Sie sind auf Seite 1von 40

cyan magenta yellow black bort kls

CONTACT

Green Roofs
Roof Terraces
Constructions
Green Up The City!
Planning Guide

Dear Partner / Enquirer,

In order to ease your navigation through our catalogue, hyperlinks have


been added. By clicking on the numbered green squares, as well as the
icons listed below you will be directed to the linked pages.

32 Linked page

Virtual House

Table of contents
2008
Previous page

Next page

Our customer service is always ready to assist you as quickly and


conveniently as possible. Therefore, in case you have any questions
related to green roofs in general or to our green roof systems / products in
particular please e-mail us:
info@diademroof.com

We hope you will find this catalogue both beneficial and an enjoyable read.

Your Distributor:

Nominal charge for Guide: 6.00 4.00 8.00 $

www.diademroof.com
cyan magenta yellow black bort bels

VIRTUAL HOUSE VIRTUAL HOUSE

DETAIL INSTRUCTIONS FOR PAGES 8-27

Roof Deck Growing Mediums 15 16 20 21 10 9 11 12 13 26


1a Typically Steel, Timber or 5a SEM Extensive Substrate
Concrete Deck 5b SRM Lawn Substrate
Drought-resistant, herbaceous perennials

DIADEM150
1b Reinforced Concrete Roof Slab 5c SIM Intensive Substrate


1c Screed to Falls 5d SUM Base Substrate 12 cm SEM extensive growing medium
1d Timber Roof Board VLF-150 extensive filter fleece
1e Eaves Profile Retention Support Vegetation 3 cm Diadrain-25 drainage and reservoir board
F G
Bracket 6a Drought-resistant, Herbaceous VLU-300 extensive protection fleece
Perennials Root resistant single ply membrane
Waterproofing and Insulation 6b Perennials, Lawn E 15 cm thermal insulation 8
2a VLT Separation Layer 6c Perennials, Shrubs
17 18 22 23 FLW-400 vapour control layer +28,345 25
2b Vapour Control Layer 6d Trees, Bushes D
Steel deck
2c Waterproofing / Root Resistant 1,95 17,70 15
+15,65
11

DIADEM 750
Coppices/perennials, shrubs vegetation +15,65

10
Membrane Water Management Perennials, lawn
DIADEM 350

A B C +15,31

34
+15,31
9


2d Waterproofing Layer (non root 7a KSE Inspection Box 50 cm SIM intensive growing medium 12
30 cm SIM intensive growing medium 10

24

resistant) 7b KSR Inspection Box VLF-150 extensive filter fleece


2e Root Resistant Membrane 7c KSA Parapet Overflow VLF-200 intensive filter fleece
6 cm Diadrain-60 drainage and reservoir board 5 30 30 12 1,23 5 30
2f Extruded Polystyrene Thermal Inspection Box 4cm Diadrain-40 drainage and reservoir board
VLU-300 extensive protection fleece
Insulation 7d TRF Terrace Grille with fixed height VLR-130 separation fleece for inverted roofs
Root resistant membrane
2g Expanded Polystyrene Thermal 7e TRH Terrace Grille with adjustable 10 cm XPS foam insulation Waterproofing layer
Insulation height VLT-100 separation fleece +12,70 +12,70
14 19 15 cm EPS insulation 27

2,95
5,56
2h Compatible Thermal Insulation 7f TRS Door Access Grille Root resistant single ply membrane +12,36 +12,36
Vapour control layer

5,32
2i Bituminous Self Adheseve Tape 7g RNS Drainage Channel with slotted VLU-300 extensive protection fleece
2k Pond Liner grating 3-6 cm fall forming layer
3-6 cm fall forming layer 15 Reinforced concrete deck
7h RNF Channel with steel grating 5 5 2,00 5 30 3,35 6,49 11,67 3,10

Geotextiles 7i RNH Channel with adjustable height Concrete deck


3a VLU Mechanical Protection 7j BLH Adjustable Terrace Outlet
Layer 7k Water Level Regulator
20

10
3b VLF Filter Layer 7l TGS Heavy Duty Inspection Box +9,75 +9,75 +9,75 +9,75
10

10
+9,41
22

34
+9,41 +9,41

34
34

+9,41 +9,41
3c VLS Water Retention and 7m Extension Element +9,41
21 23

24
24
24

Protection Layer
3d VLR Separation Fleece for Edges 16 2,20 12
1,38 1,70
55 55 11225 2,00 5 30 5,90 10 1,80 10 4,00 10 30 30 10 1,30 30 4,40 10 30 1,70 10 4,40 10 3,10
inverted roofs 8a KLS Gravel Board Trees, bushes vegetation

2,95

DIADEM1200
2,95

2,95

2,61

2,61
2,61

2,61

2,61

2,61
8b RDL Edge Profile "L" shaped 80 cm SIM intensive growing medium


Erosion Control Layers 8c RDA Terrace Kerb "A" shaped VLF-200 intensive filter fleece
3e Geocell 8d BW Concrete Kerb +6,80 +6,80 +6,80 +6,80
3 cm Gardia-30 drainage and protection mat
+6,80

10
+6,80
10

10

3f Jute Netting 8e RDT Edge Profile "T" shaped 15 16 18 17+6,46 +6,46


Root resistant membrane

34
+6,46 +6,46
34

+6,46
34

+6,46
8f Perforated capping sheet Waterproofing layer

24
24
24

Drainage / Reservoir Layers 8g Eaves Profile 5


21
24 3-6 cm fall forming layer
5
10
5
3,74 10 4,20 10 1,70 30 1,70 10 4,40 30 4,40 10 1,70 30 1,70 10 4,40 1,38 10 1,30 30 4,40 10 1,70 30 1,70 10 4,40 10 3,59 20 10
4a Diadrain-25 Drainage / Reinforced concrete deck

2,95
2,95
2,95

Reservoir Board Terrace Construction

2,61

2,61
2,61

2,61

2,61

2,61

4b DiaDrain-40 Drainage / 9a FK Cross Spacers


Reservoir Board 9b SLH adjustable height
4c DiaDrain-60 Drainage / pedestals 13 +3,85 +3,85 +3,85 +3,85 +3,85 +3,85
10

10
10

13
Reservoir Board 9c PGE Plant Containers
34

+3,51 +3,51 +3,51

34
+3,51 +3,51 +3,51
34
24

+3,29

24
24

4d GarDia-30 Drainage /
22

Protection Mat Safety Systems


5

10a DRS Safety Railing System 5 2,69 10 2,10 10 3,65 35 1,57 10 6,20 30 6,20 30 9,70 30 6,20 30 9,89 20 10

10b FLG Fall Arrest System

3,50
3,50

3,06

3,06
3,06

3,06
3,70
3,14

3,36

+0,45 +0,45 +0,45 +0,45 +0,45

10
10

+0,15

35
25

+0,10 +0,10
75 35

8% +0,10
0,10 0,10

25
25
50

75
+0,35 0,35 0,35
26 25 27
12 26
25

3,00
3,00
2,80

5
2,75

2,67
2,75

2,75

32 49,44 30 30
2,30
2,30

+2,65 2,65 2,65 2,65 2,65 2,65


1,15

90

90
90

90

90

90

1,15
1,15

+3,55 3,55 3,55 3,55 3,55 3,55


+3,80 3,80 3,80 3,80 3,80 3,80

25

25
25

25

25

25

MY GARAGE DIADEM-350 DIADEM-750 DIADEM-150 DIADEM-1200 1


CARPORT GREEN ROOF SEMI-INTENSIVE GREEN ROOF ROOF GARDEN SYSTEM EXTENSIVE GREEN ROOF INTENSIVE ROOF GARDEN
www.diademroof.com
INTRODUCTION INTRODUCTION
PRODUCT GROUPS CONTENT

Our vision is a city filled with gardens. In order to help this INTRODUCTION
vision become a reality we have produced this planing guide. Product groups . . . . . . . . . . . . 2

Content . . . . . . . . . . . . . . 3

Advantages of green roofs . . . . . . . . . 4

Typical build up . . . . . . . . . . . . 5

CONTENT
GREEN UP THE CITY!

Diadem systems D150 / D350 . . . . . . . . 6

Diadem systems D750 / D1200 . . . . . . . . 7

TYPICAL SYSTEM SOLUTIONS

GREEN ROOF SYSTEMS Diadem 150 . . . . . . . . . . . . . 8

Diadem 150 rainwater outlet . . . . . . . . . 9

Diadem 150 perimeter wall drainage or overflow . . . . 10

Diadem 150 roof maintenance . . . . . . . . 11

Diadem 150 table top roof edge . . . . . . . . 12

Diadem 150 pitched roof . . . . . . . . . . 13

Diadem 350 . . . . . . . . . . . . . 14

Diadem 350 low parapet . . . . . . . . . . 15

Drainage / Reservoir Boards Diadem 350 outlet. . . . . . . . . . . . 16

Geotextiles Diadem 350 roof details . . . . . . . . . . 17

Growing Mediums Diadem 350 terraces . . . . . . . . . . . 18

Diadem 750 . . . . . . . . . . . . . 19

LAYER COMPONENTS Diadem 750 timber decked terrace . . . . . . . 20

Diadem 750 irrigation unit. . . . . . . . . . 21

Diadem 750 KSA parapet overflow inspection box . . . 22

Diadem 750 terrace access . . . . . . . . . 23

Diadem 1200 . . . . . . . . . . . . . 24

Diadem 1200 trafficable outlet . . . . . . . . 25

Diadem 1200 level access . . . . . . . . . 26

Diadem 1200 deep inspection unit . . . . . . . 27

Inspection Boxes
Irrigation Systems PRODUCTS
Channels and Grilles Organic materials, extensive plants . . . . . . . 28 .
Organic materials, intensive plants . . . . . . . . 29

HYDRO TECHNOLOGY Organic materials, extensive substrate. . . . . . . 30

Organic materials, intensive substrate. . . . . . . 31

Layer components, drainage / reservoir boards . . . . 32

Layer components, geotextiles . . . . . . . . 36

Layer components, root resistant membrane 38

Organic materials, nutrients' supply . . . . . . . 39 .


Hydrotechnology, inspection boxes. . . . . . . . 40

Hydrotechnology, water drainage channels. . . . . . 44

Gravel Boards Hydrotechnology, terrace outlet covers . . . . . . 46

Recycled Plastic Kerbs Hydrotechnology, terrace grilles . . . . . . . 48

Concrete Kerbs Hydrotechnology, terrace grille unit . . . . . . . 49

Hydrotechnology, automatic irrigation system . . . . 50

EDGING Edging, gravel boards . . . . . . . . . . 52

Edging, recycled plastic kerbs . . . . . . . . 54

Edging, concrete kerbs . . . . . . . . . . 56

Terrace building, adjustable-height pedestals . . . . 58

Terrace building, cross spacers . . . . . . . 60

Safety technology, railing systems . . . . . . . 62

Safety technology, roof safety fencing . . . . . . 65

Safety technology, fall arrest system . . . . . . . 66

Terrace Pedestals
Cross Spacers PLANNING GUIDELINES
Plant Containers How to plan and build a green roof . . . . . . . 68

TERRACES REFERENCES
Zsolt Takcs, Gyr Cultural Center . . . . . . .
Tams Lukcsi, Lajta Housing Project, Mosonmagyarvr .
71

72

Our company is engaged in the development, component


production and marketing of DIADEM green roof systems and PRODUCT LIST
accessories. Our products are widely used in all of Europe Summary table . . . . . . . . . . . . 74

especially by customers who emphasize safety and quality.

2 SAFETY TECHNOLOGY 3
www.diademroof.com www.diademroof.com
INTRODUCTION INTRODUCTION
ADVANTAGES OF A GREEN ROOF TYPICAL BUILD UP

Planting options
The type of plants used depends on whether a
low maintenance extensive Green Roof is chosen
or an intensive one with the more formal features
expected from gardens. The former is limited to
ADVANTAGES OF A GREEN ROOF

TYPICAL BUILD UP
ECONOMIC ENVIRONMENTAL succulents, grasses and herbs, while the latter
ADVANTAGES ADVANTAGES can be planted in accordance with the wishes of
the gardener.

SEM / SIM Growing Medium


The depth of soil mix to use depends on whether
A Green Roof gives instant A new and friendly the roof is the extensive or the intensive type. Soil
increase to the value of a environment is created for depth can start from 40 mm upwards. The
property without increasing its people, plants and animals to content and ratio of organic and mineral material
size. Adding a green area lessen the impact of todays in the mixture depends on the types of plants
improves living and working concrete jungles. In no time at used.
surroundings. all plants start to colonise the
roof, and birds, butterfies and
other insects appear. VLF Filter Layer
A filtering sheet to stop leaching of the soil
particles. It is made of rot-proof geotextile.

A reduction is possible on Green Roofs retain and DiaDrain Drainage and Reservoir Boards
drain diameter and sewage recycle water and so free the Draining excess water from the roof, aeration of
charges because much of the sewage system from roots, suppling water and nourishment to plants -
rainwater is recycled into the overloading. It is a balanced all solved by form-pressed drainage boards.
irrigation system of a Green way of water management.
Roof.
VLU-300 Protection Layer
This sheet is for the mechanical protection of the
water insulating layer during construction work. It
retains moisture and allows roots to grow through,
thus enhancing cohesion of the layers above. At
least 300 g/m2 weight should be used of this
The excellent insulating The air contains more material.
properties of a Green Roof moisture and is healthier to
keep buildings warmer in b r e a t h e . Te m p e r a t u r e
winter and cooler in summer, extremes are reduced, and so FLW Root Protection Layer
cutting heating and air are the urban hot spots. This sheet protects the waterproofing and the
conditioning costs. building structure itself from damage from roots in
situations where the waterproofing is not root
resistant. A pre-requisite of this sheet is to have
less resistance to moisture than the water
proofing below.

Noise and particle pollution Many pollutants are VLT Separation Layer
is cut. The building stucture absorbed by a Green Roof, The purpose of this layer is to separate
and its conventional insulation making the air safer to waterproofing from incompatible root protection
gains a longer life span. breathe. Even light pollution is layer, or to separate any other incompatible
reduced to some degree. materials.

Waterproofing Layer

A green roof indicates the The photosynthesis of


building owners concern for plants is the most efficient
the environment. method known to man to
utilise solar energy to best
advantage.

4 5
www.diademroof.com www.diademroof.com
INTRODUCTION INTRODUCTION
DIADEM SYSTEMS D150 / D350 DIADEM SYSTEMS D750 / D1200
DIADEM SYSTEMS

DIADEM SYSTEMS


DIADEM150

DIADEM 350

DIADEM 750

DIADEM1200
EXTENSIVE GREEN SEMI INTENSIVE GREEN INTENSIVE GROUND LEVEL
ROOF ROOF An intensive green roof GREEN ROOF
An ecologically sound Ideal for the creation of system, which may DIADEM-1200 is used in
and economic green an outdoor living space. include an irrigation circumstances, where

roof system that This garden roof system system. Opens up substantial planting is



provides a meadow utilises basic plant practically all the realised by the use of


effect, which requires types, which require possibilities of normal heavy mechanical plant
only low maintenance. more maintenance than ground-level gardening. and equipment during
MEADOW the extensive roof. LANDSCAPED ROOF construction.
LIVING SPACE GARDEN UNDERGROUND
STRUCTURES

8 14 19 24

6 7
www.diademroof.com www.diademroof.com
TYPICAL SYSTEM SOLUTIONS TYPICAL SYSTEM SOLUTIONS
DIADEM 150 DIADEM 150 RAINWATER OUTLET / KSE INSPECTION BOX

Product Description
Diadem-150 is a multi-layer
green roof system, comprising
protection fleece, drainage
layer, filter fleece and mineral-
EXTENSIVE GREEN ROOF DIADEM150

EXTENSIVE GREEN ROOF DIADEM150


rich plant substrate suitable for
drought-resistant plants.


Thickness of system: 70-120 mm
Saturated weight: 90-150 kg/m2
See: 9 10 11 12 13 71

Function
To provide an ecologically
sound protection layer to the
roof with all the advantages
listed below.

Application
Application of the product is
recommended for building
structures with limited load
bearing capacity and in areas
Frequently Asked Questions ? with no or minimal regularity of
use.
Do we need to irrigate vegetation?
No, the vegetation of Diadem-150 consists of drought- Advantages
resistant herbaceous, perennial plants which grow in their Improved thermal insulating
natural habitat under very harsh conditions. ability.
What maintenance does the vegetation require? Rainwater retention
Once established, these plants are extremely sturdy and capability, helping to reduce
consequently require only minimal maintenance, limited to the extent of flash floods.
occasional weeding. Living space for nature
Suitable for most lightweight
How long does it take for the vegetation to become roof structures
established? 1a 2h 2b 2c 4a 7a 3a 3b 8a 5a 6a
This depends on the planting method and the conditions at
the time of planting.
Roof Deck Growing Medium
What type of planting is possible?
1a Typically Steel, Timber or Concrete Deck 5a SEM Extensive Substrate..................... 30
The sedum/wildflower mix is selected to suit the local
conditions.

Waterproofing and Insulation Vegetation


2b Vapour Control Layer 6a Drought-resistant, Herbaceous Perennials 28
Typical build up
2c Waterproofing / Root Resistant
Drought resistant perennial plants. Membrane
2h Compatible Thermal Insulation Water Management
SEM 12 growing medium, possessing low organic material content made of mostly mineral 7a KSE Inspection Box 50-300 mm height.. 40
2

components and with good water permeability characteristics.


12 cm 150 kg/m

Geotextile Layers
3a VLU-300 Mechanical Protection Layer 36
The VLF-150 Filter Layer is a superior geotextile, with excellent strength and pressure resistance
properties. Made of polypropylene, it is capable of high vapour and water pemeability. 3b VLF-150 Filter Layer............................. 36 Edge Profile
8a KLS Gravel Board ................................ 52
Diadrain-25 Light Weight Drainage / Reservoir Board. It has good load bearing capabalities and
Drainage / Reservoir Layer
provides for excellent drainage, reservoir and aeration properties.
4a Diadrain-25 Drainage / ........................ 32

The VLU-300 Mechanical Protection Layer is a specially formulated Polypropylene sheet which Reservoir Board
has a hard upper and soft under side making it ideal for the protection of the waterproofing
membrane.

