Sie sind auf Seite 1von 68

TRUSTED

SERVICE.
POWERING
SOLUTIONS.
Measurement & Test Equipment Rental Resource Guide
BEING THE BEST IS NOT A SLOGAN, OR A We pride ourselves on our core values
SHORT-TERM, TACTICAL GOAL. It is a strategy we are:
that defines everything we do. We are not a
publicly traded company whose goals are driven by Proactive: We dont wait and hope things work
Wall Street and quarterly estimates. Our goals out; we take advantage of every opportunity to
come from you, our customers. ensure success.

As you look through this brochure, keep in mind Responsive: When you call us, whether it is for a
we build upon the customer experience with our quote, technical support, or just help you will have
fantastic selection of the latest and greatest the information you requested immediately.
electrical and measurement test equipment, with
the personal touch of competent service that will
meet your needs and exceed your expectations. Principled: We do the right thing. We do not use
We dont think that you should have to pay more internal procedures as a reason not to do
for the treatment you deserve. something; we use them as a framework to ensure
that we are doing the right thing.

When you call or email us you will interact with:


Customer Focused: Your success is our success,
People who are positive so everything we do is geared toward making you
more competitive and successful in the
People who genuinely care
marketplace.
P
 eople who know what they
are talking about
Reliable: Everyone that deals with us can count
P
 eople who say what they will do on us to do what we say vendors, customers,
and do the right thing employees, friends, and family.

Because of these core values and the people that live them every day we believe that we offer:

Trusted Service. Powering Solutions.


TABLE of contents

Transformer / Motor /
Generator Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Circuit Breaker Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Relay Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Hipots and Cable Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Power Analysis and Data Acquisition . . . . . . . . . . . . . . . . 36
Insulation / Ground Testing . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Battery Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Instrumentation and Controls . . . . . . . . . . . . . . . . . . . . . . . 49
Inspection Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Gas detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
additional test Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
TRANSFORMER / MOTOR /
GENERATOR TESTING

Power Factor Testing . . . . . . . . . . . . . . . . . . . . . . . . . 5 Oil testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12


Doble M4000 / M4100 High Voltage DTS-60D
Megger CB-100 Hipotronics OC60D
Megger Delta 3000 Megger OTS-60PB
Megger OTS-60SX
Winding Resistance Testing . . . . . . . . . . . . . . . . . . . 8
Vanguard WRM-10 Phase Sequence /
Raytech WR-50-1 / WR-50-2 Motor Rotation Indicators . . . . . . . . . . . . . . . . . . 13

Raytech WR-50-12 Amprobe PRM-1


Tri-State TSW-45
Transformer Turn Ratiometers . . . . . . . . . . . . . . 9
AEMC DTR8500 CT / PT Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

Raytech TR-SPY Mark II Adwel CTX-2000


Vanguard ATRT-01 / ATRT-01B Megger CTER-91
Vanguard ATRT-03 Megger MCT1600
Vanguard EZCT
Sweep Frequency Response Analyzers . . . . . . 11 Vanguard EZCT-10
Doble M5200 / M5400 Vanguard EZCT-2000
Vanguard EZCT-2000A
Vanguard EZCT-2000B

4
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\ Power Factor Testing

Megger CB-100 Doble M4000 / M4100

 ow-voltage capacitance and insulation power


L
factor test set
 elf-contained instrument that accurately measures
S
insulation characteristics
 vercomes 60 Hz interference by shifting the
O
frequency of the bridge output to 100 Hz
 apacitance and dissipation factor read out directly
C  iagnostic test system / 12kV power factor
D  utput current to 300mA at 10kV to duplicate
O
from the instrument - no calculation required test set in-service conditions
 est complex insulating systems without
T Industry standard for testing high-voltage  ptional Type C Resonator increases
O
changing leads power apparatus output capacity
 irect reading of capacitance and dissipation factor
D  ine Frequency Modulation technology
L  ptional OTC (Oil Test Cell)
O
 8 volt test voltage makes the instrument extremely
2 eliminates substation signal interference  ptional M4100 TTR Capacitor
O
safe to operate  enerates its own precise sine wave test signal
G  ptional M4110 Leakage Reactance Module
O
 erforms tests to either GST or UST configurations
P to produce the most reliable results  ptional M4140 Capacitor Bank Tester
O
 -CHEKTM calibrator provides capacitance and
CB  erify and recalibrate in the field, so its
V
dissipation factor constant for the five test modes always accurate
 easure Power Factor/Tan Delta, Capacitance,
M
and Excitation Current

Provided by Protec with pre-configured


laptop at no additional cost

protecequip.com 972.352.5550 | toll free 866.352.5550 5


Power Factor Testing \\\\\\\\\\\\\\\\\\\\\\\\\\\\\\

Meg g e r T e s t I n s t r u m e n t s Insulation Testers

Our 1-kV models, the MIT400 Series, are designed to meet the
H i g h P e r f o r m a n ce. Enhanced Design. varying needs and budgets of all types of end users. This family
of instruments provide end users with more testing capability,
while maintaining an easy-to-use interface.
The MIT400 Series offer test voltages from 10 to 1000 V, and
includes an exceptional insulation resistance measurement
range that extends from 20 Gigohms to 200 Gigohms.

Our MIT510/2 & MIT520/2 (5 kVs), and MIT1020/2 (10 kV) are
the most popular insulation testers above 1 kV in the world.
These instruments were designed based on Meggers extensive
knowledge of insulation testing (100+ years of experience) and
significant feedback from actual end users.
They include Meggers patented digital/analog display with
real-time pointer movement, industry best measurement
sensitivity and an industry best CATIV 600V safety rating.

Ground Testers

Megger meets the need for two-, three, or four-pole testing


with our DET4T2 Series of ground testers. Weve increased the
resistance range by a few thousand ohms! We also added a
user selectable variable test frequency that provides additional
flexibility for noise suppression. The top-end models, DET4TC2
and DET4TCR2, provide stakeless testing and ART (Attached
Rod Technique) capabilities.
The leader in insulation testing, ground testing,
A wide range of kit options are available which allow you to
and much more. select the combination to suit your specific needs.

Our Dedication to Megger Electrical Test Equipment.


Protec is an Authorized Stocking Distributor of Megger and proudly
offers all of the Megger products you need to fully conduct your
electrical testing and analysis at the right prices. We offer a wide
variety of Megger products ranging from insulation testers, ground
testers, clampmeters, multimeters, time domain reflectometers, and

www.megger.com/us
much more.

Log on to www.protecequip.com for information on Megger test


and measurement equipment.
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\ Power Factor Testing

Megger CB-100 Megger Delta 3000

 ow-voltage capacitance and insulation power


L 1 0kV Automated insulation power factor  p to 100,000 data sets can be downloaded
U
factor test set test set directly to a PC or USB flash device
 elf-contained instrument that accurately measures
S  ully automated, AC Insulation diagnostic test
F  rint without an external computer using built in
P
insulation characteristics set for high voltage apparatus USB port and included USB printer
 vercomes 60 Hz interference by shifting the
O  easure voltage, current, power (loss), power
M  erform all standard UST and GST tests
P
frequency of the bridge output to 100 Hz factor, capacitance, and dissipation factor  odular design for easy transport
M
 apacitance and dissipation factor read out directly
C  onvert current and loss readings to their 2.5kV
C  arge 8.4 full VGA bright color display
L
from the instrument - no calculation required or 10kV equivalents  ptional resonating inductor extends
O
 est complex insulating systems without
T  easure excitation current of
M capacitance measurement
changing leads transformer windings  ptional HV TTR capacitor (10 nF) in addition to
O
 irect reading of capacitance and dissipation factor
D  ully automatic operation, stand-alone or
F two HV reference capacitors
remote-control, with user interface  ptional Calibration Standard verifies proper
O
 8 volt test voltage makes the instrument extremely
2
safe to operate Integrated PowerDB allows for data analysis and operation and accuracy of the test results
trending in the field, without external computer
 erforms tests to either GST or UST configurations
P
Interference suppression circuitry ensures
 -CHEKTM calibrator provides capacitance and
CB
accurate testing in substation environments
dissipation factor constant for the five test modes
up to 765kV

protecequip.com 972.352.5550 | toll free 866.352.5550 7


winding resistance Testing \\\\\\\\\\\\\\\\\\\\\\\\\\\\\\

Vanguard WRM-10 Raytech WR-50-12

 ingle channel winding resistance test set


S
 utomatic current from 10mA to 10A
A
 igital resistance reading from 1 to 2000 s
D
 ual input channels measure two winding
D
resistances simultaneously
 utomatic discharge of stored energy at the end
A
of every test
 imple menu driven operation
S
 ightweight and portable
L

 wo channel winding resistance test set


T
 ffers new demagnetizing feature
O
Raytech WR-50-1 / WR-50-2  0A output for testing large transformers
5
 measurement channels and onboard
2
printer convenience
 olor coded connections for easy setup
C
 astest discharge unit on the market
F

Store results using USB data storage device
 ouch screen interface
T
 ptional Heat Run Software and Three RTD Inputs
O

 wo channel winding resistance test set


T  ouch screen interface
T
 0A output for testing large transformers
5  nboard printer
O
with repeatable readings  ptional Heat Run Software and Three RTD
O

Color coded connections for easy setup inputs
 astest discharge unit on the market
F 
WR -50-1 is an optional power source
 tore results using USB data storage device
S designed to be used with the Raytech
Micro-Jr/Micro-Jr 2

8 protecequip.com 972.352.5550 | toll free 866.352.5550


Transformer Turn Ratiometers \\\\\\\\\\\\\\\\\\\\\\\\\\\\\\

Vanguard ATRT-03 AEMC DTR8500 Vanguard ATRT-01 / ATRT-01B

 ingle phase TTR


S 
Single phase TTR
 easure power, potential (PT) and current
M  easures turns-ratios from .8 to 15000
M
 utomatic three phase TTR
A (CT) transformer ratios  alculate turn-ratio in percentage
C
 easures turns-ratios from .8 to 15000
M  irect readings from .8 to 1500
D  easure and displays winding excitation
M
Internal data storage of 112 test results and  isplay turns ratio, polarity and excitation
D current and polarity
128 test plans current simultaneously  tand alone or computer controlled
S
 utomatically detects 130 different
A  isplays incorrect lead connections, reverse
D 
ATRT -01 line powered unit
transformer configurations polarity, open and short circuit warnings 
ATRT -01B battery powered unit
 n board thermal printer
O
 xport results using RS-232 and USB ports
E

Raytech TR-SPY Mark II

 utomatic three phase TTR


A
 elect transformer type using simple user interface
S
 easure voltage/turns ratio, current and
M
phase displacement
 tore 100 test results on unit or export using
S
RS-232 interface
 atio measurement of .08 to 13000 turns
R
 ive test voltage ranges 1V, 10V, 40V,
F
100V and automatic
 utomatic phase vector detection
A

protecequip.com 972.352.5550 | toll free 866.352.5550 9


\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\ Sweep Frequency Response Analyzers

