Beruflich Dokumente
Kultur Dokumente
Vertical Reinforcement
Horizontal Reinforcement
Parameters:
Footing:
Width of Footing, B = 1.1 m
Thickness of Footing, t = 0.3 m
Concrete Unit Weight = 24 kN/m^3
Soil:
Soil Unit Weight = 18 kN/m^3
Coefficient of Friction = 30 deg
Cohesion = 0 Kpa
Allowable Bearing Capacity 75.2 Kpa
Soil Height = 1.4 m
CHB Wall:
Wall Height, Hc = 2.5 m
Wall thickness, tc = 0.15 m
CHB Unit Weight = 21.2 kN/m^3
Loadings:
Wind Load, pl = 1.63 kPa
Seismic Load, pe = 1.17 kPa
Load Computations:
Due to Earth Pressure
Coeff. Of Active Earth Pressure = 0.333333
Kv 0 8.530766
Kh 0.15
Active Earth Force = 5.88 kN
Active Earth Force (Seismic) = 7.637032 kN
Kv 0 8.530766
Kh 0.15
Passive Earth Force = 52.92 kN
Passive Earth Force (Seismic) = 150.4827 kN
Weights:
Weight of CHB Wall = 11.448 kN
Weight of Footing = 7.92 kN
Weight of Soil = 18.81 kN
Rv = Total 38.178 kN
With Tension!
Rv 6e
qmax 1 qmax. = 0.00 75.20 kPa
B B
Reinforcement Design:
Shear Check:
Width of footing considered, 1.00 m
Thickness of footing, t 0.30 m
Effective depth, d 207 mm
1
Vu fc ' b d
6
134.38 kN > 53.45 kN Ok!