Contents
Pipe System - Introduction
Annexure
1 - Basic Properties of uPVC
2 - Chemical Resistance of uPVC
3 - Units of Pressure
4 - Relevant Standards
5 - Useful References
INTRODUCTION
________________________________________ INTRODUCTION
The Organization
Central Industries PLC is an ISO 9001: 2000 system certified company listed on the Colombo Stock
Exchange and a member of the prestigious Central Finance Group which is one of the Sri Lankas leading
finance houses.
The core business of the company is the manufacturing of National uPVC pipes & fittings. Possessing
over two decades of experience in polymer technology & related fields, the company has expanded rapidly,
diversifying into manufacturing, marketing and distributing an array of products related to the construction
industry. At Central Industries PLC, we are proud and competent to offer you unique products.
Products manufactured by CENTRAL INDUSTRIES PLC are subjected to stringent quality assurance tests
before they are released to the market. The customer there fore can be assured of a quality product. This is
the guarantee given by CENTRAL INDUSTRIES PLC to their customers.
The rapid advancement of the company is due to the principles of continuous improvement which have
always been an inspiration to everyone within the company.
The company markets their products to the retail trade through their extensive Dealer Network covering
the entire island through distributors.
The corporate clients are serviced by the Corporate Division. The Corporate Clientele comprises all
leading Contractors, Architects, Engineers and all stake holders in the construction industry.
Central Industries PLC is actively pursuing plans for progressive growth with view of becoming a key
player in the supply of materials and services to the construction industry
The company head office has shifted to its own spacious and customer friendly location with a modern air
conditioned showroom with ample parking facility at # 312, Nawala Road, Rajagiriya.
The Chairman of Central Industries PLC is Mr. G.S.N.Peiris who is Group Finance Director of Central
Finance PLC. The Director/CEO is Mr. Newton Wickramsuriya.
Supply
National uPVC Pipes, Fittings & Solvent Adhesives are available from stock, through an island wide
network of Dealers & through a direct to site distribution from our Projects Division. Telephone
No.0115303085
Head Office:
Central Industries PLC
No 312, Nawala Road
Rajagiriya, Sri Lanka
Tel: 5303005/0112806623
Fax: 0112806621/0115303031
www.nationalpvc.com
sales@nationalpvc.com
________________________________________ INTRODUCTION
_________________________________________INTRODUCTION
_____________________________________INTRODUCTION
_________________________________________INTRODUCTION
____________________________________INTRODUCTION
_________________________________________INTRODUCTION
GENERAL INFORMATION
________________________________GENERAL INFORMATION
Manufacturing Standard
National uPVC" Pipes and Fittings are Pipes are classified into Types according to the
manufactured in conformity to Sri Lanka Standards working pressure ratings at 29 0 C. By definition the
which are based on the standards set by the Working pressure rating is the maximum pressure
International Standards Organization (ISO). Items that the medium in the pipe can exert continuously
not covered by Sri Lanka Standards are with a high degree of certainty that failure of the pipe
manufactured in conformity to relevant International will not occur. The pipe classification is as follows:
Standards.
Material
National uPVC Pipes and fittings are
Material manufactured from unplasticized (Rigid) Polyvinyl
Chloride.
Applications
Telecommunication ducting
Special Pipe System. Tube wells
Sea water aqua culture
Irrigation systems
Sprinkler systems
Chemical plants special purpose systems
Non Toxic National uPVC Pipe Systems are ideal for potable cold water. They
conform to World Health Organization requirements for potable
transportation.
Exceptionally Smooth Mirror Smooth Inner Walls minimize Frictional Losses and discourage
deposit formation.
Non Conductive uPVC is an Integral Electrical Insulation with high dielectric strength
Fire Resistance National uPVC Pipes are fire resistant and self extinguishing.
Light Weight One sixth the weight of steel systems. National uPVC Pipes and fittings
are easy to transport, handle and install.
Size and Pressure Range National uPVC Pipe systems are manufactured in sizes ranging from 20
mm to 280 mm. Standard pressure ratings start at 250 Kpa and goes up to
1000 kPa (Class 250 to 1000)
Quick Site Jointing Cold solvent joining gives extremely strong chemical weld and rubber ring
joining gives extremely strong reliable and permanent installation without
costly equipment. Demountable mechanical joints (Flanges, repair couplings
unions and screwed joints) are also available as standard.
Longer Service Life The Calculated service life of the pipe is 50 years, with a
safety factor of 2.5
Further, consequent to the award of SLS certification in 1987, the Sri Lanka Standards Institution carries out
regular sampling and testing of National uPVC pipes to ensure compliance with SLS 147:1993.
Test Objectives and the Real Benefits to the National uPVC Customer.
Test or Observation for National Objectives
uPVC Pipes and Fittings.
Mean outside Diameter To ensure National uPVC pipes perfectly fit with National uPVC
fittings.
Wall thickness To ensure National uPVC pipes and fittings having uniform wall
thickness.
Effect of material on water quality To ensure National uPVC pipes and fittings in contact with drinking
water,
1. Should not constitute a toxic hazard,
2. Should not support microbial growth,
3. Should not give rise to any unpleasant taste or odor or to
Cloudiness or discoloration.
To ensure National uPVC pipes and fittings withstand sulphuric acid
within specification.
Longitudinal reversion test To ensure National uPVC pipes can be heat processed without any
damage to the pipe.
Flattening test To ensure National uPVC pipes and Fittings make or become flat
within specifications.
Tensile test To ensure National uPVC pipes are capable of being stretched within
Specifications.
Hydraulic characteristics test To ensure National uPVC pipes and fittings can be used within
Recommended pressure.
Inside Diameter of Socket To ensure National uPVC fittings perfectly fit with National uPVC
pipes.
Solvent Cement
Nominal Mean Outside Length TYPE 250 kPa TYPE 400 kPa TYPE 600 kPa TYPE 1000 kPa
Diameter Diameter ( Dm ) L ( 2.5 PN ( 4 PN ( 6 PN ( 10 PN
Nominal Pressure ) Nominal Pressure) Nominal Pressure ) Nominal Pressure )
Nominal Mean Outside Length TYPE 250 kPa TYPE 400 kPa TYPE 600 kPa TYPE 1000 kPa
Diamete Diameter ( Dm L ( 2.5 PN ( 4 PN ( 6 PN ( 10 PN
r ) Nominal Pressure ) Nominal Pressure) Nominal Pressure ) Nominal Pressure )
_________________________________________________________
Central Industries PLC 3.1
PIPE SYSTEM
________________________________________PRODUCT GUIDE
These pressure classes derived from the ISO specified pressure classes, PN 8, PN 10, PN 12.5, PN 16 PN 20 and PN 25
respectively.
THESE PRESSURE CLASSES SUPERSEDE THE PREVIOUSLY SPECIFIED VALUES, T 250, T 400, T 600 AND T
1000 AND THESE WILL NOT BE USED IN FUTURE.
Above values denote the safe working pressure or the Nominal Pressure of the water works system in kgf/cm2 at relevant
working temperatures. PNT is calculated to be used at 300 C.