Doble M5200 / M5400

 weep frequency response analyzer


S Easy setup and automated testing
 nalyze the winding relationship inside a
A  requency response measurement from
F
transformer 10 HZ to 25 MHZ
 etect mechanical failure or movement of
D
windings

Applications assistance and tech support


from field-experienced personnel

protecequip.com 972.352.5550 | toll free 866.352.5550 11


Oil testing \\\\\\\\\\\\\\\\\\\\\\\\\\\\\\

High Voltage DTS-60D Megger OTS-60PB

 0kV oil dielectric test set


6  0kV oil dielectric test set
6
 rovides repeatable, accurate
P  ully automatic portable oil test set
F
measurement of breakdown voltage
 est Voltage: 60kV maximum
T
of insulating oils
(30kV-0-30kV)
 rc detection with automatic
A
Internal rechargeable battery 12V, 12Ah
shutdown
 reprogrammed national specifications
P
 hree rates of rise:
T
 esolution is 1kV
R
500V/2000V/3000V per second
 est insulating oils per ASTM and
T
IEC specifications

Hipotronics OC60D Megger OTS-60SX


60kV oil dielectric test set
 0kV oil dielectric test set
6  ightweight, semi-automatic, oil dielectric
L
 est the dielectric strength of
T strength test set
insulating liquids used in electrical 
High voltage output of 0-60kV
apparatus  ransformer rating of 500VA
T

Output voltages to 60kV 
Semi automatic operation with selectable
 est insulating oils per ASTM and
T 500/2000/3000 V/s rise rate
IEC specifications  ause function with automatic 1 minute
P
 utomatic high voltage shutdown at
A timer for withstand testing
breakdown 
Test insulating oils per ASTM and
IEC specifications

12 protecequip.com 972.352.5550 | toll free 866.352.5550


\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\ Phase Sequence / Motor Rotation Indicators

Amprobe PRM-1

Peace of Mind
 ur equipment will arrive at your
O

Dual-function tester for correct phase sequence of line
jobsite complete, calibrated, and in
voltage and motor rotation
like new condition.  oltage range from 20 to 600V RMS
V

Integrated test leads
 e are available 24/7 for
W
emergency service and application
assistance.

 ersonalized service ensures your


P
needs are met.

 ll shipments are monitored to


A
ensure timely delivery and minimize
complications.

 e understand the time-critical


W Tri-State TSW-45
nature of your requirements and
respond accordingly.

5kV phase sequence indicator
 etects open phases
D

Instant phase rotation indication

protecequip.com 972.352.5550 | toll free 866.352.5550 13


CT / PT Testing \\\\\\\\\\\\\\\\\\\\\\\\\\\\\\

Adwel CTX-2000 Megger MCT1600

1 200V CT test set


 erforms saturation, ratio and polarity tests
P
1 .5A output current

Automatic display of ratios up to 2000:1
 est internal bushing CTs inside transformers
T
or switchgear
 igital metering
D


1600V CT test set
 icroprocessor controlled variable voltage
M
output for automatically testing single and
Megger CTER-91 multi-ratio CTs
 utomated testing of demagnetization, CT
A
Ratio, Knee Point, Saturation, Polarity and
Phase Deviation

1000V CT test set 
Ability to plot and simultaneously display up
to 10 CT saturation curves with knee point
 erforms saturation, ratio and polarity tests without
P
changing leads  s can be tested mounted in transformers,
CT
oil circuit breakers or switchgear
 est CTs mounted in transformers or switchgear
T
Integrated 1kV DC insulation test system

Provides a variable-voltage output up to 1000V
 olor daylight viewable graphical display
C
 recision instrumentation for testing single and
P
multi-ratio CTs  Save & Print Later with USB stick

Run/Hold switch freezes readings on instruments 
Fast data entry using full QWERTY keyboard
when switched to Hold  utomatic or manual testing
A

14 protecequip.com 972.352.5550 | toll free 866.352.5550


\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\ CT / PT Testing

Vanguard EZCT Vanguard EZCT-10

 utomatic CT excitation, CT current-ratio,


A
and winding polarity test set
 est voltage is adjusted automatically after selecting
T
the appropriate CT excitation test
 ny of the 10 possible combinations of
A
X1-X5 can be tested
 urrent ratio measuring range from 0.8 to 5000 to 1
C
 perate as a stand-alone unit or computer control using
O
RS-232 and USB interfaces
 Ratio and excitation knee point calculated and
CT
charted automatically
 rint test results using onboard thermal printer
P
 an supply variable test voltage 50VAC at 10A and
C
200VAC at 10A, 1200V at 1.5A

 utomatic CT excitation, CT current-ratio,


A
and winding polarity test set
 xcitation voltages up to 1200V, Current to 2A
E Vanguard EZCT-2000A / EZCT 2000B
 s can be tested mounted in transformers,
CT
oil circuit breakers or switchgear
 utomatic CT excitation, CT winding resistance,
A
 perate as a stand-alone unit or computer control
O and CT current-ratio test set
using RS-232 and USB interfaces
 onnect test leads to CT Terminals X1-X5 and
C
 Ratio and Excitation Knee point calculated and
CT eliminate lead switching during testing
charted automatically
 s can be tested mounted in transformers,
CT
 urrent ratio measuring range from
C oil circuit breakers or switchgear
0.8 5000 to 1 CT Ratios
 Ratio and Excitation Knee point calculated and
CT
 ecall and print test records using
R charted automatically
onboard thermal printer
 urrent ratio measuring range from
C
0.8 5000 to 1 CT Ratios

DC winding resistance measuring range is 100 to 10
 rint test results using onboard thermal printer
P
 tore up to 140 CT test records or 128 CT test plans
S
 perate as a stand-alone unit or computer control
O
using RS-232 and USB interfaces
Can supply variable test voltages 50V & 250V at 10A,
500V at 5A, and 1500V at 1.2A (EZCT-2000A)
Can supply variable test voltages 50V & 300V at 10A,
500V at 5A, 1200V at 1.2A and 2000V at 1A
(EZCT-2000B)
Measures the CT secondary burden (EZCT-2000B)

protecequip.com 972.352.5550 | toll free 866.352.5550 15


Circuit Breaker Testing

Primary Current Injection . . . . . . . . . . . . . . . . . . . . .17 Digital Low Resistance Ohmmeters (DLRO) . . . 20


Electrical Test Instruments PI-1600 AEMC 5600
Electrical Test Instruments PI-4000B Megger DLRO-10, -10X, -10HD
Megger CB-832 Raytech Micro JR / Micro JR 2
Megger CB-845 Raytech MicroCenturion II
Megger MS-2 Vanguard Auto-Ohm
Phenix HC-1
SMC LET-400 Circuit Breaker Tester /
Timer and Travel Analyzers . . . . . . . . . . . . . . . . . . . 22
Secondary Current Injection . . . . . . . . . . . . . . . . . 19 Vanguard CT-6500-3 / CT-6500-6
ABB Vanguard DigiTMR
Cutler Hammer
GE
Merlin Gerin
Siemens
Square D
Westinghouse

16
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\ Primary Current Injection

Electrical Test Instruments PI-1600 Electrical Test Instruments PI-4000B

Output current and overload information:

Max Input
11.5V 23 V Max On Max Off
Overload Duty Current at
(Par) (Ser) Time Time
480 / 240 V

4000 A 2000 A 1x 100% Continuous N/A 96 / 192

5600 A 2800 A 1.4x 50% 15.0 Min. 15 Min. 134 / 268

8000 A 4000 A 2x 25% 5.0 Min. 15 Min. 192 / 384

12000 A 6000 A 3x 10% 1.5 Min. 15 Min. 288 / 576

16000 A 8000 A 4x 6% 45.0 Sec. 15 Min. 384 / 768

 0,000A high current test set


4 20000 A 10000 A 5x 4% 4.0 Sec. 2 Min. 480 / 960
 5KVA continuous will test up to
4
28000 A* 14000 A* 7x 2% 2.0 Sec. 2 Min. 672 / (1344*)
4000A circuit breakers
1 6,000A high current test set  08-240 or 480V input
2 40000 A* 20000 A* 10x 1% 1.0 Sec. 2 Min. 960 / (1920*)
 ugged, modular construction improves durability
R 1 /2 and 3/4 output stabs, input
and transportation logistics cables, and output cabling provided * Available with 480 VAC input only; Max ON Times may
1 /2 and 3/4 output stabs, input cables, be less at 208 or 240 VAC
and output cabling provided

Output current and overload information:


Max Input
Megger CB-832
5.0V 10 V Max On Max Off
Overload Duty Current
(Par) (Ser) Time Time
at 240V

1600 A 800 A 1x 100% Continuous N/A 37  igh-current circuit breaker and


H
overload relay test set
2250 A 1125 A 1.4x 50% 15.0 Min. 15 Min. 52
 output ranges to meet a variety of test
3
3200 A 1600 A 2x 25% 5.0 Min. 15 Min. 74 circuit impedances
0 to 500A @ 3.5V max
4800 A 2400 A 3x 10% 2.5 Min. 20 Min. 111
1 to 125A @ 14V max
6400 A 3200 A 4x 6% 75.0 Sec. 20 Min. 148 0 to 25A @ 70V max
 est the time-delay characteristics of magnetic
T
8000 A 4000 A 5x 4% 4.0 Sec. 2 Min. 185
overload relays rated to 500A
11200 A 5600 A 7x 2% 2.0 Sec. 2 Min. 259  est the time-delay characteristics of thermal
T
devices rated up to 225A
16000 A 8000 A 10x 1% 0.6 Sec. 1 Min. 370
Instantaneous trip testing of 1800A through a
25000 A** 12500 A** 15x 0.5% 0.1 Sec. 1 Min. 555** typical 225A molded-case circuit breaker
 igital memory ammeter and multi-range timer
D
**Maximum output current possible into short circuit
with very low source impedance
protecequip.com 972.352.5550 | toll free 866.352.5550 17
Primary Current Injection \\\\\\\\\\\\\\\\\\\\\\\\\\\\\\

Megger CB-845 Phenix HC-1

 igh current test set


H
 ontinuous current to 1200A at 6V max
C
Instantaneous current to 5000A
 est the time-delay characteristics of magnetic
T
overload relays rated to 500A
 olid-state digital ammeter with multiple ranges and a
S
read-and-hold memory
 olid-state digital timer measures the elapsed time of
S
the test in either seconds or cycles
 ugged, modular design makes the unit portable
R 1 000A high current test set
Input voltage 208 and 240V (switch selected), 30A Instantaneous current to 1000A or
continuous current to 240A @ 3V
 igital current meter (memory or continuous)
D
 igital timer (cycle or seconds)
D
 ugged and portable
R

Megger MS-2 SMC LET-400

 00A high current test set


6
 ightweight and portable
L
 igital current meter (memory or continuous)
D
 igital timer (cycle or seconds)
D

 00A, 1kVA high current test set


4
 ultiple output taps to better adapt
M
voltage range to load impedance
 uilt in digital ammeter and timer
B
 utomatic thermal trip protection
A

18 protecequip.com 972.352.5550 | toll free 866.352.5550


\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\ Secondary Current Injection

Secondary Current Injection

Manufacturer Model Application

ABB 504 Power Shield

ABB 606 Micro Power Shield (MPS)

ABB 607 Micro Power Shield (MPS-C)


Micro Power Shield
ABB BTSB
(MPS-C & MPS-C 2000)
ABB PRO10/T SACE
ABB 606 ?