Root resistant waterproofing membrane.


NOTE: Non root resistant waterproofing membranes require a separate root resistant layer eg. Good practice requires that all times. A 300-500 mm wide achieved by means of a gravel
FLW-400. rainwater outlets are designed gravel border should be board such as KLS. This board
to remain free from installed around all roof also allows rainwater to drain
Compatible thermal insulation layer. obstructions, for example penetrations to the thickness of easily to the outlets.

8 Vapour control layer


gravel or vegetation. These
outlets should be accessible at
the growing medium.
Separation of the materials is 9
www.diademroof.com www.diademroof.com
TYPICAL SYSTEM SOLUTIONS TYPICAL SYSTEM SOLUTIONS
DIADEM 150 PERIMETER WALL DRAINAGE OR OVERFLOW / KSA PERIMETER INSPECTION BOX DIADEM 150 ROOF MAINTENANCE/ FLG SAFETY SYSTEM
EXTENSIVE GREEN ROOF DIADEM150

EXTENSIVE GREEN ROOF DIADEM150


6b 5a 3b 2h 2c 8a 2b 4a 3a 1a 7c 2c 3a 8a 4a 3b 10b 2h 2b 5a 1a 6a

Roof Deck Growing Medium Roof Deck Growing Medium


1a Typically Steel, Timber or Concrete Deck 5a SEM Extensive Substrate..................... 30 1a Typically Steel, Timber or Concrete 5a SEM Extensive Substrate..................... 30
min 80 kg dry weight substrate required to
support FLG Fall Arrest System

Waterproofing and Insulation Vegetation Waterproofing and Insulation Vegetation


2b Vapour Control Layer 6b Perennials, lawn ................................... 28 2b Vapour Control Layer 6a Drought-resistant, herbaceous perennials 28

2c Waterproofing / Root Resistant 2c Waterproofing / Root Resistant


Membrane Membrane
2h Compatible Thermal Insulation Water Management 2h Compatible Thermal Insulation
7c KSA Inspection Box 50-300 mm ......... 43 Edge Profile
Geotextile Layers Geotextile Layers 8a KLS Gravel Board ................................ 52

3a VLU-300 Mechanical Protection Layer 36 3a VLU-300 Mechanical Protection Layer 36

3b VLF-150 Filter Layer............................. 36 Edge Profile 3b VLF-150 Filter Layer............................. 36

8a KLS Gravel Board ................................ 52 Safety System


Drainage / Reservoir Layer Drainage / Reservoir Layer 10b FLG Fall Arrest System ........................ 66

4a Diadrain-25 Drainage / ........................ 32 4a Diadrain-25 Drainage and ................... 32

Reservoir Board Reservoir Board

Good practice dictates that to ensure maintenance the European norms are fully
roof areas should be properly personnel remain safe on the complied with. The line
Good practice requires that also indicate an additional obstruction, therefore access maintained including ensuring roof. The FLG-30 fall arrest system can also be used as
each roof area has a minimum requirement for the installation should be provided for that rainwater outlets are kept system provides this safety an independent lightning
of two drainage points. Local of an overflow. It is important maintenance purposes. clear and free of any element without the need to protection system.

10 conditions determine where


these are located and may
that these drainage points
remain free from any
obstruction. Complementary
to this requirement is the need
penetrate the waterproofing
layer. EN 795 and EN 795/A1 11
www.diademroof.com www.diademroof.com
TYPICAL SYSTEM SOLUTIONS TYPICAL SYSTEM SOLUTIONS
DIADEM 150 TABLE TOP ROOF EDGE / RDT EDGE PROFILE DIADEM 150 PITCHED ROOF / RDTS EAVES PROFILE AND GEOCELL
EXTENSIVE GREEN ROOF DIADEM150

EXTENSIVE GREEN ROOF DIADEM150


<

8e 3b 8a 4a 3a 2c 1a 6a 5a 8g 1e 6a 3a 3f 3e 2c 1d 5a 3b 4a

Roof Deck Growing Medium Roof Deck Drainage / Reservoir Layer


1a Typically Steel, Timber or Concrete Deck 5a SEM Extensive Substrate..................... 30 1d Timber Roof Board 4a Diadrain-25 Drainage /d 32

1e Eaves Profile Retention Reservoir Board


Waterproofing and Insulation Vegetation Support Bracket
2c Waterproofing / Root Resistant 6a Drought-resistant, herbaceous perennials 28 Growing Medium
Membrane Waterproofing and Insulation 5a SEM Extensive Substrate..................... 30

Edge Profiles 2c Waterproofing / Root Resistant


Geotextile Layers 8a KLS Gravel Board ................................ 52 Membrane Vegetation
3a VLU-300 Mechanical Protection Layer 36 8e RDT Edge Profile................................. 54 6a Drought-resistant, herbaceous perennials 28

3b VLF-150 Filter Layer............................. 36 Geotextile Layers


3a VLU-300 Mechanical Protection Layer 36 Eaves Finish
Drainage/Reservoir Layer 3b VLF-150 Filter Layer............................. 36 8g Eaves Profile........................................ 54

4a Diadrain-25 Drainage / ........................ 32

Reservoir Board Erosion Control Layer


3e Geocell
3f Jute Netting

In the case of sloping roof medium and vegetation and forces. The roof edge finish has
structures between 10 and 20 expert advice should be sought. to be designed to withstand the
degree incline, the use of In the case of steeper roof downward forces present. The
Where the roof does not rainwater to the drainage separating the planted area Diadrain-25 in conjunction with designs >20 degrees it is use of the RDTs eaves profile
have a perimeter parapet wall, areas. In addition, this profile by the use of the KLS gravel jute netting provides sufficient essential that a permanent will satisfy this requirment. A
the RDT Edge Profile provides ensures the edge of the roof board. The boards also erosion protection. However, Geocell soil erosion prevention sloping sedum roof construction
one possible solution to the garden build up is obscured prevent the spread of plants careful consideration should still layer is installed. This layer should not require any special
problem of how to retain the from view. The required gravel into the gravel border, thereby be given to the roof edge finish. should act independently of the irrigation system however a

12 garden elements, whilst still


allowing the free flow of
border around the perimeter
is achieved by means of
keeping maintenance to a
minimum.
All sloping roofs require the
careful choice of growing
waterproofing membrane to
avoid the transfer of shearing
grass roof will.
13
www.diademroof.com www.diademroof.com
TYPICAL SYSTEM SOLUTIONS TYPICAL SYSTEM SOLUTIONS
DIADEM 350 DIADEM 350 LOW PARAPET / RNS DRAINAGE CHANNEL

Product Description
Diadem-350 is a semi intensive
type of green roof, generally
covered with grasses,
perennials and shrubs, offering
SEMI INTENSIVE GREEN ROOF DIADEM 350

SEMI INTENSIVE GREEN ROOF DIADEM 350


different finishes and uses.

Thickness of system: approx. 300 mm


Saturated weight: approx. 350 kg/m2
See: 15 16 17 18 71

Function
In addition to the usual

15 cm
ecologically benefits this type of
construction has the added value
of providing additional valuable
space for recreational use.

Application
This type of installation is
recommended where there is
the desire to create a pleasant
enviroment that can be used
Frequently Asked Questions ? by those working or living at
the location.
Why semi-intensive?
It may be that the roof structure cannot support the weight of Advantages
a more elaborate fully landscaped roof garden design. Suitable for every day use
Property value increases
What about maintenance? Better use made of
This should be considered at the early planning stages and available space
should include such matters as providing suitable access, Wide range of designs are
irrigation and a maintenance program. possible
Relatively low investment
What about lawn maintenance? cost
2g 2f 2c 1c 4b 3a 7h 3b 1b 5b 6b
A lawn should be cut often and regularly in order to ensure Technically sound
that the cuttings remain short and therefore do not need to be Improved thermal efficiency
collected. Indeed, these cuttings provide beneficial nutrients Enhanced enviromental
for the lawn. benefits Roof deck Drainage / Reservoir Layer
Good rainwater retention 1b Reinforced concrete roof slab 4b Diadrain-40 Drainage / ........................ 32
Installation is more 1c Screed to falls Reservoir Board
economical than that of a
fully landscaped roof
garden. Waterproofing and Insulation Growing Medium
Ideal for an inverted roof 2c Waterproofing / Root Resistant 5b SRM Intensive Lawn Substrate ............ 30
Typical build up construction as it provides
Membrane
the advantage of additional
Soil-covering plants with grass types, perennials and shrubs. roof membrane protection. 2f Extruded Polystyrene Thermal Insulation
2g Expanded Polystyrene Thermal Vegetation
SRM-30 is a nutrient rich soil mix consisting of lava, pumice, Insulation 6b Perennials, lawn
recycled crushed clay based products and enriched with compost. SRM is ideal for lawns.

VLF-200 is a superior geotextile, with excellent strength and pressure resistence properties. Made Geotextile Layers Drainage Products
of polypropylene, it is capable of high vapour and water pemeability. 3a VLU-300 Mechanical Protection Layer 36 7h RNF Channel with steel grating ........... 44

3b VLF-150 Filter Layer............................. 36


Diadrain-40 is a light drainage/reservoir board. It has good load bearing capabilities and provides
for excellent drainage, reservoir and aeration.

Extruded polystyrene thermal insulation boards suitable for inverted roof construction.

Optional: VLU-300 protection and separation fleece. Note: This layer must be installed where
compatibility problems exist between the different layers.

Root resistant waterproofing membrane. NOTE: Non root resistant waterproofing membranes
require a separate root resistant layer eg. FLW-400. An inverted roof installation A limiting factor may be the the required upstand height
can be an efficient method of height of the existing can be measured from the
Screed to falls. retro fitting insulation in order upstands. To help alleviate this base.
to bring the building up to problem the RNS Drainage
14 Reinforced concrete roof deck. current thermal requirements. Channel can be installed and 15
www.diademroof.com www.diademroof.com
TYPICAL SYSTEM SOLUTIONS TYPICAL SYSTEM SOLUTIONS
DIADEM 350 OUTLET/KSE INSPECTION BOX DIADEM 350 ROOF DETAILING / DRS PLANTER AND RNF CHANNEL
SEMI INTENSIVE GREEN ROOF DIADEM 350

SEMI INTENSIVE GREEN ROOF DIADEM 350


1b 2c 2f 3b 3a 7a 4b 8a 5b 6b 1c 5a 6b 3b 10a 9c 1c 9a 4b 2f 3c 2c 7h

Roof deck Drainage / Reservoir Layer Roof deck Growing Medium


1b Reinforced concrete roof slab 4b Diadrain-40 Drainage .......................... 32 1c Screed to falls 5a SRM Intensive Lawn Substrate 30

1c Screed to falls and Reservoir Board


Waterproofing and Insulation Vegetation
Waterproofing and Insulation Growing Medium 2c Waterproofing / Root Resistant 6b Perennials, Lawn, Shrubs ....................
2c Waterproofing / Root Resistant 5b SRM Intensive Lawn Substrate 30 Membrane
Membrane 2f Extruded Polystyrene Thermal Drainage Products
2f Extruded Polystyrene Thermal Insulation Vegetation Insulation 7h RNF channel with steel grating............ 44

6b Perennials, Lawn .................................


Geotextile Layers Geotextile Layers Materials of Terrace Construction
3a VLU-300 Mechanical Protection Layer 36 Water Management 3b VLF-150 Filter Layer............................. 36 9a FK Cross Spacers ............................... 60

3b VLF-150 Filter Layer............................. 36 7a KSE Inspection Box 50-300 mm height.. 40 3c VLU-300 Mechanical Protection Layer 36 9c PGE Plant Containers .......................... 62

Edge Profile Drainage / Reservoir Layer Roof Safety


8a KLS Gravel Board ................................ 52 4b Diadrain-40 Drainage and ................... 32 10a DRS Safety Railing System.................. 62

Reservoir Board

Rainwater running down the cause problems. The RNF practical, yet aesthetically
wall can often be as much as Drainage Channel provides a pleasing means of providing
It is important that the and to the same diameter. with the KLS Gravel Board and that accumulating from the perfect solution. Paving slabs protection and creating
rainwater is able to flow freely A KSE Inspection Box is then Diadrain Drainage Layer horizontal roof surface. It is should be laid with open joints demarcated areas.
to the drainage points. This is placed above the opening ensures that the water therefore crucial that at the and kept permanently Maintenance personnel can
achieved by cutting a hole in and supported on the reaching the outlet is clear of junction of these planes water separated by the use of FK also use the DRS as an

16 the drainage layer and


insulation around the outlet
d r a i n a g e l a y e r. T h e K S E
Inspection Box in conjunction
any material that may cause
an obstruction.
is prevented from building up
to levels which are likely to
Cross Spacers. The DRS
Safety Railing System is a
anchor point for safety
equipment. 17
www.diademroof.com www.diademroof.com
TYPICAL SYSTEM SOLUTIONS TYPICAL SYSTEM SOLUTIONS
DIADEM 350 TERRACES/ BLH OUTLET AND BW KERB DIADEM 750

Product description
Diadem-750 is an intensive
roof garden, comparable with
a ground level natural garden
in that its design and planting
SEMI INTENSIVE GREEN ROOF DIADEM 350

LANDSCAPED ROOF GARDEN DIADEM 750


a r e s i m i l a r. B y u s e o f a
sophisticated yet simple water
management system it is
possible to plant and grow


more demanding vegetation,
even trees.

Thickness of system: approx. 500 mm


Saturated weight: approx. 750 kg/m2
See: 20 21 22 23 72

Function
To c r e a t e a l a n d s c a p e d
garden on the roof.

Application
This system is ideal, where a
suitable strong load bearing
structure is available. Frequently Asked Questions ?
Advantages Can plant roots cause any damage?
Suitable for every day use Modern, root resistant waterproofing membranes prevent root
Property value increases penetration. With some membranes it will be necessary to install
Best use made of available a separate root resistant layer such as FLW-400.
space
Wide range of designs are Can I grow large trees on my roof garden?
possible Yes, by applying our root-ball fixing sets.
Technically sound
Improved thermal efficiency Is it possible to construct a pond on the roof?
Excellent enviromental Yes, see page 18 for instructions.
2k 4b 8d 1b 9a 3d 2f 7j 2c 3a 1c 3b
benefits
Better rainwater retention Who should design my intensive roof garden?
The creative aspect can be shared but we recommend that you
Roof deck Drainage Layer seek professional assistance from an experienced landscape
architect or qualified horticulturist.
1b R einforced concrete roof slab 4b DiaDrain-40 Drainage / Reservoir........ 32

1c Screed to falls Board filled with chippings

Waterproofing and Insulation Water Management


2c Waterproofing / Root Resistant 7j BLH adjustable 60-300 mm height ..... 49
Typical build up
Membrane terrace outlet
2f Extruded Polystyrene Thermal Insulation Ground cover plants, shrubs, some trees, grasses, etc...
2k Pond Liner sandwiched between two Edge Kerb
VLU-300 fleece protection layers 8d BW Concrete Edge Kerb ..................... 56 SIM-56 is a nutrient rich soil mix consisting of lava, pumice, recycled crushed clay based
products and enriched with compost. SIM is ideal for intensive vegetation

Geotextile Layers VLF-200 is a superior geotextile, with excellent strength and pressure resistence properties. Made
3a VLU-300 Mechanical Protection Layer 36 Materials of Terrace Construction of polypropylene, it is capable of high vapour and water pemeability.
3b VLF-150 Filter Layer............................. 36 9a FK Cross Spacers ............................... 60
DiaDrain-60 is a heavy duty, dimensionally stable drainage/reservoir board. It has both good water
3d VLR-130 Filter Separating Layer .......... 36
retention and drainage properties and can be used in conjunction with the Diadem irrigation
system.

VLU-500 protection and separation fleece.

It is possible to create a Protective Fleece, pond liner Outlet. An important feature of Root resistant waterproofing membrane. NOTE: Non root resistant waterproofing membranes
simple pond construction on and a further upper layer of this product is that it can be require a separate root resistant layer eg. FLW-400.
the roof using the BW VLU-300 Protective Fleece. It adjusted between 60 and 300
concrete edge pieces to form is important that the pond liner mm, giving greater freedom in Insulation.
the perimeter. This structure is not used as the primary the design of the terrace build
would then be lined with a waterproofing layer. Dual up. Vapour control layer.
sandwich construction formed drainage can be achieved by
18 of an underlayer of VLU-300 means of the BLH Terrace Reinforced concrete roof deck. 19
www.diademroof.com www.diademroof.com
TYPICAL SYSTEM SOLUTIONS TYPICAL SYSTEM SOLUTIONS
DIADEM 750 TIMBER DECKED TERRACE / SLH, TRF, BW DIADEM 750 IRRIGATION UNIT / BKS
LANDSCAPED ROOF GARDEN DIADEM 750

LANDSCAPED ROOF GARDEN DIADEM 750


1b 2b 2g 7e 2c 3a 9b 4c 8d 2i 3b 5c 6c 1b 2b 2g 7k 7m 2c 7b 3c 5c 8a 3b 4c 8c 6c

Roof deck Growing Medium Roof deck Growing Medium


1b Reinforced concrete roof slab (Zero falls) 5c SIM Intensive Substrate ...................... 31 1b Reinforced concrete roof slab (Zero falls) 5b
5b SIM Intensive Substrate ....................... 31

Waterproofing and Insulation Vegetation Waterproofing and Insulation Vegetation


2b Vapour Control Layer 6c Perennials, Lawn, Shrubs, small Trees, etc... 29 2b Vapour Control Layer 6c
6c Perennials, Lawn, Shrubs, small Trees, etc... 29

2c Waterproofing / Root Resistant 2c Waterproofing / Root Resistant Membrane


Membrane Water Management 2g Insulation Water Management
2g Insulation 7e TRH Terrace Grille height adjustable 46 7b KSR Inspection Box 250-800 mm height .
7b 42

2i Bituminous self adheseve tape Geotextile Layers 7k


7k Water Level Regulator ......................... 50

Edge 3b VLF-200 Filter Layer............................. 36 7k


7m Extension Element............................... 50

Geotextile Layers 8d BW Concrete Edge Kerb ..................... 56 3c VLS-500 Water Retention and ............. 36

3a VLU-500 Mechanical Protection Layer 36 Protection Layer Edge


3b VLF-200 Filter Layer............................. 36 Terrace Building 8a
8a KLS Gravel Board ................................ 52

9b SLH height adjustable decking / ........ 58 Drainage Layer 8c RDA Terrace Kerb 250-400 mm height ....
8c 55

Drainage Layer paving support 4c DiaDrain-60 Drainage / Reservoir........


