REPORT OF THOROUGH EXAMINATION


STATUTORY INSTRUMENTS 1998 NO. 2307
The Lifting Operations and Lifting Equipment Regulations 1998
STATUTORY INSTRUMENTS 1992 NO. 3073
The Supply of Machinery (Safety) Regulations 1992
STATUTORY INSTRUMENTS 1998 NO. 2306
The Provision and use of Work Equipment Regulations 1998
Factories Act CAP.126 L.F.N 1990
Report No. Date of Test/Examination Tester/Examiner Qualifications

99436 25/06/2017 JAPHET OMEFE FID, LEEA PART 1, NDT LEVEL II MT, PT &
UT
Identification Number Qty Description of Equipment TARE SWL Proof Date of next
WT GROSS Load Examination
WT Applied

GAS RACK

AL-SIL-08 1 A steel construction Gas Rack in 0.39 0.60 0.99 N/A 24/12/2017
dimensions 0.92m X 0.63m X Tonnes Tonnes Tonnes
2.01m (Length X Width X Height)
c/w 4 lifting points. 6.89
Sling#: tonnes
1set Fitted with 16mm X 1.5m X 4
SISL-098 @
Legged Wire Rope Sling c/w Quad
Master Link with ferrule secured 0-90o
Shackle #: thimble eyes all ends.
4.75
S1, S2, S3, S4 4pcs Bow Safety Pin Shackle tonnes
Comment: Back load item to onshore for load test
SPECIFICATION : BS 7072, BS 6210, BS 3032 TEST PROCEDURE: JOP-043
MPI METHOD: Wet Visible CONTRAST MEDIA: White Contrast Aid
PARTS EXAMINED: Four Lifting Points and Entire Body INDICATOR: Black Magnetic Ink
RESULTS: No defect as at the time of inspection. Fit for use

Name and address of equipment owner: Address of premises where Test / Examination was held:

STEVE INTERGRATED FSO UNITY


We hereby certify that on 25/06/2017 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for
use.
Signature of Inspector: Name of Inspector: JAPHET OMEFE
Conducting Examination Conducting: Examination only

Revision No: A02 Effective Date: 28th February 2017 Frm No: JCI-CERT-VMPI-RPT-001

Cert. No. 227174