Cutler Hammer 1232C50G05 Seltronic and Digitrip

Cutler Hammer 1232C50G10 Seltronic and Digitrip

Cutler Hammer 140D481G02 Amptector

Cutler Hammer 140D481G03 Amptector and Digitrip ABB 606 Cutler Hammer 1232C50G05 GE PST1-1
Cutler Hammer 70C1056G52 Digitrip 310+ Test Kit

Cutler Hammer 140D481G10 Seltronic

Cutler Hammer 8779C02G03 Adaptor for DS and DSII

Cutler Hammer 8779C02G04 Adaptor for Magnum DS

Cutler Hammer 7801C57 Optimizer

Cutler Hammer MTK1000 Magnum DS

Cutler Hammer PRTAAPM Digitrip Power Supply

GE PST1-1 Power Sensor

GE TAKTS1 ECS and SST


Secondary Injection Test kit for
GE GTUTK20
EntelliGuard TU Trip Units
Power +, RMS9, Epic (TS), Merlin Gerin 34547 Siemens PTS-3 Square D S33595
GE TVRMS2
MVT Plus, MVT PM
MicroVersaTrip, TP4VT,
GE TVTS1
TP9VT, TAVT, T4VR
Merlin Gerin 34547 ME Test Kit

Merlin Gerin 685836A Masterpact

Siemens PTS-3 Static Trip I and Static Trip II Equipment manuals are available for
Siemens PTS-4 Static Trip I, Static Trip II, Static Trip II
download at no charge on our website.
Siemens TS-31 JD, LD, MD, PD, SB, STD

Siemens WLTS WL Breakers


Universal Test Set for
Square D UTS-3
Micrologic trip units
protecequip.com
Square D CBTM3 Module for UTS

Square D CBTM4A Module for UTS


Westinghouse SPBTPK
Square D CBTMB Module for UTS
Full function secondary injection test
Square D S33595
set for Micrologic trip units
Westinghouse 1255C48G02 SCB II

Westinghouse SPBTPK Pow-R-7

protecequip.com 972.352.5550 | toll free 866.352.5550 19


Digital Low Resistance Ohmmeters (DLRO) \\\\\\\\\\\\\\\\\\\\\\\\\\\\\\

AEMC 5600 Megger DLRO-10HD

1 0A DLRO
 easures resistance from 2000 to 200
M
 ix selectable current ranges from 10mA to
S
10A
 everse polarity switch
R
 attery powered with built in charger
B

Megger DLRO-10 / DLRO-10X 1 0A DLRO  eavy Duty Construction


H
 utomatically selects the most appropriate
A 1 0 A for 60 seconds
current, up to 10A DC  igh input protection up to 600 V
H
 easures resistance from 0.1 to 2000
M  otary mode switch for ease of use
R
on one of seven ranges
 uto current reversal cancels standing EMF
A
 etects continuity in potential and current
D
connections
 isible warning of high voltages present at the
V
terminals
 isible warning of current flowing in the test
V
sample
 ultiple operating modes including fully
M
automatic
 use protected to 600V
F
 ull range of test leads available with probes,
F
clamps and Kelvin clips

Additional features for 10X


 lpha-numeric keypad
A
 djustable high and low limits
A
 utoranging with manual option
A
 rinter output and memory
P

20 protecequip.com 972.352.5550 | toll free 866.352.5550


\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\ Digital Low Resistance Ohmmeters (DLRO)

Vanguard Auto-Ohm Raytech Micro JR / Micro JR 2

1 0A DLRO
 elect 10, 1, 0.1, 0.01, 0.001A DC
S
 easures resistance from 0.1 to 400 k
M
 utomated measurement detection
A
and storage modes
 utomatic polarity reversal
A
 tore up to 2,000 test results
S
 rint test results using onboard thermal printer
P
 attery operated
B
 an be used with WR50-1 digital low resistance
C
50A power supply

1 00A DLRO
 ccurately measures resistance ranging
A
from 1 to 300 m
 utputs test currents from 10A to 100A
O Raytech MicroCenturion II
 vailable automatic test mode
A
 hree most recent resistance measurements
T
are stored internally  00A DLRO
2
 imple push button control from the front panel
S  utput range: 10A to 200A
O
 ontrolled rise/fall test current
C  igh precision measurements from .01 to 5
H
 tore up to 2,000 test results
S
 rovided with heavy duty alligator clamps
P
with 15 Cables
 rint test results using onboard thermal printer
P

protecequip.com 972.352.5550 | toll free 866.352.5550 21


Circuit Breaker Tester / Timer and Travel Analyzers \\\\\\\\\\\\\\\\\\\\\\\\\\\\\\

Vanguard CT-6500-3 / CT-6500-6

Leading
Technology
Available Now
 t Protec we pride ourselves on
A
offering the latest, field proven
technology. Because we deal with
so many industry leading
equipment manufacturers we have
the opportunity to review, test, and
Circuit breaker timer and travel analyzer  low-Close test feature accurately measures
S
identify the new equipment that is
Operates with insertion resistors contact travel during maintenance
best suited for your requirements.
up to 7000  perate unit directly or use computer control
O
Initiates breaker operation in multiple modes via USB and RS-232 interface
Trip/close coil current monitoring capabilities  hree transducer channels available for
T  ur research and relationships save
O
Monitors all three breaker poles simultaneously measuring velocity, stroke, over-travel,
you time. Renting the equipment
and bounceback
Available with up to 6 dry contact inputs from us saves you money.
 rint test results in tabular or graphic format
P
Detects main contact and insertion-resistor
using onboard thermal printer
contact on the same input channel

Applications assistance and tech support from


field-experienced personnel

22 protecequip.com 972.352.5550 | toll free 866.352.5550


\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\ Circuit Breaker Tester / Timer and Travel Analyzers

Vanguard DigiTMR
Substation Testing
1 2 3
As Easy As ABC DEF

Spend More Time Testing,


Less Time Training
Vanguards precision substation testing instruments are
designed to be intuitive and easy to use so that you can
focus on testing instead of wasting time in training. Our
versatile instruments oer a built-in thermal printer and
on-board test record storage so that tests can be conducted
in stand-alone mode in the eld. A computer interface is
C also oered so that tests can be easily conducted from a PC.
M

And all of our instruments are competitively priced to


Y

provide cost-eective accuracy. For a virtual experience of


CM

our instruments, check out the interactive demos on our site


 ircuit breaker timer and travel analyzer
C
MY

CY
at:
 ontact input channel detects main and insertion-
C
resistor contact times in milliseconds and cycles
CMY
www.vanguard-instruments.com/demos
K

Initiates breaker operation


 rip/close coil current monitoring capabilities
T
 onitors three breaker poles simultaneously
M Vanguard Instruments Company, Inc.
 low-Close test feature accurately measures
S www.vanguard-instruments.com
contact travel during maintenance 1520 S Hellman Avenue PHONE 909.923.9390
 apture results in tabular or graphic format
C Ontario, CA 91761 FAX 909.923.9391
USA EMAIL sales@vanguard-instruments.com
immediately with onboard printer
 omputer interface allows for data collection and
C
operational control Reliability Through Instrumentation.
 tore up to 150 test records and 99 test plans
S
on the unit
 implified connections with one main
S
contact assembly
 ingle transducer input
S

Transformer Circuit Insulation Winding Current Relay Vacuum


Turns-Ratio Breaker Resistance Resistance Transformer Test Bottle
Meters Analyzers Meter Meters Testers Equipment Testers

protecequip.com 972.352.5550 | toll free 866.352.5550 23


Relay Testing

Single phase Relay Test Sets . . . . . . . . . . . . . . . . . 25


Doble F2253
Doble F2700

Three phase Relay Test Sets . . . . . . . . . . . . . . . . . 26


Doble F6150
Megger MPRT 8430
Megger Pulsar
SMC Mentor 12

24
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\ Single phase Relay Test Sets

Doble F2253 Doble F2700

 ingle phase relay test set


S
 utput can be configured for one voltage and
O
one current, two voltages, or two currents
 oltage output up to 300V AC
V
 ultimode timer measures pickup/dropout time
M
in cycles, milliseconds or seconds
 igh accuracy and wide current range from 0.25 to
H
26A for testing relays, meters and transducers
 ultiple units can be connected for three
M
phase output
 imple front panel control
S
 ingle phase relay test set
S
 utput can be configured for one voltage,
O
one current, or two currents
 oltage output up to 300V AC or 400V DC
V
at 150VA continuous
 ulti mode timer, internal/external start
M
and stop operations
 urrent output up to 90A AC or
C
60A DC continuous
 ariable phase angle and frequency
V
 imple front panel operations
S

protecequip.com 972.352.5550 | toll free 866.352.5550 25


Three phase Relay Test Sets \\\\\\\\\\\\\\\\\\\\\\\\\\\\\\

Doble F6150 Megger MPRT 8430

Three phase relay test system  est any type of relay from 0.5A to 180A
T  hree phase relay test system
T
Automated procedures and standard test at a high power  p to four voltage and current or eight
U
templates ensure consistent test methods  interface (Ethernet or USB) and
PC current outputs
Manual testing available through control software for steady state, dynamic state, 
LCD touch screen for manual or
panel software and transient testing semiautomatic testing
Flexible test configurations with six  ll sources can be controlled from a PC
A  onstant output power of 200VA
C
independently controlled sources, for easy configuration for each test per current channel
each rated 150VA at 0-30A  rovides up to 300V RMS at 150VA and
P
30A RMS at 200VA per phase
Provided by Protec with pre-configured
laptop at no additional cost  aximum output current of 120A at 800VA
M
with four channels paralleled
 n board battery simulator provides DC
O
output voltages of 24, 48, 125 and 250V
 uilt in transducer testing capability
B
 en programmable inputs and six
T
programmable outputs
 tatic and dynamic testing capabilities
S

26 protecequip.com 972.352.5550 | toll free 866.352.5550


\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\ three phase Relay Test Sets

Megger Pulsar SMC Mentor 12

 hree phase relay test system


T
 ontrolled via a touch screen panel and rotary
C
selector, or use external keyboard and mouse
 ariable output: three phase current and voltage,
V
each 200VA or Six 100VA current channels
 lug and play amplifiers
P
 ight logic inputs and outputs
E
Integral battery simulator, timer, frequency,
and generator
 daptive integrated control permits simple
A
manipulation of voltage, current, phase angle,
frequency, timer functions, automated ramping,
 hree phase relay test system
T fault playback, harmonic restraint, and
 hree phase current and three phase voltage,
T dynamic fault simulation
each 150VA  n board VGA, Ethernet, USB, keyboard, mouse,
O
 odular design permits field reconfiguration
M and RS-232 ports
Independent battery simulator / timer module
 ariable phase angle and frequency
V Applications assistance and tech support from
 -232 or IEEE GPIB interface
RS field-experienced personnel

 anual control or automated interface through


M
Megger PulseMaster or AVTS Software

protecequip.com 972.352.5550 | toll free 866.352.5550 27


Hipots and Cable Testing

DC / VLF Hipots . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Tan Delta Bridges . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33


High Voltage PTS-75 / PTS-80 / PTS-130 / PTS-200 HV Diagnostics TD30
High Voltage VLF-4022CM HV Diagnostics TD60
High Voltage VLF-6022CM High Voltage TDB-60
HV Diagnostics HVA30
HV Diagnostics HVA60 Cable Locators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Amprobe AT-3000
AC Hipots . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Aquatronics S.D.A.D.
High Voltage ALT-60/120
 igh Voltage PFT-103CM / PFT-301CM /
H Time Domain Reflectometers . . . . . . . . . . . . . . . . 35
PFT-303CM / PFT-503CM / PFT-1003CM High Voltage TDR1669
Hipotronics TDR1130A
Megger CFL-510F
Megger PFL20-1500

28
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\ DC / VLF Hipots

3127_Circa-65_All_Product_Ad.pdf 8/26/09 11:09:18 AM


High Voltage PTS-75 / PTS-80 / PTS-130 / PTS-200

High Voltage, Inc. offers the smallest, lightest, reliable, and


most economical high voltage test equipment available.