4c 32

4c DiaDrain-60 Drainage / Reservoir........ 32 Board filled with chippings


Board filled with chippings
The BKS Irrigation System connected to the water mains lightweight alternative to the
works on the principle of a via a double check valve. This traditional heavy garden wall
uniform level of water being rainwater harvesting tank is construction. In addition to
In some instances it may be case there is no need for the system whilst drainage maintained on the roof constructed specifically for providing separation of the
neccessary to place decking water retention. The DiaDrain remains unimpeded. Finally surface. This is achieved by each project. The water level garden and terrace elements,
over the rainwater outlets. Drainage Board is installed the joints of the BW Concrete constructing the roof to zero on the roof is maintained at a it also provides a decorative
Access to these outlets is still with the venting holes face Kerb are sealed with a self falls. As the water level drops predetermined level by means finish which can be used for
essential and is easily down. The DiaDrain is then adhesive bitumen strip. this is replenished from a of an extension piece the location of cables, pipes,

20 achieved by means of the


TRH Terrace Grating. In this
filled with chippings. This
gives added fire protection to
separate rainwater harvesting
tank, which in turn is
attached to each outlet. The
RDA is a cleverly designed
etc. and lighting.
21
www.diademroof.com www.diademroof.com
TYPICAL SYSTEM SOLUTIONS TYPICAL SYSTEM SOLUTIONS
DIADEM 750 KSA PARAPET OVERFLOW INSPECTION BOX DIADEM 750 TERRACE ACCESS/ RNF RAINWATER CHANNEL AND TRH OUTLET COVER HATCH4
LANDSCAPED ROOF GARDEN DIADEM 750

LANDSCAPED ROOF GARDEN DIADEM 750


2g 7c 3b 4c 3c 2g 2c 8d 5b 2b 1b 3b 4c 1c 9a 7e 2g 3a 7h 2b 1b 2c

Roof deck Growing Medium Roof deck Drainage Layer


1b
1b Reinforced concrete roof slab (Zero falls) 5b SIM Intensive Substrate ....................... 31 1b Reinforced concrete roof slab 4c DiaDrain-60 Drainage / Reservoir laid....... 32

1c Screed to falls up side down and filled with chippings


Waterproofing and Insulation Water Management
2b Vapour Control Layer........................... 38 7c KSA Parapet Overflow ......................... 43 Waterproofing and Insulation Water Management
2c Waterproofing/Root Resistant Membrane Inspection Box 50-300 mm 2b Vapour Control Layer........................... 38 7e TRH Terrace Grille height adjustable.... 46

2g Insulation 2c Waterproofing/Root Resistant Membrane 7h RNF Channel with steel grating ........... 44

Edge 2g Insulation
Geotextile Layers 8d BW Concrete Edge Kerb ..................... 56

3b VLF-200 filter layer ............................... 36 Geotextile Layers Terrace Building


3c VLS-500 Water Retention and ............. 36 3a VLU-500 Mechanical Protection Layer.... 36 9a FK Cross Spacers ............................... 60

Protection Layer 3b VLF-200 Filter Layer............................. 36

Drainage Layer
4c DiaDrain-60 Drainage / Reservoir........ 32

Board filled with chippings

Rainwater from the vertical to levels which are likely to separated by the use of FK
It is good practice to protect A hinged lid ensures that the prevent the spread of plants face of a wall or door etc.can cause problems to the Cross Spacers. The TRH
the overflow from any unit remains intact even in into the river stone border, often be as much as that building structure or even provides a cover for the
obstructions. The KSA high winds. The required river thereby keeping maintenance accumulating from the water ingress. The RNF rainwater outlet and is height
Overflow Inspection Box stone border around the to a minimum. horizontal roof surface. It is Drainage Channel provides a adjustable in order to
achieves this whilst also perimeter is separated from therefore crucial that at the perfect solution. Paving slabs accomodate tolerances in the

22 providing access for


maintenance and inspection.
the planted area by the BW
Concrete Kerb. The kerbs also
junction of these planes water
is prevented from building up
should be laid with open joints
and kept permanently
laid paving.
23
www.diademroof.com www.diademroof.com
TYPICAL SYSTEM SOLUTIONS TYPICAL SYSTEM SOLUTIONS
DIADEM 1200 DIADEM 1200 TRAFFICABLE OUTLET / TGS HEAVY DUTY INSPECTION BOX

Product Description
DIADEM-1200 is an elaborate,
park-like intensive roof garden
at ground level.
HEAVY PLANTING BY MECHANICAL MEANS DIADEM 1200

HEAVY PLANTING BY MECHANICAL MEANS DIADEM 1200


Thickness of system: approx. 800 mm


Saturated weight: approx. 1200 kg/m2
See: 25 26 27 34 35

Function
To p r o v i d e , p a r k - l i k e
recreational areas at ground
level.

Application
Suitable for ground level
structures such as
underground car parks.
Frequently Asked Questions ? Advantages
Quick installation.
Is the product suitable for public areas? Use of heavy machinery
Diadem-1200 is ideal for creating park-like recreational areas possible.
above underground garages, walkways and tunnels, etc. Drainage layer made from
Is it suitable for emergency vehicle access? recycled material.
No, in this case we have another solution using MDE-60
Drainage Board. Please seek our advice.
What is the likely lifespan of the vegetation?
The lifespan is as for plants found in their natural habitat,
providing they receive proper maintenance.
1b 1c 3c 7l 2c 4c 3b 6d 2i 8d 5c

Roof Deck Growing Medium


1b Reinforced Concrete Roof Slab 5b SIM Intensive Substrate ....................... 31

1c Screed to Falls

Waterproofing and Insulation Vegetation


2c Waterproofing/Root Resistant Membrane 6d Perennials, Lawn, Shrubs, small Trees, etc...29
2i Bituminous Self Adheseve Tape

Geotextile Layers Water Management


3b VLF-200 Filter Layer 36 7l TGS Heavy Duty Inspection Box ......... 46

3c VLS-500 Water Retention and 36 150-750 mm height


Typical build up
Protection Layer

Ground covering plans, perennials, shrubs and trees Drainage Layer Edge
4c DiaDrain-60 Drainage / Reservoir 32 8d BW Concrete Edge Kerb ..................... 56
SUM and SIM are the respective base and top layer soil substrate. See page 31
filled with chippings
VLF-200 is a superior geotextile, with excellent strength and pressure resistence properties. Made
of polypropylene, it is capable of high vapour and water pemeability.

GarDia-30 is an integrated protection, drainage and filter layer manufactured from recycled
polyethylene with specially formed drainage channels. See page 34-35.

Waterproofing. Use of the DiaDrain-60 or the various building elements. for additional protection. The
MDE-60 drainage board in this The TGS Heavy Duty TGS cover is removable to
Screed to falls. construction allows for Inspection Box permits both allow inspection and on

24 Reinforced concrete roof deck.


continuous uninterrupted
drainage of rainwater beneath
pedestrian and vehicular traffic
to pass over without the need
completion can be locked for
security. 25
www.diademroof.com www.diademroof.com
TYPICAL SYSTEM SOLUTIONS TYPICAL SYSTEM SOLUTIONS
DIADEM 1200 LEVEL ACCESS/ TRS DOOR ACCESS GRILLE DIADEM 1200 DEEP INSPECTION UNIT / KSR EXTENDED INSPECTION BOX AND
HEAVY PLANTING BY MECHANICAL MEANS DIADEM 1200 POP-UP SEPARATION MEMBRANE

HEAVY PLANTING BY MECHANICAL MEANS DIADEM 1200


15 cm / 6"

1b 2g 7f 3a 2c 4c 9a 3b 1b 1c 4d 2c 7b 3b 8f 6d 5b 5d

Roof Deck Drainage Layer Roof Deck Growing Medium


1b Reinforced Concrete Roof Slab 4c DiaDrain-60 Drainage Board laid up ... 32 1b Reinforced Concrete Roof Slab 5b SIM Intensive Substrate ....................... 31

side down and filled with chippings 1c Screed to Falls 5d SUM Subsrate for deep soil courses... 31

Waterproofing and Insulation


2c Waterproofing/Root Resistant Membrane Water Management Waterproofing and Insulation Vegetation
2g Insulation 7f TRS Door Access Grille ....................... 48 2c Waterproofing/Root Resistant Membrane 6d Perennials, Lawn, Shrubs, small Trees, etc...29

Geotextile Layers Geotextile Layers Water Management


3a VLU-500 Mechanical Protection Layer 36 Terrace Building 3b VLF-200 Filter Layer............................. 36 7b KSR Inspection Box 250-800 mm height.. 42

3b VLF-200 Filter Layer............................. 36 9a FK Cross spacers................................ 60

Drainage Layer Edge


4d GarDia-30 Drainage and ..................... 34 8f Perforated Capping Sheet...................
Protection Mat

It is increasingly common TRS Door Access Grille, proper falls are designed to
for clients to demand level which, by the nature of it's ensure that rainwater is
access from their building to extended size and open directed away from the
the adjoining terrace. This structure removes the danger building. In some locations a
creates detailing difficulties of any build up in this crucial canopy should be installed Locating Perforated build up the required gravel which prevent leaf blockage
with regard to ensuring there is area by feeding the rainwater above the door. Capping Sheet around the border. For additional security and also add structural

26 no water ingress. One


possible solution is to use the
directly into the drainage
system. It is essential that
extended KSR Inspection Box
solves the problem of how to
the KSR unit has integral
perforated protection plates
strength to the unit.
27
www.diademroof.com www.diademroof.com
PRODUCTS PRODUCTS
ORGANIC MATERIALS EXTENSIVE PLANTS ORGANIC MATERIALS INTENSIVE PLANTS

Extensive plants started off with about 15 Intensive plants not only the habits of each
The plants of Diadem 150 are specimens per m2. One tray of Intensive plants are a selection species but also their
mainly succulents, grasses plants contains 40 specimens of flora and foliage, which are resistence to damage by
and herbaceous perennials. in cups of 0.15 Litre. most suitable to live on a roof wind, frost and sun. When
These plants can live together Dimensions of polystyrene environment without choosing the growth medium,

INTENSIVE PLANTS
EXTENSIVE PLANTS

in a stable partnership when tray: 550 350 75 mm. endangering the structure of plants with similar soil needs
the building. Selecting woody should be placed together.
Standards stems create the feeling of a Below is a small sample of the
FLL 10.2./2002 ground level garden. Making plants available for intensive
DIN 18916 Plant Technology in Landscaping our selection we considered roof gardens.

Sedum acre Pinus Mugo Mops


Bitter stonecrop Mugo pine
5-10 cm, V-VI, { yellow 40 - 80 cm, dark green foliage

Dianthus deltoides Cerastium tomentosum Pinus leucodermis Com- Forsythia suspensa


15 cm, VI-VIII, 10 cm, V-VI, pact Gem 0.5-1.5 m IV-V,
{ bright pink { white 50 cm, dark green foliage { Cadmium yellow

Thymus serpyllum Dianthus pontederae Pinus sylvestris Argentea Prunus tenella


15 cm, V-VIII, 15 cm, VI-VIII, Compacta 0.6-1.0 m, IV-V,
{ purple { pink 2.0 m, silver { rose

Sedum hybridum Achillea tomentosa Cytisus purpureus Berberis thunbergii


10 cm, VI-VIII, 20 cm, VI-VII, 30-60 cm, VI-VII, { purple 1.5-2.5 m, IV-V,
{ Gold { yellow stems, yellow bloom { yellow

Geranium x magnificum Sedum floriferum Juniperus sabina Tama- Erica carnea


50 cm, VI-VII, 15 cm, VI-VIII, riscifolia 0.2 m ,III-IV,
{ violet-blue { yellow 3-40 cm, blue-green foliage { rose

Sedum sexangulare Campanula carpatica Ononis repens Ligustrum vulgare


15 cm, VI-VIII, 20 cm, VI-VIII, 20-40 cm, VI-VII, 0.5-0.7 m,
{ yellow { blue { lilac dark green foliage

Sempervivum ssp. Gypsophila repens Microbiota decussata Potentilla fruticosa


10 cm, VI-VII, 20 cm, VI-VII, 20-40 cm, 0.3-1.5 m, V-IX,
{ white / rose { white green foliage { yellow

Sedum album Festuca glauca Cotoneaster tomentosus Euonymus fortunei


15 cm, VI-VII, 20 cm, V-VI, blue foliage, 1.5 m, V-VI, 0.2-5.0 m, VI-VII,
{ white blooms of green with purple tinge { rose { lightgreen

Sedum spurium Koeleria glauca Acer palmatum Spirea albiflora


15 cm, VII-VIII, 40 cm, VI-VII, 3.0-4.0 m, V-VI, { from green to 0.3-1.,5 m, V-VI,
{ white blueish green yellow, bronze, purple and red { white

Origanum vulgare Phlox douglasii Caragana aurantiaca Cotinus coggygria


15 cm, VI-VIII, 10 cm, IV-V, 1.0 m, V, 2.0-4.0 m, III-IV,
{ pink { pink { yellow { pink

Iberis sempervirens Sedum reflexum Buxus sempervirens Viburnum bodantense


30 cm, IV-VII, 20 cm, VII-VIII, 1.0-3.0 m, IV-V, 2.5-3.0 m, XI-III,
{ white { yellow { yellow { rose

Allium sphaerocephalon Potentilla verna Ilex aquifolium Cornus mas


30-70 cm, VI-VIII, 20 cm, III-VIII, 0.3-0.8 m, 3.0-5.0 m, III-IV,
{ red { yellow darkgreen foliage { yellow

Alyssum saxatile Saponaria ocymoides Buddleia davidii Anemone hupehensis


30 cm, IV-V, 15 cm, V-VII, 2.0-4.0 m, VII-VIII, 0.7-1.0 m, VII-X,
28 { yellow { rose { blue lilac { white 29
www.diademroof.com www.diademroof.com
PRODUCTS PRODUCTS
ORGANIC MATERIALS EXTENSIVE SUBSTRATE ORGANIC MATERIALS INTENSIVE SUBSTRATE

INTENSIVE SUBSTRATE
EXTENSIVE SUBSTRATE

SEM

SRM

SIM

SUM
Substrate for Substrate for Substrate for DIADEM-1200
Diadem-150 Diadem-350 Diadem-750 "subsoil"
A loose, mainly mineral A loose mix made up A loose mix for intensive A sterilised mix of deep
substrate with good especially for turfs. It has green roofs for a wide substrates used as a
drainage properties and good aerating and variety of plants, with base layer to provide for
low organic content for drainage qualities, good water draining and excellent drainage and
use on extensive green resists compression and aerating properties. aeration to roofs.
roofs. contains the starting
amount of lawn fertilzer.

Technical data SEM SRM Technical data SIM SUM


Volume weight in case of WSmax <1000 kg/m3 * in case of WSmax <1200 kg/m3 Volume weight in case of WSmax <1200 kg/m3 in case of WSmax <1500 kg/m3 *
Sediment (<0,0063) < M 15% < 20 m% Sediment (<0,0063) < 20 m% < 20 m%
Air content > 70 Vol.% > 70 Vol.% Air content > 60 Vol.% > 55 Vol.%
Max. water capacity 15 - 25 Vol. % 45 - 65 Vol. % Max. water capacity 40 Vol. % 35 - 55 Vol. %
Water soluble minerals < 3,5 g/l < 2,5 g/l Water soluble minerals < 2,0 g/l < 3,5 g/l
Organic material content 1,0 - 3,0 m% 6,0 - 12,0 m% Organic material content 3,0 - 8,0 m% 3 m%
pH (CaCl2) 6,5 - 8,0 5,5 - 7,0 pH (CaCl2) 5,5 - 7,0 5,5 - 7,0
Absorption capacity - > 120 mmol/l Absorption capacity > 140 mmol/l > 60 mmol/l
Nutrient NPK 80-200-700 mg/l - Nutrient NPK - -
*Should be established also for dry condition. *Should be established also for dry condition.

30 31
www.diademroof.com www.diademroof.com
PRODUCTS PRODUCTS
LAYER COMPONENTS DRAINAGE / RESERVOIR BOARDS LAYER COMPONENTS DRAINAGE / RESERVOIR BOARDS

Product description
The DiaDrain a water drainage Operational
and reservoir board made from diagram
heavy duty polystyrene. The C The primary function of
surface is shaped on both flat roof drainage/
DIADRAIN 25/40/60

DIADRAIN 25/40/60
sides and perforated on the reservoir boards is to
top. drain the excess of
sudden torrents into the
DiaDrain-25 drainage system (A). A
25 mm high drainage/reservoir A secondary function is to
boards for extensive roof allow air to access the
gardens. roots (B). Finally, while
having good water
Product name Product number retaining and load
DiaDrain-25 310025 bearing qualities, to
DiaDrain-40 310115 supply water to plants
DiaDrain-60 310107 by diffusion (C) in the
MDE 60 310117 dry periods.
TerraDrain-06 310140
Standards
EN 964-1 Sizing
DIN EN ISO 12958 Water draining capacity
NF T 56-101 Load bearing strength
FLL guidelines 7.2./2002
DiaDrain-40 B
Related pages
40 mm high drainage/reservoir
8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 25 26 board for extensive and semi
intensive green roof gardens.