Socketed joint for Solvent welding Bell end for Rubber Ring seal joint
_____________________________________________________________________________________________________
________________________________________PRODUCT GUIDE
uPVC Pressure Pipes and Fittings System
Injection Moulded Fittings Range
_________________________________________________________________________________________________________________________________
Socket
_________________________________________________________________________________________________________________________________
Solvent socket
Nominal A B C
Size (mm)
mm mm mm
20 17.5 3 38 **
25 20.0 3 43 **
32 23.5 3 50 **
40 28.0 3 59 **
50 33.0 3 69 **
63 39.5 3 82 **
75 43.5 3 90
90 51.0 5 107
110 61.0 9 131
For connecting pipes.
_________________________________________________________________________________________________________________________________
Reducing Socket
Nominal A B C D
Size (mm)
mm mm Mm mm
25x20 17.5 20.0 3.0 40.5 **
32x20 17.5 23.5 3.0 40.0 **
32x25 20.0 23.5 3.0 46.5 **
40x20 17.5 28.0 13.0 58.5 **
40x32 23.5 28.0 3.0 54.5 **
50x20 17.5 33.0 18.0 68.5 **
50x32 23.5 33.0 3.0 59.5 **
50x40 28.0 33.0 3.0 64.0 **
63x20 17.5 40.0 24.5 82.0 **
63x32 23.5 40.0 18.5 82.0 **
63x40 28.0 40.0 14.5 82.5 **
63x50 33.0 40.0 9.5 82.5 **
______________________________________________________________________________________
** All are National Injection moulded fittings conform to SLS 659 certification and suitable for
Type 1000 kPa (10 PN) pressure class .
*Threads if precast on National fittings comply with BS 21: pipe thread specifications.
________________________________________PRODUCT GUIDE
uPVC Pressure Pipes and Fittings System
Injection Moulded Fittings Range
_________________________________________________________________________________________________________________________________
Socket
_________________________________________________________________________________________________________________________________
Valve Socket
Nominal A B C D E
Size (mm)
mm mm mm mm (INCH)
20 17.5 22 14 39.5 1/2 **
25 20.0 24 15.5 44 3/4 **
32 23.5 27 17 50.5 1 **
40 28.0 30 19.5 58 1 1/4 **
50 33.0 31 19.5 64 1 1/2 **
63 39.5 37 24 76.5 2 **
75 43.5 42 31 85.5 2 1/2
90 51.0 45.5 34 96.5 3
110 61.0 51 39 112 4
Nominal A B C D E
Size (mm)
mm mm mm mm (INCH)
20 17.5 4 14 35.5 1/2 **
25 20.0 4 15.5 39.5 3/4 **
32 23.5 4 17.5 46 1 **
40 28.0 4 19.5 57.5 1 1/4 **
50 33.0 6 19.5 57.5 1 1/2 **
63 39.5 6 24 69.5 2 **
75 43.5 17.8 30.2 91.5 2 1/2
90 51.0 22.7 33.3 107 3
110 61.0 27.7 39.3 128 4
______________________________________________________________________________________
** All are National Injection moulded fittings conform to SLS 659 certification and suitable for
Type 1000 kPa (10 PN) pressure class .
*Threads if precast on National fittings comply with BS 21: pipe thread specifications.
________________________________________PRODUCT GUIDE
uPVC Pressure Pipes and Fittings System
Injection Moulded Fittings Range
_________________________________________________________________________________________________________________________________
Elbows
_________________________________________________________________________________________________________________________________
Elbow 90 0
Nominal A B C
Size (mm)
mm mm mm
20 17.5 11.0 28.5 **
25 20.0 13.5 33.5 **
32 23.5 17.5 41 **
40 28.0 21.5 49.5 **
50 33.0 27.0 60 **
63 39.0 33.5 73 **
90 51.0 48.0 99 **
110 61.0 60.0 121 **
_________________________________________________________________________________________________________________________________
Faucet Elbow
Nominal A B C D E
Size
mm mm mm mm mm (INCH)
**
20 17.50 11.00 25.00 28.50
________________________________________PRODUCT GUIDE
uPVC Pressure Pipes and Fittings System
Injection Moulded Fittings Range
_________________________________________________________________________________________________________________________________
Tees
_________________________________________________________________________________________________________________________________
Equal Tee
Nominal A B C
Size (mm)
mm mm mm
20 17.5 11.0 28.5 **
25 20.0 13.5 33.5 **
32 23.5 17.5 41 **
40 28.0 21.5 49.5 **
50 33.0 27.0 60 **
63 39.5 33.5 73 **
75 43.5 40.5 84 **
90 51.0 48.0 99 **
110 61.0 61.0 122 **
Reducing Tee
Nominal A B C D E
Size
mm mm mm mm mm mm
25x20 20 17.5 13.6 31.1 33.6 **
32x20 23 17.5 17.1 34.6 40.6 **
32x25 23 20.5 17.1 37.6 40.6 **
40x20 28 17.5 17.0 38.5 45.0 **
40x25 28 20.5 21.0 41.5 49.0 **
40x32 28 23.5 17.0 44.5 45.0 **
50x20 33 17.5 26.0 43.5 59.0 **
50x32 33 23.5 26.0 49.5 59.0 **
50x40 33 28.0 26.0 54.0 59.0 **
63x20 40 17.5 11.0 50.5 51.0 **
63x32 40 23.5 17.0 56.5 57.0 **
63x40 40 28.0 21.0 61.0 61.0 **
63x50 40 33.0 26.0 66.0 66.0 **
90x63 53 40 46 86 99 **
110x63 63 40 58 98 121 **
110x90 63 53 58 111 121 **
________________________________________PRODUCT GUIDE
Faucet Tee
Nominal A B C E
Size
mm mm mm Mm (inch)
20 17.5 11 14 1/2 **
End cap
Nominal A B
Size (mm)
mm mm
20 20 17.5 **
25 25 20.0 **
32 32 23.5 **
40 40 28.0 **
50 50 33.0 **
63 63 39.5 **
75 75 43.5
90 90 51.0 **
110 110 61.0 **
140 140 76.0
160 160 86.0
______________________________________________________________________________________
** All are National Injection moulded fittings conform to SLS 659 certification and suitable for
Type 1000 kPa (10 PN) pressure class .
*Threads if precast on National fittings comply with BS 21: pipe thread specifications.
Clamp saddle
Nominal
Size
mm
50 x 20
50 x 25
63 x 20
63 x 25
63 x 32
75 x 20
75 x25
75 x 32
90 x 20
90 x 25
90 x 32
110 x 20
110 x 25
For connecting a service pipe to the main pipe line, a uPVC
110 x 32
Clamp saddle could be used. The two halves of the clamp 160 x 20
saddle are bolted together on straight uPVC pipes ,as shown in 160 x 25
the diagram. 160 x 32
The rubber gasket around the outlet of the clamp saddle would 225 x 20
be in a compressed position against the external surfaces of the 225 x 25
pipe after bolting. 225 x 32
______________________________________________________________________________________
** All are National Injection moulded fittings conform to SLS 659 certification and suitable for
Type 1000 kPa (10 PN) pressure class .