CM

MY

CY

CMY

Model PTS-75 PTS-80 PTS-130 PTS-200


AC Hipots
Output 0-75kV, 10mA 0-80kV, 10mA 0-130kV, 10mA 0-200kV, 10mA Nearly half the size of others
One piece shielded cable
Construction Single Piece Single Piece Two Piece Two Piece output up to 50 kV
Most rugged design
Guard / Ground circuit 0-200 kVac@6kVA
Control
Weight
68 pounds 72 pounds 34 pounds 34 pounds Anti-static meters
10 kVac - 300 kVac
Tank Weight N/A N/A 82 pounds 150 pounds

High Voltage, Inc. can serve your needs for testing all types of substation apparatus,
 ombination high voltage DC hipots and
C aerial lifts, and cable. Our VLF technology, AC and DC Hipots, Oil Testers, and Fault Locators,
high voltage megohmmeters all offer superior design and features not found elsewhere.
ISO 9001 : 2008
1 0mA continuous duty output rating 31 County Rt. 7A Copake, NY 12516 Tel.: (518) 329-3275 Fax: (518) 329-3271 E-Mail: sales@hvinc.com Web: www.hvinc.com
 wo range voltmeter and five range current meter
T
 egohm readings at any output voltage
M

protecequip.com 972.352.5550 | toll free 866.352.5550 29


DC / VLF Hipots \\\\\\\\\\\\\\\\\\\\\\\\\\\\\\

High Voltage VLF-4022CM HV Diagnostics HVA30

 0kV VLF Hipot


4
 utput voltage is 0-40kV AC peak,
O
0.1 / 0.5 / 0.02 Hz sinusoidal
 oad rating: 1.1F @ 0.1 Hz, 2.2F @ 0.05 Hz,
L
& 5.5F @ 0.02 Hz
 apable of testing 25kV cable up to a maximum
C
distance of 10 Miles (depending on type)
 etering: Voltmeter -40 0 +40kVAC, Charging
M
current meter 0-100mA, and capacitance meter 0-6 F
 harging current and load capacitance meter included
C
 wo piece design
T

 0kV VLF or DC hipot


3
High Voltage VLF-6022CM  F (0.1Hz), DC, cable fault conditioning (burning),
VL
and sheath/jacket testing modes included
 ully automatic or manual cable test sequences
F
 rue symmetrical sinusoidal, load independent,
T
 0kV VLF Hipot
6 output waveform across full load range
 utput voltage is 0-60kV AC peak @
O  eal-time display of actual output waveform
R
50 Hz, 0.1 Hz 0.02 Hz, 0-62kV AC peak @ 60Hz
 asy to use, ergonomic, menu guided, large
E
 oad rating: 1.1F @ 0.1 Hz, 2.2 F @ 0.05 Hz,
L backlit user interface
& 5.5 F @ 0.02 Hz
 ugged, one piece design
R
 apable of testing 35kV cable up to a maximum
C
 arge output load capability (up to 5F)
L
distance of 10 Miles (depending on type)
 utomatic and integrated load capacitance
A
 oltmeter: 0-60kVAC
V
measurement with optimum frequency selection
 harging current meter: 0-100mA
C
 tore test results in integrated memory our
S
 oad capacitance meter: 0-6F
L download to PC/laptop
 0 ft shielded output cable and 10 ft interconnect cable
2
 wo piece design
T

30 protecequip.com 972.352.5550 | toll free 866.352.5550


\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\ DC / VLF Hipots

HV Diagnostics HVA60

 0kV VLF or DC Hipot


6  arge output load capability (up to 15F)
L
 F (0.1Hz), DC (), Cable Fault Conditioning
VL  utomatic and integrated load capacitance
A
(Burning), and Sheath/Jacket Testing modes all measurement with optimum frequency selection
included  torage of test results for later retrieval or
S
 ully automatic or manual cable test sequences
F download to a PC/Laptop
complying with International Standards/Guides  hort circuited protected with active arc
S
 rue symmetrical sinusoidal, load independent,
T management regulation that avoids the usual
output waveform across the full load range nuisance tripping of conventional HV test
 eal-time display of actual output waveform
R equipment
 asy to use, ergonomic, menu guided, large
E  eamless integration with HV Diagnostics TD60
S
backlit user interface tan delta system
 ugged, one piece portability
R

protecequip.com 972.352.5550 | toll free 866.352.5550 31


AC Hipots \\\\\\\\\\\\\\\\\\\\\\\\\\\\\\

High Voltage PFT-103CM / PFT-301CM / PFT-303CM / PFT-503CM / PFT-1003CM High Voltage ALT-60/120

 0kV or 120kV AC Hipot


6
 our-range volt meter
F

AC hipots  ll units feature continuously adjustable
A  uty cycle: 4kVA continuous or 7kVA
D
 kVA models include a dual range
3 output voltage control, external safety one hour on, two hours off
kilovoltmeter and triple range output interlock, zero start safety interlock
 ual tap 60kV or 120kV
D
current meter  0 Shielded output cable with alligator clamp
2
 wo piece design
T

Model Output Capacity Weight

1kVA Resistive Load


PFT-103CM 0-10kVAC 62 pounds
3kVA Capacitive Load

1kVA Resistive Load


PFT-301CM 0-30kVAC 45 pounds
1kVA Capacitive Load

1 kVA Resistive Load


PFT-303CM 0-30kVAC 75 pounds
3kVA Capacitive Load

1 kVA Resistive Load


PFT-503CM 0-50kVAC 75 pounds
3kVA Capacitive Load

1 kVA Resistive Load 35 pound control


PFT-1003CM 0-100kVAC
3kVA Capacitive Load 85 pound tank

32 protecequip.com 972.352.5550 | toll free 866.352.5550


\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\ Tan Delta Bridges

HV Diagnostics TD30 HV Diagnostics TD60

 -30kV tan delta bridge


0
 ompact and battery operated
C
 olid state, air insulated design
S
 onfiguration and data extraction through
C
Bluetooth connection
 upplied with complete analysis software
S
 eal time display of actual output waveform
R
 uitable for use with HV Diagnostics
S
HVA30 VLF system

HV Diagnostics TD60

 0kV tan delta bridge


6
 ompact and battery operated
C
 olid state, air insulated design
S
 onfiguration and data extraction through
C
Bluetooth connection
 upplied with complete analysis software
S
 eal time display of actual waveform
R
output and data
 uitable for use with HV Diagnostics
S
HVA60 VLF system

High Voltage TDB-60

 -60kV tan delta bridge


0
 ill work with any VLF AC instrument
W
 oltage range: 0 - 60kV peak
V
 requency range: 0.01 Hz - 0.2 Hz
F
 ull report generating software
F
 isplays loss angle, voltage, current, &
D
frequency

Applications as-
sistance and tech
support from
field-experienced
personnel
protecequip.com 972.352.5550 | toll free 866.352.5550 33
Cable Locators \\\\\\\\\\\\\\\\\\\\\\\\\\\\\\

Amprobe AT-3000

We Are Not
Just A Rental
 nderground locator
U Company
 ocates underground energized and de-energized
L
wires, cables, and pipes
 hree testing modes for best accuracy
T  e also buy, lease, and sell test
W
Power
equipment.
Radio
Induced Signal
 epth measurement up to 10 feet
D  e offer inventory management,
W
repair, and calibration services.

 all us to learn more about how we


C
can help your business.

Aquatronics S.D.A.D.

 coustic fault detector


A
 ual channel system designed to work with
D
any brand thumper
 hree modes of operation: Direction-to-Fault,
T
Distance to Fault, Fault Depth indication
 wo earth probe microphones
T
 wo tripods for use on hard surfaces
T

34 protecequip.com 972.352.5550 | toll free 866.352.5550


\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\ Time Domain Reflectometers

High Voltage TDR1669 Megger CFL-510F

 able fault locator / Time domain reflectometer


C
 ocate faults on metallic cables
L
 and held and compact
H
 ast find key automatically adjusts range, gain,
F
and cursor to find major events
 ocates faults in six ranges from 30 to 10000 feet
L
 ariable velocity factor from 0.2 to 0.99
V
in steps of 0.01
Internal matching networks to allow testing of
power, cellular, CATV, and telephone cable

 ime domain reflectometer


T Hipotronics TDR1130A Megger PFL20-1500
 esigned for use with impulse generators
D
(Thumpers) and arc reflection systems
 aptures and holds the waveform created
C
when a thump causes a fault to arc to ground.
 anges of 500 (default), 1500, 3000, 6000,
R
12000, 24000 and 48000 feet are available
 oggle between live trace TDR mode and Arc
T
Reflection mode
 old function for freezing the thumped waveform
H
during the Arc Reflection mode
 tores up to 15 traces in memory
S
 efault setting of Auto Range and Auto Locate
D
(can be overridden)
1 0.5 color LCD display with two halves; lower half  ime domain reflectometer
T  ower Cable Fault Locator System
P
for live waveforms and top for reference or memory  imple soft key interface
S  n-board inverter
O
 - 232 interface for easy data transfer
RS Internal storage for 16 traces  rc Reflection
A
 ptimal tool for fault pre-location
O  ime Domain Reflectometry
T
Minimize impact to cable Impulse Current
Identify fault within inches  igh Voltage Surge
H
 an be integrated with most
C  roof and Burn
P
popular thumpers

protecequip.com 972.352.5550 | toll free 866.352.5550 35


Power Analysis and
Data Acquisition

Power Quality / Power Recorders . . . . . . . . . . 37 Oscilloscopes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40


Amprobe DM-III Multitest Fluke 123
Amprobe DM-II Pro Fluke 192 / 196
Dranetz PX5
Fluke 430 Series Phase Angle Meters . . . . . . . . . . . . . . . . . . . . . . . . . . .41
Fluke 1750 Dranetz 314
Hioki 3196 SMC PME-20-PH

