Beruflich Dokumente
Kultur Dokumente
Reliable,
Efficient
and Quiet
The Compact Mini-Therm TM
Mini-Therm Features
Burner
• Optional circulating pump
• Easy to install
The Right Solution for Home Heating Systems
Mini-Therm JV
Extremely popular with that 2-Stage firing allows the unit
homeowners, JVT & JVS models to match the heating load
offer a new attractive and easy-to- requirement, reducing short-
service jacket. Well-known for cycling in homes that have small
their economy, both models come heating zones that don’t require
with a built-in draft diverter and the full boiler capacity… another
automatic vent damper to stop way to save energy.
your valuable fuel payments from
JVT & JVS Features:
disappearing up the chimney in
wasted heat. • Standing pilot (JVT) or
intermittent spark (JVS) ignition
• Up to 84.4% AFUE
JVT-standing pilot ignition models
use single-stage, on/off firing • Single stage on/off & 2-Stage
modes for all six sizes. JVS-spark (50 & 75), but offer energy saving firing modes
ignition models also use the on/ “Low/High” firing for sizes 100, • Sleek jacket removes easily for
off mode for the two smaller sizes 125, 160 & 225. The advantage is quicker service
JVT Input JVT JVS Heat Capacity Net IBR JVT JVS
JVS BTU/h Firing Firing BTU/h BTU/h
Size x 1000 kW Mode Mode x 1000 kW x 1000 kW AFUE % AFUE %
50 50 14.6 On/Off On/Off 42 12.3 36.5 10.7 80.2 84.4
75 75 21.9 On/Off On/Off 63 18.5 54.8 16.1 80.5 84.0
100 100 29.1 On/Off 2-Stage 84 24.6 73.0 21.4 80.7 82.0
125 125 36.6 On/Off 2-Stage 105 30.8 91.3 26.8 80.7 81.9
160 160 46.8 On/Off 2-Stage 134 39.3 116.9 34.3 81.0 80.2
225 225 65.9 On/Off 2-Stage 189 55.4 164.3 48.1 81.5 81.8
Mini-Therm JVi
Mini-Therm JVH uses an H.S.I. (hot JVH Features:
surface ignition system) to
• Hot surface ignition system
operate all six sizes in single-
stage, on/off firing modes. The • Up to 83% AFUE
boiler is equipped with a draft • Single-stage on/off firing mode
blower that permits side-wall or
• Induced draft system with
chimney venting. Compact models
gravity operated vent damper
are also easy to install, operate
and maintain.
In (Return)
PRV
B Front 9-1/4 7 C Out (Supply) 23-5/8
24 18
T&P Gauge 60
Left Top
Dimensions shown in
inches cm.
E
A
Dimensions Approx.
JVT A B C D E F V Water Gas Weight
JVS Conn. Conn.
Size inches cm inches cm inches cm inches cm inches cm inches cm inches cm in. in. lbs. kg
50 13-3/8 34 27-3/4 71 23-5/8 60 21-3/4 55 26-1/2 67 18 46 4 10 1-1/4 1/2 120 54
75 13-3/8 34 27-3/4 71 24-1/8 61 21-3/4 55 27-1/2 70 18 46 5 13 1-1/4 1/2 126 57
100 16-7/8 43 28-3/4 73 24-1/8 61 22-3/4 58 27-1/2 70 18 46 5 13 1-1/4 1/2 134 61
125 16-7/8 43 28-3/4 73 23-5/8 60 22-3/4 58 27-1/2 70 18 46 6 15 1-1/4 1/2 138 63
160 20-3/8 52 28-3/4 73 23-5/8 60 22-3/4 58 27-1/2 70 18 46 6 15 1-1/4 1/2 164 74
225 25-5/8 65 31-1/2 80 23-1/4 59 24-3/4 63 27-1/2 70 20 51 7 18 1-1/4 1/2 181 82
Mini-Therm JVi
Front Right