The PROFITEST INTRO provides professional electricians with a uni- age in order to detect weak points in the insulation and determine
versal, compact and rugged, state-of-the-art measuring tool. The tripping voltage for voltage limiting devices.
test instrument is capable of executing all measurements for test- Voltage at the device under test and any triggering/breakdown
ing the effectiveness of safety measures in electrical systems as voltage appear at the test instruments display.
required by IEC 60364-6 (DIN VDE 0100-600) and other country-
specific standards, and as specified in the individual sections of Low-Resistance Measurement
DIN EN 61557 (VDE 0413). Thanks to its intelligent and ergonomic Bonding conductor resistance and protective conductor resis-
design, intuitive operation and an advanced technical concept, its tance can be measured with a test current of 200 mA DC, auto-
aligned consistently to routine daily tasks making it the ideal compan- matic polarity reversal of the test voltage and selectable current
ion for any electrician. flow direction. If the adjustable limit value is exceeded, an LED
lights up.
Large Voltage and Frequency Ranges
A broad-range measuring device permits use of the test instru- Testing of Residual Current Devices (RCCBs)
ment in all alternating and 3-phase electrical systems with volt-
Testing of equipment and RCCBs with rising residual current
ages from 65 to 500 V and frequencies of 16 to 400 Hz.
including indication of tripping current and contact voltage
Loop and Line Impedance Measurement Testing for N-PE reversal
Measurement of loop and line impedance can be performed in Testing of RCCBs with the following nominal currents:
the 65 to 500 V range. Conversion to short-circuit current is
IN, 1 IN, 2 IN, (5 IN up to 100 mA)
based on the respective nominal line voltage, insofar as the mea-
sured line voltage is within the specified range. Measuring error for Selective S , SRCDs, PRCDs (Schukomat, Sidos and others),
the PROFITEST INTRO is also taken into account for conversion. types G/R, AC, A and F; types B, B+ and EV, MI
Outside of this range, short-circuit current is calculated on the Testing of RCCBs which are suitable for pulsating residual direct
basis of momentary line voltage and measured impedance.
and alternating current; testing is conducted with positive or neg-
Measurement of Insulation Resistance Using Nominal Voltage with Vari- ative half-waves
able or Rising Test Voltage
Insulation resistance is usually measured with a nominal voltage of
500, 250 or 100 V. A test voltage which deviates from nominal volt-
age, and lies within a range of 20/50 to 1000 V, can be selected for
measurements at sensitive components, as well as systems with
voltage limiting devices.
Measurement can be performed with a constantly rising test volt-
Phase Tester
Protective conductor potential is tested after starting a test Overview of Included Features
sequence and touching the contact surface for finger contact (by
pressing the START key). The PE symbol appears at the display if a PROFITEST INTRO (M520T)
potential difference of more than 25 V is detected between the Testing of residual current devices (RCDs)
contact surface and the protective contact at the mains plug. UB measurement without tripping the RCD
Tripping time measurement
Measurement of tripping current IF
Error Indication
Selective, SRCDs, PRCDs, type G/R
The instrument automatically detects instrument-to-system AC/DC sensitive RCDs, types B and B+, EV, MI
connection errors, which are indicated in a connection picto- Testing for N-PE reversal
graph. Measurement of loop impedance ZL-PE / ZL-N
Errors within the electrical system (no mains or phase voltage, Fuse table for systems without RCDs
tripped RCD) are indicated at two LEDs and by means of pop- Without tripping the RCD, fuse table
With 15 mA test current1, without tripping the RCD
up windows at the tilting LCD panel.
Earth resistance RE (mains operation)
I/U measuring method
Battery Monitoring and Self-Test Measurement of equipotential bonding RLO
Battery monitoring is conducted while the instrument is subjected Automatic polarity reversal
to an electrical load. Results are displayed both numerically and Insulation resistance RINS
with a symbol. Test images can be called up one after the other, Variable or rising test voltage (ramp)
and LEDs and the acoustic signal can be tested during the self- Voltage UL-N / UL-PE / UN-PE / f
test. The test instrument is shut down automatically when the bat- Special measurements
teries or NiMH rechargeable batteries (option) are depleted. A Phase sequence
microprocessor controlled charging circuit is used to assure safe Earth leakage resistance RE(ISO)
charging of rechargeable NiMH batteries. Voltage drop (U)
Features
Data Entry at the RS-232 Port Selectable user interface language 2
Data can be read in via a barcode or RFID scanner connected to Memory (database for up to 50,000 objects)
the RS-232 port, and comments can be entered with the help of RS 232 port for RFID/barcode reader
the softkeys. USB port for data transmission
ETC user software
USB Data Interface Measuring category: CAT III 600 V / CAT IV 300 V
Factory calibration certificate
Measurement data are transmitted to a PC via the integrated USB
port, at which they can be printed in report form and archived. 1 The so-called live measurement is only advisable if there is no bias current within
the system. Only suitable for motor protection switches with small nominal cur-
Software Update rent values.