Application
The DiaDrain product family is Advantages Installation instructions Tools needed for
formulated for continuous Simple and quick When not using them on an installation
drainage of green roofs. installation inverted roof, the boards A sharp knife will cut the boards
Depending on the product Low structural weight should be laid on a protection but care must be taken not to
choosen it can take the weight Excellent load bearing fleece type VLU-300. It is damage any waterproofing
of pedestrian or even heavy capacity advised to have an overlap of 1 below.
vehicle traffic (such as fire Increased water-draining or 2 rows. Above the position
engines or furniture vans). The and venting capacity of drain pipes the board Packing, Transport and
boards can be filled with Good stability in retaining its should be cut away to enable Storage instructions
MDE-60 various materials to enhance form inspection. It is necessary to The product is to be protected
Fixing elements are provided the load-bearing capacity of Economical storage and weigh down the boards if roof from protracted sunlight.
to use when securing the product. transport installation is made in stages.
additional structures to the roof Continuous aeration
(such as trees, solar panels or DiaDrain-60 Extends the lifespan of
air conditioning equipment) 60 mm high heavy duty large green roofs
without drilling through the capacity reservoir and draining
water-proofing. The weight of boards suitable even for
these fixtures is negligible but flooded green roofs. The
they provide suitable secure boards provide a sound
anchorage together with the framework to support roads
weight of the green roof for and kerbs, while giving Frequently asked questions ?
distribution of both pulling or continuous drainage.
pushing weight. Why do you recommend a draining layer shaped on
both sides?
A double moulded layer ensures that there are two ways for air to
Technical data Dim DiaDrain-25 DiaDrain-40 DiaDrain-60 MDE-60 Terradrain-06 get in and water to get out enhancing the efficiency of drainage
Product Number 310125 310115 310107 310117 310140 and ventilation.
Height [mm] 25 40 60 60 6
Width [mm] 900 900 900 900 2200
Length [mm] 1960 1960 1960 1960 32000 Why polystyrene?
Volume [l/m2] 10 18,0 28,8 28,8 2,60 Polystyrene retains its shape well in high summer temperatures
2
Weight [kg/m ]
2
1,30 1,73 2,70 3,67 0,125 and tests support the view that even after 50 years of use it will
Compressive strength [kN/m ] 484 330 270 560 900 not alter its form substantially.
Water draining capacity DIN 4095 [l/min/mm] 243000 392000 486000 486000 -
Water draining capacity DIN 4095 [l/ms] 4,0 6,5 8,1 8,1 -
Water draining capacity i=1 [l/m/s] 0,8 1,31 1,62 1,62 0,79 Which side up should the boards be installed?
Material Recycled polystyrene Recycled polystyrene Recycled polystyrene ABS HDPE / PP At planted areas the diffusion holes should point upwards.
Colour Black Black Black magenta Black / Grey Under paved or boarded areas the holes should be pointing
Number in packaging [m2/palett] 700 500 350 250 352
downwards.
Laying at 2-3 incline Overlapping Overlapping Overlapping Overlapping Overlapping
In accordance with DIN 4095 Guidelines. (0.3 l/m2 in front of walls; 0.03 l/m2 x s on roofs; 0.003 l/m2 x s below paving)
All technical data are averages of results which the various examining bodies have measured.
We reserve the right to change technical data.

32 33
www.diademroof.com www.diademroof.com
PRODUCTS PRODUCTS
LAYER COMPONENTS DRAINAGE / RESERVOIR BOARDS LAYER COMPONENTS DRAINAGE / RESERVOIR BOARDS

Product description
GarDia, a drainage and water Operational
reservoir board made from diagram
recycled pieces of polystyrene The boards have water
without the use of any binding grooves lengthways,
GARDIA 30

GARDIA 30
agent. It has excellent heat and crossways and along
sound insulating qualities and their edges, which also
will withstand mechanical wear help root ventilation.
and tear during installation

800
Product name Product number
GarDia-30 310024
Standards
EN 964-1 shape sizing
DIN EN ISO 12958 water draining capacity
NF T 56-101 load bearing capacity
FLL guide lines 7.12./2002; 5.3./2002
Related pages
24 27 1500

Application
Recommended for drainage of
intensive green roofs and of
garage roofs used by vehicle Advantages Installation instructions Tools needed for
traffic. Heat insulating With the grooved side facing installation
Sound insulating down, lay out the boards An ordinary fretsaw with a
Rot-proof edge to edge to cover the blade suitable for wood.
Easy to cut and shape whole area to be treated. It is
pieces not necessary to line up the Packing, Transport and
grooves, as the edges also Storage instructions
Material provide channelling. The The product should be
Bonded polyethylene pieces surface can be used at once protected from protracted
compressed at high and machinery can be driven sunlight. One bale contains 12
temperatures without over it, however it may be boards. For safety, no more
adhesives. necessary to weigh it down than 8 bales should be
against wind uplift. stacked.

Technical data Dim GarDia-30


Product number - 310024
Finish - Attached layers
Width [mm] 800
Lenght [mm] 1500
Thickness [mm] 30
2
Surface weight [kg/m ] 1,8

?
3
Volume weight [kg/m ] 81,2
2 Frequently Asked Questions
Loadability to 10 % compression [kN/m ] 62
Water draining capacity i=1,0 (EN 12958) [l/ms] 0,47
Water draining capacity i=3% (EN 12958) [l/ms] 0,49 Which side is up?
Maximum distance for rainwater run off [mm] 13400
Boards are always to be built in with the channels down.
Water uptake [m%] 7
Heat conductivity factor [W/mk] -
Flammable classification (DIN 4102) - B3 Are the boards to be laid overlapping or butted?
Number in packaging [m2/pack.] 12 Boards are to be laid next to each other without gaps, with the
Polystyrene layer corresponds to guidelines of DIN 4095 laminating material overlapping.
(DIN 4095 specification: 0,3 l/m.s in front of walls, 0,03 l/m2.s. on roofs, 0,003 l/m2.s. under paving slabs).
34 Attached filter fleece to DIN 18195/T.10.
35
www.diademroof.com www.diademroof.com
PRODUCTS PRODUCTS
LAYER COMPONENTS GEOTEXTILES LAYER COMPONENTS GEOTEXTILES

Product description VLF geotextiles enable good


The VL fleeces are geotextiles drainage and are efficient
made of polypropylene thread filters without getting blocked.
using a needle felting method. Approx. weight 100-200 g/m2.
VL PRODUCT RANGE

VL PRODUCT RANGE
VLU geotextiles are thermally
hardened and are used for
mechanical protection and to
retain water to a degree.
Approx. weight 300 g/m2.

Product name Product number VLS geotextiles are water


VLT-100 320101 retentive and protect too.
VLR-130 320601 Manufactured from a mixture
VLF-150 320201 of threads, without thermal
VLF-200 320202 treatment. Approx. weight
VLU-300 320301
500 g/m2.
VLU-500 320302
VLS-500 320402
Standards
EN ISO 11058 Water permeability
EN ISO 10319 Tensile strength
EN ISO 12236 Elasticity
EN 918 Resistence to penetration Advantages Installation instructions Packing, Transport and
EN ISO 12956 Opening width Resistant to both acidic and Remove debris and check Storage Instructions
MSZ 93-9:1985 Water retention capacity
basic substances that the surface is clean and Geotextile rolls are delivered
FLL guidelines 5.3/2002; 8.2./2002 Protecting and filter layers
Due to its elasticity sound. Roll out the geotextile on spools of cardboard,
Related pages withstands heavy weights and leave at least 100 mm protected by black
8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 on points overlap at the ends and 300 polyethylene bags, secured
Excellent water permeability mm at sides. These sheets by a cap. Transport the rolls
Easy to cut should be weighted if left laying down. Move the rolls
Application exposed. Wetting the sheets with a forklift truck or thread a
VL geotextiles have many provides a degree of weight wire through the spools and lift
different uses on green roofs but if left for longer periods with a crane.
but their main functions are sandbags or paving slabs
filtering and mechanical should be used.
protection.
Tools needed for
VLT geotextiles are made for installation
separating incompatible Sharp blade, cutter.
materials. Lighter weights are
suitable between manufactured
layers and heavier weights for
incompatible growing
mediums.

VLR geotextiles are suitable Frequently asked questions ?


for inverted roofs above the
thermal insulation layer, for Are VL geotextiles root-resistant?
both protection and filtering. Roots were meant to grow through the VL layers and by
2
Approx. weight 130 g/m . intertwining, strengthen the entire system. Mature root growth
is therefore more desirable than fresh planting.
Technical data Dim VLT-100 VLR-130 VLF-150 VLF-200 VLU-300 VLU-500 VLS-300 VLS-500
Product number 320101 320601 320201 320202 320416 320302 320405 320402 Does a VL layer have to be joined to the layer below it?
2
Surface weight [g/m ] 100 130 150 200 300 500 300 500 No, but it should be weighted against wind uplift if left
Thickness [mm] 0,8 1,3 1,9 1,9 1,8 2,5 3,0 4,0 exposed.
Tensile strength length ways [kN/m] 4,5 7,5 10 12,0 2,2 5,4 2,2 4,4
Tensile strength across [kN/m] 5,5 8,5 11 14,0 3,2 7,2 3,0 6,0
Elasticity [%] 50 / 90 50 / 90 50 / 90 50 / 90 75 / 65 75 / 65 100 / 95 100 / 95 How long can the products be stored in open air?
CBR-test N 800 1400 1750 2200 500 2300 600 3300 UV stabilized products, in general, can be exposed to direct
Durability classification GRK 2 2 3 3 1 3 1 4 sunlight for about 4 weeks.
Opening size [mm] 0,1 0,1 0,1 0,08 0,1 0,08 0,1 0,08
Water-permeability [mm/s] 90 90 90 80 90 48 90 50
Material PP PP PP PP 100% synthetic thread Up to what height should this protective layer be drawn
Thickness [g/cm3] 0,9 0,9 0,9 - 0,9-1,38 0,9-1,38 0,9-1,38 0,9-1,38 over the waterproofing?
Melting point [C] 165 165 165 - 110-260 110-260 110-260 110-260 It should fully cover and protect the waterproofing layer.
Method of production one side heat treated both sides heat treated not treated not treated both sides heat treated not treated not treated
Roll width [mm] 2000 2000 2000 2000 2000 2000 2000 2000
Roll length [mm] 100000 100000 100000 100000 50000 50000 50000 50000
Roll size [m2] 200 200 200 200 100 100 100 100
Roll weight [kg] 20 26 30 40 30 50 30 50
Roll diameter ca. [mm] 300 350 400 450 370 450 400 500
Colour black black black black multicolour multicolour multicolour multicolour

36 37
www.diademroof.com www.diademroof.com
PRODUCTS PRODUCTS
LAYER COMPONENTS ROOT RESISTANT MEMBRANE ORGANIC MATERIALS NUTRIENT SUPPLY

Product description Product description


FLW, a root resistant layer OSMOCOTE Exact is a
made from either PVC or regulated release NPK fertilizer
Polyethylene. granulate, which ensures even
growth of plants due to its
FLW 400/800

OSMOCOTE EXACT
biological activity and gradual
Product Product number nutrient release.
FLW-400 340101
FLW-800 340102
Standards Product name Product number
FLL guidelines 5.3/2002 Protector- and Filtering Layers OSMOCOTE Exact 500110
8.2/2002

Standards
FLL 11.5./2002 Delivery, upkeep
Related pages
6 7 68

Applications
Special attention should be
Installation instructions Pressing surfaces together paid to the provision of nutrients
FLW-800 at once, roll over with a to the roof garden substrate. Advantages
Cold welding: silicone roller using even The release rate of nutrients of Nutrient release meets plant Frequently asked questions ?
Both hot and cold welding is pressure these resin-encased fertiliser genus requirements
suitable for joining the granules only depend on soil Better colour of foliage and For how long will the fertiliser have an effect?
seams. temperatures and the blooms We suggest a fertiliser with a release phase of 8-9 months, as
Apply the welding agent with thickness of the covering resin. Suitable both for soft stem this corresponds with the growing season.
a brush At above 0 C the osmotic and woody stem perennials
Press the seam together Advantages / FLW-400 Applications FLW-400 pressure builds and the Even nutrient release for What are the signs of lack of nutrients?
and roll at once with a silicon Polystyrene- tar- and oil The product is particularly granules start releasing the entire growth period Shortening flowering periods are an indication. Eventually
roller resistant recommended for additional nutrients through the semi- Environmentally friendly blooming could stop altogether and a strong moss build up
Suitable for heavy duty use protection against water and permeable resin wall. The One annual application could appear.
Hot welding: as slip layer root breakthrough on extensive thicker the resin coating, the
At least a 20 mm clean and Root resistant roofs. Ideal when renovating slower the nutrient release. Application guide Could damage be caused by overdosing?
dry overlap is necessary Large, 6 25 m pieces smaller garage roofs or Nutrient release is not Application depends on Even a 20-30% overfeed of Osmocote Exact fertiliser causes
Allow the material to warm outbuildings and a perfect influenced by water content, current levels of nutrients in the no demonstrable damage.
up Advantages / FLW-800 answer for lining planting beds. PH or bacterial activity and soil, as well as the type and
Lead the welding nozzle Root resistant remains constant in purpose of the green roof
over the 20 mm overlap and Easily installed Installation instructions changeable environmental installed. At the start and during
pay particular attention to the FLW-400 conditions. subsequent applications
edge of the upper layer. (The Ensure a 1.5 m overlap at all 60 g/m Osmocote Exact
nozzle must also travel 2-3 seams. Product accessories Standard fertiliser should be
mm beyond the edges to be Hand driven fertiliser spreader used for intensive green roofs
joined) and 35 g/m for the extensive
types. Best time for fertilisation
is March, the beginning of the
growing season. Using the
Technical data
Product number
Dim FLW-400
340101
FLW-800
340102
Frequently Asked Questions ? hand driven spreader, an even
Approx. thickness [mm] 0,4 0,8 distribution of fertiliser can be
Material PE-LD PVC-P Does the root protection layer need to be protected in ensured with 2-3 light
Colour black brown turn? applications.
Weight [kg/m2] 0,37 1,03 Yes, with protection fleece.
Tensile strength weft N mm-2 >20 24,3
Tensile strength warp N mm-2 >18 23,0 Tools needed
Elasticity weft % >500 365 How can one be sure about the protection a product Hand driven fertiliser
Elasticity warp % >600 359 offers against roots growing through? spreader
Tear resistance weft % >75 95 The FLL carries out tests after a 2 year, and a 4 year period for Weighing scales
Tear resistance warp % >85 90
root penetration. Certificates are given only after these tests are
Cold folding - without cracking
Diffusion resistance 8506
completed.
Test for root breakthrough 8506
Test reports to Standards DIN 16938 DIN 16938 What are the recommended uses for the
FLW-400 layer?
Quality standard ISO 9001, ISO 9014
Other observations rolled not UV or bitumen
The use of FLW-400 is recommended on roofs where
4-ply resistant conventional waterproofing is applied for instance on green
Width of roll [mm] 1500 1300 roofs that are installed on garage decks. Due to its excellent
Length of roll [mm] 2500 3500 vapour resistance properties and its high tensile strength
Surface area of roll [m2] 150 45,5 qualities, it may also act as a vapour control layer on the warm
Weight of roll [kg] 56 47
Diameter of roll approx.[mm] 330 211
side of any thermal insulation.

38 Pallet units roll / pallet 20 22


39
www.diademroof.com www.diademroof.com
PRODUCTS PRODUCTS
HYDROTECHNOLOGY INSPECTION BOXES HYDROTECHNOLOGY INSPECTION BOXES

Product description 300


The KSE inspection box is 320
manufactured from recycled 10
plastic.

20
KSE 10/15/20/30

KSE 10/15/20/30
180

200
180
190
Product name Product number

10
KSE 10 110111
KSE 15 110112 340
F 3,5 x 35 F 3,5 x 35
KSE 20 110113
KSE 30 110114
Standards
EN 124:1999 load bearing 340
FLL guidelines 5.5./2002 gutter system F 3,5 x 35 F 3,5 x 35
P 4,8 x 18 320
Related pages

10
9 16

Applications

P 4,8 x 18

320
300

340
The KSE products ensure the
draining of green roofs and
the maintenance and
inspection of the water outlet
is unhindered. These
products are suitable for P 4,8 x 18
installing an irrigation system, F 3,5 x 35 F 3,5 x 35
positioning a water level 300
regulator and storing
accessories. By using a 100
mm extension ring, the depth
of the growing medium can Advantages Installation instructions Tools needed for
be matched. Chip and UV resistant Warm roof: The installation
material inspection boxes are No special tools required.
Can be used with various
simply placed over the
water-draining systems, Product accessories
including drainpipes rainwater outlet. Thermal cover
Lockable Inverted roof: The KSE
Filters water entering the inspection boxes in this Cast iron cover for heavy
system case can be placed on traffic areas
Keeps sunlight out of the the top of insulation.
drains
Suitable for all types of
General: The drainage
green roof outlets boards and fleeces should
be taken to the edge of the
inspection box.

Frequently asked questions ?


Why is the use of inspection boxes recommended for
green roofs?
The most ideal conditions for plants on a green roof are near
the water outlets and this product enables both inspection
and maintenance without dismantling any parts.

Why is a gravel strip needed around the manhole?


