Beruflich Dokumente
Kultur Dokumente
1500
2000
13500 2000
T1 T2 1.8 M HIGH CHAIN
V V GENTS LINK FENCING
HSD MS D.P SWITCH ELECTRIC
TOILET
20KL 20KL OFFICE ROOM
3500
4.0X1.75M
1500 EV. SALES
EF. LADIES ROOM 3.5X2.5M
COUNTER
0 TOILET 3.0X3.5M
00 4.0X1.75M 3.0X3.5M
4 AUTOMATION
R4000
8000
R ROOM
3.5X2.5M
ATM/NFR
ROOM
3.5X3.0M
3500 5050
0
00
00
R1
R1
00 WITHIN 100 M
00
0 N.H.- 37
28
90
GRE
7
E
NER
G
Y
YRE NEE R
17457
35804 SITE FOR NEW RETAIL OUTLET
40
17
8
WITHIN 100 M WITHIN 100 M
70
LAND OF DEEPAK BORA 78 LAND OF HAREN CHUTIA
627
AIR COMPRESSOR 35
5
587
55807
90
4000
587
55807
90
1400
22073 3600 16839 TOTAL AREA=
MPD FOR MS HSD 2348.03 SQM
2X4X2
RIGHT OF WAY LINE RIGHT OF WAY LINE
300 MM SURFACE 49000
GRE
DRAIN
17000
9000
7600
21000
E
NER
26000
Y
4000 4000
2 NOS OF DCP TYPE R1
7000
00
FIRE EXTINGUISHER 00
0
1400
ON EACH PUMP BASE
TO SIBSAGAR TO JORHAT
0
00
21000 3600 20058 C/L OF NH 37
00
R1
4000
CANOPY SIZE MPD FOR MS HSD
17.0 X 8.0 M 2X4X2
8000
G
WITHIN 100 M
YRE NEE R
14500
HOARDING
9.0 M HIGH
YARD LIGHT
SITE PLAN
SCALE 1:1000
3000
BUFFER STRIP
800
49000
LAND DETAILS :-
3000
DAG NO :- 781 / 793 / 767
PATTA NO :- 151 (NEW)
VILLAGE :- CHANGMAIGAON
MOUZA :- LAHING
REVENUE CIRCLE :- TEOK REVENUE CIRCLE
400
P.O. & P.S. :- TEOK
21000
DIST :- JORHAT
PIN :- 785112 FRONT ELEVATION OF SALES BUILDING
SCALE 1:100
26000
R1
10 0
00 1 00
R1 NOTES :
1. E.V = VENT PIPES 2.00 M HIGH ABOVE ROOF SLAB AND END COVERED WITH
2 LAYERS OF BRASS WIRE GAUGE 11 MESH PER LINEAR CENTIMETER.
2. F=FILL POINTS FITTED WITH CAM LOCK COUPLING AND AIR TIGHT THREADED BRASS
CAP FOR DECANTING FROM TANK LORRY.
3. D=DIP PIPES WITH CAP ASSEMBLY.
133
4. ALL ELECTRICAL FITTINGS ARE FLAME PROOF CONFORMING TO I.S :2148.
5. ALL DOORS OF BUILDING TO BE OPENED OUTWARDLY.
6. NO SEWER OR SURFACE DRAIN WITHIN 6M OF THE U/G TANK &D/U.
942 994 7. PREMISES TO BE USED FOR ONLY STORAGE OF PETROLEUM PRODUCTS.
115
767
8. TANKS ARE PAINTED WITH TWO LAYERS OF HOT BITUMEN OVER TWO COATS
1500
ROAD FLANK ROAD FLANK 114 OF RED LEAD PRIMER TO PROTECT AGAINST CORROSION.
912 36 38 9. FABRICATION DESIGN OF UNDER GROUND STORAGE TANK ARE CONFORMING
110
TO AS PER C.C.E NAGPUR ORDER NO.P.6(3)51 DATED 04.05.2006.
205 34 10. ALL DIMENSIONS ARE IN M.M. UNLESS OTHER WISE NOTED.
TO JORHAT 43 11. S.B- FIRE EXTINGUISHER 2 NO'S FOR EACH PUMP AS PER EXPLOSIVE RULES-2002.
23
NH-37 12. F.E - FIRE EXTINGUISHER 2 NO'S FOR EACH PUMP AS PER EXPLOSIVE RULES -2002.
13. TANK SHOULD BE GIVEN HYDRAULIC PRESSURE TEST PRIOR TO INSTALLATION
7000
MOUZA MAP AND BEFORE ANY PROTECTIVE COATING AS APPLIED.THE TEST SHOULD BE
TO SIBSAGAR (NOT TO SCALE) MAINTAINED AT A CONTROLLED PRESSURE OF 0.36 KG/SQ.C.N.FOR 2 HOURS.
C/L OF NH 37 14. DIP ROD SUPPLIED WITH THE TANK FOR THIS TYPE OF INSTALLATION
SHOULD BE 3280 LONG INSTEAD OF STANDARD 2350 MM.
15. FABRICATION THICKNESS OF SHELL PLATES AN END PLATES OF TANKS:
20KL-SHELL-6 MM
1500
STEEL BUILT UP
EARTH FILLING SAND FILLING NAME OF APPLICANT: SR. DIVISIONAL RETAIL SALES MANAGER
COLUMN WITH ALUMINUM LINEAL/
FRP COLUMN ALIPHATIC WHITE
400 400 CLADDING AND POLYURETHANE PROJECT: MS & HSD FILLING STATION
600 600
PVC RWP WITIN. FALSE CEILING.
HOLDING DOWN
AGENCY: NEW R.O. AT CHANGMAI GAON
6000
BRACKETS
DIA
DIA
LOCATION:
CHECKED BY :-
PUMP VILLAGE / TOWN : CHANGMAI GAON
DCP TYPE FIRE
EXTINGUISHER DISTRICT : JORHAT
PUMP BASE
FIRE FIRE
STATE : ASSAM
DRIVE WAY LEVEL DRIVE WAY LEVEL SCALE: 1:200 DATE: 12/05/2016 APPROVED BY:-
P.C.C.SOLING(1:3:6) P.C.C.SOLING(1:3:6) 3600
6 @ 90 C/C 6 @ 300 C/C BOTHWAYS
265 THK. RCC MAT RAFT JOB NO: DG/51
265 THK. RCC MAT RAFT 12 @ 140 C/C FRONT ELEVATION OF CANOPY
SCALE 1:100 DRG. NO: TDO/2016-17/01
INSTALLATION AND OTHER DETAILS OF U/G TANKS IN EARTH PIT DIVINE GRACE
AUTOCAD BY:
SCALE :- 1:80 GUWAHATI -06