Chart Recorders . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Astromed Dash 8X
Astromed Dash 10
Astromed Dash 18

36
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\ Power Quality / Power Recorders

Amprobe DM-III Multitest Amprobe DM-II Pro

 igital recorder and data logger


D
 omes as a complete kit, CTs and PC software
C
are included with product
 orks with single and three phase systems
W
(Y and delta)
 apable of recording all parameters
C
(single or three phase) simultaneously
 ll readings are True RMS (TRMS)
A
 ser selectable rates allow recording from
U
one hour to several months
 eadings and charts can be viewed on the
R
DM-II LCD screen or downloaded to a PC
Intuitive, very easy to use, Windows compatible
PC software
 hree phase power quality analyzer
T  ine or battery powered
L
 easures and records up to 64 parameters,
M
single or three phase
Includes phase sequence indicator, ground tester,
and 1kV megohmmeter
 easures True RMS and a broad spectrum of
M
power quality parameters
Hioki 3196 Power Quality Analyzer
 harting and exporting recorded results is
C
simple and convenient
 eadings can be viewed during recording,
R
after recording, or after downloading  ower Factor
P
 ags, swells
S
 licker, transients
F
 aveform display
W
 our current and four voltage channels
F

protecequip.com 972.352.5550 | toll free 866.352.5550 37


Power Quality / Power Recorders \\\\\\\\\\\\\\\\\\\\\\\\\\\\\\

Dranetz PX5 Fluke 1750

 hree phase power quality analyzer


T
 ight channels, 4 voltage & 4 current
E
Intuitive color touch screen
 /DC applications
AC
 amples at 256 samples/cycle
S
Independent voltage & current triggering,
cross triggering
 igh-speed sampling and data capture
H
(1 microsecond/channel)
 etailed event characterization of RMS
D
variations and transients

THD /harmonic spectrum and TID/interharmonics  hree phase power quality recorder
T
spectrum to the 63rd
 utomatically records every power quality
A
 aptures IEEE 1459 parameters for non-sinusoidal
C parameter and event, on every cycle all the time
and advanced power systems

PDA wireless front panel interface provides a
 attery or AC power
B window into what the instrument is recording
 xpanded memory up to 128 MB
E  lukes intuitive power analyzer software allows
F
user to define thresholds after monitoring
 et up in minutes with self-identifying current
S
probes and single-lead voltage connections
 wap channels internally when connections are
S
not correct no need to reconnect wires
Fluke 430 Series 1 GB of internal storage

 hree phase power quality analyzer


T
 easure three phases with neutral at 200 kS/s on each
M
channel simultaneously
 ocate, predict, prevent and troubleshoot problems in
L
single or three-phase power distribution systems
 nalyze the trends using the cursors and zoom tools
A

38 protecequip.com 972.352.5550 | toll free 866.352.5550


\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\ Chart Recorders

Astromed Dash 8X Astromed Dash 10

1 0 channel portable chart recorder


Includes data capture and battery pack for
portable operation
 rints time, date, chart speed, and scale every 6
P
inches, with user annotation of up to 128 characters
 /D converter provides 12-bit resolution
A
 ront-panel 1.44MB 3.5 MS-DOS compatible
F
floppy drive permits storage of recorder setups,
or transfer of data to a PC for analysis

 channel portable chart recorder


8
 ortable and lightweight
P Astromed Dash 18
1 5 touchscreen display
 eal Time Signal testing including window,
R
slope/level, and event
1 8 channel chart recorder
 ame rate from 1/minute to 200000/
S
 ight weight and portable
L
second/channel
1 7 touch screen display
 rovided with AstroView Software
P
 ideo snapshot recording rates of up
V

RTD measurements
to 1 frame / second
 ype J, K, T, E, and N thermocouple measurements
T
 ingle ended voltage monitoring with
S
 ingle ended voltage monitoring with a max
S maximum input of 250V AC or DC
measuring voltage of 600V RMS with IHV1 Module
 ifferential voltage recording with a
D
 ifferential voltage recording with a max measuring
D maximum input of +/- 40V
voltage of 2 to 4 VFS with IBR1 module
 ridge measurement with a max input
B
voltage of +/-40V Differential
 ype J, K, T, E, and N thermocouple measurements
T
 3 GB hard drive
7
 ample rates from once per minute to
S
200000/second/channel
 eal time signal testing including window,
R
slope/level, and Event

protecequip.com 972.352.5550 | toll free 866.352.5550 39


Oscilloscopes \\\\\\\\\\\\\\\\\\\\\\\\\\\\\\

Fluke 192 / 196 Fluke 123

 scilloscope
O
 ual input 100 or 60 MHz bandwidth
D
 easure current to 4000A and voltage to
M
1kV at 200MHz
 lukeView Scopemeter software
F
Internal memory of 10 locations containing
two screens and setups each
 copeRecord mode will record 27,500
S
points per input
 emorizes the last 100 screens
M
 aveform compare mode can store
W
passing or failing waveforms for future analysis
 igh resolution color display
H
 ample rate up to 2.5 GS/s
S
 ivisions of 2mV 100V
D
 ual-input 40 MHz digital oscilloscope
D
 wo 5,000 counts true-RMS digital multimeters
T
 utomatic measurements
A
 ual-input TrendPlot recorder
D
 onnect-and-View trigger simplicity for
C
hands-off operation
 hielded test leads for oscilloscope,
S
resistance and continuity measurements
 p to 7 hours battery operation
U
 00V CAT III safety certified
6
 ptically-isolated interface for PC connection
O

40 protecequip.com 972.352.5550 | toll free 866.352.5550


\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\ Phase Angle Meters

Dranetz 314

We Are A Small
Business And
We Like That  hase angle meter
P
 ompares phase angle between current and current,
C
voltage and voltage, or current and voltage
 ual voltage and current inputs
D
 e dont answer to Wall Street
W
 ax input voltage is 230VAC
M
we answer to you.
 ax input direct reading current is 10A
M

 e have the flexibility to do what


W
makes sense.

 ell us what you need and we will


T
make it happen.

 et the personalized service that


G
you deserve. SMC PME-20-PH

 hase angle meter


P
 isplays results as + or - 180 or 0 - 360 degrees
D
 easures phase angle between two voltages,
M
two currents or voltage to current
 oltage input from 0.2 to 500V direct
V
 urrent input 0.1 to 25A RMS direct
C
 easures power factor (0 to +/- 1) and frequency
M
(40 to 500 Hz)
 nalog scale enables it to be used as a synchroscope
A
 echargeable batteries
R
 -232 connection for exporting data
RS

protecequip.com 972.352.5550 | toll free 866.352.5550 41


Insulation / Ground Testing

Ground Testers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 Insulation Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . 45


AEMC 2610 AEMC 1026
AEMC 3731 / 3711 AEMC 5060
Megger DET4TD Metrel 3103
Megger DET62D Metrel 2077
Metrel 2088 Megger 210400 / 210415
Megger S1-552/2 / S1-1052/2
Megger MIT510/2 / MIT520/2

42
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\ Ground Testers

AEMC 2610 AEMC 3711 / 3731

 lamp-on ground tester


C
 imple and fast - no leads, no auxiliary rods
S
or spacing requirements
 irect reading of ground resistance from
D
0.01 to 1200
 irect reading of continuity and ground
D
loop resistance
 irect reading of ground leakage or phase
D
current from 1mA to 30A RMS
 aw opening of 1.25
J
Includes a display hold function
 odel 3731 provides alarm and memory functions
M
(99 field measurements)

 round tester
G
 easures current shunted to ground caused
M
by insulation faults
 easures current to 200A AC
M
 xtremely sensitive clamp-on ammeter measures
E
as low as 500A AC leakage on differential current
 orks on grounded single and three phase networks
W
 arge aperture CT (3.1)
L

protecequip.com 972.352.5550 | toll free 866.352.5550 43


Ground Testers \\\\\\\\\\\\\\\\\\\\\\\\\\\\\\

Megger DET4TD Metrel 2088

 54 rated digital ground tester.


IP
 wo, three, and four point testing
T
 electable 25V and 50V output
S
 easure resistance from 0.01 to 20 K and earth
M
voltage up to 100V

 round tester
G
 wo, three , and four point ground resistance
T
 llows for fall of potential, point to point or
A
slope tests
Insulation testing up to 29.9 G with test voltages
of 50V to 1000V
Megger DET62D
 rue RMS current measurement 0.1 to 200A
T
(0.1 mA resolution)
 our wire soil resistivity measurement
F
 lamp on testing with optional current probes
C
 djustable output voltage
A
 ully automatic, three terminal digital earth tester
F  tore up to 1000 results on unit or transfer to
S
 round resistance can be measured directly
G computer via RS-232 connection
from 100 m to 2 k
 est Voltage: Maximum 50 Volts peak
T
 est Current: 200 Range: 1 mA AC,
T
2 k Range: 100 A AC

44 protecequip.com 972.352.5550 | toll free 866.352.5550


\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\ Insulation Testing

AEMC 1026 AEMC 5060

 kV automatic megohmmeter
5
 isplays test voltage, insulation resistance and
D
leakage current during test
 apacitance of the sample and discharge voltage is
C
displayed at the conclusion of the test
Insulation measurements from 30k to 10T
 djustable and programmable test voltage
A
(40 to 5100V)
 utomatic calculation of DAR, PI and DD values
A
 irect measurement and display of capacitance
D
and leakage current
 isplay resistance, test voltage and run time
D
 rogrammable test run times and PI ratio times
P
 utomatic discharge and display of discharge voltage
A
1 kV battery operated megohmmeter
 -232 interface for direct printing of results
RS
 rovides four functional tests:
P
1 28kB memory for storing field test data
DC voltmeter
AC voltmeter  emote operation from PC
R
Ohmmeter
Continuity tester
 est voltage combinations of 250V, 500V and 1000V
T
Insulation measurements from 1k to 4000M
 esistance measurement from 0.1 to 4000
R
Metrel 3103
 ontinuity test and beeper
C
 00VAC/DC test voltage range
6
 ata hold switch
D
 est button may be locked-on for three minutes for
T
1 kV automatic megohmmeter
hands-free operation
 hree different test voltages: 250, 500 and 1000V
T
 utomatic discharge when test button is released
A
 ide range of measured insulation resistance
W
(up to 2 G)
 utomatic discharge of equipment after
A
test is complete

protecequip.com 972.352.5550 | toll free 866.352.5550 45


Insulation Testing \\\\\\\\\\\\\\\\\\\\\\\\\\\\\\

Metrel 2077 Megger S1-552/2 / S1-1052/2


MIT510/2 / MIT520/2

 kV megohmmeter
5
 utomatic PI, DAR, and DD index calculations
A
 est voltages from 250V to 5kV in 50V steps
T
 djustable measurement timer from 1 second
A
to 30 minutes

