- F/ QB 3

10 dB
L L T
SF2G5/SF160G
i i
n n
e e

IF345M

DDF

SDH Analyser

Field Acceptance Protocol Nokia Siemens Networks 81 (86)


IFO155M-E - STM-1 Cabling test
Description: This test gives the steps required to check the STM-1 cabling of the NE.
The following items will be tested:

Test equipment: SDH-analyzer

Tested positions:_______________

Step Procedure Expected Result Comply


(Y/N)
1 Configure NE with STM-1 tribs as
required and adjust internal loops via the
switching network on the VC-4 level.*

2 If the NE is equipped with lines cards


then perform a cross-connection (only
one VC-4) to the appropriate line side and
loop the line side.
Use 10dB attenuation if looping an optical
side (STM-4, STM-16).
This is necessary to test the line cards
locally.

3 Do a short (few seconds) bit error-test -no bit errors


with the SDH analyzer at the distributor
with payload 140MBit/s PRBS23.
*Minimum one channel per port. If using 3x34 or 1x140(coax), STM1 electric(coax) take every channel

Experimental arrangement

PC/Laptop computer

Q- F/ QB 3

10 dB
L L T
SN
i i
n n
e e

STM -1
NE
el

DDF

SDH Analyser

Field Acceptance Protocol Nokia Siemens Networks 82 (86)


PF2G5B IEEE 802.3 & RFC2544 Error Test
Description: This test gives the step to measure the RPR-functionality of the NE. The
following item will be tested:

Bit error , throughput and latency

Test equipment: Ethernet test set, LCT/NCT

Tested position:______________

Step Procedure Expected Result Result Comply


(Y/N)
Connect the NE via STM-64/STM-16 line no LOS alarm at appropriate
1 with the remote station. (see Experimental function unit
arrangement)

2 Configure the RPR similar to the Figure


Cross-connect PF2G5B 3 o'clock/9 o'clock at
3 remote station.
Do a quick RFC2544-measurement with the
4 ETH analyzer at the LAN-connector No packet loss and low latency

Reconfigure the RPR-node as required and


5 unplug the Measurement equipment. No alarm

Experimental arrangement

9 o'clock 3 o'clock
PF2G5

LCT

3 o'clock

Ethernet PF2G5

9 o'clock

PF2G5
3 o'clock 9 o'clock

Field Acceptance Protocol Nokia Siemens Networks 83 (86)


IF7FE2GEL2 Throughput, Latency and Frame Loss (RFC2544)
Test
Description: This test gives the step to measure the Ethernet-functionality of the NE.
The test is valid for IF7FE2GEL2 cards. The following items will be tested:

Frame Loss, throughput and latency

Test equipment: Ethernet test set, LCT/NCT

Tested position:______________

Step Procedure Expected Result Result Comply


(Y/N)
Connect the NE via STM-64/STM-16 line no LOS alarm at appropriate
1 with the remote station. function unit
Configure the Ethernet card and connect the
2 test set (Sub channeling must be disabled)
Enable the "internal loop back" function at Test set receives signal
3 the remote station
Do a quick RFC2544-measurement with the
4 ETH analyzer at the LAN-connector No packet loss and low latency

Reconfigure the Ethernet card as required


5 and unplug the measurement equippment. No alarm

Field Acceptance Protocol Nokia Siemens Networks 84 (86)


IF4FE4GE Throughput, Latency and Frame Loss (RFC2544)
Test
Description: This test gives the step to measure the Ethernet-functionality of the NE.
The test is valid for IF4FE4GE cards. The following items will be tested:

Frame Loss, throughput and latency

Test equipment: Ethernet test set, LCT/NCT

Tested position:______________

Step Procedure Expected Result Result Comply


(Y/N)
Connect the NE via STM-64/STM-16 line no LOS alarm at appropriate
1 with the remote station. function unit
Configure the Ethernet card and connect the
2 test set (Sub channeling must be disabled)
Enable the "internal loop back" function at Test set receives signal
3 the remote station
Do a quick RFC2544-measurement with the
4 ETH analyzer at the LAN-connector No packet loss and low latency

Reconfigure the Ethernet card as required


5 and unplug the measurement equippment. No alarm

Field Acceptance Protocol Nokia Siemens Networks 85 (86)


IFS10GBE Throughput, Latency and Frame Loss (RFC2544)
Test
Description: This test gives the step to measure the Ethernet-functionality of the NE.
The test is valid for IFS10GBE cards. The following items will be tested:

Frame Loss, throughput and latency

Test equipment: Ethernet test set, LCT/NCT

Tested position:______________

Step Procedure Expected Result Result Comply


(Y/N)
Connect the NE via STM-64/STM-16 line no LOS alarm at appropriate
1 with the remote station. function unit
Configure the Ethernet card and connect the
2 test set (Sub channeling must be disabled)
Enable the "internal loop back" function at Test set receives signal
3 the remote station
Do a quick RFC2544-measurement with the
4 ETH analyzer at the LAN-connector No packet loss and low latency

Reconfigure the Ethernet card as required


5 and unplug the measurement equippment. No alarm

Field Acceptance Protocol Nokia Siemens Networks 86 (86)