Sie sind auf Seite 1von 5

Crowcon Detective Transportable Gas Monitor

Crowcon's Detective is the perfect


choice for a transportable multiple gas
detection temporary network...
Crowcon Detective is the unique solution to temporary
gas detection installation, ideally suited to shut downs or
other short-term operations. Detective's innovative design
allows a multi-gas detection system to be in place on
potentially hazardous sites within minutes. This gas leak
detection instrument is highly effective for confined
spaces, sewers and tunnel applications. Based on the
highly acclaimed Triple Plus, Detective operates from
internal rechargeable batteries and can be placed in
operation immediately without the need for power or other
infrastructure. A single Detective can detect up to four
different gases. A great feature of this versatile gas
detector is that it can be linked together with other units to
protect larger areas.
Crowcon Detective
Detective Features... Transportable Multi-Gas
Monitor

Easy to set up and use, put into place and switch on Call for Price $
FREE U.S. Shipping
Audible and visible confidence blip assure user of 1-800-551-8544
correct functioning
Up to 4 gas measurement channels displayed
simultaneously provide easy tracking of multiple
hazards
Fully flexible with interchangeable sensors
Extremely loud 101dBA @1m audible alarm
Bright visual alarm with flashing cluster LEDs
Tripod frame allows safe operation on uneven
ground
Lightweight and stackable with detachable legs
Under body sensors protected from dirt and moisture
Sealed lead acid battery pack provides 24 hours of
continuous use
Intrinsically safe
Protected against water and dust ingress to IP65
standard
Allows for easy tracking of multiple hazards

Crowcon Detective is specially designed to provide a


standalone temporary gas monitoring system. Connect
wire from one unit to the next. An alarm signal from any
one unit travels to the others through the wire to trigger an Link multiple Detectives together.
alarm on all connected Detectives. A unit where the alarm
originates shows a faster LED flash, allowing personnel to
readily identify where the hazard is detected. Data is
internally logged and saved for later PC download. Fully
charged batteries enable each Detective to operate an
entire 24 hour shift before recharging. When in use, sturdy
water and shock resistant construction keeps Detective
fully protected even if the unit is overturned. And when its
time to go, the lightweight stackable configuration makes
the Detective easy to transport.
Detective Specifications...
Weight 8.5 kg (19lb)

Dimensions 660 h x 380 w x 380 d mm


(26 x 15 x 15 inches)

Typical Measuring Ranges Standard Range Typical Alarm


and Alarm Settings Levels

(up to four gas measurement Flammable 0-100% LEL 20%


channels) LEL

Oxygen 0-25% 19%23%

Hydrogen Sulphide 0-50ppm 10ppm

Carbon Monoxide 0-500ppm 30ppm

Sulphur dioxide 0-10ppm 2ppm

Chlorine 0-5ppm 0.5ppm

Nitrogen dioxide 0-50ppm 2ppm

Phosphine 0-2000ppm 0.5ppm

Ammonia 0-50ppm 25ppm

Hydrogen 0-2000ppm -

Hydrogen cyanide 0-25ppm 10ppm

Hydrogen chloride 0-10ppm 5ppm

Ozone 0-1ppm 0.5ppm

Other sensors available


Other ranges and alarm levels available

Typical Alarm Response Methane 20 s, Oxygen 10 s, Typical Toxic Gas 20 s.


Time

Expected sensor life Flammable 5 years, Toxic 3 years, Oxygen 2 years.

Audible Alarm Wailing, omni-directional siren, 101 dBA @ 1 meter.


Confidence blip (selectable).
Continuous tone for low battery.

Visible Alarm Four large, top-mounted red LED clusters and single red LED on control
panel.
In alarm mode LED clusters flash in pairs in quick succession and control
panel LED lights on those Detectives sensing the hazard.
LED clusters of linked Detectives repeating the alarm, flash more slowly.
Slow flashing green LED indicates normal working.
Rapid flashing green LED indicates low battery.

Display 2 lines of 24 characters, dot matrix high contrast LCD with back light
operating for 30 minutes.
Values and units for up to 4 gases displayed simultaneously at current,
TWA or peak levels.
Low battery, real time and elapsed time, calibration and configuration
data also displayed.

Datalogging Adjustable sample rate, 100 hours @ 1 minute sample rate (maximum
6000 data points per channel), logging of events, user and site.

Battery 6 V, 4.8 Ah Sealed lead acid battery pack

Battery Life Standard instrument 12 hours.


Pumped instrument 8-10 hours.

Battery Charging Built-in battery charging circuit, dual rate


Input 100 - 250 V ac (Safe Area operation only)
Typical charge time: 5 - 6 hours

Operating temp. range -20C to +50C (-4F to 122F).


Humidity 0 95% RH non condensing.

Approval Codes

Europe ATEX II 2G EEx ibd IIC T4

USA Class 1 Division 1, Groups A, B, C, D

Safety Standards

Europe EN50014, EN50020, SFA3009

USA & Canada CSA 22.2

Ingress protection IP65

RF radiation tested to EN55022 class B and meets EN50081-2

RF immunity tested to IEC801-3 and meets EN50082-

PC Interface Detective has an in-built PC interface, which can be connected to the


serial port of a computer using the RS232 lead. The PC software
Crowcon's 2000 can be used to set alarms, clock, datalogging interval
and password. Crowcon's 2000 also controls datalogging, giving the
user a datafile compatible with all leading spreadsheets.

Auto Calibrator Detective can be routinely calibrated quickly and simply using
Autocalibrator. The internal pump of Autocalibrator handles up to five
gases. A PC interface provides easy access with optional datalogging for
proof of calibration.

Accessories Baffle plate (to protect sensors)


Interconnecting lead - 10 m standard
Computer lead - RS232 serial link
Aspirator
Manual bulb and 2 m hose, both
non-absorbent and hydrocarbon
resistant, 1 m probe, water trap and
extra hose available

Power Adapters Plug in charging power supplies are available in UK, European or US
style. In line versions for 110V or 230V AC have flying lead for fitment
of suitable mains plug. A vehicle lighter socket charger is available.

Optional Accessories universal harness plate, shoulder strap, chest harness, carry case,
aspirator assembly (flow plate bulb and 2m/6ft tubing), fixed and
telescopic sample probes, and an in-line water trap.