*Threads if precast on National fittings comply with BS 21: pipe thread specifications.
________________________________________PRODUCT GUIDE
uPVC Pressure Pipes and Fittings System
Injection Moulded Fittings Range
______________________________________________________________________________________
PVC Ball Valves
_________________________________________________________________________________________________________________________________
BSP WORKING
SIZE THREAD PRESSURE
SIZE (Bar)
20 mm 10
1 32 mm 1 10
1 50 mm 1 10
______________________________________________________________________________________
Cable Trunking
Width Height
height 16x10 16 10
20x16 20 16
25x16 25 16
width
_________________________________________________________
Central Industries PLC 3.10
PIPE SYSTEM
________________________________________PRODUCT GUIDE
uPVC Pressure Pipes and Fittings System
Fabricated Fittings Range
_________________________________________________________________________________________________________________________________
Socket
_________________________________________________________________________________________________________________________________
Nominal A
Size
mm mm
20 20
25 24
32 28
40 34
50 41
63 50
75 59
90 69
110 83
140 104
160 118
______________________________________________________________________________________
Coupler
_________________________________________________________________________________________________________________________________
Repair Coupler Short (Ring seal type)
Nominal A B
Size mm mm
mm
63 245 180
75 265 190
90 270 195
110 295 215
160 350 250
225 405 295
280 465 315
________________________________________PRODUCT GUIDE
uPVC Pressure Pipes and Fittings System
Fabricated Fittings Range
_________________________________________________________________________________________________________________________________
Coupler
_________________________________________________________________________________________________________________________________
L2 L Nominal L L1 L2
Size mm mm mm
mm
63 120 10 196
d 90 135 10 229
110 145 330 346
160 170 340 363
225 205 540 462
L1 280 220 600 460
______________________________________________________________________________________
Bell form Reducer
_________________________________________________________________________________________________________________________________
63 x 50 145 65
75 x 63 145 160
90 x 75 170 165
110 x 90 185 170
160 x 110 245 175
225 x 160 310 210
280 x 225 375 250
______________________________________________________________________________________
*All National uPVC fittings described above are suitable for Type 1000 kPa (10 PN)
pressure class unless stated otherwise.
________________________________________PRODUCT GUIDE
________________________________________PRODUCT
20 11 1/4 55 20 35
22 1/2 55 20 35
45 55 20 35
90 55 20 35
25 11 1/4 60 24 50
22 1/2 60 24 50
45 60 24 50
90 60 24 50
32 11 1/4 75 28 65
22 1/2 75 28 65
45 75 28 65
90 75 28 65
40 11 1/4 95 34 75
22 1/2 95 34 75
45 95 34 75
** All these Bends are heat treated and formed 90 95 34 75
out of PVC pipes manufactured to SLS 147
Specification without any welded joint . 50 11 1/4 125 41 90
Socket dimension Conform to SLS 695 22 1/2 125 41 90
specification 45 125 41 90
90 125 41 90
Nominal Angle r A B
Size Deg. radius of mm mm
mm d curvature
mm
________________________________________PRODUCT GUIDE
uPVC Pressure Pipes and Fittings System
Nominal Angle r A B
Size Deg. radius of mm mm
mm d curvature
mm
20 11 1/4 55 20 35
22 1/2 55 20 35
45 55 20 35
90 55 20 35
B 25 11 1/4 60 24 50
22 1/2 60 24 50
45 60 24 50
90 60 24 50
32 11 1/4 75 28 65
22 1/2 75 28 65
45 75 28 65
90 75 28 65
40 11 1/4 95 34 75
** All these Bends are heat treated and formed 22 1/2 95 34 75
out of PVC pipes manufactured to SLS 147 45 95 34 75
Specification without any welded joint . 90 95 34 75
Socket dimension Conform to SLS 695
specification 50 11 1/4 125 41 90
22 1/2 125 41 90
45 125 41 90
90 125 41 90
Nominal Angle r A B
Size Deg. radius of mm mm
mm d curvature
mm
75 11 1/4 188 59 125
22 1/2 188 59 125
45 188 59 125
90 188 59 125
______________________________________________________________________________________
*All National uPVC fittings described above are available in Type 1000 kPa (10 PN) as well as
Type 600 kPa (6 PN) pressure class.
*Any intermediate angles can be supplied on request. Contact the Technical Division
________________________________________PRODUCT GUIDE
Flanged Socket
Nominal Size A B
Mm mm mm
63 210 110
75 230 115
90 255 120
110 280 130
160 380 150
225 420 170
280 450 190
_____________________________________________________________________________________
*All National uPVC fittings described above are suitable for Type 1000 kPa (10 PN)
pressure class unless stated otherwise.
*Threads if frecast on fittings comply with BS 21: pipe thread specifications..
________________________________________PRODUCT GUIDE
uPVC Pressure Pipes and Fittings System
Accessories
______________________________________________________________________________________
Saddle
_________________________________________________________________________________________________________________________________
Saddle
Nominal Size
mm
20
25
32
40
50
63
75
90
110
Tapered Core
E
Nominal Size A B C D E
32 29 28 42 29 3
40 36 35 50 30 3
50 46 44 65 40 5
A B C 63 57 55 76 40 5
75 67 65 88 45 5
90 81 79 100 45 5
110 104 102 123 45 5
140 132 129 159 55 5
160 151 148 179 65 5
225 211 208 243 65 5
D 280 262 259 297 70 5
______________________________________________________________________________________
_________________________________________PRODUCT GUIDE
uPVC Pressure Pipes and Fittings System
Accessories - Steel
_________________________________________________________________________________________________________________________________
Flange Connection
_________________________________________________________________________________________________________________________________
Flange Connection
Nominal No. of
Size A B C Bolting Bolts
mm mm mm mm
63 165 125 18 M16 4
75 185 145 18 M16 4
90 200 160 18 M16 8
110 220 180 18 M16 8
140 250 210 18 M16 8
160 285 240 22 M20 8
225 340 295 22 M20 8/12
280 395 350 22/26 M20/M24 12
_____________________________________________________
________________________________________PRODUCT GUIDE
Nominal SIZE
mm
63
75
90
110
160
225
280
______________________________________________________________________________________
National Solvent Cement
______________________________________________________________________________________
Solvent Cement.