Technical data Dim KSE-10 / 15 / 20 / 30 KSE+extension element By constructing a gravel strip vegetation can be kept at a
Product number 110111 / 110112 / 110113 / 110114 100211 distance from the outlet which greatly helps draining surface
Width [mm] 300 300 water.
Length [mm] 300 300
Height with cover [mm] 100 / 150 / 200 / 300 100
Outlet surface area
2
[mm ] 900 - What should determine the chosen height of the
Fixing quality standard DIN 7505 A2 DIN 7505 A2 product?
Drain pipe connection 4 pieces, d=52 mm - The uppermost point of the inspection box should be 10-20
Drain pipe clamp part of construction - mm above the surrounding area with or without a cover plate,
Heat-insulated cover can be ordered (30 mm extruded PS) -
to prevent blocking the interior with debris.
Lid can be ordered (height 100 mm) -
Transport packaging on pallets: 2 items of KSE-10/box in cardboard boxes
Material PP PP

40 Colour See: RAL chart 7032 7032


41
www.diademroof.com www.diademroof.com
PRODUCTS PRODUCTS
HYDROTECHNOLOGY INSPECTION BOXES HYDROTECHNOLOGY INSPECTION BOXES

Product description
400 400
The KSR inspection box is KSR-65
manufactured from recycled

128,87 182,25 128,87


125
plastic. KSR-55

20
KSR 35/45/55/65

KSA 10/15/20/30
KSR-45 350

150

440
20
KSR-35

650
550
Product name Product number

150
450

20
KSR 35 210111

350
KSR 45 210112
KSR 55 210113 440

150
KSR 65 210114
Standards

5
MSZ EN 124:1999 load bearing
EN 1433:2002
DIN 19580
FLL guidelines 5.5./2002 gutter system
Related pages
21 27

95
Applications
The KSR inspection unit R2

100
150
200
300
6
enable unobstructed water
drainage, inspection and easy
350
cleaning of rainwater outlets.
These products are also 375
suitable for installing an

KSR 35/45/55/65
60
irrigation system by
positioning a water level

348
228

320
regulator and storage
accessories. By using a 50
mm extension ring, the depth

60
of the growing medium can 100
be matched.

Product description Application Installation instructions


The KSA inspection box is KSA products are especially Inspection boxes can be
Advantages manufactured from recycled designed inspection boxes for positioned directly above the
Can be used on any type of plastic. simple intensive and also for drainage boards when they
green roof with any type extensive green roofs with have enough capacity. Using fill
of outlet external down pipes located at up systems however, they must
UV resistant the parapet. They ensure clear be positioned on the
Lockable access to the drainage mechanical protector layer. In
Accepts fittings for irrigation system. the latter instance drainage can
systems be hastened by placing looped
Filters entering surface drainpipes in the immediate
water vicinity of the manholes. On
Stops sunlight getting into inverted roofs the inspection
the outlet Frequently asked questions ? boxes are placed on the
thermal insulation layer and a
KSE or KSR inspection boxes? separating layer is used to
KSE products are manufactured for up to 300 mm total layer create the gravel division
thickness. Above this thickness the use of KSR is advised pocket around it. Care must be
because of the product's superior ability to withstand taken with the filtering layers
pressure to the sides. around the manhole and it is
advisable to bring up all
Technical data Dim KSR-35 / 45 / 55 / 65 KSR+ext. element KSA-10 / 15 / 20 / 30
Why is a gravel strip needed around the manhole? geotextiles right to the edge of
Product number 210111 / 210112 / 210113 / 210114 100202 110211 / 110212 / 110213 / 110214 By constructing a gravel strip because vegetation can be kept the manholes.
Width [mm] d=400 d=400 300 at a distance from the outlet and this also greatly helps the
Length [mm] - - 350 draining of surface water. Tools needed for
Height with cover [mm] 350 / 450 / 550 / 650 100 100 / 150 / 200 / 300
installation
Outlet surface area [mm2] 900 - 900
Fixing quality standard DIN 7505 A2 DIN 7505 A2 DIN 7505 A2
What should determine the chosen height of the No tools are needed to put this
Drain pipe connection 4 pieces, d=52 mm - 4 pieces, d=52 mm product? product in position.
Drain pipe clamp part of construction - part of construction The uppermost point of the inspection box should be 10-20
Thermal cover can be ordered (30 mm extruded PS) - can be ordered (30 mm extruded PS) mm above the surrounding area with or without a cover plate, Product accessories
Lid can be ordered (KSR+) - - to prevent blocking the interior with debris. Thermal cover
Transport packaging on pallet in box in box on pallet in cardboard box
Material PP PP PP
Lid
Cast iron cover for heavily
42 Colour RAL 7032 7032 7032
trafficked areas 43
www.diademroof.com www.diademroof.com
PRODUCTS PRODUCTS
HYDROTECHNOLOGY WATER DRAINAGE CHANNELS HYDROTECHNOLOGY WATER DRAINAGE CHANNELS

Product description
The RNH drainage channels Operational
are manufactured from diagram
recycled plastic with 1000 The casing of RN
galvanized steel or stainless 170 660 170 drainage channels is
RNF 5/8/10

RNF 5/8/10
steel grille cover. made of polypropylene

80

60
with an open underside
140 290 140 290 140 to ensure great durability
Product name Product number and good drainage
RNH 8-12 210201 properties. Rain (A)
RNS-03 210305 1000 entering the channel
RNS-05 210301 passes along not only
RNS-08 210302 lengthways (B) but also

115
RNF-05 210101

143
sideways (C) toward the

80
LOGO

RNF-08 210102
RNF-10 210103
drainage layers and the
140 290 140 290 140 down pipes.
Related specifications
MSZ EN 124:1999 load bearing
EN 1433:2002 technical components of surface water draining 143
DIN 19580 drainage
FLL guidlines 5.5./2002 gutter system
1000
Related pages

138
15 17 23
RNS 3/5/8

RNS 3/5/8
Applications
The RNH drainage channels
should be positioned along
terrace doors, low windows A
and at terrace-wall junctions.
Their use should particularly
be considered, where there
are large vertical surface areas
as these also transfer a
substantial amount of
rainwater.
C B
RNH 8/12

RNH 8/12
EVENAS
Stainless
Steel
Advantages Installation instructions
Low installation profile The channel can be laid Frequently asked questions ?
Easy to clean beside or on the top of the
Strong polypropylene drainage board. Channels are Why is the underside of RNH products left open?
housing strengthened and stabilized An open underside to these products ensures fast water
Adjustable height by overlapping the top grille to drainage both lengthways to a drainage pipe and sideways to
Two way drainage connect the channel. the drainage boards.
Additional stability can be
Product accessories achieved by fixing channels Steel or polypropylene channel housing is best?
Corner piece together if necessary. Care The advantage of polypropylene channel housing is good
End piece should be taken to ensure any stability, durability and low heat conduction. The latter protects
Connecting element cut galvanized steel sections the watercourse from thermal damage. Steel housing could
are sprayed to prevent be used when only very small height is available for
corrosion. installation.

Tools needed for Which type of grate to choose?


installation The mesh-type grate is most suitable for places with high splash
Screwdriver back of rain, and the ribbed grate type is most suitable where
Rubber mallet low overall height is a problem. The cast iron grate has the best
Technical data Dim RNH 8-12 RNS-03 / 05 / 08 RNF-05 / 08 / 10 Metal cutter load bearing characteristics.
Product number 210201 210305 / 210301 / 210302 210101 / 210102 / 210103
Height [mm] 80-120 adjustable 30 / 50 / 80 50 / 80 / 100
Width [mm] 145 135 150
Length [mm] 1000 1000 1000
Type of grate galvanised steel, mesh size: 40x10 mm die-stamped grating cast iron mesh
Type of channel casing PP, RAL colour: 7032 PP, RAL colour: 7032 PP, RAL colour: 7032
Durability classification A15 A15 A15

44 Stainless steel finish optional optional optional


45
www.diademroof.com www.diademroof.com
PRODUCTS PRODUCTS
HYDROTECHNOLOGY TERRACE OUTLET COVERS HYDROTECHNOLOGY TERRACE OUTLET COVERS

Product description
The TRH terrace outlet cover
is manufactured from a
recycled plastic base with 300
300 (400/500)
optional steel height
(400/500)
TRH 30/40/50

TRH 30/40/50
adjustable element and grille
cover.
65 170 65
(270/370)

110

70
80

80
R26
Product Product number
TRH-30 210601
TRH-40 210602 50 200 50 300

10
TRH-50 210603 (300/400) (400/500)
Related specifications 300 300
EN 1433:2002
(400/500) (400/500)
DIN 19580
MSZ EN 124:1999
FLL guidelines 5.5./2002
Related pages

(400/500)

(400/500)

(400/500)
20 23 25

300

300

300
Application
TRH grated outlet profiles
enable the multiple-plane
water-draining of roof terraces.
Access for inspection and 50 200 50
EVENAS (400/500)
cleaning of roof outlets is
Stainless made simple.
Steel
Advantages Installation instructions Tools needed for
Suitable for all terrace Place the terrace grille installation
outlets centrally over the rainwater spanner
Safe for pedestrian traffic outlet on the top of the rubber hammer
Sturdy plastic frame drainage layer. The grille steel saw
Fits flexibly to local height should be placed prior to the leveller
conditions laying of the paving. Cutting
Can be ordered in stainless should be kept to the Product accessories
steel minimum. Stainless steel construction

The vandalism resistant


solution
TGS is used to ensure
unobstucted water drainage
as well as professional
maintenance of the water
outlets. TGS also protects the
outlets from severe external
effects. TGS products can be
used on both public places
and places where there are a
heavy traffic of lighter vehicles.
Frequently Asked Questions ?
What is the load-carrying capacity of cover plates?
Technical data Dim TRH 30 TRH 40 TRH 50 TGS 30 TGS 40 TRF covers can be used on terrace surfaces with pedestrian
Product number 210601 210602 210603 140301 140302 traffic. They conform to loadability class A15.
Height [mm] 80-120 (special size on demand) 150 200
Width [mm] 300 400 500 300 400
Length [mm] 300 400 500 300 400
Can they be ordered in stainless steel?
Type of grate galvanised or stainless steel grills cast cover grate cast cover grate Yes, the grids can be ordered in hot-dip galvanized or
Grid grating [mm] 4010 5200 5300 stainless steel.
Grid body UV resistant PP
Drain pipe connection 4 db, d=52mm (only above 5 cm height)
Drain pipe clamp only above 5 cm height
What tool is needed for setting the height?
A leveling board and a fork wrench are needed for the task.
46 47
Adjustability galvanised slipper insert, steplessly adjustable in 4 cm zones
Colour RAL 7032

www.diademroof.com www.diademroof.com
PRODUCTS PRODUCTS
HYDRO TECHNIQUE TERRACE GRILLES HYDRO TECHNIQUE TERRACE GRILLE UNIT

Product description Product description


The TRS doorstep grille is Height-adjustable, hard plastic
manufactured from recycled outflow pipe with stainless steel

plastic with a choice of steel grille.

grille cover. The TRS terrace


TRS 60/75/100

BLH 30
Product name Product number
TRS-60 210403
TRS-75 210404 Product name Product number
TRS-100 210405 BLH-30 220106
Related specifications Related specifications
MSZ-04-134 Drainage of Buildings MSZ-04-134 Drainage of Buildings
MSZ EN 124:1999 Installation of gullys MSZ EN 124:1999 Installation of gullys
DIN EN 1433:2002 DIN EN 1433:2002
DIN 19580 Drainage DIN 19580 Drainage
FLL Guidlines 5.5:2002 Drainage facilities FLL Guidlines 5.5:2002 Drainage facilities
Further pages Further pages
26
18

grille is available in three Applications


different sizes each of which These units are suitable for
can be ordered in individual collecting surface water into the
heights. The grilles can be main draining system even on
supplied with or without a those roof terraces, which are
Applications Installation instructions w e l d e d c o l l e c t i o n t r a y. built of many layers.
External door entrances. The grille should be placed on Drainage can be direct to the
the top of the drainage layer. outlet or into the drainage Installation instructions
Removal of the four small layers. The product ensures no After laying a protection fleece Diagram
circular pre-cut sections at the slipping no soiling and less upon the waterproofing, the The excess surface
base of the grille will allow splash marks near doorways. adjustable terrace grille should water will drain through
drainage directly into drainage be placed over the rainwater the stainless steel grill.
layer. Alternatively the large Advantages outlet. Care should be taken to
central pre-cut circular section Three heights available ensure that the adjustable
can be removed and the grille The version without a bottom element does not block the
located directly above the tray enables drainage into a outlet. Once final height
rainwater outlet. water drainage layer adjustment has been made the
Changeable mud brushes paving can be laid and should
Frequently Asked Questions ? for shoe cleaning form a tight butt joint to the unit.
Easy to clean
Where should the large grilles be used and where the Long lasting hard plastic
smaller ones? housing
In front of terrace doorways a small grille is insufficient in a Mesh available also in
downpour and generally speaking one should always use the stainless steel
large sizes for safety. Any grilles with trays which need to be Advantages
plumbed in must also be the larger type. The smaller ones Robust stainless steel
should only be used where space is limited. Accessories 150 150 mm grille
Drainage outlet pipe Quick and easy installation
Are shoe cleaning brushes replaceable? and maintenance
Grille inserts are attached by steel clips. The cleaning brushes Suitable for connecting
are exchangeable by releasing the clips and repositioning them drainage network to main
after replacement. drainage
Can be set flush with paving
Can I order stainless steel grilles? Evenly adjustable height
Grilles are made of galvanised steel but can also be ordered in between 72 and 300 mm
stainless steel versions. Prevents birds nesting in
Frequently Asked Questions ? drains
EVENAS When should the Terrace Grille Unit be used?
Stainless Wherever positive surface drainage is required on a multi layer
Steel build up.

How can the height adjustable element be shortened?


This can be shortened by simply cutting to size with a
Technical data Dim TRS-60 TRS-75 TRS-100 hacksaw. Technical data Dim BLH-30
Product number 210403 210404 210405 Product number 220106
Length [mm] 600 750 1000 Can one inspect the state of the drain below the grille? Height [mm] 72-300 infinitely variable
Width [mm] 400 500 500 Yes, the grille is kept in place by four stainless steel screws in Grill size [mm] 150 150
Height [mm] 50-upwards 50-upwards 50-upwards Supporting base plate size [mm] 250 250
the corners, in the pre-drilled holes. These can be unscrewed
Grill mesh size [mm] 40 10 40 10 40 10 Grille material stainless steel
Material of housing UV-resistant polypropylene and replaced after inspection. Base plate material polypropylene

48 Material of grille hot-dip galvanised steel or stainless steel Outer diameter of threaded pipe [mm] 1250
49
www.diademroof.com www.diademroof.com
PRODUCTS PRODUCTS
HYDROTECHNOLOGY AUTOMATIC IRRIGATION SYSTEM HYDROTECHNOLOGY AUTOMATIC IRRIGATION SYSTEM

Product description
This Complete Rainwater Operational
Management System provides skeleton diagram
0!
an economical and convenient The operating features
solution for irrigating green of the system is the
DIADEM COMPLETE RAINWATER MANAGEMENT SYSTEM

DIADEM COMPLEX RAINWATER MANAGEMENT SYSTEM


roofs in an ecological way. water-level controll
valve (A), which in case
Product Product number of lower water level
Mechanical water-level controller 040301 A1 permits the floating on
Overflow element 100138 the roof from the
pipelines, or from the
D
Related specifications reserving tanks (C). The
FLL guidelines 4.8/2002 draining B task of the lock cap (B)
FLL guidelines 4.9/2002 watering is to adjust the water
FLL guidelines 6.4/2002 water storage and additional watering level, by assureing the
E drain of the excess.
Related pages
21

Application A2
The BKS Irrigation System
works on the principle of a
uniform level of water being
maintained on the roof D
surface. This is achieved by
C
constructing the roof to zero
falls. As the water level drops
this is replenished from a
separate rainwater harvesting
tank connected to the water
mains via a double check
valve. This rainwater
harvesting tank is constructed System components Advantages
specifically for each project. DHA-110 Gully with height Saving on screed to falls
The water level on the roof is adjustable cylinder costs
maintained at a predetermined DHA + Extension elemnent Frees the sewig system
level by means of an ASG40 - PVC-93 Gully for from overloading
extension piece attached to various roof outlets with Simple and quick
each outlet. This system is not 93 mm diameter installation
suitable for inverted roofs. ASG40-PVC-140 Gully for The most eficient way of
various roof outlets with utilizing rainwater both
140mm diameter economically and
Corner valve ecologically
Run through valve Irrigation without polluting
Inspection box the facade
Drainage and reservoir Reduction of airborne
board DiaDrain 60 particles
Substrate Rhyolite tufa Easy operating and
maintanance
Does not contain expensive
elements
- Exemplary rainwater
management

Frequently Asked Questions ?


What quantity of water is held?
There is standard rule, that the third part of the drainage layer
should leave clear from the floating.

Could the system be used for refurbishment?


If the falls are connected to zero falls.

Should operation continue during winter?


It should not be necessary but with an intensive roof garden
there is no danger of the water freezing.

50 51
www.diademroof.com www.diademroof.com
PRODUCTS PRODUCTS
EDGING GRAVEL BOARDS EDGING GRAVEL BOARDS

Product description
The KLS gravel boards are
available in a choice of metal or 2000
recycled polyethylene.

10
KLS GRAVEL BOARDS

KLS GRAVEL BOARDS


80 15

65
123

50
215

250
77,5 15 15 77,5

120
3 3

Product Product number

15
KLS-FF 164001

10
KLS-AL 162006
KLS-ES 163003
15 100 0,8

10
Related specification
DIN 4095 water-draining of buildings
FLL guidelines 5.6./2002 Connecting piece
Related pages

80

77,6
9 10 11 12 16 21 27
10

90

90
0,8


15
Application 120 117,6
The KLS gravel boards create
a vertical separation of the roof
garden elements and act as a
support at exposed edges.

Advantages Instalation instuctions Tools needed for


No need for bedding The separating profile installation
Can be quickly constructed elements are laid butt jointed Tin-ware handtools for cutting.
Does not prevent water and butt straps used for
draining connecting one piece to Product accessories
Long-lasting another. Joint items

Frequently Asked Questions ?


Which side is to be built in?
This will depend on the height required, 8 cm or 12 cm.

How can they be fastened?


The weight of the substrate provides sufficient stability against
the movement of the product.

