FIRE DETECTION SYSTEMS

HEAT DETECTORS

Fire Protection Systems


UniVario WMX5000 Heat Detector
The New Industrial Standard

Product Application + Advantages


The WMX5000 industrial heat detector
WMX5000 heat detectors are designed
+ Microprocessor-controlled monitoring of
detects a rise in temperature from a fire. to detect open flames which cause a the heat sensor, software and hardware.
Dramatic increases in temperature are also
sharp increase in temperature, e.g.:
+ Early fire detection with low risk of
detected, resulting in early fire detection. flammable liquids and gases false alarms.
The A1, A2, B and C response classes and

highly flammable plastics
+ Application-specific configuration of
the S and R indices according to the EN It is designed to be used in outdoor
signal processing.
54-5 can be configured on the WMX5000
as required.
and in indoor industrial environments.
+ Supervising typical disturbance variables
Potential areas of use:
using intelligent evaluation algorithms.
A microprocessor is included to analyze

the data.
Production halls
Painting facilities + High electromagnetic tolerance.
Constantly monitored alarm sensor.

Transformers + Different installation options.
The housing is rugged and specifically

Printing presses
Incinerating plants + High degree of protection (IP 67), oil-tight
impact and vibration-resistant.
designed for challenging industrial Machine tools
environments. Channel monitoring + Optional upgrades:
Process industry Communication module for use as a ring
Stainless steel heat sensor.

bus detector
A quick release mounting attachment
They can be used in ex-zones 2 and 22.
Relay module with floating contacts for
makes the WMX5000 well suited for disturbance and alarm
installation on ducts.
+ Comprehensive service options.
+ Stainless steel sensor.
Function

212
30 30
20 20
10 K/min
10 K/min
5 K/min 248
5 K/min
3 K/min
3 K/min
176 Upper limit, class C
Temperature in F (absolute)

Temperature in F (absolute)
Upper limit, class A1 212
1 K/min
1 K/min
140 WMX5000
WMX5000

176
Lower limit Lower limit
104

140
77 131

0 3.8 7.3 10 20 30 37.5 40 50 0 4.4 10 12.7 20 30 40


1.3 1.8 11.7 1.6 1.8 8.2
time in min time in min

Stipulated alarm range according to EN 54-5 class A1 Stipulated alarm range according to EN 54-5 class C

WMX5000 response behavior WMX5000 response behavior

The UniVario WMX5000 is an innovative The large power supply and an The threshold temperatures range
and intelligent fire detector. Due to its optional module UniVario KMX5000 RK from 32 oF (0 C) to 194 oF (90 C). The
modular design, it can be tailored to with relay contacts enable the stand- response class and differential and
meet the unique demands of individual alone mode and application in statical response can be programmed
applications based on a uniform platform. different danger alarm or control according to your needs.
units. Accessible connections and a standard
As the first heat detector suitable for
industrial use, the UniVario WMX5000 Because it requires minimal energy, clamp simplify installation of all
can be integrated into an Apollo bus ultra thin cables can be used and products.
system. Individual alarm identification multiple sensors can be placed along A service unit is available to simplify
and parameterization is made possible one line. configuration, diagnosis, function
due to the optional UniVario KMX5000 Converting from limit mode to ring checks and data archiving.
AP communication module. bus mode is achieved by simply
installatiing a communication module
there is no need to switch cables.

Technical Data
Type Features Response threshold Temperature Type of External Approval
range of protection display
operation

UniVario Sensor monitored function Response classes according to - 4 oF to 176 oF IP 67 Can be VdS G207090
WMX5000 EN 54-5 connected
Alarm/disturbance and function LED - 20 C to +80 C
A1, A2, B, C, D* EN 54-5 class
Optional upgrades: Indices according to EN 54-5 A1, A1S, A1R,
- Communication module S, R A2, B, C
- Relay module
Adjustable between the alarm ATEX zone 2/22
UniVario_03 05/2011

Can be configured according to your needs temperatures of 32 oF (0 C) and


FM approval
Service interface 194 oF (90 C) 221 oF* (105 C*)
Data storage with service unit

Power supply 7.6 V to 30 V DC

*Only the WMX5000 with single-hole installation Minimax USA LLC Tel. 888.882.0191
No. S 89201

Subject to technical modifications 4030 E. Quenton Drive Suite 112 Fax 480.553.5701
Mesa, AZ 85215 sales@minimaxfp.com
www.minimaxusa.com
FIRE DETECTION SYSTEMS
HEAT DETECTORS