AC and DC voltage measurement up to 600V
 utomatic discharge of capacitance loads
A
 igital and bar graph display
D
 easures insulation to 5 T
M
 ine or battery powered
L

 kV and 10kV megohmmeters


5

CATIV 600V
 igh output current 5mA for fast charging of
H
capacitive loads
Megger 210400 / 210415  esting up to 5kV for S1-552/2, MIT510/2, MIT520/2
T
 esting up to 10kV for S1-1052/2
T
 ine or battery powered
L
 igital/analogue backlit display
D
 utomatic IR, PI, DAR, SV and DD tests
A
 kV / 15kV analog megohmmeters
5
 easures to 15T
M
 10400 measures up to 100,000 M; provides
2
 232 and USB download of results
RS
output from 250V to 5kV
 10415 measures up to 100,000 M at 5kV and
2
up to 200,000 M at 10kV
 ine operated
L
 uitable for both step voltage and DAR testing
S

46 protecequip.com 972.352.5550 | toll free 866.352.5550


Battery Testing

Megger BITE 2P
SBS IBEX
SBS 2002
Albercorp CRT-400
Torkel 860

47
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\ Battery Testing

Megger BITE 2P SBS IBEX

 attery impedance test set


B
 imple, icon menu driven operation
S
 utomatically measures and stores data
A
through contact probes
 imple data management and report generation
S
through SBS Exmons Pro software
 ifteen modes of measured data storage capacity
F
1 0Ah to 6000Ah Maximum and 0.1 to
16.0V DC Measurement
 esolution: Impedance .001m,
R
10mV DC Voltage, .5C
 uto scaling and zero point adjustment functions
A

 attery impedance test set


B
 easures impedance and DC voltage for all lead-acid
M
and nickel-cadmium cells up to 7000 AH
 n-line testing requires no downtime
O Albercorp CRT-400 Torkel 860
 aximum battery string test voltage of 275V
M
(larger batteries can be sectioned)
 attery Load Unit
B
Internal integration with power DB and ProActiv
Battery Database Management Software  In Service testing
Internal storage for up to 300 tests and Includes load currents in parameters
2000 sets of readings  djustable alarm and shutdown
A
Immediate results documentation with  xpandable
E
built-in thermal printer  orkelWin software
T

SBS 2002
 loat Voltage
F
 igital hydrometer
D Readings
 easures specific gravity and
M Internal Cell Resistance
temperature Intercell Resistance
 utomatically temperature-
A  uto Ranging
A
compensated to 35C (77F)  ata Extraction and Analysis
D
 imple one-button test
S

protecequip.com 972.352.5550 | toll free 866.352.5550 48


Instrumentation and Controls

Power Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 Smart Communicators . . . . . . . . . . . . . . . . . . . . . . . . 55


Agilent N5750A Hart 375 / Hart 375 with Fieldbus
BK Precision 1601 Relcom FBT-6
Cutler Hammer PRTAAPM
Magna PS-12/480 Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Transcat 21052E Ametek JOFRA CTC-650A
Transcat 23232E Fluke / Hart 9140A
Vanguard UPS-S2 Transmation 1064P

Multifunction / Process Calibrators . . . . . . . 52


Altek 211
Altek 334A
Altek 820
Fluke 725
Fluke 744
Fluke 787
Crystal Gauges
Hand Pumps

49
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\ Power Supplies

Agilent N5750A BK Precision 1601 Cutler Hammer PRTAAPM

 rogrammable DC power supply


P 
AC / DC power supply  uxiliary power module for
A
 utput Voltage: 0 to 50VDC 2 meter
O Digitrip test sets
 utput Ratings
O
ranges: 0-25VDC and 0-50VDC
 oltage: 150V
V
 utput Current: 0 to 2A in 4 ranges:
O
 urrent: 5A
C
0-50mA, 0-0.2A, 0-0.5A, 0-2A
 ower: 750W
P
 ully automatic shutdown,
F
adjustable current limit

Magna PS-12/480

1 2A continuous current AC or DC power supply


1 20VAC input
 -140VAC, 12A up to 2kVA
0
 -190VDC, 10A (fully rectified and filtered)
0
 -240VAC, 2A up to 500VA
0
 -480VAC, 1A up to 500VA
0
 -335VDC, 2A (fully rectified and filtered)
0

protecequip.com 972.352.5550 | toll free 866.352.5550 50


Power Supplies \\\\\\\\\\\\\\\\\\\\\\\\\\\\\\

Transcat 21052E Vanguard UPS-S2

 4VDC power supply


2
 oad Range 0 25mA
L
 perates on standard or rechargeable batteries
O

 /DC power supply


AC
 urrent capability of 10A continuous in
C
All AC or DC voltage ranges
 ariable DC output voltage 0 - 300VDC at 10A max
V
Transcat 23232E
 ariable AC output voltage of 0 - 240VAC at 10A max
V
 ll output power sources are isolated
A
from primary source
1 10VAC or 240VAC selectable line power

 ingle output DC power supply


S
 electable constant voltage or constant
S
current modes
 ontinuously variable output 32V/3A
C

51 protecequip.com 972.352.5550 | toll free 866.352.5550


\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\ Multifunction / Process Calibrators

Altek 211 Altek 334A

 illiamp loop calibrator


M
 ources 0.00 to 24.00mA
S
 eads mA or percent up to 52mA
R
 igipot simplifies output adjustments
D
in percentages
 ower and measure two wire
P
transmitters simultaneously
 ead voltage from 0 to 100VDC
R


RTD calibrator
 ource and measurement of eight RTD
S
types at +/- .025% accuracy
 ource or measure in degrees Fahrenheit or Celsius
S
 uik-Chek switch instantly recalls three outputs;
Q
HI, LO & Set

Altek 820

 rocess calibrator
P
 alibrates milliamps, voltage, RTD,
C
thermocouple & frequency
 ultimeter measures AC/DC volts,
M
ohms & continuity
 ower and measure two wire
P
transmitters simultaneously
 ource and read 0.00 to 24.00mA
S

protecequip.com 972.352.5550 | toll free 866.352.5550 52


Multifunction / Process Calibrators \\\\\\\\\\\\\\\\\\\\\\\\\\\\\\

Fluke 725 Fluke 787

 attery powered multifunction process calibrator


B
 iew input and output on measure/source screen
V
 easures and sources thermocouple and RTDs
M
 ource/simulate volts, mA, thermocouples, RTDs,
S
frequency, ohms, and pressure
 easure/source pressure using any of 29 Fluke
M
pressure modules
 erform fast linearity tests with auto-step and
P
auto-ramp features

 igital multimeter and loop calibrator


D
 lear LCD with backlight
C
 easure, source and simulate DC loop current
M
with .05% accuracy and 1A resolution
Fluke 744 
DC current source/loop calibrator
 iew both mA and percent scale values at
V
the same time
 elect automatic mA output in slow ramp,
S
fast ramp or 25% staircase steps
 ocumenting multifunction calibrator
D
with Hart interface
 imultaneous input and output
S
 easure/source temperature, pressure,
M
voltage, current, resistance and frequency
 enu driven display ensures easy setup
M
 tores up to a full week of results and RS232
S
interface allows easy download to a PC
 hree operating modes: Measure, Source or
T
Simultaneous measure/source
Integrated Hart communication ability
 easure/source pressure using any of 29 Fluke
M
pressure modules

53 protecequip.com 972.352.5550 | toll free 866.352.5550


\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\ Multifunction / Process Calibrators

Crystal Gauges Hand Pumps

Beamex PGM SI Pressure HTP-10K


 neumatic Hand Pump, 300 PSI
P  ydraulic Hand Pump, 10,000 PSI
H
 tainless Steel and Glass Construction
S
 ugged and dependable
R Druck PV411
 ccuracy of 0.1%
A SI Pressure TP1-40
 niversal Hand Pump
U
 ultiple pressure units
M
- 28" HG to 600 PSI Pneumatic  neumatic Hand Pump, -28" HG to
P
 ressure ranges from 15 PSI to 10K PSI
P 600 PSI in One Pump
1 0kV PSI Hydraulic
 attery operated
B
1 /4 NPT Connection
Ralston 7100P Taylor 44S369
 neumatic Hand Pump, 200 PSI
P  neumatic Squeeze Bulb Calibrator,
P
160"H20 or 18 PSI
Available Pressure Ranges
Ralston DP0V
15 PSI 300 PSI 3,000 PSI Transcat 6215P
 neumatic Hand Pump, 80 PSI
P
30 PSI 500 PSI 5,000 PSI  wo Test Ports with Vernier
T  neumatic Hand Pump, 100 PSI
P

100 PSI 1000 PSI 10,000 PSI

Ralston XHGV
 ydraulic Hand Pump, 5,000 PSI
H

Other models and ranges available

Provided with optional tubing and


fitting kits for your specific application

protecequip.com 972.352.5550 | toll free 866.352.5550 54


Smart Communicators \\\\\\\\\\\\\\\\\\\\\\\\\\\\\\

Hart 375 / Hart 375 with Fieldbus

 mart communicator
S
 upports Hart and Foundation Fieldbus devices
S
Intrinsically safe
 arge, backlit touch screen LCD
L
 imple navigation through menu structure
S

Relcom FBT-6

 ieldbus monitor
F  hows when a device is added to or dropped
S
 utomatically tests segments and give
A from a segment
OK/BAD with no operator intervention  bility to store and download readings from
A
 easures segment DC voltage
M 8 segments via a USB port
 etects short circuits between segment
D  isplays device addresses and signal levels
D
cables wires and shield
 easures noise below, at and above
M
the Fieldbus frequencies

55 protecequip.com 972.352.5550 | toll free 866.352.5550


\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\ Temperature

Ametek JOFRA CTC-650A Fluke / Hart 9140A

 ry block calibrator
D
 5F to 662F
9
1 2 minutes from ambient to 660F
1 5 minutes from 662F to 212F
 rovided with 1/16, 1/8, 3/16, 1/4, 3/8,
P
1/2, and 1 inserts

 ry block calibrator
D
 igh temperature (122F-1202F) or
H
(33F-650F)
 ast heating time 10 minutes from power
F
up to stability at 1202F
 ast one key one function access
F
 -232 Interface
RS Transmation 1064P
 rovided with multihole insert 1/8, 3/16,
P
1/4, and 3/8
 .9 immersion depth
7
 hermocouple calibrator
T
 ual-function, hand-held digital temperature
D
indicator and calibrator
Other models and ranges available  imulates or measures four thermocouple
S
types J/K/T/E in either degrees Celsius or Fahrenheit

protecequip.com 972.352.5550 | toll free 866.352.5550 56


Inspection Equipment

Infrared cameras . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 Tachometers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60


Fluke Ti-55 Ametek 1726
Mikron 7515 / 7200v Monarch Nova Strobe Plus

Infrared Thermometers . . . . . . . . . . . . . . . . . . . . . . 59
Fluke 63
Fluke 66

57
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\ Infrared cameras

Fluke Ti-55 Mikron 7515 / 7200v

Infrared camera system


 ightweight and easy to use
L
 200 offers a visual light image in addition
7
to thermal image
 ull color high resolution images
F
 ully radiometric (measures temperature
F
of every pixel)
 emperature range of -40C to 500F
T
 utomatic focus and digital zoom
A
 n screen temperature range bar
O
 igh resolution infrared camera with Fusion Technology
H  nboard long life battery and image storage card
O
 erge infrared images with visual (visible light) images
M  0 frame/second update rate
6
 high contrast color LCD
5  -232, NTSC/PAL. Composite video,
RS
 ompactFlash memory cards store over 1000 IR
C s-view outputs (7200)
images plus temperature data  rovided with MicroSpec image review and
P
 aser pointer for easy targeting
L report generation software
 20 X 240 high resolution, low noise detector
3
 ensitive to .05C
S
 X, 4X, and 8X digital zoom
2

Fusion Technology From Mikron 7515 From Mikron 7515 From Mikron 7515 From Mikron 7515
From Fluke Ti55

From Fluke Ti55

From Mikron 7200V From Mikron 7200V From Mikron 7200V From Mikron 7200V

protecequip.com 972.352.5550 | toll free 866.352.5550 58


Infrared Thermometers \\\\\\\\\\\\\\\\\\\\\\\\\\\\\\

Fluke 63

We Make
Life Easy
Infrared thermometer
 easure -25 to 1000F with distance to spot ratio of 12:1
M
 e respond to requests for quotes
W
 ingle dot laser sighting system provides current
S
and max surface temperatures in minutes, not hours or days.
 missivity fixed at .095
E

 e can customize the invoicing


W
and ordering process to fit
your need.

 ur robust quality control program


O
ensures peace of mind.

 rotec is your single point of


P
contact for repair, calibration,
Fluke 66 and rental.