2 Currently available languages: D, GB, I, F, E, P, NL, S, N, FIN, CZ, PL
The test instrument can always be kept current thanks to firm-
ware which can be updated via the USB port. Software is
updated during the course of recalibration by our service depart-
ment, or directly by the customer.
Characteristic Values
Nominal Ranges of Use
Voltage UN 120 V (108 132 V)
230 V (196 253 V)
400 V (340 440 V)
Frequency fN 16 Hz (15.4 18 Hz)
50 Hz (49.5 50.5 Hz)
60 Hz (59.4 60.6 Hz)
200 Hz (190 210 Hz)
400 Hz (380 420 Hz)
Overall voltage range 65 550 V
Overall frequency range 15.4 420 Hz
Waveform Sinusoidal
Temperature range 0 C + 40 C
Battery voltage 8 12 V
Line impedance angle Corresponds to cos = 1 0.95
Characteristic Values
Connections
Input
Func- Measured Reso- Measuring Nominal Measuring Intrinsic PRO-CH KS-PROFiTEST
Display Range Impedance /
tion Quantity lution Range Values Uncertainty Uncertainty PRO-GB INTRO
Test Current adapter
1 2-pin 3-pin
UL-PE 0.0 ... 99.9 V 0.1 V 1 (2% rdg.+5d) (1% rdg.+5d)
0.3 ... 600 V
UN-PE 100 ... 600 V 1V (2% rdg.+1d) (1% rdg.+1d)
UN = 120/230/ l l l
15.0 ... 99.9 Hz 0.1 Hz
f DC 15.4 ... 420 Hz 400/500 V (0.2% rdg.+1d) (0.1% rdg. + 1 d)
100 ... 999 Hz 1 Hz
5 M
U3~
0.0 ... 99.9 V 0.1 V
0.3 ... 600 V fN = 16/50/60/ (3% rdg.+5d) (2% rdg.+5d)
l
100 ... 600 V 1V 200/400 Hz (3% rdg.+1d) (2% rdg.+1d)
0.0 ... 99.9 V 0.1 V (3% rdg.+5d) (2% rdg.+5d)
UL-N
100 ... 600 V 1V
1.0 ... 600 V 1
(3% rdg.+1d) (2% rdg.+1d)
l l
+1% rdg. 1d
UIN 0.0 ... 70.0 V 0.1 V 0.3 IN 5 ... 70 V +13% rdg. + 1 d
+9% rdg. + 1 d
10 ... 999 1
I = 10 mA 1.05
1.00 k ... 6.51 k 0.01 k N
3 ... 999 1 UN =
I = 30 mA 1.05
1 k ... 2.17 k 0.01 k N 120 V
U IN = 100 mA
Calculated value
RE 1 ... 651 1 Off 230 V
IN 1.05 400 V 2
RE = UIN / IN
0.3 ... 99.9 0.1 IN = 300 mA
IF 100 ... 217 1 1.05 fN = 50/60 Hz
0.2 ... 9.9 0.1 IN = 500 mA
10 ... 130 1 1.05 UL = 25/50 V
l l
IF (IN = 6 mA) 1.8 ... 7.8 mA 1.8 ... 7.8 mA 1.8 ... 7.8 mA
IF (IN = 10 mA) 3.0 ... 13.0 mA 0.1 mA 3.0 ... 13.0 mA 3.0 ... 13.0 mA IN =
6 mA
IF (IN = 30 mA) 9.0 ... 39.0 mA 9.0 ... 39.0 mA 9.0 ... 39.0 mA
10 mA (7% rdg. + 2d) (3.5% rdg. + 2 d)
IF (IN = 100 mA) 30 ... 130 mA 1 mA 30 ... 130 mA 30 ... 130 mA 30 mA
IF (IN = 300 mA) 90 ... 390 mA 1 mA 90 ... 390 mA 90 ... 390 mA 100 mA
IF (IN = 500 mA) 150 ... 650 mA 1 mA 150 ... 650 mA 150 ... 650 mA 300 mA
UI / UL = 25 V 0.0 ... 25.0 V 0 ... 25.0 V 500 mA 2 +1% rdg. 1d
0.1 V Same as I +10% rdg. + 1 d
UI / UL = 50 V 0.0 ... 50.0 V 0 ... 50.0 V +9% rdg.+ 1d
tA (IN 1) 0 ... 999 ms 1 ms 6 ... 500 mA 0 ... 999 ms
tA (IN 2) 0 ... 999 ms 1 ms 2 6 ... 2 500 mA 0 ... 999 ms 4 ms 3 ms
tA (IN 5) 0 ... 40 ms 1 ms 5 6 ... 5 300 mA 0 ... 40 ms
UN = 120/230 V
ZL-PE ( ) 0 ... 999 m 300 ... 999 m (10% rdg.+30d) (5% rdg.+30d)
400/500 V1
