Sie sind auf Seite 1von 8

Precast Goncrete Bollards

4 I{M L|GHTII{G
SITE / AREA
PARKING STRUCTURE
ROADWAY
Contents
Design Coordination
Features
Specif cat ons
Ordering lnformation
l
2
3
4
ABCHITECTURAL FLOOD / ACCENT Color Gu de 5
LANDSCAPE
FOUNTAIN LIGHTING
]6555 EAST GALE AVENUE
Pa Bat 1?75
C TY OF NDUSTFY. CAL]FOFN A 9] 7N9
USA
PHONE 818 / 968 5666 O 1992 K r.r L ght ng lnc
FAX 8r8 / 369 2695 ThsversionOl993

.''.''-..'
Design Coordination

Kim L ghting presents the first mean ngfu approach to concTete See Kim VBB Series
bol ards desigr coord nation between lighted and un rghted calalog for B' diameter
coff gurations The spec f er now has cor-fp ete des gn freedorn Vandal Resistant Ballards
to spec fy concrete bo ards for various s te funct or]s aiternating available with aluminum
iighted and ur qhted units as theV are needed. Kim concrete or cancrcte shafts plus
bo ards uti ze our proven 10 round and square h gh perfor matching unlighted
mance urI]ina res, cornb ned w th the finesl precast concrete all cancrete models
manufactur ng methods A un que afd s mp e nstal at on system
resu ts rn a o\,rier tota insta ed cost when compared to
poured in p ace or precast direct bur ed concrete ltol ards
The coordinated des qns can become a cohestve e ement n the
overa I s te desigf, aiding I continuity througft consistentforrn

KmLghting 1
Features
Lighted Bollards Unlighted Bollards

Top caps are heavy gauge alu


rn num rgdybracedbythe
optical assemb y. The3L" th ck
insulatron reduces heat transfer
to the top surface

Un ighted Bolard heads are I


separate castings n sold cof
Patented Opt cal Louver assem- crete Surface and co or are )
bly delivers performance lghl dert cal to the base
ng with ow brightness
Ref ectors are precis on
hydroformed with a specu ar
Alzak' f n sh and aremounted
as a one p ece assemb y. U S
Patent 4,231 080 A groove is located at the
same level as the um na re
Lum na re is fully gaskeled for base providing des gn con
weathert ghl operaton. U.L tnu ty between lghted and
sted for wet ocat ons. unl ghted conf gurations.

Bo ard head s nterna ly bo t


ed at the factory and sh pped
E ectr ca components are fac- asasnqeunt
tory mounted and prewired to
a rig d harness.

Concrete base is precast us ng Base s dentical nconstruc


steel molds wire re nforc ng, ton and f n sh to the I ghted
and sandb asted to an exposed bol ard base
aggregatef n sh. Ava able n
ratural or llutf co ored concrete.

Bo ard he ght
s contro ed by
Both ighted and unl ghted bol
bLrr a depth
lards may be instaled with any
Ne ght above pavng mater a, s nce all mount
grade can lle
rng hardware rs be ow grade
34" lo 42" I
)

Bo lards are insta led us ng


anchor bolts embedded n a
poured in place foot ng (by oth
ers). Leve ng nuts rnake nstal-
ation and algnment of the bollard
qLrick and s mp e Ny'ount ng Unl ghted Bo lards ut lze the
ident ca rnount ng haTdware
hardware must not contact soil
or other corrosve e ement.
and bolt c rcle-diameters as
the ghted bol ards. l\,4ounl ng
hardware must not contact soi
or other corros ve e efi]ent

2 Klm L ght ng
Specifications
Lishted Bollards Unlighted Bollards
O
--J ro"Da F --i 10" Dia. F-
ro, sq
,//,- ).Y I |
10" sq
./ \\ I
-I
,,,,l...V
Bori
U]TC
Da.
e \,,/pun
/ View
r
Light
Center
30"
M n. Ht.
I

30"
Min. ht.
above above
42" 42"
grade grade
Max. Hl. lVax. Ht.
above above
grade I

d
grade

16" Max
16" Ny'ax.
bur al
15" burlal
depth 15',
Bolt depth
Boil
C ircle
C rcle
Dla.
4" Min.
Concrele Dia.
footing and 4" [/in.
burial depth Concrete
conduit buria depth
ioollng
Elevation by others. Elevation by olhers.