Fire Protection Systems


UniVario WMX5000 Heat Detector FS
Heat Detector for High Temperature Ranges

Product Application + Advantages


WMX5000 FS heat detectors detect a
WMX5000 FS heat detectors are designed
+ Heat detector for a wide range of applica-
rise in temperature resulting from a to detect open flames which cause a tions in the industrial field with a response
fire and are specially designed for high quick increase in temperature, e.g.: temperature of up to 1562 F (850 C).
temperature ranges of up to 1562 F
(850 C).
flammable liquids and gases + Microprocessor-controlled monitoring of
highly flammable solids the heat sensor, software and hardware.
In addition to a maximum temperature

reading, a quick increase in temperature
Designed for use in heavy industrial
+ Early fire detection with low risk of false
environments with high temperatures. alarms.
can also be detected, resulting in early
fire detection. Potential areas of application:
+ Application-specific configuration of signal
Exhaust gas ducts processing.
Detection is carried out by a protruding

sensor under constant monitoring. Engine test blocks
Machine tools
+ Supervising typical disturbance variables
using intelligent evaluation algorithms.
A microprocessor monitors the sensor and

analyzes the data.
Fibreboard presses
Chemical production + electromagnetic tolerance.
High
All response classes and indices according
Drying systems + Different installation options.
to EN 54-5 can be configured on the
WMX5000 FS as required.
They can be used in ex-zones
+ Protruding heat sensor for flexible installation.
The casing is very rugged and specially

2 and 22.
+ High degree of protection (IP 67), oil-tight,
impact and vibration-resistant.
designed for application in heavy
industrial environments. + Optional upgrades:
Stainless steel heat sensor.
Communication module for use as a ring
bus detector
LCD display can be connected if necessary.
Relay module with floating contacts for
disturbance and alarm
+ Comprehensive service options.
Function
Sample application of a heat detector which can be adjusted to meet the requirements of a customer.
932 419
248
30
20
10 K/min
5 K/min
896 3 K/min 383

Temperature in F (absolute)
212
30
20
10 K/min
5 K/min
3 K/min
860 347
176
30 20
10 K/min Upper limit, class G
5 K/min
3 K/min Upper limit, class A1
824 1 K/min 1 K/min 311 WMX5000 FS 1 K/min
140
WMX5000 FS

788 Lower limit 275 Lower limit


104

752 77 239

0 10 20 30 40 50 0 10 20 30 40 50 0 10 20 30 40 50
time in min time in min time in min

--- WMX5000 FS response behaviour Stipulated alarm range according Stipulated alarm range according
at the threshold temperature of 435 C to EN 54-5 class A1 to EN 54-5 class G
--- WMX5000 FS response behaviour --- WMX5000 FS response behaviour

The UniVario WMX5000 FS is an The large range of power supply The protruding thermoelectric alarm
innovative, intelligent fire detector and an optional module with relay sensor can be mounted flexibly or as a
which, due to its modular concept, can contacts enable the stand-alone mode sensor rod.
be tailored to meet the unique demands and application in different danger
of individual applications based on a
The threshold temperatures and
alarm or control units. differential response can be configured
uniform platform.
Because it requires minimal energy, ultra according to specific requirements.
As the first high-temperature heat thin cables can be used and multiple
detector suitable for industrial use, the
The optional LCD display simplifies the
sensors can be placed along one line. function checks and monitoring operating
UniVario WMX5000 FS can be integrated
Converting from limit mode to ring bus conditions.
into an Apollo bus system becuase of
the optional UniVario KMX5000 AP mode is achieved by installing a A service device to simplify configuration,
communication module. Individual alarm communication module there is no diagnosis, function checks and data
identification and parameterization need to switch cables. archiving is available.
is therefore possible.

Technical data
Type Features Response threshold Temperature Type of External Approval
range of protection display
operation

UniVario High-temperature detector Response class according to -4 oF to 176 oF IP 67 Can be VdS G207091
WMX5000 FS EN54-5 connected
Protruding sensor, functions monitored A1, A2, B, C, D, E, F, G 20 C to +80 C EN 54-5 class
Indices according to EN 54-5 DS, GS
UniVario Alarm/disturbance and function LED S, R
WMX5000 FS 3GD ATEX zone 2/22
Optional upgrades: Adjustable between the alarm tem-
- Communication module ring bus peratures of 32oF (0 C) and 752 oF FM approval
- Relay module (400 C) (Special models up to 1562
oF, 850 C) with a service device
UniVario_04 05/2011

Can be configured according to your needs


Service interface
Data storage
Power supply 7.6 V to 30 V DC

Subject to technical modifications Minimax USA LLC Tel. 888.882.0191


No. S 89201

4030 E. Quenton Drive Suite 112 Fax 480.553.5701


Mesa, AZ 85215 sales@minimaxfp.com
www.minimaxusa.com
FIRE DETECTION SYSTEMS
FLAME DETECTOR