Infrared thermometer
1 2-point data logging
 aser guided sighting system for easy
L
targeting with 1% accuracy
 electable MAX, MIN, DIF and AVG functions
S
that display values instantly with Hi/Lo Alarm
 ptional RTD probe for contact measurements
O
 istance to spot ratio 30:1
D
 easures -32 to 600C (-25 to 1100F)
M

59 protecequip.com 972.352.5550 | toll free 866.352.5550


\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\ Tachometers

Ametek 1726 Monarch Nova Strobe Plus

 trobe tachometer
S
 igital display with fine and coarse
D
flash rate adjustment
 0-14,000 flashes per minute;
3
0.5-233.33 flashes per second
Internal phase shifting
 ix preset flash rates
S

 ual function digital tachometer


D
 anges to 99,999 RPM optical and 20,000RPM contact
R
 ptimal for contact and non-contact measurements
O
 ight character display, sixteen units of measure
E
 our memories (last, maximum, minimum and average)
F
 uilt in photoelectric pickup operates to a distance
B
of 12 inches

protecequip.com 972.352.5550 | toll free 866.352.5550 60


gas detection

Leak Detector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
DILO 3-033-R050 SF6

Moisture Analyzer . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
DILO 3-037-R050

Combustion Analyzer . . . . . . . . . . . . . . . . . . . . . . . . 62
Bacharach PCA 2

61
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\ gas detection

DILO 3-033-R050 SF6 DILO 3-037-R050

 oisture Analyzer
M
 ompact, lightweight
C
 ighly sensitive
H
 ouch-screen
T
 esults as quick as 15 seconds
R

AC or 8 hour battery

 eak Detector
L
 o radioactive source
N
 naffected by strong SF6 concentrations
U
 ot sensitive to any other gases
N
1 second response time
 naffected by moisture
U
Bacharach PCA 2

 ombustion Analyzer
C
 mart Sensors
S
 easure four gases simultaneously
M
 utomatic CO overrange protection
A
 ersatile power management
V
 raphic display
G

protecequip.com 972.352.5550 | toll free 866.352.5550 62


additional test Equipment

Dewpoint Analyzers . . . . . . . . . . . . . . . . . . . . . . . . . 64 Light Meters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65


Vaisala DM70 AEMC CA811 / CA813

Vacuum Bottle Testing . . . . . . . . . . . . . . . . . . . . . . 64 Decade Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65


Vanguard VBT-60 Prime Technology RTD-100

Phasing Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 Borescopes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65


HD Electric MARK II Everest VIT XL Pro

Barometer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 Ultrasonic Detectors . . . . . . . . . . . . . . . . . . . . . . . 65


Druck DPI740 UE System UltraProbe 100

63
\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\ additional test equipment

Vaisala DM70 Vanguard VBT-60 HD Electric MARK II

 acuum bottle tester


V  hasing kit
P
 ightweight (10 lbs.) and easy-to-use
L  arge auto ranging LCD reads to 50kV
L
1 0kV DC to 60kV in 5kV increments  ual Stick design optimal for phasing
D
 well time from 5 seconds to 2 minutes
D 1 5 Coiled Connection Lead
 ewpoint analyzer
D
 igital voltage and current display
D  vailable with 3 and 6 hot sticks
A
 esigned for industrial spot checking and
D
 lashover (failure) LED indication
F
field calibration
1 0 quick disconnect cable
 ast response, enhanced by Sensor Purge option
F
 imple control knob operation
S
 easures dewpoint, temperature, absolute and
M
relative humidity
 easurement ranges from -60 to 60C (-76 to 140F)
M

Druck DPI740

 recision pressure indicator


P
 hree modes of operation: Local, Sea and Altitude
T
 3 optional units of pressure measurement
2
include inHg, mbar and psi
 in/max recorded as a background task
M
in measurement mode
 ownload or output results using RS-232 connection
D

protecequip.com 972.352.5550 | toll free 866.352.5550 64


additional test equipment \\\\\\\\\\\\\\\\\\\\\\\\\\\\\\

AEMC CA811 / CA813 Prime Technology RTD-100 Everest VIT XL Pro


RTD simulator
 ight meter
L
 upports two, three, and four wire hookups
S
 esigned to measure a wide range of
D
at .01 percent accuracy
lighting types
 ix decades for precision adjustment
S
 emovable sensor for remote reading
R  orescope
B
 ange 10 to 1111.10
R

PEAK function (Model CA813) broader  5 8mm probe
2
light response  ull, 360 probe articulation
F
 AX function (Model CA811)
M  color LCD
5
 igital zoom and image capture
D
 utomatic or manual brightness control
A
 easures distance, skew and depth
M
 -232, S-Video, Composite BNC, and
RS
UE System UltraProbe 100 RCA Style Connector Outputs
 n-board, 16MB PCMCIA memory card
O

 ltrasonic inspection system


U
 ppropriate for leak detection of any gases in
A
pressurized or vacuum systems
 etects electric arc, corona, and tracking
D
Inspection and monitoring of bearings
 isual and audio indication of amplitude
V
 ight position sensitivity selection
E

