Sie sind auf Seite 1von 7

Job Number Sheet

DSU-2017-025
Job Title
DSU - Kenya Operational Hub (KEOH)
Solar Installation For National Blood bank South Sudan
Client
UNOPS Building, UN lane, off UN Avenue Republic Of South Sudan
P.O Box 783, Village Market, 00621. Nairobi Calcs by Checked by Date
ARNOLD T PHILIP M 14/09/2017
Truss 1 Holding-down Bolt Design - Eurocode 3 - 2005
Material Strength Properties
fcu : 20 MPa
fu Bolt : 400 MPa
Bolt Grade : 4.6
Bolt fy : 240 MPa
Bolt fu : 400 MPa
fy Baseplate : 200 MPa
fu Baseplate : 200 MPa
fy Column : 200 MPa
fu Column : 200 MPa
tu Weld : 500 MPa

Column Section
S1

BasPlate Design Data:


Plate Shape : Rectangular
Height : 250 mm
Breadth : 250 mm
Thickness : 4 mm

Weld Properties
Size :6 mm Fillet Weld

Bolt Properties
Diameter : 16 mm
Achor Length : 200 mm
Compression not allowed in bolts

Bolt End Plate Properties


End Type : Square Plate
Dimension : 20 x 20 mm
Thickness : 5 mm

Bolt Resistance Forces


Bolt Netto Cross Section

0.75 . . d 2
An =
4
0.75 16 2
=
4
= 150.796 mm2

Tension Resistance Table 3.4


Job Number Sheet
DSU-2017-025
Job Title
DSU - Kenya Operational Hub (KEOH)
Solar Installation For National Blood bank South Sudan
Client
UNOPS Building, UN lane, off UN Avenue Republic Of South Sudan
P.O Box 783, Village Market, 00621. Nairobi Calcs by Checked by Date
ARNOLD T PHILIP M 14/09/2017

k 1. A n. f u
Tr =
Ym2. 1000
.9 150.8 400
=
1.25 1000
= 43.430 kN

Tension Resistance Concrete DD_CEN_TS_1992-4-2 6.2.5(1)

k cr . f ck. hef 1.5


NRk =
1000
7.7 20 200 1.5
=
1000
= 97.398 kN

6 . (A_end - A_bolt ). f ck. Yucr


NRk =
1000
6 (400 - 201.06 )20 1
=
1000
= 23.873 kN

Shear Resistance Table 3

0.6 . An. f u
Vr =
Ym2. 1000
0.6 150.8 400
=
1.25 1000
= 28.954 kN

Shear Resistance 6.2.2 (7)

(0.44 - 0.0003 . f yb). f ub. As


Vr =
Ym2. 1000
(0.44 - 0.0003 240 )400 150.8
=
1.25 1000
= 17.758 kN

Compression Resistance 13.3.1


Job Number Sheet
DSU-2017-025
Job Title
DSU - Kenya Operational Hub (KEOH)
Solar Installation For National Blood bank South Sudan
Client
UNOPS Building, UN lane, off UN Avenue Republic Of South Sudan
P.O Box 783, Village Market, 00621. Nairobi Calcs by Checked by Date
ARNOLD T PHILIP M 14/09/2017

0.9 . An. f u
Cr =
1000
0.9 150.8 400
=
1000
= 54.288 kN

Find Effective Compression Area


Effective Distance from Edge of Section

f yp
cMax = tp.
2
3 . . f ck. Ym0
3
200
= 4
2
3 20 1
3
= 8.944 mm
Job Number Sheet
DSU-2017-025
Job Title
DSU - Kenya Operational Hub (KEOH)
Solar Installation For National Blood bank South Sudan
Client
UNOPS Building, UN lane, off UN Avenue Republic Of South Sudan
P.O Box 783, Village Market, 00621. Nairobi Calcs by Checked by Date
ARNOLD T PHILIP M 14/09/2017
Calculation Sheet for Load Case : 1
Factored loads
P: 64.34 kN
Vx : 4.91 kN
Mx : 1.17 kNm

Find Equilibruim
The actual number of Grid Point used for calculation is 1020

Moment balancing
Job Number Sheet
DSU-2017-025
Job Title
DSU - Kenya Operational Hub (KEOH)
Solar Installation For National Blood bank South Sudan
Client
UNOPS Building, UN lane, off UN Avenue Republic Of South Sudan
P.O Box 783, Village Market, 00621. Nairobi Calcs by Checked by Date
ARNOLD T PHILIP M 14/09/2017
Sum Of Moments around X-axis = 0.1 kNm
Sum Of Moments around Y-axis = 0.0 kNm

Axial Force balancing


Sum Of Forces in Y-direction = 1.3 kN

The Shear Resistance in the Bolts Resists the Following Forces:


Forces in X-direction
Moments around Y-axis
Forces in Z-direction

Calculating Factors of Concrete

StrainMax
FOS =
Strain
.0035
=
.00037
= 9.459

Calculating Factors of Safety in Critical Bolt


Tension in Bolts
Critical Bolt Tension

Tr
FOS =
Tension
43.429
=
.61248
= 70.907

Critical Bolt Pull-Out

Trc
FOS =
Tension
29.904
=
.61248
= 48.824

Shear in Bolts
Critical Bolt Shear
Job Number Sheet
DSU-2017-025
Job Title
DSU - Kenya Operational Hub (KEOH)
Solar Installation For National Blood bank South Sudan
Client
UNOPS Building, UN lane, off UN Avenue Republic Of South Sudan
P.O Box 783, Village Market, 00621. Nairobi Calcs by Checked by Date
ARNOLD T PHILIP M 14/09/2017

Vr
FOS =
Shear
28.953
=
1.2275
= 23.587

Shear and Tension combined in Bolts


The factor should be less than 1.0 for bolts in shear and tension

The bolt number 3 has the critical shear and tension combination

The tension in the bolt is: 0.61 kN


The shear in the bolt is: 1.23 kN

Tension and Shear Resistance Table 3

Shear Tension
f actor = +
Vr 1.4 . Tr
1.2275 .61248
= +
28.953 1.4 43.429
= 0.0525

0.052 <= 1.0


OK

Converted to Factor of Safety relevant to 1

1.0
FOS =
f actor
1.0
=
.05247
= 19.059

Bolt BasePlate interaction


Resistance
FOS =
Force
3.2271
=
.61248
= 5.269

Welds
Job Number Sheet
DSU-2017-025
Job Title
DSU - Kenya Operational Hub (KEOH)
Solar Installation For National Blood bank South Sudan
Client
UNOPS Building, UN lane, off UN Avenue Republic Of South Sudan
P.O Box 783, Village Market, 00621. Nairobi Calcs by Checked by Date
ARNOLD T PHILIP M 14/09/2017
Since unit values are used for the length and size of the weld, the capacity
of this layout is given in kN/mm
Design shear strength 4.4

fu
f vw.d =
3 . w. M2
200
=
3 .7 1.25
= 131.966 MPa

Design resistance per unit length 4.3

f vw.d. a . Size
Fw.Rd =
1000
131.97 .707 6
=
1000
= 0.5598 kN/mm

Capacity of 6mm weld is 0.560kN/mm

Resistance
FOS =
Force
.5598
=
.08517
= 6.573