Entire Unit (um na re and concfete base) shal lle UL sted (1or Materials Port and Cement conforms to cuTTent spec f cations
120 208.240 and 277 Volt only) andCSAcertf ed (Iat 12A,277 for Port and Cement ASTN4 C150 Type I or I Aggregates meet
and 3,17 Vo t on y) for \ et ocat ons current requirements of Specifications for Concrete Aggregales '
Top One p ece freavy gaLrge a !rar n!rn sp llning tor round bo
ASTM C33 Water w be c eaf ard free frorn de eter ous amounts oi
ards, deep drawn stamp ng for square bo ards, reta ned by two
s t,o ac ds a ka ies or organ c mater als W re lor re nforcement
conforr.rs to ASTM AT85. Stee for ogs and p ates conforms to ASTlvl
countersunk capt ve socket heao lasteners afd braced at the
A36, or A2B3 grade D.
outer edges by the opr cal assemb y .,,:, th ck nsLrlat on above
the lamp. Cure and Strength Cur ng w I a ow lor comp eton of the
hydrat on process and result n a 28 day cornprehefs ve strength
Optical Assembly Prec sron hydroforrned optica ouvers wth of not ess than 4 500 ps.
specu ar A zako f n sh, ifsta ed afd removable as a one piece
assemb y Enc osure for round bo lard s one p ece extruded clear Manulacture-Steel mo ds w be Lrsed to f sure un form and
acryl c, l."th ck. SqL.rare bol ard enc osure s labricated from r/. consistent parts. NorI] nal concrete cover over the c tcumferentia
c ear acry c w th po shed seams. w Te re rforcement w be I m n mu[r.
Luminaire Base l-leavy cast a uminum fu y enc osing bottorn of Surlace and Color Bo ard surlace w be sandblasted to
um naire. w th four screw attachrnert to concrete base. produce an exposed aggregate. Buff colored bo ards shal be cast
wth an ntegra colorcond t on ng adm xture
Socket Porce ain ',\, th nicke p ated arnp grip screw she , rated
600 volts.4KV pu se rated sockets slpp ied ior al N D lxtures Assembly Bo ard head s nterna y bolted to the base at the
factory and sh pped as a s ng e un t (Un ghted bolards on y)
Gasketing Fixture s ful y gasketed for weathert ght operat or
Ballast and Wiring Ba ast and related components are factory
Anchorage Bo ards are suppled with four stee rnount ng tabs
prew red and mounted to a r g d harness for suspens on w thin the
lor nstallat on of four ,/2 x l0 + 2 z nc electro plated L hook
anchor lrolts Each anchor bo t is supp ied with two nuts two
corcrete base For freld wire connections a sttatn te tel s pto \,\iashers and a r g d press board template
v ded under the ba ast harness Ba last s h gh power factor for
20'F start ng Shipment Bo lards wi be pa eltzed w th adequate ho d-downs
to prevent oad niovement n transit
Luminaire Finish Top cover and base cast ngs are TG C
therraroset po yester po\,!der coat pa nt app ed over a chrorarate Note: All modif cat ons ior
convers on coating Ava ab e co ors are b ack dark bronze, ight attachment ol accessories to
gray or wh te
bo ards are by others. Kim
Concrete Base Same spec I cat ons as Lrr ghted bo ards (at r ght) L ght ng recommends I eld dri -
ng for nserts to nsure proper
Caution: L ghted bo ard must be grounded accord ng to local or entatiof Respons b ty lor
codes or the Nat ona E ectr ca Code Fa ure to do so raray resu t n strLrctural nlegrity ol mod f ed
ser ous persona njLrry bollards es w th others

:a:
K.n L qht nq 3
Ordering Information

Ordering Guide 1 _ 2 3 ^"4 5

( { ( ((
L ghted Bo ard 831-10SC,/ 70HP5120/DB-P / HS/ BUF
15 '."
.a ./
^rn"o/ ..nn'P.."