65 protecequip.com 972.352.5550 | toll free 866.352.5550


PRODUCT INDEX
ABB Crystal Hart Megger (continued) Square D
504 . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Test Gauges . . . . . . . . . . . . . . . . . . 53 375 / 375 with Fieldbus . . . . . . . . 55 Pulsar . . . . . . . . . . . . . . . . . . . . . . . . 27 CBTMB . . . . . . . . . . . . . . . . . . . . . . . 19
606 . . . . . . . . . . . . . . . . . . . . . . . . . . 19 9140A . . . . . . . . . . . . . . . . . . . . . . . . 56 PFL20-1500 . . . . . . . . . . . . . . . . . . 35 CBTM3 . . . . . . . . . . . . . . . . . . . . . . . 19
607 . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Cutler Hammer S1-552/2 / S1-1052/2 / CTBM4A . . . . . . . . . . . . . . . . . . . . . 19
BTSB . . . . . . . . . . . . . . . . . . . . . . . . 19 1232C50G05 . . . . . . . . . . . . . . . . . . 19 HD Electric MIT510/2 / MIT520/2 . . . . . . . . . . 46 S33595 . . . . . . . . . . . . . . . . . . . . . . . 19
PRO10/T . . . . . . . . . . . . . . . . . . . . . 19 1232C50G10 . . . . . . . . . . . . . . . . . . 19 Mark II . . . . . . . . . . . . . . . . . . . . . . . 64 UTS-3 . . . . . . . . . . . . . . . . . . . . . . . . 19
140D481G02 . . . . . . . . . . . . . . . . . . 19 Merlin Gerin
Adwel 140D481G03 . . . . . . . . . . . . . . . . . . 19 High Voltage 34547 . . . . . . . . . . . . . . . . . . . . . . . . 19 TAYLOR
CTX-2000 . . . . . . . . . . . . . . . . . . . . 14 140D481G10 . . . . . . . . . . . . . . . . . . 19 ALT-60/120 . . . . . . . . . . . . . . . . . . 32 685836A . . . . . . . . . . . . . . . . . . . . . 19 44S369 . . . . . . . . . . . . . . . . . . . . . . 55
7801C57 . . . . . . . . . . . . . . . . . . . . . . 19 DTS-60D . . . . . . . . . . . . . . . . . . . . . . 12
AEMC 8779C02G03 . . . . . . . . . . . . . . . . . 19 PFT-103CM . . . . . . . . . . . . . . . . . . . 32 Metrel torkel
1026 . . . . . . . . . . . . . . . . . . . . . . . . . 45 8779C02G04 . . . . . . . . . . . . . . . . . 19 PFT-301CM . . . . . . . . . . . . . . . . . . . 32 2077 . . . . . . . . . . . . . . . . . . . . . . . . . 46 860 . . . . . . . . . . . . . . . . . . . . . . . . . . 48
2610 . . . . . . . . . . . . . . . . . . . . . . . . . 43 MTK1000 . . . . . . . . . . . . . . . . . . . . . 19 PFT-303CM . . . . . . . . . . . . . . . . . . 32 2088 . . . . . . . . . . . . . . . . . . . . . . . . . 44
3731 / 3711 . . . . . . . . . . . . . . . . . . . . 43 PRTAAPM . . . . . . . . . . . . . . . . . . . . 19 PFT-503CM . . . . . . . . . . . . . . . . . . 32 3103 . . . . . . . . . . . . . . . . . . . . . . . . . 45 Transcat
5060 . . . . . . . . . . . . . . . . . . . . . . . . 45 PFT-1003CM . . . . . . . . . . . . . . . . . .32 21052E . . . . . . . . . . . . . . . . . . . . . . . 52
5600 . . . . . . . . . . . . . . . . . . . . . . . . 20 dilo PTS-130 . . . . . . . . . . . . . . . . . . . . . . 29 Mikron 23232E . . . . . . . . . . . . . . . . . . . . . . . 52
CA811 / CA813 . . . . . . . . . . . . . . . . 65 3-033-R050 SF6 . . . . . . . . . . . . . . 62 PTS-200 . . . . . . . . . . . . . . . . . . . . . 29 7515 / 7200v . . . . . . . . . . . . . . . . . 58 6215P . . . . . . . . . . . . . . . . . . . . . . . . 55
DTR8500 . . . . . . . . . . . . . . . . . . . . . 9 3-037-R050 . . . . . . . . . . . . . . . . . . 62 PTS-75 . . . . . . . . . . . . . . . . . . . . . . . 29
PTS-80 . . . . . . . . . . . . . . . . . . . . . . .29 Monarch Transmation
Agilent Doble TBD-60 . . . . . . . . . . . . . . . . . . . . . . 33 Nova Strobe Plus . . . . . . . . . . . . . 60 1064P . . . . . . . . . . . . . . . . . . . . . . . . 57
N5750A . . . . . . . . . . . . . . . . . . . . . . 50 F2253 . . . . . . . . . . . . . . . . . . . . . . . . 25 TDR1669 . . . . . . . . . . . . . . . . . . . . . 35
F2700 . . . . . . . . . . . . . . . . . . . . . . . 25 VLF-4022CM . . . . . . . . . . . . . . . . . 30 Phenix Tri State
Albercorp F6150 . . . . . . . . . . . . . . . . . . . . . . . . 26 VLF-6022CM . . . . . . . . . . . . . . . . . 30 HC-1 . . . . . . . . . . . . . . . . . . . . . . . . . 18 TSW-45 . . . . . . . . . . . . . . . . . . . . . . 13
CRT-400 . . . . . . . . . . . . . . . . . . . . . 48 M4000 / M4100 . . . . . . . . . . . . . . . 5
M5200 / M5400 . . . . . . . . . . . . . . . 11 Hioki Prime Technology UE Systems
Altek 3196 . . . . . . . . . . . . . . . . . . . . . . . . . 37 RTD-100 . . . . . . . . . . . . . . . . . . . . . 65 UltraProbe 100 . . . . . . . . . . . . . . . . 65
211 . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 Dranetz
334A . . . . . . . . . . . . . . . . . . . . . . . . 52 314 . . . . . . . . . . . . . . . . . . . . . . . . . . 41 Hipotronics Ralston Vaisala
820 . . . . . . . . . . . . . . . . . . . . . . . . . . 52 PX5 . . . . . . . . . . . . . . . . . . . . . . . . . . 38 OC60D . . . . . . . . . . . . . . . . . . . . . . . 12 7100P . . . . . . . . . . . . . . . . . . . . . . . . 54 DM70 . . . . . . . . . . . . . . . . . . . . . . . . 64
TDR1130A . . . . . . . . . . . . . . . . . . . . 35 DPOV . . . . . . . . . . . . . . . . . . . . . . . . 54
Ametek Druck XHGV . . . . . . . . . . . . . . . . . . . . . . . . 54 Vanguard
1726 . . . . . . . . . . . . . . . . . . . . . . . . . 60 DPI740 . . . . . . . . . . . . . . . . . . . . . . . 64 HV Diagnostics ATRT-01 / ATRT-01B . . . . . . . . . . 9
JOFRA CTC-650A . . . . . . . . . . . . 56 PV411 . . . . . . . . . . . . . . . . . . . . . . . . 54 HVA30 . . . . . . . . . . . . . . . . . . . . . . . 30 Raytech ATRT-03 . . . . . . . . . . . . . . . . . . . . . . 9
HVA60 . . . . . . . . . . . . . . . . . . . . . . . 31 Micro Jr / Micro Jr. 2. . . . . . . . . . . . 21 Auto-Ohm . . . . . . . . . . . . . . . . . . . . . 21
Amprobe Electrical Test Instruments TD30 . . . . . . . . . . . . . . . . . . . . . . . . 33 Raytech MicroCenturion II . . . . . . 21 CT-6500-3 / CT-6500-6 . . . . . . . 22
AT-3000 . . . . . . . . . . . . . . . . . . . . . 34 PI-1600 . . . . . . . . . . . . . . . . . . . . . . . 17 TD60 . . . . . . . . . . . . . . . . . . . . . . . . 33 Raytech TR-SPY Mark II . . . . . . . . 9 DigiTMR . . . . . . . . . . . . . . . . . . . . . . 23
DM-II Pro . . . . . . . . . . . . . . . . . . . . . 37 PI-4000B . . . . . . . . . . . . . . . . . . . . . 17 WR-50-1 / WR-50-2 . . . . . . . . . . . . 8 EZCT . . . . . . . . . . . . . . . . . . . . . . . . . 15
DM-III Multitest . . . . . . . . . . . . . . . 37 Magna WR-50-12 . . . . . . . . . . . . . . . . . . . . . 8 EZCT-10 . . . . . . . . . . . . . . . . . . . . . . . 15
PRM-1 . . . . . . . . . . . . . . . . . . . . . . . . 13 Everest VIT PS-12/480 . . . . . . . . . . . . . . . . . . . . 50 EZCT-2000A / EZCT-2000B . . . 15
VIT XL Pro . . . . . . . . . . . . . . . . . . . 65 Relcom UPS-S2 . . . . . . . . . . . . . . . . . . . . . . .52
Aquatronics Megger FBT-6 . . . . . . . . . . . . . . . . . . . . . . . . 55 VBT-60 . . . . . . . . . . . . . . . . . . . . . . 64
S.D.A.D. . . . . . . . . . . . . . . . . . . . . . . 34 Fluke 210400/210415 . . . . . . . . . . . . . . . 46 WRM-10 . . . . . . . . . . . . . . . . . . . . . . . 8
63 . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 BITE 2P . . . . . . . . . . . . . . . . . . . . . . 48 SBS
Astromed 66 . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 CB-100 . . . . . . . . . . . . . . . . . . . . . . . . 7 2002 . . . . . . . . . . . . . . . . . . . . . . . . . 48 Westinghouse
Dash 8X . . . . . . . . . . . . . . . . . . . . . . 39 123 . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 CB-832 . . . . . . . . . . . . . . . . . . . . . . . . 17 IBEX . . . . . . . . . . . . . . . . . . . . . . . . . 48 1255C48G02 . . . . . . . . . . . . . . . . . . 19
Dash 10 . . . . . . . . . . . . . . . . . . . . . . 39 192 / 196 . . . . . . . . . . . . . . . . . . . . . 40 CB-845 . . . . . . . . . . . . . . . . . . . . . . 18 SPBPTK . . . . . . . . . . . . . . . . . . . . . . 19
Dash 18 . . . . . . . . . . . . . . . . . . . . . . 39 430 Series . . . . . . . . . . . . . . . . . . . . 38 CFL-510F . . . . . . . . . . . . . . . . . . . . . 35 SI Pressure
725 . . . . . . . . . . . . . . . . . . . . . . . . . . 53 CTER-91 . . . . . . . . . . . . . . . . . . . . . . 14 HTP-10K . . . . . . . . . . . . . . . . . . . . . 54
bacharach 744 . . . . . . . . . . . . . . . . . . . . . . . . . . 53 Delta 3000 . . . . . . . . . . . . . . . . . . . . 7 TPI-40 . . . . . . . . . . . . . . . . . . . . . . . 54
PCA 2 . . . . . . . . . . . . . . . . . . . . . . . . 62 787 . . . . . . . . . . . . . . . . . . . . . . . . . . 53 DET4TD . . . . . . . . . . . . . . . . . . . . . . 44
1750 . . . . . . . . . . . . . . . . . . . . . . . . . 38 DET62D . . . . . . . . . . . . . . . . . . . . . . 45 Siemens
Beamex 9140A . . . . . . . . . . . . . . . . . . . . . . . . 56 DLRO-10HD . . . . . . . . . . . . . . . . . . 20 PTS-3 . . . . . . . . . . . . . . . . . . . . . . . . 19
PGM . . . . . . . . . . . . . . . . . . . . . . . . . 53 Ti-55 . . . . . . . . . . . . . . . . . . . . . . . . . 58 DLRO-10 / DLRO-10X . . . . . . . . . 20 PTS-4 . . . . . . . . . . . . . . . . . . . . . . . . 19
MCT1600 . . . . . . . . . . . . . . . . . . . . . 14 TS-31 . . . . . . . . . . . . . . . . . . . . . . . . . 19
BK Precision GE MPRT8430 . . . . . . . . . . . . . . . . . . . 26 WLTS . . . . . . . . . . . . . . . . . . . . . . . . 19
1601 . . . . . . . . . . . . . . . . . . . . . . . . . . 49 PST1-1 . . . . . . . . . . . . . . . . . . . . . . . . 19 MS-2 . . . . . . . . . . . . . . . . . . . . . . . . . 18
TAKTS1 . . . . . . . . . . . . . . . . . . . . . . 19 OTS-60PB . . . . . . . . . . . . . . . . . . . . . 12 SMC
TVRMS2 . . . . . . . . . . . . . . . . . . . . . . 19 OTS-60SX . . . . . . . . . . . . . . . . . . . . . 12 LET-400 . . . . . . . . . . . . . . . . . . . . . 18
TVTS1 . . . . . . . . . . . . . . . . . . . . . . . . 19 Mentor 12 . . . . . . . . . . . . . . . . . . . . . 27
PME-20-PH . . . . . . . . . . . . . . . . . . . 42
Why Rent?
In todays operating environment, youre being asked to do more with
Our customers often point out that a rental strategy makes sense
less. Your organization must reduce costs, and renting equipment
because they are preserving precious capital thats really needed
delivers a number of benefits that can do just that.
now for payroll, taxes and other operational expenses that are not
easily financed by many banks today.
Lets start with Operational Benefits
For starters, when you rent from Protec you get top equipment in Next they say cost control comes into play as they allocate
top condition. This peace of mind will go a long way, and help you equipment costs on a project basis to ensure every job is profitable.
respond fast to whatever comes up. You can take advantage of the The project costs become fixed and clear and the business risks go
latest equipment, without worrying about how to finance the gear down. Renting allows you to expense or deduct these direct costs
you need now. Protec also offers the best application advice from a in the year they are incurred to match revenue with costs. Its worth a
knowledgeable, unbiased source. Should you decide you really need look...purchase behavior that made sense in years past may no longer
more equipment based on rental use, just buy it from us. hold the advantages you took for granted. Ask your business advisor.

What are the Fiscal Benefits? A final area where you can save with a rental strategy is in the hidden
(but necessary) costs of storage, calibration, repair and logistics. Fast
Many would say it takes money to make money. But when renting paced organizations realize this area alone may be the competitive
you can make money first with Protec equipment before you need difference they need to trim costs now and make bids as competitive
to worry about how to finance your expansion. Put another way, as possible.
unleash your growth potential knowing the right Protec equipment
is ready now.

Why Rent from


True cost of ownership for equipment is likely
Protec?
to be double the original purchase price. With advice like this, isnt it becoming pretty apparent why Protecs
smartest customers quickly become our best customers? They make
rental decisions and purchase decisions knowing they have every
PURCHASE COST option available.
VISIBLE COST
= Maintenance, calibration and repair
ALL equipment arrives in like new condition
Finance Costs
Two day travel allowance on all orders
Depreciation Technical Support and Customer Service Available is 24/7
Equipment management  ach piece of equipment comes with calibration certificate
E
HIDDEN COSTS = and tracking costs

Equipment obsolescence
at no additional cost

Reduced Performance and


Productivity over time
972.352.5550 / 866.352.5550 toll free
protecequip.com
Storage and Security

Disposal Costs
1517 W N Carrier PKWY, Ste. 116, Grand Prairie, Texas 75050 protecequip.com t 972.352.5550 f 972.352.5553 toll free 866.352.5550

Das könnte Ihnen auch gefallen