15
25
50
100
250
500
______________________________________________________________________________________
Elbow 45 0 /Bend
Nominal Size A B
mm mm mm
63 143 103
_________________________________________________________________________________________________________________________________
Elbow 45 0 with Inspection Eye /Bend (I.O) comply to SLS 1325:2007 (ISO 3633: 2002)
_________________________________________________________________________________________________________________________________
Elbow 45 0 with Inspection Eye /Bend (I.O)
Nominal Size A B
mm mm mm
63 143 118
________________________________________________________________
63mm Sweep Tee comply to SLS 1325:2007 (ISO 3633: 2002)
_________________________________________________________________________________________________________________________________
Nominal Size A B
mm mm mm
63 164 125
______________________________________________________________________________________
*Above fittings are recommended for non pressure application
Nominal Size A B
mm mm mm
63 164 142
_________________________________________________________________________________________________________________________________
Elbow
_________________________________________________________________________________________________________________________________
Elbow 90 0
Nominal Size A B
mm mm mm
A
110 164 50.60
B
______________________________________________________________________________________
National Tees
______________________________________________________________________________________
Single Tee 90 0
Nominal Size A B
mm mm mm
A
110 218.6 167.92
______________________________________________________________________________________
*Above fittings are recommended for non pressure application
Central Industries PLC 3.24
PIPE SYSTEM
________________________________________PRODUCT GUIDE
uPVC Soil Waste and Drainage System
ISO 3633, BS5255,BS4514,BS4660
Injection Moulded Drainage Fittings Range
_________________________________________________________
450 Bend
_______________________________________________________________________________________________________
450 Bend
D S L L1
mm mm mm mm mm
_________________________________________________________
450 Bend M/F With I/O
_______________________________________________________________________________________________________
450 Bend M/F With I/O
D S L L1
mm mm mm mm
_________________________________________________________________________________________________________________________________
880 Sweep Bend M/F
_______________________________________________________________________________________________________
D S L L1 H
mm mm mm mm mm
______________________________________________________________________________________
*Above fittings are recommended for non pressure application
D S L L1 d
mm mm mm mm mm
_________________________________________________________________________________________________________________________________
880 Sweep Bend With Big I/O F/F or M/F
_______________________________________________________________________________________________________
D S L L1 d
mm mm mm mm mm
_________________________________________________________________________________________________________________________________
Sweep Junction M/F
_______________________________________________________________________________________________________
D L H H1
mm mm mm mm
50 70 128 70 880
______________________________________________________________________________________
*Above fittings are recommended for non pressure application
_______________________________________PRODUCT GUIDE
uPVC Soil Waste and Drainage System
ISO 3633, BS5255,BS4514,BS4660
Injection Moulded Drainage Fittings Range
_________________________________________________________________________________________________________________________________
Sweep Junction M/F With I/O
_______________________________________________________________________________________________________
Sweep Junction M/F With I/O
D L H H1
mm mm mm mm
50 70 128 70 880
_________________________________________________________________________________________________________________________________
Sweep Junction With Big Access F/F or M/F
_______________________________________________________________________________________________________
D d H H1 L
mm mm mm mm Mm
_________________________________________________________________________________________________________________________________
Reducing Sweep Junction M/F
_______________________________________________________________________________________________________
Nominal L D D1 H H1
Size mm mm mm mm mm
mm
______________________________________________________________________________________
*Above fittings are recommended for non pressure application
______________________________________PRODUCT GUIDE
uPVC Soil Waste and Drainage System
ISO 3633, BS5255,BS4514,BS4660
Injection Moulded Drainage Fittings Range
_______________________________________________________________________________________________________
Reducing Sweep Junction M/F With I/O
_______________________________________________________________________________________________________
Nominal L D D1 H H1
Size mm mm mm mm mm
mm
_________________________________________________________________________________________________________________________________
Y - Junction M/F With I/O or W/O I/O
_______________________________________________________________________________________________________
D L H H1
Mm mm mm mm
_________________________________________________________________________________________________________________________________
Reducing Y- Junction M/F or F/F With I/O
_______________________________________________________________________________________________________
Nominal Size D D1 L H H1
mm mm mm mm mm mm
______________________________________________________________________________________
*Above fittings are recommended for non pressure application
_______________________________________PRODUCT GUIDE
uPVC Soil Waste and Drainage System
ISO 3633, BS5255,BS4514,BS4660
Injection Moulded Drainage Fittings Range
_________________________________________________________________________________________________________________________________
Floor Trap Gully
_______________________________________________________________________________________________________
Floor Trap Gully
D d d1 H H1 H2
mm mm mm mm mm mm
D S H1 H C
mm mm mm mm mm
50 25 77 122 130
_________________________________________________________________________________________________________________________________
Adjusttable P-Trap With and Without I/O
_______________________________________________________________________________________________________
Adjusttable P-Trap With and Without I/O
D S C1 H1 H2
mm mm mm mm mm
50 25 133 77 111
_________________________________________________________________________________________________________________________________
100mm Round Base Grating-Spigot & anti insect device (optional)
_______________________________________________________________________________________________________
D S H1 H C
mm mm mm mm mm
______________________________________________________________________________________
*Above fittings are recommended for non pressure application
Central Industries PLC 3.29
PIPE SYSTEM
________________________________________PRODUCT GUIDE
uPVC Soil Waste and Drainage System
ISO 3633, BS5255,BS4514,BS4660
Injection Moulded Drainage Fittings Range
_________________________________________________________________________________________________________________________________
Top Tile
_______________________________________________________________________________________________________
Top Tile
Size A B C D E H
mm mm mm mm mm mm mm
_________________________________________________________________________________________________________________________________
Vent Cowl
_______________________________________________________________________________________________________
Vent Cowl
D S H
mm mm mm
D S H H1
mm mm mm mm
110 30 80 50
_______________________________________________________________________________________________________
D L H H1
mm mm mm mm
______________________________________________________________________________________
*Above fittings are recommended for non pressure application
D S H L
mm mm mm mm
110 52 92 230
________________________________________________________________________________________________________________________________
Vent Cowl
_______________________________________________________________________________________________________
Vent Cowl
D D1 S H C
mm mm mm mm mm
D D1 S L H
mm mm mm mm mm
Size D D1 H H1 C
mm mm mm mm mm mm
63 63 165 45 16 125
75 75 185 52 17 145
90 90 200 63 18 160
110 110 220 73 20 180
160 160 285 100 24 240
______________________________________________________________________________________
*Above fittings are recommended for non pressure application
P Trap
Nominal A B C D E
Size mm mm mm mm (Deg)
mm
______________________________________________________________________________________
S Trap
Nominal Size A B C D E
mm mm mm mm mm mm
______________________________________________________________________________________
*Above fittings are recommended for non pressure application
National Gutter
_______________________________________________________________________________________________________
A B C D Length
mm mm mm mm Mtrs.
______________________________________________________________________________________
National Down pipe
______________________________________________________________________________________
Mean out
Side diameter Thickens Length
mm mm Mtr.