Corner formation?
Formation of 90 corners can be done with special corner pieces
Technical data Dim KLS-FF-8/12 KLS-ES-8/12 KLS-AL-8/12
or by cutting on site.
Product number 164001 163001 162006
Element length [mm] 2000
Foot size/element width [mm] 80
Height [mm] 120
Material thickness [mm] 0,8 1,50
Mass [kg] 1,40 1,40 1,20
Colour -
Material hot-dip galvanized steel stainless steel aluminium
Water drainage [mm2] 9000
Accessories binding elements, needed: 1 pc/2 r. meter

52 53
www.diademroof.com www.diademroof.com
PRODUCTS PRODUCTS
EDGING RECYCLED PLASTIC KERBS EDGING RECYCLED PLASTIC KERBS

Product description
The RD product range of
edge kerbs are manufactured

120
from recycled plastic with a
variety of finishes available.
RD PRODUCT RANGE RDL/T 12/19

RD PRODUCT RANGE RDA 25/40


190
Product Product number
RDL-12 160201
RDL-19 160202

190
RDA-25 160301
RDA-40 160302
Standard
FLL guidelines 5.11./2002 edging 1150
Related pages
12 13

190 100 10
Application
RDL and RDA edge pieces
can be used, in the edging of

250

250
terraces and green roofs. They
are important distinctive
pieces in the development of
a garden layout. In addition 300 16 359 16 358 16 359 16
these units can be used to
1150
house, trunking for electrical
cabling. For decorative
purposes lighting can be

1150
Installation instructions Advantages installed.
To secure the continuity of No local concreting needed
water drainage, a level and Quickly constructed
compacted base made up of Long-lasting
mineral rubble is made on a Related products
heavy duty DIADRAIN layer on Tools needed for RDL-UNI (12)
to which the RDL kerb is then installation Corner unit
placed. Preformed corner General garden-building
pieces are available. For tools
stability metal capping profiles Screwdriver
are slipped on to the top of
the kerb. This also allows Product accessories
continuous jointing of the Stainless steel connecting
pieces. screw
Front-piece coloured
according to RAL colour

Frequently Asked Questions ?


What provides product stability?
A properly prepared base as described in Installation Instructions will provide the necessary
stability. This can be enhanced by screw fixing one kerb to another.
Can the product be ordered in different finishes?
Yes, simply specify the RAL colour and finish required.
What is the purpose of the metal profile on the upper edge of the product?
The profile, allows connection of neighbouring kerbs.
Corner-forming?
Technical data Dim RDL-12 RDL-19 RDA-25 RDA-40 RDT-12 For the forming of 90 corners RDL-UNI products are available to form internal or external
Product number 160201 160202 160301 160302 160401 corners.
Element length [mm] 1150
Width [mm] 190 240 300 480 190 Local cutting?
Height [mm] 120 190 250 400 180 With traditional woodworking tools pieces can be cut to the required size.
Mass [kg] 6,1 8,14 11,00 17,80 6,5
Outside corner (L W H) [mm] 1150 190 120 1150 240 190 300 300 250 480 480 400 1150190180
Inside corner (L W H) [mm] 1150 190 120 1150 240 190 600 600 250 960 960 400 1150190180
Colour black (anthracite)
Material Recyl. PS

54 55
Outside surface rhombus pattern
Frost resistance yes

www.diademroof.com www.diademroof.com
PRODUCTS PRODUCTS
EDGING CONCRETE KERBS EDGING CONCRETE KERBS

Product definition
BW, edge kerbs are manufac- BW-100 BW-80 BW-60
tured from precast concrete.
BW 30/40/50/60/80/100

BW 30/40/50/60/80/100
1000

800

600
Product Product number
BW-30 161002
BW-40 161006
BW-50 161013
500 400 400
BW-60 161003
BW-80 161004
BW-100 161005

400

400

400
Related specifications
DIN EN 13198:2003 Frost resistance
NORM B - 12517/2000 Load-bearing capacity
NORM B 3254 Experts' opinion on stability
FLL guidelines 5.11./2002 Edging
Related pages
18 20 22 25
BW-50 BW-40 BW-30

Application

500

400
BW edge pieces can be used

300
for separating areas with
varying thicknesses, for
supporting higher 400 400 200
superstructures and for the
formation of separate garden
areas.

400

400

400
Advantages Installation instructions placed directly after leveling
No local concreting needed To secure the continuity of and compating. For forming of
Can be constructed quickly water draining, a bedding corners separate corner
Long-lasting made up of mineral rubble pieces are also available. In
with a thickness of min. 5 cm case of direct edging of
and with grain sizes of 4-8 covers, joints between the
mm is to be made on a pieces are to be closed with a
heavy-duty drain layer on long-lasting flexible bitumen
which the elements can be strip, thus discolouring of the
cover can be avoided.

?
C

Frequently Asked Questions Tools needed for


installation
A Which side is up? General garden-building tools
B

According to stability experts, the product can be laid on either


side. Related product
Self adhesive Bitumens strip
How are the concrete kerbs fixed?
Technical data Dim BW 30 BW 40 BW 50 BW 60 BW 80 BW 100 Concrete kerbs do not need to be fixed when both sides are
Product number 161002 161006 161013 161003 161004 161005 supported e.g. where paths adjoin planted terraces or where
Element length (A) [mm] 400 400 400 400 400 400 you have on one side the vegetation medium and on the other,
Foot width (B) [mm] 300 / 200 400 400 400 400 500 gravel, or other material. In this situation the gritted bedding
Height (C) [mm] 200 / 300 400 500 600 800 1000
and the weight of the growing medium on the kerbs provides
Thickness [mm] 60 80 70 70 100 100
Mass [kg] 25 55 64 72 96 126
sufficient stability against the movement of the kerbs.
Concrete quality C25
Frost resistance yes Construction of corners?
Requirement [pc/rm] 2,5
It is simple to construct 90 degree corners by using
Feature concrete product manufactured with pressed technology
Loadings recommended for gardening applications combinations of interior and exterior corner elements.
Outside corner can be ordered
Colour grey grey grey grey grey grey

56 Packing pc / pallet 40 24 24 24 12 6
57
www.diademroof.com www.diademroof.com
PRODUCTS PRODUCTS
TERRACE BUILDING ADJUSTABLE-HEIGHT PEDESTALS TERRACE BUILDING ADJUSTABLE-HEIGHT PEDESTALS

Product description
SLH, height adjustable Assembly
pedestals are manufactured
from recycled plastic. P1-P4
SLH 50-600

SLH 50-600
T1 T2 T3 T4

B1 B2 B3 B4
P1=32-50 mm P2=50-75 mm P3=75-120 mm P4=120-200mm
Product Product number
SLH-50 610108 Use of C1 cap
SLH-75
SLH-120
SLH-200
610105
610104
610106
+ T3 = P6

SLH-270
SLH-310
610109
610110 +
SLH-400
SLH-500
SLH-600
610111
610112
610113
B4 C1 + T4 = P7

Related standards
FLL guidelines 5.12./2002 Forming of walkable covers Special heights with the lining of C1 cap
Related pages
20

T3
Application
Ideally suited for situations C1
where varying degrees of
height adjustment is required B4 T4
in order to achieve a level P6=190-270 mm
deck. T4 C1

T4 C1 C1

T4 C1 C1 C1

C1 C1 C1 C1

B4 B4 B4 B4
P7=240-310 mm P8=300-400 mm P10=350-500 mm P12=420-600 mm

Advantages Installation instructions Tools needed for


Easily assembled First, from the feet with pre-set installation
Good load bearing capacity heights one should place one Level board and tools
Minimal additional weight in every corner point of the set necessary for making of
Eases rainwater runoff area, then prescribed height is covers.
to be set with a level board.
Pieces in-between can be
divided, for example, along a
tightened string and also set
the height at the same time. Frequently Asked Questions ?
After placing the pillows there
is still a possibility for fine At what distances should feet be placed?
adjustments, then the level Statical measurements can give exact data in connection with
can be set with the help of a needed supports, on plank terraces with private traffic pillows
chipboard screw. are sufficient to be supported, in general, at every 70 cm.

Should the supports be fastened to structures?


Product Adjustable Supporting Not necessary, but it can happen in special cases. In these
Foot cup Cap cases it is better to fasten the head piece instead of the foot
name height (mm) surface
SLH-50 32-50 B1 1 - - T1 1 base.
SLH-75 50-75 B2 1 - - T2 1
SLH-120 75-120 B3 1 - - T3 1
SLH-200 120-200 B4 1 - - T4 1 With modular covers how can the support of points
SLH-270 190-270 B4 1 C1 1 T3 1 different from the raster be solved?
SLH-310 240-310 B4 1 C1 1 T4 1 This question appears with modular terrace covers and
SLH-400 300-400 B4 1 C1 2 T4 1 difficult-to-solve situations can arise.
SLH-500 350-500 B4 1 C1 3 T4 1
SLH-600
Ask your dealer for a detailed construction guidelines booklet.
420-600 B4 1 C1 4 T4 1
58 59
www.diademroof.com www.diademroof.com
PRODUCTS PRODUCTS
TERRACES CROSS SPACERS TERRACES CROSS SPACERS

Product description
The FK cross spacers are
manufactured from recycled 1. 2.
plastic and are available in
different sizes.
FK 1.5 -10.0

FK 1.5 -10.0
Product Product Number
FK-1,5 610114
FK-3 610102
FK-5 610101
FK-10 610103
FKU-5 610121
FKK-1,5 610116
FKK-3 610117
FKK-5 610118
FKK-10 610119
Related standards
DIN 4095 water-draining of buildings
Building guidelines 3. 4.
FLL 5.12./2002 Formation of walkable covers Mkdsi vzrajz
Operational skeleton
Related pages Az diagram
FK fugakereszt csa-
ld ismertetje,
One distinctive feature
hogy azof
17 18 23 26
egyik
the FK szr
joint cross
egy gyen-
family
gts
is thatmentn
one stalk letrhet,
can be
gy egy termkkel
broken down along lehet a
szeglyek mentn,
weakened base, s thusa
mezben
we can useisthe dolgozni,
product
illetve edges,
along egy termk
in a central
alkal-
mas as
field hls-,
well asvagy
preparing
tgla-
Replacement Application kts or
net-like minta
brick-binding
elksz-
Since the Diadem joint crosses These items are used to tsre is.
patterns.
are wedge between designed, provide permanent and
it is easy to reinsert the uniform spacing between
concrete slabs. Always install walkway surfaces such as Advantages Installation instructions
the joint crosses, with the paving slabs. Po s i t i v e s p a c i n g b y t h i s The crosses should be put in
wedge on the top. means enables a speedier place as the paving progresses
installation which will also have with the wedge shape
a more aesthetically pleasing uppermost. Ends and corners
finish and ensure even can be accommodated by
drainage. snapping off the unneeded
section of the cross.

Technical data
Product number
Size (L W H)
Dim

[mm]
FK-1,5
610114
FKK-1,5
610116
FK-3
610102
FKK-3
610117
FK-5
610101
FKK-5
610118
FK-10
610103
FKK-10
610119
50 50 18 50 50 18 50 50 18 50 50 18 70 70 20 70 70 20 80 80 20 80 80 20
FKU-5
610121
12030
Frequently Asked Questions ?
Thickness of stalk [mm] 1,5 1,5 3 3 5 5 1 10 5 Should the joint crosses be removed after paving is laid?
Unit [pcs] 200 200 100 100 100 100 50 50 100 No.
Packaging [pcs/cardboard box] 4000 4000 3000 3000 1600 1600 1200 1200 100
Mass [kg/unit] 0,55 0,55 0,55 0,55 1,40 1,40 1,40 1,40 14
Material need * [pcs/m ]
2
4,0 4,0 4,0 4,0 4,0 4,0 4,0 4,0 4 What quantity should be ordered?
Material need ** [pcs/m ]
2
6,25 6,25 6,25 6,25 6,25 6,25 6,25 6,25 6,25 That will depend on the layout pattern of the paving.
2
Material need *** [pcs/m ] 11,10 11,10 11,10 11,10 11,10 11,10 11,10 11,10 11,10
Base material recycled PS
Does the substrate determine use of crosses?
Colour black water black water black water black water black
No.
60 * In case of 5050 cm walkable plate size ** In case of 4040 cm walkable plate size *** In case of 30x30 cm walkable plate size
61
www.diademroof.com www.diademroof.com
PRODUCTS PRODUCTS
SAFETY TECHNOLOGY RAILING SYSTEMS SAFETY TECHNOLOGY RAILING SYSTEMS

Product description
The Diadem DRS-Light is a 30-120
safety cordon system for
fencing off parts of a roof. It

30
J KNE

30
consists of modular elements,
DRS LIGHT

DRS LIGHT
the weighting of which provide
its stability. As a result,
installation takes place without
dismantling or penetrating the
roof sealing layer. The two main

685
elements the Fencing Panels
and the Planting Containers,
which provide the necessary

1100
Product Product number
DRS-Light 710501
Related specifications
IBC 1607.7.1.1/2003 Fencing systems

80 50 5
EN 795/1997 EN 795/A1 Fall-guard

Further pages
17

12
30 30

210
weighting can be erected on Advantages
the spot. The choice of Installation without
interchangeable modules and disturbing sealed roof layers
the variable length spacing Simultaneous fall-guard

50
elements (0-12 cm) enable the provision
cover of many different shapes Easy and quick installation 5 5

25
and sizes of roof garden. If the Great adaptability
installation is more than 2.5 m
from the perimeter of the roof, Installation instructions elements can be erected. Next
the product is also suitable for Before installation, the the Planting Modules should be Tools needed for
the prevention of falls. Manufacturer must approve positioned according to the installation
customer plans for the new plans. Then using the Spirit level
DRS-Light System. Excess appropriate spacers of the Tape measure
water must be prevented from Fencing Modules, the Planting Bolt wrench
Application accumulating on the load- Containers should be joined
The DRS-Light product serves bearing surface by spreading a together. To make corners,
diverse safety fencing needs of layer of at least 5 cm gritting of a Corner Modules are available.
terraces and other roof areas strong mineral base of grain The System can only be used
used by people, without the size 4-8 mm, followed by the as safety barrier. The Planting
need for penetrating the sealed necessary levelling and Containers are filled with
roof. However, at the starting compressing before the compost. A5 A3
and finishing points it must be
fixed securely to existing
masonry.

Frequently Asked Questions ? A6 A4

How is the System stabilised?


The Planting Containers stabilise the System by their weight,
and by securing the fence at starting and finishing point to
masonry.

How can individual designs be achieved?


By choosing the appropriate length (0-12 cm) of stainless steel
Technical data Dim DRS-Light
Product Number 710501
spacer elements between the Planting Containers, arbitrary
Test certificate EK Certificate of Safety Technology shapes and forms of garden or paths are achievable. The
Components Fencing Panels, Planting Containers, Corner Fence Panels, Spacers, Tie Elements, Fixing Screws spacer elements can be cut to size on the spot, all at once.
Anchorage to masonry Necessary
Length of Planting Container [mm] 900
Are there special heights of Fencing Panels available?
Width of Planting Container [mm] 350
Height of Planting Container 365
Yes, special height panels are available on demand.
[mm]
Length of Module [mm] 1000
Width of Module [mm] 350
Height of Fencing Panel [mm] 1100
Fencing Panel materiall Galvanised / Stainless steel
Planting Container material Recycled polystyrene

62 Colour See: RAL choice


65
63
www.diademroof.com www.diademroof.com
PRODUCTS PRODUCTS
SAFETY TECHNOLOGY RAILING SYSTEMS SAFETY TECHNOLOGY ROOF SAFETY FENCING

Product description Installation instructions Product description Installation instructions


The DRS safety barriers come DRS standard: (see brochure) The DIADEM ADZ is a safety The System must be installed
in two main types: DRS DRS light: Where the system fencing system comprising the onto a sealant-protected

Standard, which comprises is used as safety barriers the fencing MDE 60 H.D.P.E. base surface. First place the MDE 60

the railings and a base plans and design should be and fixing brackets. drainage trays along the line of
DRS STANDARD

ADZ ROOF SAFETY FENCING


framework onto which ballast is approved by the Manufacturer.
placed and DRS light which (see brochure p.63) Applications Product name Product number
combines the railings with NOTE: In both cases the The fencing is suitable for ADZ 710601
planters which when filled system should be set 2-5 cordoning off secure areas, Standars reference
provide the necessary ballast meters from the roof edge. can be used to prevent falls EN 795, EN 795/A1 Fall-guard
for stability. and act as a anchorage point
for personal safety.
Product name Product number
DRS-Stanard 710503 Advantages
Standars reference Installation without the planned fence and fill any
EN 795, EN 795/A1 Fall-guard
disturbing sealed layers gaps with grit. Next, measure
Simultaneous fall-guard and mark the distance between
provision posts. The post supporting
Easy and quick installation plates can now be attached
Great freedom of movement with several rivets to the MDE
on both sides of barrier trays. The rivet holes should be
Large installation units, fast pre-drilled. The fence posts
Applications Application of technology repositioning should be bolted into position
DRS-Standard is suitable for all when used especially for without tightening the nuts. The
flat roofs of up to 10 gradient, safety anchorage fencing panels can be bolted
for marking off an area and for This product is licensed as onto the posts at this stage.
fall prevention. Both types act suitable anchorage when used Only after making the finer
as full prevention barriers and or according to regulations EN adjustments to the System
lines of separation. 795 and EN 795/A1. This should the bolts be finally
necessitates that the snap-link tightened.
of personal safety equipment is Tools needed for
attached directly to the upright installation Application of technology
rods of the barrier to avoid falls. Bolt wrench when used especially for
If the system is used not only for Drill safety anchorage
Advantages fencing but also to provide Spirit level This product is licensed as
Installation without secure anchorage points, Tape measure suitable anchorage when used
disturbing sealed roof layers regulations of EN 975 must be Rivet gun according to regulations EN
Simultaneous fall-guard followed in usage. E .g. 795 and EN 795/A1. This
provision minimum distance from the necessitates that the snap-link
Easy and quick installation perimeter of the roof, use of of personal safety equipment is
Various ways to arrange warning boards and annual attached directly to the safety
checks by authorised fencing to avoid falls. If the
personnel. system is used not only for
fencing but also to provide
secure anchorage points,
Frequently Asked Questions ? regulations of EN 975 must be
followed in usage. E .g.
Can the system be placed directly onto the upper roof employment of warning boards
layer? and annual checks by
No, in most cases the System needs to be placed upon grit- authorised personnel.
filled Drainage Trays. It is necessary to have a drainage layer
below the System.

