Sie sind auf Seite 1von 1

SENTRY EQUIPMENT CORP.

966 Blue Ribbon Circle North


Oconomowoc, WI 53066
Phone: 262/567-7256 Fax: 262/567-4523
E-Mail: sales@sentry-equip.com
Web: http:/www.sentry-equip.com

SAMPLE COOLERS DESIGN SELECTION CALCULATION


TLR4225U

Date: 11-10-2017 Reference: Gas Combustible


Customer: Dosificacion Proposal No: R0

SYSTEM PERFORMANCE
Tube Shell
Fluid Type Gas Combustible Water
Inlet Temperature [C] 215. 42.
Outlet Temperature [C] 60. 42.07
Fouling Factor [m-K/W] 0.000088 0.000088
Reynolds Number - Outer 5837.27 4642.07
Velocity - Outer [m/s] 0.9804 0.1636
Mass Flow Rate [kg/hr] 0.92 1250.
Calculated Pressure Drop [bar] 0.19 0.25
Heat Load [Watts] 105.78
Heat Transfer Area [m] 0.2276
Over-surface Area [m] 0.2192
Overall Heat Transfer Coefficient [W/m-K] 183.6746
Log-Mean Temperature Difference [C] 68.48

FLUID PROPERTIES

Reference Temperature [C] 137.5 42.04


Viscosity [cp] 0.0145 0.62939
Density [kg/m] 22.36 991.07
Thermal Conductivity [W/m-K] 0.0504 0.63421
Specific Heat [kJ/kg-K] 2.659 4.179
Prandtl Number 0.76546 4.15

TUBE INFORMATION AND VESSEL CONSTRUCTION

Size of Tubes [in] .25 (OD) x 0.049 (thick)


Tube Material 316 Stainless Steel
Shell Material 304 Stainless Steel
Tubeside Ratings: 345. [bar] @ 538. [C]
Shellside Ratings: 31. [bar] @ 343. [C]

Das könnte Ihnen auch gefallen