Contactor Monitoring
P OW ER IN
X28
1
Overload signal X25 Y35 A1 A2
Door open contactor 2 output
Downstream contactor
Operate/Overhaul X24 Y34 A1 A2
Upstream contactor
Main contactor
Upper limit signal X22 Y32 A1 A2
Down overhaul Upstream contactor output
X21 Y31 A1 A2
Uplink overhaul Main contactor output
X15 COM2
5th floor leveling signal input Y31-Y35 Common
Y23
PROGRAM & MEMORY
X14
Buzzer output
OK
4th floor leveling signal input X13 Y22
3rd floor leveling signal input Downstream arrow indicator output
X12 Y21
1
Upstream arrow indicator output
-
2nd floor leveling signal input
+
X11 Y15
RESET
X07 Y14
Door open button signal input Decimal code 4th floor/BCD code D display output
2
X06 Y13
Door open button signal input Decimal code 3rd floor/BCD code C display output
1
X05 Y12
5th floor button signal input Decimal code 2nd floor/BCD code B display output
X04 Y11
4th floor button signal input Decimal code 1st floor/BCD code A display output
B
X02 Y04
2nd floor button signal input 4th floor button indicator output
I NPUT
X01 Y03
1st floor button signal input 3rd floor button indicator output
OU T P U T
COM0 Y02 2nd floor button indicator output
Y01
A
1st floor button indicator output
COM1 Y01-Y23 Common
System display
A N T E L E C T R ON I C
GLC-400
X29
X28
X27 AC2
1.2 GLC-400 Main Controller FigureButton Function And Interface Introduction
2
Safety circuit
AC1
Downstream contactor
X26
1
Overload signal Power supply terminal
X25 Y35
Operate /O verhaul
A1 A2
Door open contactor2 output
Upstream contactor
X24 Y34 Door open contactor1 output
A1 A2
Lower limit signal X23 Y33
Main contactor
Upper limit signal X22 Y32 A1 A2
Down overhaul Upstream contactor output
X21 Y31 A1 A2
Main contactor output
Uplink overhaul X15 COM2 Y31- Y35 Common
Y23
PROGRAM & MEMORY
X14
OK
Buzzer output
X13 Y22
Downstream arrow indicator output
X12 Y21 Upstream arrow indicator output
2
-
Basement reset signal input
+
X11 Y15
RESET
X07 Y14
Decimal code 4th floor display output
Door open button 2 signal input X06 Y13 Decimal code 3rd floor/BCD code C display output
Door open button 1signal input X05 Y12 Decimal code 2nd floor/BCD code B display output
5th floor button signal input X04 Y11
Decimal code 1st floor/BCD code A display output
4th floor button signal input X03 Y05 5th floor button indicator output
B
3rd floor button signal input X02 Y04 4th floor button indicator output
INPUT
X01 Y03 3rd floor button indicator output
1st floor button signal input
OU T P U T
COM0 Y02 2nd floor button indicator output
Y01
A
1st floor button indicator output
COM1
Y01-Y23 Common
Syetem display
3
GLC Series Microprocessor Based Service Lift Controller Users Manual
2.2 Output signal terminals introduction
Y02 2nd floor selection button light signal output Normally open contact
Y03 3rd floor selection button light signal output Normally open contact
Y04 4th floor selection button light signal output Normally open contact
Y05 5th floor selection button light signal output Normally open contact
Decimal code display code output1
Y11 BCD code display code outputA
Normally open contact
Y12 Decimal code display code output2 Normally open contact
BCD code display code outputB
Y13 Decimal code display code output3
BCD code display code outputC Normally open contact
Y14 Decimal code display code output4 Normally open contact
Y15 Decimal code display code output5 Normally open contact
Y21 Uplink indicator signal output Normally open contact
Y22 Downstream indicator signal output Normally open contact
Y23 Buzzer control signal output Normally open contact
COM2 Y31Y35 output common terminal
Y31 Main contactor control signal output Normally open contact
Y32 Uplink contactor control signal output Normally open contact
4
GLC Series Microprocessor Based Service Lift controller Users Manual
3 Main controller function feature
3.1 Overhaul function
Refer to overhaul Priority which defined in Gb7588any overhaul switch on the top of car and PC room,
when located at overhaul point lift is in overhaul state.
A In overhual statepress updown buttonlift for jog operationrelease
buttonstop immediatly.
5
GLC Series Microprocessor Based Service Lift Controller Users Manual
B Overload signal only effective when elevator stopped, the elevator once in operating
status, system will not respond to overload signal until the next stopping, if overload signal has
been effective before entering overload condition.