ZL-N 1.00 9.99 1 m 1.00 9.99 (8% rdg.+3d) (3% rdg.+3d)
fN =16/50/60 Hz
0.01
0 ... 999 m
ZL-PE 0.1 500 ... 999 m UN = 120/230 V (18% rdg.+30d) (6% rdg.+50d)
1.00 9.99 1.3 ... 3.7 A AC
+ DC 1.00 9.99 fN = 50/60 Hz (10% rdg.+3d) (4% rdg.+3d)
10.0 29.9 0.5/1.25 A DC
0.0 ... 9.9 A 0.1 A 120 (108 ... 132) V
ZL-PE IK (ZL-PE ,
10 ... 999 A 1A 230 (196 ... 253) V
Value calculated from ZL-PE l
ZL-PE + DC)
1.00 ... 9.99 kA 10 A 400 (340 ... 440) V l
10.0 ... 50.0 kA 100 A 500 (450 ... 550) V ZL-PE
ZL-N
0.5 9.99 0.01 Display range only
ZL-PE (15 mA) 10.0 99.9 0.1 10.0 99.9 (10% rdg.+10d) (2% rdg.+2d)
100 999 1 100 999 (8% rdg.+2d) (1% rdg.+1d)
UN = 120/230 V
Calculated value
100 ... 999 mA 1 mA 15 mA AC f = 16/50/60
depends on UN and N Value calculated from ZL-PE (15 mA):
IK (15 mA) 0.00 ... 9.99 A 0.01 A Hz
ZL-PE: IK = UN/ZL-PE (15 mA)
10.0 ... 99.9 A 0.1 A
IK=UN/10...1000
0 ... 999 m 1 m 1.3 ... 3.7 A AC 300 ... 999 m (10% rdg.+30d) (5% rdg.+30d)
1.00 9.99 0.01 1.3 ... 3.7 A AC 1.00 ... 9.99 UN = 120/230 V (5% rdg.+3d) (3% rdg.+3d)
RE ( ) 10.0 99.9 0.1 400 mA AC 10.1 ... 99.9 UN = 400 V 1 (10% rdg.+3d) (3% rdg.+3d)
100 999 1 40 mA AC 100 ... 999 fN = 50/60 Hz (10% rdg.+3d) (3% rdg.+3d)
RE 1 k ... 9.99 k 0.01 k 4 mA AC 1.00 k ... 9.99 k (10% rdg.+3d) (3% rdg.+3d) l l
0 ... 999 m 1 m
1.3 ... 3.7 A AC 500 ... 999 m UN = 120/230 V (18% rdg.+30d) (6% rdg.+50d)
RE DC+ 1.00 9.99 0.01
0.5/1.25 A DC 1.00 9.99 fN = 50/60 Hz (10% rdg.+3d) (4% rdg.+3d)
10.0 29.9 0.1
UE 0 ... 253 V 1V Calculated value
UN = 120/230/
Ub Ub Limit LED on Reb = 100 k 0 ... 440 V 400 V 45 V 15 V 45 V 5 V Finger contact
fN = 50/60 Hz
Characteristic Values
Connections
Input PRO- KS-
Func- Measured Reso- Measuring Nominal Measuring Intrinsic
Display Range Impedance / Schuko PROFiTEST
tion quantity lution Range Values Uncertainty Uncertainty adapter INTRO
Test current 1
2-pin 3-pin
1 ... 999 k 1 k
UN = 50 V
1.00 ... 9.99 M 10 k
IN = 1 mA
10.0 ... 49.9 M 100 k
1 ... 999 k 1 k
UN = 100 V
1.00 ... 9.99 M 10 k
10.0 ... 99.9 M 100 k
IN = 1 mA k range k range
(6% rdg.+10d) (3% rdg.+10d)
RINS, RE ISO 1 ... 999 k 1 k IK = 1.5 mA 50 k ... 300 M
1.00 ... 9.99 M 10 k UN = 250 V
RINS 10.0 ... 99.9 M 100 k IN = 1 mA
M range M range l l
(6% rdg.+1d) (3% rdg.+1d)
100 ... 200 M 1 M
1 ... 999 k 1 k
UN = 500 V
1.00 ... 9.99 M 10 k
UN = 1000 V
10.0 ... 99.9 M 100 k
IN = 1 mA
100 ... 500 M 1 M
10 ... 999 V 1V (1.5% rdg. + 1
U 10 ... 1.19 kV (3% rdg.+1d)
1.00 ... 1.19 kV 10 V d)
0.01 ... 9.99 10 m
Im 200 mA 0.20 ... 6.00
RLO RLO 10.0 ... 99.9 100 m
Im < 200 mA 6.01 ... 99.9
U0 = 4.5 V (5% rdg.+2d) (2% rdg.+2d) l
100 ... 199 1
1
U > 230 V with KS-PROFITEST INTRO only
2
1 / 2 IN > 300 mA and 5 IN > 500 mA and If > 300 mA only up to UN 230 V!
IN 5 300 mA where UN = 230 V only
Ambient Conditions