Fire Protection Systems


Flame Detector UniVario FMX5000 IR
Superior Triple View

Product Application + Advantages


The 3 channel flame detector FMX5000 IR
FMX5000 IR flame detectors are designed
+ Monitoring of the function of window,
evaluates the IR range of the optical to detect open flames that can be caused sensor, soft- and hardware controlled by
spectrum. by the combustion of solid or liquid microcontroller.
FMX5000 IR flame detectors meet the
materials (e.g. plastics, wood, gases, oil
products, etc.). + 3 channel infrared analysis with the highest
highest sensitivity class 1 in accordance response sensitivity.
with EN 54-10. Typical applications include:

+ Triple optical test monitors full function.
Fire-specific signals are digitally processed

by the microcontroller preventing false
Tank farm monitoring
Heating and coal-fired + High resistance to interference, due to
intelligent evaluation algorithms.
alarms (e.g. lightning). power plants
The detector window is monitored for

Motor test benches + Application parameter is set via DIP switch or
Large industrial plants service device.
optical integrity in the IR spectral range.
All 3 sensores are monitored separately.
Airplane and helicopter hangars
Chemical storages and + Special oil-tight, chemical-resistant and
silicone-free versions available.
The integrated microcontroller monitors
chemical production plants
the function of the detector. Faults are Fuel stores + Optional upgrades:
displayed on the detector and a signal is Pump stations Communication module for use as a ring
sent to the fire control panel. Print shops bus participant
Heavy-duty industrial housing for rough
Wood product industry Relay module with floating contacts for
industrial applications. disturbance and alarm
+ Various installation adapters available.
+ Comprehensive service options.
Function

As the first flame detector suitable


The large range of power supply and
The new, innovative housing design

for industrial use, the UniVario an optional module with relay is extremely robust, seawater-resist-
FMX5000 IR can be integrated into contacts enables the stand-alone ant and has an IP 67 rating. The
an Apollo bus system, due to the mode and application in different FMX5000 IR
optional UniVario KMX5000 AP danger alarm or control units. is made for the most extreme
communication module. This makes Because the FMX5000 IR requires

industrial application environments.
individual alarm identification and minimal energy, smaller cross section Due to measures taken on the

parameterisation possible. cables can be used and multiple housing and safety-oriented
A separate cable connection port
sensors can be operated on one electronic design, the FMX5000 IR
makes installation and maintenance detection line. flame detector exceeds modern EMC
easy and inexpensive. Converting from conventional type to

requirements.
ring bus mode is achieved by simply Failure signals are registered at

installing a communication module central position via a separate
theres no need to switch cables. current increasing line.
A service device to simplify configur

ation, diagnosis, function checks and
data archiving is available.
Analysis of internal history memory

by using the UniVarioView service
software.

Technical Data
Type Features Spectral Temperature Type of External Approval Monitoring
sensitivity range of protection display surface (VdS)
operation rel. to risk m 2

UniVario Alarm/disturbance and function LED 185 nm to 260 nm - 4 oF to 176 oF IP 67 Optional EN 54-10 class 1 max. 7,273 ft. sq.
FMX5000 IR (676m)
Optional extras: - 20 C to +80 C VdS G209141
Communication module
FM 3036782 Room height
Relay module
max. 147 ft.
Can be configured according to your needs (45m)
Service interface
UniVario_05 04/2010

Data storage
Power supply 7.6 V to 30 V DC

Subject to technical modifications Minimax USA LLC Tel. 888.882.0191


No. S 89201

4030 E. Quenton Drive Suite 112 Fax 480.553.5701


Mesa, AZ 85215 sales@minimaxfp.com
www.minimaxusa.com
FIRE DETECTION SYSTEMS
FLAME DETECTORS

Fire
FireProtection
ProtectionSystems
Systems
UniVario Flame Detector FMX5000 UV
The Watchful Eye

Product Application + Advantages


The FMX5000 UV flame detector evaluates
FMX5000 UV flame detectors are + Monitoring of the function of window,
the UV range of the optical spectrum. designed to detect open flames sensor, software and hardware con-
FMX5000 UV flame detectors meet the
caused by the combustion of solid or trolled by microcontroller.
highest sensitivity (class 1) in accordance liquid materials (e.g. plastics, wood,
metals, gases, oil products, etc.). + Maximum response sensitivity.
with EN 54-10.
Typical applications include: + High resistance to interference, due
Fire-specific signals are digitally pro-
to evaluation algorithms.
Tank farm monitoring
cessed by the microcontroller preventing
false alarms (e.g. lightning). Heating and coal-fired power plants + Application parameter is set via DIP
Motor test benches switch or service device.
The detector window is monitored for

optical integrity in the UV spectral range.
Large industrial plants
Airplane and helicopter hangars
+ Specific customer evaluation algorithms
possible for special applications.
Chemical storages and chemical
The integrated microcontroller monitors

the function of the detector. Faults are production plants + Special oil-tight, chemical-resistant and
Fuel stores silicone-free versions available.
displayed on the detector and a signal is
sent to the fire control panel. Pump stations
Magnesium dry treatment (milling)
+ Optional upgrades:
Communication module for use as a ring
Heavy-duty industrial housing for rough
Print shops bus participant
industrial applications. Wood product industry Relay module with floating contacts
for disturbance and alarm
+ Various installation adapters available.
+ Comprehensive service options.
4.92 ft
Function
1.64 ft