______________________________________________________________________________________
National Down pipe elbow
______________________________________________________________________________________
Nominal
Size A B C D
mm mm mm mm mm
_____________________________________________________________________________________
*Gutter fittings( gutter bracket, miter joiner, gutter joiner, gutter end cap, centre running head,) are
available to complete the rang
National Conduits
_______________________________________________________________________________________________________
National Conduits
_________________________________________________________
Central Industries PLC 3.34
PIPE SYSTEM
________________________________________PRODUCT GUIDE
Electrical Insulation Fitting System
_________________________________________________________________________________________________________________________________
Socket
_________________________________________________________________________________________________________________________________
Socket
Nominal Size
mm
18
20
25
30
40
50
_________________________________________________________________________________________________________________________________
Saddles
_________________________________________________________________________________________________________________________________
Saddles
Nominal Size
mm
18
20
25
30
40
50
______________________________________________________________________________________
Bend
________________________________________________________________________________________________________________________________
Bend
Nominal Size
mm
18
20
25
30
40
50
______________________________________________________________________________________
Box
________________________________________________________________________________________________________________________________
Through Box 2 way
Nominal Size
mm
18
20
25
30
40
50
_________________________________________________________
Central Industries PLC 3.35
PIPE SYSTEM
________________________________________PRODUCT GUIDE
18
20
25
30
40
50
______________________________________________________________________________________
18
20
25
30
40
50
______________________________________________________________________________________
Tee Box
Nominal Size
mm
18
20
25
30
40
50
______________________________________________________________________________________
_________________________________________________________
Pipes and Accessories for duct-way of telephone underground
cables.
uPVC Pipes
______________________________________________________________________________________
Pipes
______________________________________________________________________________________
Nominal Outside
Size Diameter L l d1 t
mm mm
D mm mm mm mm
**Material uPVC
_________________________________________________________________________________________________________________________________
_______________________________________PRODUCT GUIDE
_______________________________________PRODUCT
Nominal Angle r A B C d1
Size Deg. radius mm mm mm mm
mm d mm
Size L1 L2 L d1 D T
mm mm mm mm mm mm mm
** Material uPVC
Flared Mouth
Flared Mouth
Size L1 L2 L d1 D T
mm mm mm mm mm mm mm
50 100 100 300 56.5 56 3
** Material uPVC
_________________________________________________________
Size A B C t
mm mm mm mm mm
4 inch thread (BSP)
110 98 60 175 6
** Material uPVC
**Spacers, Dust cap and other required fittings are available to complete the range
Nominal Wall
Size Thickness Colour Length
mm mm
mtr
_______________________________________PRODUCT GUIDE
Pipes and Accessories for duct-way of telephone underground
cables
HDPE Pipe Connecter
______________________________________________________________________________________
32 mm Socket
Size A B C t
mm mm mm mm mm
32 60 10 148 1.8
** Material uPVC
32 mm Rubber Spacer
Size d1 D t
mm mm mm mm
32 32 100 11
** Material Rubber
End Cap
32 mm End Cap
t Size A B t
mm mm mm mm
32 32 23.50 3
** Material uPVC
_________________________________________________________
Central Industries PLC 3.40
PIPE SYSTEM
______________________________________PRODUCT GUIDE
_____________________________________________________________________________________
Water Tanks
_____________________________________________________________________________________
Size d (mm) D (mm) H (mm)
Ltr.
**Material Polyethylene
______________________________________________________________________________________
Septic Tank
______________________________________________________________________________________
Material PE
unit
**Material Polyethylene
________________________________________PRODUCT GUIDE
______________________________________________________________________________________
Stainless Steel Tank
______________________________________________________________________________________
Ideal for storage of everything from water , Diary , Chemicals and food processing
*Most hygienic way of storing water
*No algae formation
*Wash out at the bottom for easy maintenance
*Keeps water cool
*Long lasting
* Elegant
*Light in weight
*Easy to handle
Garden Hose
Size Length(mtr.)
15 mtr /30 mtr
15 mtr /30 mtr
1 15 mtr /30 mtr
_______________________________________________________________________________________________________________________________
Basic Considerations
Internal Hydrostatic Pressure
Pressure Temperature Derating
Flow Characteristics
Thermal Expansion
P= 2t
(dm-t)
where,
P = test pressure in MPa
= Induced stress in MPa (=36 MPa)
t = minimum wall thickness in mm
dm = mean outside diameter in mm
Refer Product Guide for mean outside diameter and minimum thickness for pipes.
The minimum test pressure for testing at 29 0C 1 , deduced from the above formula for all pipe sizes are as
follows:-
According to the SLS 147 specification the minimum Factor of Safety (F.O.S) should be 4.3 against bursting at 29
0
C. However pressure test have shown that National uPVC pipes have a higher F.O.S varying from 4.5 to 6.0.
The maximum operating temperature for a NATIONAL pipeline under continuous pressure is 45 0C
In circumstances where the anticipated working pressure exceeds the maximum rating of the pipe obtained from the
graph, it may still be possible to use the pipe but with a reduced life expectancy.
7
6
5
4
3
2
1
0
0 10 20 30 40 50 60
Temperature C
Flow Characteristics
The flow characteristic of a pipe is dependent on the internal pipe diameter and the frictional resistance of the pipe
wall.NATIONAL uPVC pipes have extremely smooth internal surfaces and excellent chemical resistance(see
annexure - 02). Thus the internal surfaces inhibit deposition as well as scouring. The hydraulic characteristics are
found to remain constant during the life of the system. Over sizing of pipe to cater for future performance losses is
not required.
Pipe material C
Friction Chart based on Hazen - Williams Formula can be used for rapid calculation of the head loss due to friction
in uPVC Pipes.
h = k.V 2
2.g
Where,
h = head loss
V = velocity of flow
g = gravitational acceleration
c Abrupt Contraction.
(Velocity after contraction) Radius of 6 x diameter Bend
D2/D1 = 0 0.50 Deflection angle
D2/D1 = 0.4 0.40 90 0 0.15
D2/D1 = 0.6 0.30 45 0 0.11
D2/D1 = 0.8 0.10 22 1/2 0 0.08
D2/D1 = 1.0 0.00
c. Bends
Radius of 1 x diameter bend Radius of 8 x diameter Bend
Deflection angle 90 0 0.50 Deflection angle 90 0 0.15
45 0 0.37 45 0 0.11
22 1/2 0 0.25 22 1/2 0 0.08
Alternatively the head loss due to fittings could be assessed by representing the fittings with an equivalent pipe
length, which is defined as a length of pipe of the same diameter that would result in a head loss equal to that of the
respective fitting.
L = L T
Where,
L = Change in length
0
= Coefficient of linear expansion C -1
T = Change in temperature 0 C
The coefficient of linear expansion of uPVC is approximately 60x10-6 meter per meter per degree Centigrade.
If a straight pipe section is restrained from expansion by anchoring, the longitudinal thermal stress t can be
expressed as,
t = L
E = ET
L
Where
It could be observed that longitudinal thermal stress is independent of length or the diameter of the pipe.
Expansion joints are provided where necessary, to reduce temperature stresses.
The use of pipes with ring seal type joints (RS) will entirely prevent the development of thermal stresses, as
expansion is accommodated at the rubber ring joint. Other methods of overcoming damaging effect of thermal
expansion are discussed in INSTALLATION GUIDE.
Pipe systems are designed for carrying capacity (flow) and pressure conditions. Thus assessment of the water
demands and the requirement of pressure are basic considerations in design of water supply systems.
Water Demands
The water demand in a system is assessed taking into account domestic, industrial, commercial and institutional
usage. Domestic water demands are estimated based on the served population and the corresponding per capita
consumption. Different values of per capita consumption are adopted for population served through common outlets,
and for urban and rural areas.
Other special demands such as industrial, commercial, institutional etc. are estimated based on consumption norms.
Guidelines are given below.
Design period adopted for water systems could vary from 20 to 30 years. The water demands are projected for the
design period using appropriate growth and demand factors.