Accuracy 0 ... + 40 C
Operation 5 ... + 50 C
Storage 20 ... + 60 C
(without batteries)
Relative humidity Max. 75% (max. 85% during storage/
transport) no condensation allowed
Elevation Max. 2000 m
Calibration interval 1 year (recommended)
Loop Resistance Measurement with Suppression of RCD Tripping Editing of Selection Lists
The test instruments make it possible to measure loop impedance
in TN systems with type A, F and AC RCCBs (10, 30, 100,
300, 500 mA nominal residual current).
The respective test I /mA
F
instrument gener-
ates a DC residual
current to this end,
which saturates the
RCCBs magnetic
circuit. t
t1 t2 t3
The test instrument
then superimposes Measuring
a measuring current Operation
which only demon-
strates half-waves RCD Disabled!
Report Generation
of like polarity. The Start
RCCB is no longer
capable of detecting this measuring current, and is consequently
not tripped during measurement.
With Angled
Barrel Plug
Barcode and label printer for USB connection to a PC Z721D PRO-Schuko Measuring
Barcode/label printer for connection to Adapter (Z503K)
a PC for self-adhesive, smudge-proof Single-phase measuring
barcode labels for identifying devices adapter for the
and system components. Devices and PROFITEST INTRO, earth-
system components can be logged by ing contact plugs to three
our test instruments, and acquired mea- 4 mm touch-guarded
sured values can be allocated to them safety plugs (black, blue,
with the scanner. yellow-green), 230 V AC,
300 V CAT III, 16 A
PRO-PE Clip Flat Test Clip for Busbars (Z503G) VARIO Plug Adapter Set
Three self-retaining test
probes with touch protec-
tion for the connection of
measurement cables with
4 mm banana plugs, or
with touch protected plugs
for sockets with an open-
ing of 3.5 mm to 12 mm,
e.g. CEE, Perilex sockets
etc. For example, the test
Floor Probe probes also fit the square PE jacks on Perilex sockets. Maximum
The 1081 floor probe allowable operating voltage: 600 V per IEC 61010.
makes it possible to mea-
sure the resistance of insu- ISO Calibrator 1
lating floors in accordance Calibration adapter for rapid, effi-
with DIN VDE 0100-600, cient testing of the accuracy of
and EN 1081. measuring instruments for insula-
tion resistance and low-value
resistors
TR25 Reel
METRISO-PROFITEST
PC Evaluation Software
http://www.gossenmetrawatt.com
( Products Electrical Testing Testing of Electr. Installations
PROFITEST MASTER)
Or
http://www.gossenmetrawatt.com
( Products Software Software for Testers)
D
Data sheet available
Prepared in Germany Subject to change without notice PDF version available on the Internet
Phone: +49-911-8602-111
GMC-I Messtechnik GmbH Fax: +49 911 8602-777
Sdwestpark 15 e-mail info@gossenmetrawatt.com
D-90449 Nrnberg, Germany www.gossenmetrawatt.com