Sie sind auf Seite 1von 3

Radiometric level measurement Working Principle Instrumentation Tools Page 1 of 3

About contact us Disclaimer Copyright Subscribe Submit Articles Sponsor Search


TOOLS

ANIMATION BASICS MEASUREMENT CONTROL SYSTEMS Q&A ELECTRONICS ELECTRICAL DESIGN

TOOLS
Ads by Google Measurement RF Radio Metric Conversion Metric Gauge

ANIMATION LEVEL MEASUREMENT

Radiometric level measurement Working Principle


August 7, 2016 S Bharadwaj Reddy Leave a comment

Facebook Twitter Google+ LinkedIn

YOKOGAWA
Transmitter

Get Google
Chrome

The radiometric level measurements work non-contacting and non-intrusive. As the components are mounted on the outer wall,
they do not come into contact with the measured material and are therefore not exposed to wear and tear.

http://instrumentationtools.com/radiometric-level-measurement-working-principle/ 10/22/2016
Radiometric level measurement Working Principle Instrumentation Tools Page 2 of 3

Gamma radiation, emitted from a shielded source is attenuated as it passes through the vessel. This attenuation is measured by a
TOOLS
highly sensitive detector, mounted at the opposite side of the vessel. As type of radiation and measuring geometry are constant
the attenuation will only be affected by a change in level.

The continuous measurement of level uses a radiation field over the whole measuring range. If the level rises within the range of
the radiation field, the attenuation becomes stronger and consequently the detector measures less radiation. In this manner, the
level can be reliably monitored irrespective of pressure, temperature, viscosity, color and all chemical properties.

There are different possibilities how a radiation field is formed. Either a rod detector or a rod source is used; sometimes it is most
beneficial to use both in combination.

Advantages

Highly accurate and reliable


No wear and tear T
No maintenance required at any time
Unaffected by temperature, pressure, dust, colour, conductivity or chemical properties of the measured material
Universally applicable on all kinds of vessels, without modification of the plant

Disadvantages

Radiation Sources used for level measurement.

SHARE Facebook Twitter Google+ LinkedIn

YOKOGAWA Transmitter

Author

S Bharadwaj Reddy
Instrumentation Professional Working in a reputed Oil & Gas Company.

4-20mA Graphical Calculations How to do 4-20mA Conversions Easily


D

Related Articles

CALIBRATION LEVEL MEASUREMENT LEVEL MEASUREMENT SWITCHES


Level Transmitter Calibration Procedure RF Level Switches Working Principle
September 24, 2016 September 24, 2016

ANIMATION BASICS LEVEL MEASUREMENT


How a 4-20mA Transmitter Works ? Remote Seal Differential Pressure
September 16, 2016 Transmitters Principle
September 13, 2016

http://instrumentationtools.com/radiometric-level-measurement-working-principle/ 10/22/2016
Radiometric level measurement Working Principle Instrumentation Tools Page 3 of 3

TOOLS

Leave a Reply
Your email address will not be published. Required fields are marked *

Comment

Name *

Email *

Website

Post Comment

Copyright 2016. Created by Bharadwaj.

http://instrumentationtools.com/radiometric-level-measurement-working-principle/ 10/22/2016

Das könnte Ihnen auch gefallen