The daily peak factor is found to vary between 1.10 to 1.15. This factor should be considered in designing of
pumped and gravity water transmission pipe lines. Further, over a day there is an hourly variation of water
consumption. The hourly peak factor is defined as,
The hourly peak factor varies with the size of population served. The variation could be as high as 3.0 for small
communities down to 1.5 for very large communities. The hourly peak factor should be considered in the design of
water distribution systems.
Fire Demands
In addition to normal consumption, a water distribution system should be designed to cater for fire fighting water
requirements . The design draw off could vary from 20 to 80 liters/sec depending on the level of risk involved.
Hydraulic Analysis
In order to carry out hydraulic analysis of a water supply system the pipe network is represented in the form of a
nodal diagram. The water demands corresponding to the respective pipes are converted to nodal draw offs.
Pipe systems could be either simple Branch systems or Looped systems.
10 11
1 2 3 4 5 6
7 8 9
Hydraulic Analysis
1 2 3 4 5
6 7 8 9 10
11 12 13 14 15
Hydraulic analysis is carried out to satisfy the residual pressure requirements of the pipe system. Residual pressure is
defined as the pressure head available at any point of the distribution system. In local practices, distribution systems
are designed for a minimum residual head of 10 meters. This would facilitate supply of water to two story buildings.
Hydraulic analysis of Branch system is straight forward and manual methods may be adopted. However, iterative
methods should be applied for analysis of looped systems. Standard computer software is available for hydraulic
analysis of looped pipe networks.
Sizing of the pipe network is carried out based on the hydraulic analysis so that required residual pressure is
maintained. The class of pipe is determined considering the internal pressure subjected to the pipe.
Water Hammer
If the water flow in the pipe is abruptly shut out or decelerated, the kinetic energy of the water column is converted to
pressure energy producing a series of pressure waves that travels back and forth in the pipe line until they are
dampened by friction. The water in the pipe is compressed, thus stretching the pipe walls. This phenomenon is called
Water Hammer." It could occur due to sudden closure of a valve or due to stoppage of pumps in a forced main.
The propagation speed of the pressure wave is expressed by the formula,
C 2 = K g /n
1+K d
Et
Where.
C - Velocity of pressure wave (m/sec).
K - Bulk modules of liquid (Kg/m 2) (K=2.05 x 10 8 for Water at 28 C)
E - Modules of elasticity of pipe material (Kg/m 2) (E=3.19 x 10 8 for uPVC)
g - Gravitational acceleration (9.81 m/sec 2)
d - inside diameter of pipe (m)
t - Wall thickness of pipe
n - Specific gravity
If the length of the pipe is L, the wave travels back and forth in time t given by.
t = 2L
C
If the time of closure t c < t,
The Water Hammer pressure is approximated as.
P = nCV
g
Where, V - initial velocity or flow
If t < t c , the full pressure will not be realized. The water hammer pressure is approximated as,
P1 = t c p = 2 L n V
t tg
The pipe should be capable of withstanding the total pressure, i.e., static pressure plus water hammer pressure. When
pressure due to water hammer has been considered, the allowable working pressure for the pipe is taken as, 1.1 x
working pressure rating of pipe.
In gravity water distribution systems, the effect of water hammer is not very significant. However, in pumped
systems, Water Hammer effects could be significant and should be considered in the design. Water hammer due to
power failure that is instantaneous could be most critical. Limiting the flow velocities would minimize water hammer
effects due to shutting off pumps. In situations where the pipeline cannot withstand surge pressures, specially
designed surge vessels are installed. (Technical Division).
Example:-
Data- Static pressure P = 4 kg/cm 2
Fluid speed V = 1 m/sec
Time of closure of the valve T = 3 sec
From V = 1m/sec draw a horizontal line until it meets the line L = 100m. Drop a horizontal line from this point until it
meets
the line T = 3 sec.
A vertical line from this point will obtain the extra pressure of 8.0 kg /cm 2
Total pressure which acts in the tube is P = 4+8 =12 kg/cm
Impulsive momentum principal could be applied to determine thrust forces acting on pipelines. Applying impulsive
momentum principal in x and y directions, the forces F x, F y is deduced.
Fx = - Q (V 2 Cos
P1 A1 - P2A2Cos - V1)
Fy = + QV2 Sin
P2A2Sin
Where,
= Density of the fluid
Q = Rate of flow in pipe
V = Velocity of flow
Similarly the axial force acting on the body of water in a contracting section of a pipeline, a reducer for example can
be estimated from the following formula.
F = P1 A1 - P2A2 - Q (V 2 - V1)
In each of the aforementioned two cases , forces equivalent and opposite to that of F x , Fy
and F are transferred on to the pipeline. Suitable thrust blocks have to be provided to resist these forces.
Resultant Force
The magnitude of the resultant force R can be calculated from
F = /2)
A x P x 2.Sin (
Where,
A = Cross section of external pipe diameter
p = Maximum proof hydraulic test pressure
= Angle of deviation of bend
For design purpose the internal hydraulic pressure is taken as the test pressure which is 1.5 x pressure rating of pipe,
e.g.:- 15 bar for type 1000 (10 bar) pressure class.
Thrust forces in KN calculated on the basis of 15 bar test pressure class, for common types of fittings are tabulated
below.
A factor of 0.67 may be used to obtain the thrust forces applicable for type 600 pipes.
The sectional area of a thrust block required to resist the thrust force is dependent on the bearing capacity of the soil in
the same direction.
Peat 0
Soft Clay 65
Sand 135
Sand and gravel 200
Sand and gravel cemented with clay 270
Two types of air valves namely, single orifice type which is a one way air release valve and the double orifice type
which could release as well as intake air are available. Single orifice air valves are used on small distribution mains.
Double orifice air valves are used on larger distribution mains and pumping mains.
GROUND PROFILE
AIR VALVEL
AIR VALVE
ISOLATING VALVE
UPVC PIPE
REDUCING TEE
GROUND PROFILE
UPVC PIPE
PROFILE
SCOUR VALVE
LOCATION
G.I. SURFACE
BOX
UPVC
PROTECTION
TUBE
TO DRAIN
Sizing of Pipes
The sizing of portable water supply pipe systems from the source of supply to the fixture, supply branches, risers,
fixtures, and other outlets shall be based on the total demand.
The quantity of water required to be supplied to every plumbing fixture shall be represented by fixture units, as given
in below.
Bar sink 1 2
Bath tub 2 4
Bidet 2 4
Drinking fountain - 1
Hose bib 3 5
Kitchen sink 2 4
Laundry tub (clothes washer) 2 4
Lawn sprinklers (each head) 1 1
showers 2 4
Urinal (pedestal type) - 10
Urinal (wall type) - 5
Urinal (flush type) - 3
Wash basin 1 2
Water closet (flush tank) 3 5
Water closet (flushometer valve) 6 10
The design demands (flows) corresponding to the respective fixture units could be assessed using the demand load
curve on the next page.
The following must be considered in determining the size of any pipe section.
30
25
Demand (l/s)
20
systems using flush tanks
15
10
0
0 500 1000 1500 2000 2500 3000
Fixture units
0
0 50 100 150 200 250 300
Fixture units
Length Horizontal
Unlimited
The unit equivalent of fixtures and devices not shown in above shall be estimated on the following basis.