Should the Containers have a drainage layer below


them?
Yes, the Containers should be placed on 40 mm high
polystyrene Drainage Trays positioned over a filtering fleece.

Do the Containers have factory made overflow holes? Technical data Dim ADZ
Technical data Dim DRS-Standard No, the Containers are watertight. The customer can drill holes
Product number 710601
Product number 710503 Test certificate EN 795 / EN 795/A1
Test certificate
Components
EN 795 / EN 795/A1
Support Plates, Frames, Fencing Panels,
on the side of the Container or on its base for invisibility.
Alternatively the Manufacturer will make a small surcharge for
Frequently Asked Questions ? Components MDE 60 Drainage Trays, Post Supporting
Plates, Fencing Posts, Fencing Material,
Special Screws. The Plant Containers and this work. Does the Fencing system need to be fixed
Round headed, self-spreading, blind Rivets
Concrete Slabs will be charged additionally. Anchorage to masonry not necessary
Anchorage to masonry not necessary
to the building? Approx. length of module [mm] 2510
Can gates be built into the System? No, the complete system is self supporting.
Container size [mm] 500 500 350 Approx. depth of module [mm] 900
1000
Yes, it is often the wish of our clients to supply gates when the Fencing height [mm] 1230
Approx. lenght of module [mm]
Approx width of module [mm] 1000 railings are not erected directly at the roof's perimeter. Wire mesh site [mm] 50 200
Height of fencing panel [mm] 1100 Wire gauge horizontal/vertical [mm] 8/6
Fencing panel material galvanised steel Post size [mm] 60 40 1800
Container material polystyrene Post support [mm] 408 140 110

64 Colour see: RAL choice Fencing material galvanised steel


65
www.diademroof.com www.diademroof.com
PRODUCTS PRODUCTS
SAFETY TECHNOLOGY FALL ARREST SYSTEM SAFETY TECHNOLOGY FALL ARREST SYSTEM

Product description
The FLG is a combined Fall
Arrest and Lighting Protection

min. 2,5 m
system relying purely on ballast

max. 12 m
Roof edge
for its installation. Loading carpet Cable-lead
FLG 30/50

FLG 30/50
grounding
Outlet to
Product Product number
FLG-30 start, corner and end support 130085 Branching to the Counter-weight
FLG-30 intermediate support 130085 lightning conductor
FLG-30 single system 130083
FLG-50 start, corner and end support 130082 Lightning conductor
FLG-50 intermediate support 130082
FLG-50 single system 130080
Fastening and lightning
l. l. conductor cable
Related specifications Light dome
MSZ DIN EN 795 /1997 protection from falling
Holding column
Related pages Fastening and lightning
conductor cable
11 15,0 m
Threaded clamp
Fixing head
Application Loading carpet
The system is suitable for use 5,0 m Counter weight
on flat roofs with up to
5 degrees slope and having
suitable ballast with a dry weight
of not less than 80 kg/sqm.

Advantages Installation instructions


Simple construction The FLG installation requires
No need to break through the connect build up of the
roof weathering various layers and elements of
No "heat bridge" developing the system to a plan that must
Able to take on forces /stress first be approved by the
Flash and Life Guard is suitable for roofs with a corrosion-proof and rot-proof. from any direction manufacturer.
The FLG Line System is the minimum load of bulk goods APP's Flash and Life Guard Integrated with lightning
only lightning-protection of 80 kg/m2. The advantages S y s t e m : Fa l l P r e v e n t i o n , conductor system Product accessories
installation which of the combined fall and Lightning Protection and System holding column
simultaneously serves as a lightning conduction Kinetic Energy Absorption (FGH-30)
fall-prevention system. protection system are used to System has been approved to Fixing head (FGM-1.0)
Installation of the system does full advantage when they are Class E standard according to Pulling rug (FGT-180)
not require either penetration included in the initial design DIN EN 795 and 795/A1 and Weight table (FGS-1.0)
of the roof insulation or stage of the roof garden. has been patented as a Fastening and lightning
mechanical fixing to the fabric There is no maximum length registered design. The system conductor aluminium cable
of the roof. The FLG Line for the system. The "Single" must be installed to an (FGL-50)
System is held in place by its system, on the other hand, approved design and plan Fastening ring (FGSH)
own weight and may be used permits for one or several provided by the manufacturer. Squeeze clamp (FGBK)
on green, gritted, or paved independent attachment Control plaque (FGK-1.0)
roofs with up to 5 inclination. points to be placed at Directions for use
The Flash and Life Guard has particular points across the Construction help booklet
been tested against relevant roof. In this case, the minimum
standards for safety on most requirements for the roof are Tools needed for
types of superstructures and dimensions of 5m 8m. All installation
roof installations. The system system components are hammer, 18 mm puncher Frequently Asked Questions ?
scissors, underlay plank fork Should the system be fastened to the building
Part of the system Dim FLG-30 line system FLG-50 line systemr FLG-30 point system FLG-50 point system wrench no. 10 and pulling nail structure?
Anchor post: Material - stainless steel stainless steel stainless steel stainless steel with internal keying no. 8 System stability is secured by loading of the roof.
FH-30 Supporting area [mm] 250 250 250 250
Height [mm] 300* 500* 300* 500* How should the system be connected to the lightning
Locking head: FGM-1.0 Material - stainless steel stainless steel stainless steel stainless steel conductor?
Fastening and lightning Material - aluminium aluminium aluminium aluminium The system perfectly integrates the fall-prevention function
conductor cable: FLG-50 Measure (diameter) [mm] 9 9 9 9
Threaded clamp: FGBK Material - stainless steel stainless steel stainless steel stainless steel
and the lightning conductor tasks. After construction the
Measure (diameter) [mm] 9,5 9,5 9,5 9,5 system is to be tied to the lightning conductor and
Fixing hook Material - galvanised galvanised galvanised galvanised earthing/grounding - keeping to prescribed specifications -.
Fall arrest mat: FGT-180 Width [m] 5 5 5 5
Lenght [m] 50 50 8 8
What type of maintenance is needed?
Tensile strenght weft [kN/m] 11,5 11,5 11,5 11,5 The FLG fall-protection system is to be checked by a qualified
Tensile strenght warp [kN/m] 11,5 11,5 11,5 11,5 contractor every 12 months who records the inspection
2
Water permeability [l/m s] 105 105 105 105 results.
Damping-Plate: FGS-1.0 Material - recycled plastic recycled plastic recycled plastic recycled plastic
Measure [mm] 1200 1000 1200 1000 1200 1000 1200 1000
Thickness [mm] 10 10 10 10

66 * special height on demand


67
www.diademroof.com www.diademroof.com
PLANNING GUIDELINES PLANNING GUIDELINES
HOW TO PLAN AND BUILD A GREEN ROOF HOW TO PLAN AND BUILD A GREEN ROOF

40 m

0,3 m
1m
HOW TO PLAN AND BUILD A GREEN ROOF

HOW TO PLAN AND BUILD A GREEN ROOF


0,8 m
0,8 m
0,5 m

Roof exit area


0,5 m 1,00/1,00m

Wind load Resistance of the surface of Accident prevention Fire protection which are covered mostly by in front of openings looking
Because of the wind, green roofs is increasing with Any work done at height Green roofs are to be resistant low-growth plants (Sedum, to roof surfaces and around
buildings are exposed to the capability of intensive requires vigilance and strict to wild fire and radiant heat. Festuca,...) can be qualified fanglights a protecting strip
pushing, sucking and rooting of plants. We can list 3 adherence to Health and We consider - from the point only in case if they fulfill the of 0,5 m wide is to be built
frictional/shear forces and their areas according to various Safety procedures. This of view of fire protection - following requirements: out of coule gravel or out of
intensity depend on the speed strengths of wind loads: applies equally to the those surfaces resistant or growth medium, min. 3 cm concrete tables,
of the wind, its flow direction, corner areas with very high installation of a Roof Garden. hard-covered which fulfill the thick, having organic in buildings constructed
as well as the height and loads Relevant 'Work at Height' following requirements: content of not higher than with a partition-wall to each
shape of the building. Layers edge and border areas with guidelines should be followed Those intensive roof 20%, other, a strip is to be built
of green roofs are to be heavy loads at all times and only operatives gardens which are watered building parts separated by out of non-flammable
formed that during central fields with lesser with appropriate certification / and maintained regularly or fire walls where the length of material, at least 1 m wide
construction and in the loads (here proper measures training should be used. were made with a thicker soil one area does not exceed according to a horizontal
finished stage they will be are to be executed). layer, are resistant to wild fire 40 m, and material of the projection which will not be
resistant to wind loads. and are considered hard- separating structure is not now or subsequently filled
covered roofs. flammable, its height is 30 with plants.
Those extensive green roofs cm, or its width is at least 1 m,
a/8
a/8
a/8

>1,5 o
b<1,5 a

Technical data Dim


Building height [m] height < 8 8 < height < 20 20 < height
Central fields 45 75
2
Edge [kg/m ] 130 210 special solution needed
68 Corner piece 225 360
69
www.diademroof.com www.diademroof.com
PLANNING GUIDELINES REFERENCES
HOW TO PLAN AND BUILD A GREEN ROOF ZSOLT TAKCS GYR CULTURAL CENTER

and other non-desirable the burden on the rain-water


plants, draining system of the former
cut-backs for rejuvenation, building, most of the rain-
re-sowing on larger-sized water to remain on the roof,
barren areas, thus we could avoid the
HOW TO PLAN AND BUILD A GREEN ROOF

addition of plants on larger- expensive changing or

DIADEM 150 GREEN ROOF


sized barren areas, expansion of internal drains.
addition of growth medium Based on our experience on
in case of erosion, the planted part of the roof,
clearing of technical these problems disappeared.
installations of vegetation,
clearing of safety paths and So, between the two
of covered surfaces of sides does the green roof
leaves and of vegetation perform better?
which obstruct their Zs. T.: Yes, and this is to be
function. emphasized since it was an
Activities listed in the above The institution got some important part of the decision.
column are always to be breathing space. Succulents Further advantage was that
coordinated. and excitement in the also in cooling during the
cultural center. summer, in heat-conservation
In case of extensive roofs, during winter the structure is
the supply of nutrients is done Mr. Zsolt Takcs, director better, we can feel that the
during cultivation after planting of the Petfi Sndor Cultural climate is better in the green
for a predetermined time Center in Gyr, belongs to roof portion of the building.
period. The use of long- those who not only heard of
On extensive green roofs, of the predetermined soil lasting, covered artificial a green roof but could With the solving of old stoppage of any kind. There
after final cultivation and covering level. This can fertilizers is recommended, for experience in real life as an problems, did not old ones was no need for stopping or
handing-over, the natural stretch for longer than 2 years example, NPK, in doses of 5 g operator of a green-roofed come up? How expensive is reorganizing programs. Only
development dynamics of depending on the vegetation N/m2 per year. In case of house, how is it. How did it fit upkeep? once we had to fit in the
plants begin. We can planting method and on the green roofs which have few in? Do you love it or hate it? Zs. T.: We got some extra work program the lifting of materials
influence this only to a small state of development. In this nutrients, for example, Zsolt Takcs: After a long that mainly in the initial period in large quantities to the roof
extent with the help of period the securing of possessing only one layer or digestion period we got to a some weeds grew out of flying but that was only a day or two.
cultivating interferences such nutrients' supply is important with a thin order of layers, it point that we considered seeds but that was solved Construction was not a
as clear-cutting or with the primarily for the growth can be very important to do green roofs at all. Our 35 years easily. Now vegetation is problem.
elimination of certain plants. medium of one-layer green the supplementary fertilizing in old building was due for saturated and fewer such jobs
Certain species, newcomers, roofs. Checking once or twice every 2-3 years in order to renovation and of all come up. Planted seedlings are You are, users of the
tall-growing ones, the ones a year usually is sufficient to maintain the predetermined possibilities we finally selected becoming stronger. building, satisfied with the
which stifle domesticated ascertain what steps are vegetation picture and the this solution. Our financial planted roof. How did your
plants, for example, some needed to do the upkeep blossoming aspect. means did not produce for us Was the roof planted with visitors react?
papilionaceous plants work. an entire green roof, only on buds of succulent plants? Zs. T.: The people visiting us
(Fabaceae) should be At the time of post-planting about 60% of it. It also helped Zs. T.: Yes, we did not have did not really notice it. Our
eliminated at an early stage. Measures in connection and upkeep works, our determination that parallel money for seedlings, buds are plan of us able to go on to the
with upkeep and post-planting maintenance of technical with the renovation, with the cheaper, but grow slower, still roof did not get fulfilled yet.
In case of extensive green works of extensive green roofs installations is also to be purpose of eliminating in about 2 years the roof was One can not see on to the
roofs caring after the planting can be: performed. In connection with obstacles, an elevator was ready. roof. It is more interesting that
lasts up to a limited time after nutrients' supply, these, the following especially also installed which we had the cultural center is
handover, until reaching 90% elimination of tree shoots should be taken into built in a way that later it could How much chaos was surrounded by buildings with
consideration: be extended also up to the created by the 6-10 stories from where
operating capability of roof. There we will build a roof construction? Was the people indicated to us: their
irrigation and/or water terrace and first step of this is institution in operation view improved. It has a certain
draining installations located this extensive green roof. during construction? positive radiation. We also
in the roof run-offs or in Another important Zs. T.: Of course, it was in organized a conference on
inspection manholes, consideration was to lighten operation, and there was no green roofs in our center.
elimination of dirt and Among the institutions in Gyr
deposits in inspection many are interested in this
manholes, on irrigation example, some of the
equipment with drainpipes managers of kindergardens
and in run-offs, come back regularly to see
stability of edges, of surface what happens.
fixings and of other
architectural elements. Are you planning to plant
Plant parts and deposits the remainder 40%, too?
blocking the functioning of Zs. T.: We would like to
gravel fills around technical transform the remainder to be
installations, of separating a n i n t e n s i v e r o o f, a r o o f
gravel paths and of garden. We believe in the
connections and closings are realization of this, we would
to be eliminated in 2-3 year like to build there a cafe shop
cycles. with an outside terrace. If we
find a willing investor, this can
70 also be realized. 71
www.diademroof.com www.diademroof.com
REFERENCES REFERENCES
TAMS LUKCSI LAJTA HOUSING PROJECT, MOSONMAGYARVR TAMS LUKCSI LAJTA HOUSING PROJECT, MOSONMAGYARVR

A r e t h e r e a l s o o t h e r,
practical, even planning-
technological advantages of
a mass closing with a green
roof?

RAINWATER MANAGEMENT
DIADEM 750 RESIDENTAL ROOF GARDEN

T. L . : I n t h e p r o c e s s o f
planning needs of not only the
customer and builder/owners
are to be met but have to
comply with city regulations
and building standards, too.
One such a standard
condition is the average
building height. OTK source
describes more or less exactly
the method of its computation.
We got used to the fact Since we are talking of
that green roofs are built average building height, some
mainly on larger real estate facades of the building can be
investments, on office planned higher, some lower,
buildings. thus connecting points of
Tams Lukcsi architect in higher and lower masses give
Mosonmagyarvr. us excellent opportunities to
form roof gardens. That is
something we can call
planning-technological profession got specialized in fastening piece which makes
advantage. As a practical Hungary, too, so there are fastening possible without a
advantage, I would mention its professional specialists who break-through of membranes.
Do you have opportuni- such technical solutions which m2 is attached. The investor excellent architectural-physical know about green roofs. In During the regular designer
ties to try this structure on do not help the quick, direct was sceptical about selling it characteristics. planning of all green roofs, we consultations, which help
medium-sized projects, on return on investment but but the market contradicted coordinate with professionals development, new problems
family houses, on collective improve quality and create the initial pessimism. The Thus, on these surfaces of the manufacturer which always come up, a need for
housing projects? new value. Thus, also in this apartment was quickly sold we do not have to think of might even involve a sketch re-developing a junction,which
Tams Lukcsi: Fortunately project we could plan in larger and thanks to this the owner some kind of "shelling". If plan. With their help we can the manufacturer maximally
not only to try it but to use it units of a higher standard in also could participate in the the architect decides for the decide which surface we have considers in detail.
quite frequently. The start of a addition to sellable standard planning, forming of a roof green roof, how much to build extensive, on which
planning process is getting to apartments. One of such garden, then with the trouble does he/she take on intensive or flooded roof, and Can we hope that the
know the builder-owner and apartments is a second-storey participation of Mr. Gbor in solving of detailed what solutions for parts or system will be more and
for a joint effort it is apartment with nearly 100 m 2 Va r g a ( A P P ) a v e r y n i c e problems? material we should consider. more handy and complex?
indispensible to build a trustful to which a roof garden of 70 solution was created. T. L . : F o r t u n a t e l y, t h e T. L . : C e r t a i n l y. W e a r e
relationship. This is the stage Flooded sounds a bit noticing a widening of a circle
when the builder-owner can frightening. What does it of customers who are open
be made open and sensitive mean? for new things. We expect that
to new things since green T. L.: We design flat roofs more and more horizontal
roofs are still considered where in the water-holding surfaces of family houses, of
novelties. Sometimes the first layer a water surface of 2-3 smaller housing projects will
mass sketch, conception plan cm high, can continuously be be used this way, thus green
brings with it the possibility of maintained, what secures roofs will become more and
using green roofs, thus it is water re-supply in dry weather, more a part of architectural
important to familiarize the in the frost-free period, in the design. In my latest plan, we
builder-owner with green roofs winter one should drain the will use the system not only on
in the first stage of planning water with a safety valve. This horizontal surfaces, but also
with presentation of plans and solution was developed to on a half-saddle roof with a
of reference buildings. I am satisfy special needs with the s t e e p e r- s l o p e , a s y s t e m
happy to say on this that I am needed outlets, valves and supplemented with special
able to work with more and with ready-made details. elements developed for this
more builder-owners where There are typical junctions, but purpose.
there is possibility to plan-in there are system solutions for
green roofs. individual problems, too.