0.11 ft 0.29 ft 1.08 ft 5.38 ft


24.6 ft
41.0 ft
82.0 ft
164.0 ft

As the first flame detector suitable for The large range of power supply and an The new, innovative housing design is
industrial use, the UniVario FMX5000UV optional module with relay contacts enable extremely robust, seawater-resistant and
can be integrated into an Apollo bus the stand-alone mode and application in has an IP 67 rating. The FMX5000 UV is
system, due to the optional UniVario different danger alarm or control units. made for the most extreme industrial appli-
KMX5000 AP communication module. This cation environments.
makes individual alarm identification and
parameterization possible. Because the FMX5000 requires minimal
energy, ultra thin cables can be used and Due to measures taken on the housing
multiple sensors can be placed along one and safety-oriented electronic design,
A separate cable connection port makes line. the FMX5000 UV flame detector exceeds
installation and maintenance easy and modern EMC requirements.
inexpensive.
Converting from limit mode to ring bus
mode is achieved by simply installing a Failure signals are registered at a central
communication module there is no need position via a separate current increasing
to switch cables. line.

Technical data
Type Features Spectral Temperature Type of External Approval Monitoring
sensitivity range of protection display surface (VdS)
operation rel. to risk m 2

UniVario Alarm/disturbance and function LED 185 nm to 260 nm -4 oF to 176 oF IP 67 Can be VdS G206132 max. 7,273 ft. sq.
FMX5000 UV connected (676m)
Optional upgrades: 20 C to +80 C EN 54-10 class 1
UniVario_01 04/2010

Communication module Room height


Relay module FM 3030815 max. 147 Ft.
Can be configured according to your needs (45 m)
Service interface
Data storage
Power supply 7.6 V to 30 V DC

Subject to technical modifications Minimax USA Incorporated Tel. 888.882.0191


No. S 89201

4030 E. Quenton Drive Suite 112 Fax 480.553.5701


Mesa, AZ 85215 sales@minimaxfp.com
www.minimaxusa.com
FIRE DETECTIONS SYSTEMS
COMMUNICATION MODULE

Fire Protection Systems


The UniVario KMX5000 RK
Relay Module

Product Application + Advantages


The UniVario KMX 5000 RK Relay
Integration in all UniVario detectors.
+ Directly integrated into the detector base
Module is a communication module without need for any separate cabling.
for the operation of UniVario detectors
independent of fire detection systems. Typical areas of application:
+ Retrofitting possible at any time.
- stand-alone operation + Large supply voltage range.
One potential-free contact each for fault
- hazard alert systems + Large conductor sizes.
messages and fire alarm. - fire detection systems
- use in combination with building
management systems
- integration in machine tool
controls
- processing industry
- wind energy plant
Function

Application with Relay Module

FMZ 5000

Relay Module KMX5000 RK The KMX5000 RK communication module Materials Provided


Communication module for the operation is made to fit into the base of the UniVa- KMX5000 RK relay module
of UniVario detectors either in fire detec- rio MX5000 detector. Short-circuiting bridge
tion systems or independent of them. Fastening material
Product Features
Potential-free contacts for alarm and Potential-free change-over Connection/Installation
fault signals allow installation either as a contacts for alarm and fault Cross-section of connecting cable
stand-alone detector, within fire detection signalling min. 0.5 mm
systems/hazard alert systems or as part of max. 2.5 mm
building management systems. Integration into the base of the
UniVario detectors

Technical data
Connection 6-pole flex conductor
Operating Voltage 24 V (14 V 29 V) DC
Operating current only KMX5000 RK
(without detector current):
normal operation, fault relay on approx. 20 mA at 24 V
alarm and fault relay on approx. 30 mA at 24 V
alarm and fault relay off approx. 07 mA at 24 V
V oltage load contacts max. 60 V DC, 25 V AC
Current load contacts max. 1 A
Operating temperature -4 oF to 176 oF (20 C to +80 C)
Relative humidity (IEC721-3-3) 5 to 85% no condensation
UniVario_02 05/2011

Specification to EN 54 part 18
Weight 1.76 oz. (50 g)
Dimensions in Inches 2.52 x 0.94 x 2.24 (L x W x H)

Subject to technical modifications Minimax USA LLC Tel. 888.882.0191


No. S 89201

4030 E. Quenton Drive Suite 112 Fax 480.553.5701


Mesa, AZ 85215 sales@minimaxfp.com