Discharge Capacity
Fixture Units
up to 6 up to 45 1
7 to 13 50 to 100 2
14 to 25 105 to 190 4
26 to 40 200 to 300 6
The minimum sizes of vertical and/or horizontal drainage piping shall be determined from the total of all fixture units
connected there to and additional, in the case of vertical drainage pipes , in accordance with their length.
The maximum number of fixture units allowed on any vertical or horizontal drainage pipe , building drain or building
sewer of a given size; the maximum length of any vertical drainage pipe of a given size are as follows.
Bath tubs 40 2
Bidets 40 2
Drinking Fountains 32 1
Floor Drains 50 2
Interceptors - grease , oil , solids 50 3
Interceptors - sand , auto wash 75 6
Laundry Tubs (clothes washers) 50 2
Showers 50 2
Sinks - bar , commercial 40 2
Sinks - industrial , schools 40 3
Sinks - flushing rim , clinic 75 6
Urinals - pedestal 75 6
Urinals - wall 50 2
Wash Basin - single 32 1
Wash Basin - in sets 40 2
Water Closets - tank type 75 4
Water Closets - flush valve 75 6
Cleanouts
Each horizontal drainage pipe shall be provided with a clean out as its upper terminal and each run of piping, which is
more than 30m in total developed length shall be provided with a clean out. An additional cleanout shall be provided
in a horizontal line for each aggregate change of direction exceeding 135 degrees.
Each cleanout, unless installed under an approved cover plate shall be above grade, readily accessible and so located
as to serve the purpose for which it is intended. Cleanouts in piping 50 mm or less and greater than 50 mm shall be so
installed that there is a clearance or not less than 300 mm and 450 mm respectively.
Cleanout fittings in size shall not be less than those given below.
40 40
50 40
63 63
75 63
>110 90
FRONT ELEVATION
Stack height should be reduced if pipes are nested (i. e. pipes stored inside those of larger diameters)
Reduction in stack heights should be proportional to the total weight of the nested pipes compared to
the weight of pipes normally contained in such storage.
** The pipes should be stored in the shade and should not be exposed to direct sunlight.
____________________________________________________INSTALLATION GUIDE
Jointing
Cold Solvent Cement Welding Joint
Flanged Jointing
Tapered Core and Flanged
Flanged Adapter
Flanged Socket
Flanged Spigot
Threaded Joint
Couplings
Steeped Coupling
V.J.Coupling
Clamp Saddle
Installation
Installation below Ground
Trenches
Pipe bedding
Back filling
Laying under special conditions
Allowable radius of curvature for cold bend uPVC pipe
Pressure Testing
Jointing Method
Cold Solvent Cement Welding
Correctly made joints using cold solvent cement * Absorbent Paper
welding are stronger than either pipe or fitting. They * Fine Toothed Saw
can be made more quickly and effectively. * File or rasp
* Pencil
National uPVC Solvent cement makes the perfect
joint swelling the pvc pipe and fitting. The efficiency
of the joints is greatly reduced if the jointing surfaces
are not cleaned and prepared according to the
following procedures. Precautions
Items required for Solvent Cementing, 1. Never keep cement bottle open during breaks in
* National Solvent cement application of cement.
* Cleaner Bottle must always be tightly sealed (using insert)
* Clean paint brush
2. Avoid applying cement on a wet surface (or in the
Pipe Size Brush Type rain)
3. As cement is flammable liquid ensure work area
up to 32 mm 1/2 round brush is clear of falling sparks or other sources of
40 mm - 63 mm 1 flat brush ignition etc.
75 mm - 160 mm 2 flat brush
225 mm - 280 mm 2 1/2 flat brush
________________________________INSTALLATION GUIDE
20 16
25 19
32 22
40 26
50 31
63 38
75 44
90 51
110 61
140 76
160 86
225 119
280 146
____________________________________________________INSTALLATION GUIDE
Approximation Estimation of Solvent Cement
Requirement
20 800
25 600
32 500
40 300
50 250
63 175
75 125
90 75
110 50
160 20
225 8
280 5
63 100
75 60
90 60
110 50
160 30
225 20
280 20
Insertion Length
Nominal diameter Insertion depth l mm
mm
63 90
75 100
90 105
110 110
160 130
225 155
280 180
_____________________________________________________INSTALLATION GUIDE
Installation of uPVC Repair Coupler
Usage;
(a) Repairing local damage
(b) Replacing damaged portion
(c) Installation new fitting oh the existing pipeline
______________________________________________________INSTALLATION GUIDE
Flanged Jointing.
If a PVC pipe is required to be connected to a flanged item, one of the following methods could be used.
______________________________________________________INSTALLATION GUIDE
Couplings
Stepped Couplings
Stepped couplings are also used to connect pipes of
equivalent size and different materials and
consequently having marginally different outside
diameters. Sectional diagrams of such a coupling is as
follows:
V. J .Couplings
This is very versatile and a common method for
coupling of two similar pipes. Water tightness is
achieved due to two rubber rings seated on either side
of the joint pressed against the pipe.
______________________________________________________INSTALLATION GUIDE
ClampSaddle
For connecting a service pipe to the main pipe line, a uPV
Clamp Saddle could be used. The two halves of the clamp
saddle are bolted together on straight uPVC pipe, as
shown in the diagram. The rubber gasket around the
outlet of the clamp saddle would be in a compressed
position against the external surface of the pipe after
bolting.
VALVE SOCKET
FERRULE
MAIN PIPE
CLAMP SADDLE
_____________________________________________________INSTALLATION GUIDE
Public Roads - Heavy 900 - 1100 mm The trench bottom should be carefully examined for
Traffic the presence of hard objects such as flints, rocky
Private Roads projections or large tree roots which could cause
>63mm Pipe Size 750 mm damage to the pipe.
< 63mm Pipe Size 600 mm In uniform fine grained soils found to be free of
such objects, the pipes may be laid directly on the
Private Land 300 mm trench bottom. The trench bottom should be leveled
to provide a uniform support for the pipes over their
length.
Pipe Bedding
Where soil conditions are not suitable for laying of pipes directly on the trench bottom, the trench should be deepened
and a suitable bedding provided to receive the pipe.
_____________________________________________________INSTALLATION GUIDE
(b) Rocky, stony, hard cabook sub soil.
Backfilling
Backfilling material up to 300 mm from the top of the
pipe should be granular, free from stones and other
foreign material. If the excavated material is granular,
it could be used as backfill material. A selected backfill
material or sand should be used otherwise.
______________________________________________________INSTALLATION GUIDE
Pipe Laying Under Special Conditions
Laying on Swamp or Marshy soil:
On extremely poor soft marshy soil the pipe line
should be laid on a piled foundation.
CONCRETE
Pipe laying on steep ground. STOPPERS
In case of pipe laying on steep ground when the pipe
bedding and backfill material could get washed away,
concrete or clay stoppers should be provided.
BITUMEN
PACKING
PVC
PIPE
______________________________________________________INSTALLATION GUIDE
Pressure Testing.
