Beruflich Dokumente
Kultur Dokumente
Job Job no
JIPCT
JIPCT
Part of Calc sheet no
END CONNECTION
structure
Dwg ref Calculations by Checked by Date
HND 15-Dec-17
HILTI BOLT CALCULATION
1. Data
fcu 40 Mpa Use HSA-R
h= 300 mm Size M16
hef 80 mm --> Ccr,N = 120 mm
c 500 mm Scr,N = 240 mm
s 90 mm
2. Tensile resistance:
Tensile resistance is the lowest value of:
- Steel Resistance (NRd,s) = 62.60 kN
3. Shear resistance:
Shear resistance is the lowest value of:
- Steel Resistance VRd,s = 45.20 kN
2. Tensile resistance:
Tensile resistance is the lowest value of:
- Steel Resistance (NRd,s) = 57.21 kN
3. Shear resistance:
Shear resistance is the lowest value of:
- Steel Resistance VRd,s = 40.80 kN