6
GLC Series Microprocessor Based Service Lift Controller User's Manual
7
GLC Series Microprocessor Based Service Lift Controller Users Manual
6.1 Menu parameter functionsetting introduction
- Page downminus1
6. 2 System display code selectiondecimal codeB C D code
System power-up, elevator is in overhaul mode, press the "A" key to enter the
display coding options, the system four LED digital display "A" which is a decimal code,
"b" that is,BCD code, each press cycles in two menus flashing display, 5 seconds no
Corresponding operation, the system will automatically recognize and output encoding
options currently displayed.
6. 3 System jumping protection time option
System power-up, elevator is in overhaul mode, press the "B" key to enter jumping
protection time selection, system four LED digital tube to 00 ~ 20 ~ 36 ~ 45 ~ 60 ~ 75
seconds numerical circulation flashing alternately shows every click, numerical values
d own a jump,5 seconds without the corresponding operation, the system will
automatically remember the currently displayed digital value.(LED digital display of
numbers that is the desired time, in seconds, 00 is cancellation of jumping time protection. )
No action within
5 seconds
*RemarksModify other parameter values in the same way, finish modifying, press [RESET] key to exit debug state was only after the data is recorded.
8
GLC Series Microprocessor Based Service Lift Controller User's Manual
7 Menu structureparameter setting instruction
03 - Model:GLC-300
production model selection 03
04 - Model:GLC-400
System operate
00 - cancel limitation of cumulative time
Cumulative time 00
(01~24)- 1-24 months
setting
System operate 00 - keep current cumulative time
cumulative time 00
01 - Reset cumulative time
reset
00 - cancel contactor detecting
Contactor monitor signal
input control terminal setting
01 - Contactor normal close terminal detecting 01
02 - Contactor normal open terminal detecting
Door open signal2 time setting (03~15)- Time of door open 2 keeps 10
3-15 seconds(300/400)
9
GLC Series Microprocessor Based Service Lift Controller Users Manual
Alternate 00
Alternate 00
Alternate 00
Alternate 00
10
T
S
R
202 301
202
R
N
1st floor button light 1st floor storey-selection button
0V +24V
201
Name
Design
( inside 24V
2nd floor button light
2nd floor storey-selection button
203
3rd floor button light 3rd floor storey-selection button
204
R1
205
2
T1 5
3
1
206
R2
5
101
Main contactor
UP
2nd floor door-opening button 1
11
Downstream arrow 5th floor leveling switch
DN 2nd floor door-opening button 2
5
3
1
T2 5
3
1
207
Buzzer Overhaul uplink button
COM1 Y01 Y02 Y03 Y04 Y05 Y11 Y12 Y13 Y14 Y15 Y21 Y22 Y23 COM2 31
3rd floor door-opening button 2
V
A2
24V Switch Power Supply
A1
Upstream contactor
Car top emergency stop PC room emergency stop Phase-sequence protection Upper limit position Upper limit position 1st floor door lock
Door-open contactor 1
N floor door lock
A1 A2
Safety circuit relay
3
~
202
101
COM0 X01 X02 X03 X04 X05 X06 X07 X11 X12 X13 X14 X15 X21 X22 X23 X24 X25 X26 X27 X28 X29
102
Down contactor
201
(202)
Motor / traction machine
GLC Series Microprocessor Based Service Lift Controller Users Manual
GLC Series Microprocessor Based Service Lift Controller Users Manual
8.2 GLC-400 Control Cabinet Typical Application
Main contactor Upstream contactor
R R1 1 2 R2 1 2 U
S S1 S2 V YD
3 4 3 4
~
T T1 5 6 T2 5 6 W 3
5 6
102
R 101
N 101 201
0V N
Single- phase air switch 24V switch power supply 202
102 L
24V
Name GLC-400 service lift control cabinet circuit diagram V1.5 208
13 14
1st floor emergency stop N floor emergency stop
Design NINGBO ANT ELECTRONIC CO.,LTD
Safety circuit relay
Door-opening relay 2
Door-opening relay 1
Overhaul/operate switch
Overload switch
Basement reset switch
Main contactor
Safety circuit relay
Up contactor
Down contactor
COM0 X01 X02 X03 X04 X05 X06 X07 X11 X12 X13 X14 X15 X21 X22 X23 X24 X25 X26 X27 X28 X29
0 V + 2 4V
(inside 24V GLC-400 Main Controller
Power supply input
COM1 Y01 Y02 Y03 Y04 Y05 Y11 Y12 Y13 Y14 Y15 Y21 Y22 Y23 COM2 Y31 Y32 Y33 Y34 Y35 AC1 AC2
Up contactor
4th floor display
2nd floor display
Downstreamarrow
Upstream arrow
Down contactor
Door-opening contactor 2
Buzzer
Down contactor
Main contactor
Up contactor
A1 A2
A1 A2
A1 A2
A1 A2
A2
BELL
UP
DN
1
A1
0V
Door interlockrelay
201
102
102
101
101
12
GLC Series Microprocessor Based Service Lift Controller Users Manual
13
GLC Series Microprocessor Based Service Lift Controller Users Manual
14