In the Lajta Housing If the system is that


Garden Community how did complete, how flexible is it,
it happen that a green roof how can it follow changing
was constructed? needs?
T. L.: We have been working T. L . : M a n u f a c t u r e r s
together with the investor of continuously develop their
the collective apartment products, thus, for example,
complex in the Lajta Housing APP too, widens its product
Garden Community for a long range with several new system
time with much success. He parts every year. This year, for
72 understands and accepts example, with a lightning rod 73
www.diademroof.com www.diademroof.com
PRODUCT LIST PRODUCT LIST
SUMMARY TABLE SUMMARY TABLE

SYSTEMS Part no Page LWH [cm] [kg]/unit Part no. Page


Diadem-150 Extensive roof garden ................................................................. ...............810101 ..........8 Terrace channels (plastic channel-base with hot galvanised steel or cast iron channel grating)
Diadem-350 UK Simple Intensive Roof Garden Inverted Roof ........................ ...............810202 ........14 RNS-03 /fixed height, with die-stamped grating/ ......100 13.5 03 ....3.07 / rm .....210305 ...........44

Diadem-750 Intensive roof garden with water level adjustement ................... ...............810103 ........19 RNS-05 /fixed height, with die-stamped grating/ ......100 13.5 05 ....3.52 / rm .....210301 ...........44
Diadem-1200 Roof garden on top of underground garage ............................ ...............810104 ........24 RNS-08 /fixed height, with die-stamped grating/ ......100 13.5 08 ....4.55 / rm .....210302 ...........44
Diadem My Garage .... ..................................................................................... ...............130091 RNF-05 /fixed height, with mesh/ ...............................100 15 05 ......3.75 / rm .....210101 ...........44
PRODUCT LIST

PRODUCT LIST
RNF-08 /fixed height, with mesh/ ...............................100 15 08 ......4.57 / rm .....210102 ...........44
RNF-10 /fixed height, with mesh/ ...............................100 15 10 ......4.95 / rm .....210103 ...........44
Viennese Rigole /extra wide channel/ ........................100 25 05 ......5.60 / rm .....210109 ...........44
RNH-8-11,5 /adjustable height, with mesh/ ...................100 14.5 8-12 ...5.92 / rm .....210201 ...........44
Accessories:
Half-meter long channel ......................................................... ......................... ............210304 ...........44
Connecting screw ...... ............................................................ ......................... ............026101 ...........44
Channel wall end-piece with screws ...................................... ..................0.10 / pc .....200101 ...........44
ORGANIC MATERIALS [kg]/unit Part no. Page Full channel base ....... ............................................................ ..................1.50 / pc .....200103 ...........44
Plants, plant layers, artif. fertilizer Surcharge of stainless steel (mesh) ...............................100 14 ..........2.50 / pc .....030601 ...........44
Seed grain mix ........... ............................................................ ......................... ...............500104 Surcharge of stainless steel (die-stamped grating) ......100 13,5 .........1.80 / pc .....030611 ...........44
Sedum sprouts ........... ............................................................ ......................... ...............500103 ........28 Cast iron grid .............. ....................................................100 15 .........12.00 / pc ....030701 ...........44
Ball-of-shrubs ............. ............................................................ ......................... ...............500108 ........28 Balcony outlet adjustable height
Pre-cultivated trays ..... ............................................................ ......................... ...............500109 BLH-30, stainless steel ...............................................15 15 7-30 .....3.08 / pc .....220106 ...........49
Growing-medium Doorstep grilles with, hot-dip galvanized steel or stainless steel meshed grating
SEM Extensive substrate for multilayer setting ...................... .................1000 / m .......410501 ........30
3
TRS-60 (fixed-height, with mesh) .................................60 40 5 ........6.67 / pc .....210403 ...........48
3
SRM Intensive substrate ......................................................... .................1200 / m .......410601 ........30 TRS-75 (fixed-height, with mesh) .................................75 50 5 .......10.35 / pc ....210404 ...........48
SIM Underground garage substrate for multilayer setting .... .................1200 / m .......410701 ........31
3
TRS-100 (fixed-height, with mesh) ..............................100 50 5 ......14.00 / pc ....210405 ...........48
Terrace grilles, hot-dip galvanized steel or stainless steel (fixed height)
3
SUM Germ-free roof mix,with good water permeability .................... .................1500 / m .......410801 ........31
Nutrient supply TRF-30 (fixed-height, with mesh) ................................30 30 05 .......2.35 / pc .....210501
Osmocote Exact standard artif. fertilizer /effective period: 8-9 months/.......25.00 / bag ......500110 ........39 TRF-40 (fixed-height, with mesh) ................................40 40 05 .......3.79 / pc .....210502
TRF-50 (fixed-height, with mesh) ................................50 50 05 .......5.24 / pc .....210503
LAYER COMPONENTS LWH [cm] [kg]/unit Part no. Page Terrace grilles, hot-dip galvanized steel or stainless steel (adjustable height)
Drainage and reservoir boards TRH-30 (adjustable height, with mesh) ...................30 30 08-11.5 ...3,50 / pc .....210601 ...........46
2
DiaDrain-25 drainage board form-pressed on 2 sides ........196 90 2,5 .....1.30 / m ........310125 ........32 TRH-40 (adjustable height, with mesh) ...................40 40 08-11.5 ...6,20 / pc .....210602 ...........46
DiaDrain-40 drainage board form-pressed on 2 sides ........196 90 4,0 .....1.73 / m2 ........310115 ........32 TRH-50 (adjustable height, with mesh) ...................50 50 08-11.5 ...9,70 / pc .....210603 ...........46
DiaDrain-60 drainage board form-pressed on 2 sides ........196 90 6,0 .....2.70 / m2 ........310107 ........32 Irrigation systems
MDE-60 mounting and drainage board .............................196 90 6,0 .....3.67 / m2 ........310117 ........32 Water level adjustment made of plastic ...........................30 15 ..........0.66 kg/pc ....040301 ...........50
GarDia-30 channel-type protection drainage board ............150 80 2,5 .....2.41 / m2 ........310124 ........34 Water level adjustment made of steel ...........................D=23 65 .......2.56 kg/pc ....040304 ...........50
DHA-110 ..................... ..................................................37.5 22.8 .......5.10 kg/pc ....100193 ...........50
Geotextiles LW [cm] DHA+ ............................................................................D=11 15........017 kg/pc ....100196 ...........50
VLT-100 separation layer...............................................1000 200 ........0.10 / m2 ........320101 ........36 Irrigation set
93 PVC .................................................30 30 27 .....0.80 kg/pc ....100138 ...........50
VLR-130 separation layer for inverted roof ...................1000 200 ........0.13 / m2 ........320601 ........36 Irrigation set
140 PVC................................................40 40 32 .....1.70 kg/pc ....100140 ...........50
VLF-150 filter layer for extensive green roof .................1000 200 ........0.15 / m2 ........320201 ........36
VLF-200 filter layer for intensive green roof ..................1000 200 ........0.20 / m2 ........320202 ........36
VLU-300 protection layer for extensive green roof ........500 200 .........0.30 / m2 ........320416 ........36
2
VLU-500 protection layer for intensive green roof .........500 200 .........0.50 / m ........320302 ........36 EDGING LWH [cm] [kg]/unit Part no. Page
VLS-300 protection and water retention layer (extensive) ........500 200 .........0.30 / m2 ........320405 ........36 Gravel boards
VLS-500 protection and water retention layer (intensive) .........500 200 .........0.50 / m2 ........320402 ........36 KLS-10 recycled plastic ...............................................115 1 10 .......1.69 / rm .....160501
KLS-ES-8/12 stainless steel .........................................200 8 12 .......1.40 / rm .....163003 ...........52
Root resistant membrane KLS-FF-8/12 hot-dip galvanizedt .................................200 8 12 .......1.40 / rm .....164001 ...........52
FLW-800 (thickness 0,8 mm) ........................................3500 130 ........1.04 / m2 ........340102 ........38 KLS-AL-8/12 aluminium ...............................................200 8 12 .......1.00 / rm .....162006 ...........52
FLW-400 root-resistant, vapour-closing foil ..................2500 600 ........0.52 / m2 ........340101 ........38 Edge pieces
THF welding fluid for solvent welding of pvc sheets.............. .................0.98 / liter .......080104 ........38 RDL-12 ........................ ................................................115 19 12 ......6.10 / rm .....160201 ...........54
RDL-UNI/12/ ............... ................................................115 19 12 ......6.68 / rm .....160203 ...........54
RDL-19 ........................ ................................................115 24 19 ......8.14 / rm .....160202 ...........54
RDL-UNI /19/ .............. ................................................115 24 19 ......9.30 / rm .....160204 ...........54
RDT-12........................ ................................................115 19 18 ......8.20 / rm .....160401 ...........54
HYDRO TECHNOLOGY LWH [cm] [kg]/unit........Part no. Page RDA-25 ....................... ................................................115 30 25 .....11.30 / rm ....160301 ...........55
Inspection boxes for extensive roof gardens RDA-40 ....................... ................................................115 48 40 .....20.27 / rm ....160302 ...........55
KSE-10 ........................ .................................................30 30 10 .......1.64 / pc .....110111 ...........40 RDA-25-AE /outside corner/ ........................................30 30 25 .......4.68 / pc .....160303 ...........55
KSE-15 ........................ .................................................30 30 15 .......2.19 / pc .....110112 ...........40 RDA-25-IE /inside corner/ ............................................60 60 25 .......8.66 / pc .....160304 ...........55
KSE-20 ........................ .................................................30 30 20 .......3.47 / pc .....110113 ...........40 RDA-40-AE /outside corner/ ........................................48 48 40 ......12.60 / pc ....160305 ...........55
KSE-30 ........................ .................................................30 30 30 .......4.85 / pc .....110114 ...........40 RDA-40-IE /inside corner/ ............................................96 96 40 ......22.40 / pc ....160306 ...........55
Accessories: Accessories:
KSE+ extention element, height 10 cm ......................30 30 10 .......1.20 / pc .....100211 ...........40 Stainless Steel Screws ........................................................... ......................... ............020204 ...........55
Fascia inspection boxes with lid cover Coloured coating (RAL) .......................................................... ......................... ............190102 ...........55
KSA-10 ........................ .................................................35 30 10 .......3.61 / pc .....110211 ...........43 Concrete edge kerbs
KSA-15 ........................ .................................................35 30 15 .......4.28 / pc .....110212 ...........43 BW-30 ......................... .................................................40 20 30 ......25.00 / pc ....161002 ...........56
KSA-20 ........................ .................................................35 30 20 .......5.78 / pc .....110213 ...........43 BW-40 ......................... .................................................40 40 40 ......55.00 / pc ....161006 ...........56
KSA-30 ........................ .................................................35 30 30 .......7.11 / pc .....110214 ...........43 BW-50 ......................... .................................................40 40 50 ......64.00 / pc ....161013 ...........56
Inspection boxes for intensive roof gardens BW-60 ......................... .................................................40 40 60 ......72.00 / pc ....161003 ...........56
KSR-35........................ ....................................................40 35 ..........4.61 / pc .....120111 ...........42 BW-80 ......................... .................................................40 40 80 ......96.00 / pc ....161004 ...........56
KSR-45........................ ....................................................40 45 ..........5.48 / pc .....120112 ...........42 BW-100 ....................... ................................................40 50 100 ....126.00 / pc ...161005 ...........56
KSR-55........................ ....................................................40 55 ..........6.06 / pc .....120113 ...........42 Corner pieces of concrete edge kerbs
KSR-65........................ ....................................................40 65 ..........6.92 / pc .....120114 ...........42 BW-30 AE /outside corner/ ..........................................40 40 30 ......42.00 / pc ....161008 ...........56
Accessories BW-40 AE /outside corner/ ..........................................40 40 40 ......75.00 / pc ....161012 ...........56
KSR+ extention element, height 10 cm .........................40 10 ..........0.80 / pc .....100202 ...........42 BW-50 AE /outside corner/ ..........................................40 40 50 ......85.00 / pc ....161015 ...........56
Inspection box cover, cast iron ........................................... 40 ..............11.00 / pc ....100115 ...........42 BW-60 AE /outside corner/ ..........................................40 40 60 ......95.00 / pc ....161014 ...........56
BW-80 AE /outside corner/ ..........................................40 40 80 .....127.00 / pc ...161016 ...........56
Inspection and underground garage boxes, heavy duty (square)
BW-100 AE /outside corner/ .......................................40 40 100 ....170.00 / pc ...161017 ...........56
TGS-30 ....................... .................................................30 30 30 ......11.00 / pc ....140301 ...........46
TGS-40 ....................... .................................................40 40 30 ......22.30 / pc ....140302 ...........46

74 75
www.diademroof.com www.diademroof.com
PRODUCT LIST NOTES
SUMMARY TABLE

TERRACE BUILDING LWH [cm] [kg]/unit Part No. Page


Terrace pedastals adjustable height, heavy-duty, made of recycled plastic
SLH-50 ........................ .......................................... 200 32-50 .............0.25 / pc .....610108 ...........58

SLH-75 ........................ .......................................... 200 50-75 .............0.33 / pc .....610105 ...........58
SLH-120 ...................... ......................................... 200 75-120 ............0.45 / pc .....610104 ...........58
SLH-200 ...................... ........................................ 200 120-200 ...........0.63 / pc .....610106 ...........58

NOTES
PRODUCT LIST

SLH-270 ...................... ........................................ 200 190-270 ...........0.79 / pc .....610109 ...........58


SLH-310 ...................... ........................................ 200 240-310 ...........0.89 / pc .....610110 ...........58
SLH-400 ...................... ........................................ 200 300-400 ...........1.16 / pc .....610111 ...........58
SLH-500 ...................... ........................................ 200 350-500 ...........1.43 / pc .....610112 ...........58
SLH-600 ...................... ........................................ 200 420-600 ...........1.69 / pc .....610113 ...........58
Cross spacers
FK-1.5 ......................... .....................................50 50 18 1,5 .....0.32 / 100 pc ..610114 ...........60
FK-3 ...................................................................50 50 18 3.......0.55 / 100 pc ..610102 ...........60
FK-5 ...................................................................70 70 20 5.......1.40 / 100 pc ..610101 ...........60
FK-10 ................................................................80 80 20 10......1.40 / 100 pc ..610103 ...........60
FKU-5 .......................... ............................................. 12030 ............14.00 / 100 pc .610121 ...........60
FKK-1.5 ....................... .....................................50 50 18 1,5 .....0.32 / 100 pc ..610116 ...........60
FKK-3 .................................................................50 50 18 3.......0.55 / 100 pc ..610117 ...........60
FKK-5 .................................................................70 70 20 5.......1.40 / 100 pc ..610118 ...........60
FKK-10 ..............................................................80 80 20 10......1.40 / 100 pc ..610119 ...........60
Flower containers
PGE-68 /round/ ........................................................ 50 35 .................5.25 / pc .....170201
PGE-86 /square/ ......... ..........................................70 35 35..............7.40 / pc .....170202
PGE-88 /square/ ......... ..........................................50 50 35..............6.40 / pc .....170203
PGE-110 /square/ ....... ..........................................90 35 35.............10.35 / pc ....170204
PGE-111 /hexagon/ .................................................. 70 35 .................7.45 / pc .....170205
Accessories:
Water level regulating equipment .............................................................0.66 / pc .....040301
Water level indicator ... ..............................................................................0.12 / pc .....170002
Spill-valve ................... ..................................................................................... ............170003
Coloured acc. to RAL . ..................................................................................... ............190102
Precious metal cover.. ..................................................................................... ............170301
Caster wheels for planting containers ......................................................0.05 / pc .....170004

SAFETY TECHNOLOGY LWH [cm] [kg]/unit Part No. Page


Safety railing system
DRS-Standard ............ .......................................100 100 110 .........45.00 / rm ....710401 ...........64
DRS-Light ................... ........................................100 35 110 ..........17.20 / rm ....710501 ...........62
DRS-Light-ES stainless steel ..............................100 35 110 ..........17.35 / rm ....710502 ...........62
ADZ ............................. .........................................250 6 123 ...........64.20 / rm ....710601 ...........65
Accessories:
Corner surcharge for 90 corners
Corner surcharge for individual corners
Coloured coating (RAL) ................................................................................... ............190102
Lighting protection and fall arrest system
FLG-30 start-, corner- and end-support ..................................................23.03 / pc ....130085 ...........66
FLG-30 line system .... .............................................................................21.72 / pc ....130085 ...........66
FLG-30 single point system .....................................................................19.19 / pc ....130083 ...........66
FLG-50 start-, corner- and end-support ..................................................23.33 / pc ....130082 ...........66
FLG-50 line system .... .............................................................................22.02 / pc ....130082 ...........66
FLG-50 single point system .....................................................................19.49 / pc ....130080 ...........66
Accessories:
Wall anchor...........................................................10 6.2 11 .............0.40 / pc .....100175 ...........66
Boxed personal protection equipment ...............40 28.5 19 ............7.30 / pc .....130061 ...........66
Tools for professional installation ..........................32 23 9...............1.90 / pc .....130087 ...........66

Disclaimer
No. 0804 #2702
DIADEM is a registered Trademark.

76
Illustrations and photos shown in this brochure are for guidance purposes only and no responsibility will be accepted by APP for their use in any form.
Content of this brochure is subject to change.
No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, without the prior written permission of the owner.
For specific projects please contact your DIADEM Consultant whose contact details can be found at: www.diademroof.com

www.diademroof.com www.diademroof.com

Das könnte Ihnen auch gefallen