After a section of the pipeline has been laid and Following are some important points :-
joined, it shall be tested for water tightness before
complete backfilling. Sections of about 300 meters 1. Incomplete air removal can lead to accidents as
length are tested at a time as work proceeds. The well
trench may be partially backfilled except at joints as inconsistent and misleading test results.
which shall be left open. One open end of the pipeline
is closed by a suitable removable cap. If the pipe end 2. Pressure increases shall be gradual and it could be
is flanged, a blank flange could be used for this regulated using a bypass with a valve.
purpose. However, if the pipe has a plain end, it could Water hammer effects shall be reduced or
be closed by using a ring seal type flanged socket and eliminated by slow valve operation.
a blank flange
3. Solvent Cemented joints shall be left for at least 24
A similar arrangement could be used to close the hours before pressure testing.
other end of the pipeline, but with a 25mm inlet on
the blank flange.
__________________________________INSTALLATION GUIDE
Good and Bad pipe Supports
-l1
FS - Fixed Support
SS - Sleeve Support FS
L - Length between Fixed support to point
subject to contraction effect.
X - Safe spring Length X
SS
__________________________________INSTALLATION GUIDE
__________________________________INSTALLATION GUIDE
Suitable Supporting Arrangement for Avoiding Thermal Expansion Problem.
FS = FIXED SUPPORT
SS = SIMPLY SUPPORT
__________________________________INSTALLATION GUIDE
General recommendation for spacing of supports.
Subsequent Installation.
Fittings can also be used as jointing to existing pipes.
The ends of the pipe have to be chamfered before the branch fitting. The two repair couplers will help to close the
gap in the pipe line which has to be fitted with a piece of pipe.
When only one repair coupler is employed , the section to be cut out of the pipe line will have to correspond to the
laying length of the branch (i.e. T or Y ) plus one fifth of the pipes outside diameter.
Both pipe ends have to be burred and chamfered. The repair coupler will be slipped on to one end of two the pipes,
whilst the other end has to be slightly bent for the branch (i.e. T or Y) to be inserted. The repair coupler can
finally be slid over the juncture, the connection is made and pipe line jointed.
**Before the system is put into use, it should be tested for leakage by air test, hydraulic test or smoke test.
FLUSHING CISTERN
OVER FLOW
FLUSH PIPE
(3/4) 25 mm
PILLAR COCK
OVER
FLOW
HOLE
WASTE
OUTLET
TO P TRAP
NATIONAL
NATIONAL PIPE
PIPE CONNECTIONS
CONNECTIONS TO TO BATH
BATH
(AUTOMATIC) FLUSHING
DIVISION PIECES
URINAL BOWLS
WASTE OUTLET
APPROX 610
mm FROM (1 ) 40mm DIA
FLOOR LEVEL NATIONAL P TRAP
SIDE ELEVATION
NATIONAL PIPE CONNECTIONS TO BOWL URINALS
__________________________________INSTALLATION GUIDE
ANNEXURE - 1
ANNEXURE - 2
CHEMICAL RESISTANCE OF
UNPLASTICIZED P.V.C
Notations:-
S - Satisfied
U - Unsatisfied
D - Some attached or absorption, the matter
Considered for use, where limited life is
acceptable.
* - Predicted Result
liquid U U* Benzene U U
35%
Ammonia solution (m/v)soln S S Benzoic acid D U
(ammonium hydroxide) (0.88 g/ml) Benzoyl chloride U* U*
Ammonium bicarbonate, see Benzyl acetate U U*
ammonium hydrogen Benzyl alcohol
carbonate phenylcarbinol) U* U*
Ammonium carbonate S S Bismuth carbonate S S
Ammonium chloride S S Borax, see disodium
Ammonium ferrous citrate S* S* tetraborate
Ammonium fluoride S S Boric acid S S
Ammonium hydrogen Boron trifluoride S
carbonate S* S* Brine S S
Ammonium hydroxide, Bromine trace S U
see ammonia solution 100% dry gas U* U
Ammonium metaphospate S S liquid U U
Ammonium nitrate S S Bromomethanc
Ammonium orthophosphates S* S* (methyl bromide) U* U*
Ammonium oxalate S* S* Butadiene S S
Ammonium persulphate S S Butane S S
Ammonium sulphate S S Butanediols U U
Unplasticized Unplasticized
Unplasticized Unplasticized
Unplasticized Unplasticized
Tallows S* S* Yeast S S
Tannic acid S S
ANNEXURE - 3
UNITS OF PRESSURE
UNITS OF PRESSURE
A multitude of different units of pressure and stress appear in use, even in metric countries. In most cases sufficient
accuracy of conversion is achieved by equating.
= 1.0197 KP/Cm 2
1 Bar = 1 4.5038 Lbf/in 2
= 1.0197 Kgf/Cm 2
ANNEXURE - 4
SLS 147: 1993 Rigid uPVC pipes for potable cold water supplies (Second Revision)
SLS 659 : Part 1 : 1993 Rigid uPVC Pipes joints and fittings for Potable Cold Water Supplies.
Part 1 - Socket Fittings for Solvent Welding (First Revision)
SLS 935 : 1991 Solvent Cement for Polyvinyl Chloride (uPVC) Pipes and Fittings.
SLS 993 : Part 1 : 1993 Conduits for electrical installation Part1 : General Requirements
IEC 614 - 1 : 1978
IEC 614 - 2 - 2 : 1980 Particular Specifications for rigid plain Conduits of Insulating materials.
SLS 989 : 1993 Outside Diameter of Conduits for Electrical Insulations and threads for Conduits
and Fittings.
BS 2494 : 1990 Specifications for Elastomeric Seals for Joints in Pipe work and Pipe Series.
BS EN 681-1 Specifications for Elastomeric Seals for Joints in Pipe work and Pipe Series.
BS 4504 Specifications for Flanges and Bolting for pipes, Valves and Fittings - metric
series.
BS 21: Specifications for Pipe Threads for tubes and Fittings where Pressure - tight
joints are made on the threads.
_______________________________RELEVANT STANDARDS
ISO 4422 : 1990 Pipes and fittings made of uPVC for Water Supply
ISO: 161 - :1978 Thermoplastic Pipes for the Transport of Fluids - Nominal Outside Diameters
and Nominal Pressure - Part 1: Metric Series.
ISO 727 : 1985 Fittings of uPVC ,cPVC ,or ABS , With Plain Sockets for Pipes Under Pressure -
Dimensions of Sockets - Metric Series.
ISO TR 4191 uPVC Pipes for Water Supply - Recommended Procedure for Laying.
Pt. 2. uPVC Pipe Work for the Conveyance of Liquid under Pressure.
ANNEXURE - 5
USEFUL REFERENCES.
_________________________________USEFUL REFERENCES
REFERENCES
1. Ray K .Linsley and Joseph - B. Franzini Mcgraw Hill Book , Water Resources Engineering in
1978.
2. A.C. Twort and F.W. Crowley - Edward Arnold Publishers, Water Supply in 1978
3. A.K. Chatterjee - Khanna Publishers, Water Supply and Sanitory Engineering in 1978.