Un qhted Bolard
+t
.a-/

B31.1OBRC/ NAT

Configuration
I

831-10HC 831-1oSC 831-10BRC 831-10BSC


10 Round, 10' Sqrare (J HOInO 10'Square
L ghted L ghted l.lnl oht-^d Unl ghted

I t!
- Note A ways use coated lamps rated
Electrical Mode tor un uersi or base down burning DLuminaire Finish EConcrete Finish
I r)1TGtC thermoset po yester JlSee color qu de p 5)
See page 3lor U.L and CSA certificat on for ine voltages beow powder coat pa nt.
Line line N,4a x See co or gu de p 5)
(Lamps by others) Cat No ts Watts Amps
Vo
Cat No. Co or Cat. No Descr pt on
Base
150 Wall N,4ed 150lNC 12O NA NA BL-P B ack BUF Buff co ored concrete
lncandescent A 2l LF DB-P Dark Bronze with earth{one
I00 Watt l\,4ogu Base 100MV120 120 18 1 05 resemb es Duranodic"' aggregates.
N,4ercuryVapor 100MV208 208 18 0.61 313 n co or. NAT Natural concrete with
E 23|/zCoaled 100Mv240 240 18 0.53 LG-P Light Gray white aqqreqates.
100Mv277 277 2A 0.45 WH-P White.
100MV347 347 1B 040 tl
70 Watt N,4ogu Base 70HPS120 120 88 0.85
H gh Pressure Sod um 70HPS208 208 88 0.48
E-231/2 Caaled 70HPS240 240 BB 0.42 2f Luminaire Options
70HP5277 277 BB 0.37
70HPS347 347 93 0.30
-t 60'
I00 Watt Mogul Base 100HPS120 120 118 1.50
100HPS208 208 130 0.76 Cat. No Descr ption
H gh Pressure Sod um
E 23 7, Coated 100HPS240 240
100HPs277 277
130 0.66
130 0.60
HS Houses de Shie d
lnternal 160" sh e d to -l
'100HPS347 347 el minate unwanted
130 0.44 llackight. Fnshed
70 Watt N,4ed. Base 70MH120 120 89 0.85 same co ot as r'ifi'r,
[,4eta Hal de 70MH277 277
Venture ED 17 Coated 70MH347 347
94 0 37
94 0.30
lumina re. For round
or square lghted
t+l
100 Wail l\,4e.i Base 100MH120 120 129 I 15 bol ards oniy
Metal Hal de '100MH277 277 129 0.50
.-D -7 Co. -o 100MH347 347 lz9 010 ,

4 K m Llghting
Color Guide r Photometrics

Color Guide

L efl BUF Conoret-^

R ght-Recommended
urn na re co or, DB P
Dark Bronze

Left NAT Concrete

R ght Reconrmended
um naire color LG P
L ght Gray, BL P B ack, or
WH P White (not shown)

Photometrics 150W fcandescent A 21 lF,2850 umens > 730 3.00 078 033 0t6 0.08
Roufd and square bolards 100W N4V Coated E 23rlr,4600 umens > BB0 3.40 120 050 0.26 0.15 008
have dentica opt ca systerrs. 70W HPS Coated E-23f 5985 umens > 1300 4.70 170 075 0.41 0.20 011 0.07
Al photornetncs are for coated 100W HPS. Coated, E 23rl,,8800 umens > 1700 6.50 230 095 0.50 032 016 010
amps wh ch are recommended 70W Mll. Coated, ED 17,5000 umens > 214 410 1.24 0.43 0 20 0.11 006 0.04
for these lurn na res
Vlu t p icat of factors lor
l00W MH Coated ED 17 8000 lumens 340 6 50 2.00 0.69 0.32 018 011 007
correctron of footcand es wth
o
urar naire at various mount ng Chart at rght shows ntal
he ghts hor zoniai footcandles al 36
mount rg he ght (42 overa
L ght Center
boiard height).
Mounting N,4utpy
Fle ght Footcand es by
36' 1.00 I
34' 112 q
32 127
30 144 1
I
ol
28' 165
26 192 I
=
36" 42' o
l\4ouf t fg Overa
.,oo ?oo :no "oi He ghi Herg ht
q
(L ght
Uenter to
Grade) 9)
o
o
I g
__.1

;,Ovr' [/]eta Ha de Coated


0?-456
Lonq tudina Distance n Mountinq He qhts

aoo [r,'l ooo too \OO z!" .,nO


"oa
\0o zoo joo 1,oo \ ! joo rro ooo

IU0Y,/ l'lcra lla de Coatea 100$/ Vlcrc{r!' Vapo' Coated 70v,/ HPS Coal-.d l00W FIPS Coaled

Kr.Lahtnq 5

Das könnte Ihnen auch gefallen