Flow Rates
Minimum: 50.00 MMSCFD
Normal: 148.50 MMSCFD
Maximum: 162.00 MMSCFD
Full Scale: 162.00 MMSCFD
CALCULATED DATA (Calculation Performed at Normal Conditions. )
DP at Min Flow: 7.657 inH2O@68F Flow Coefficient: 0.5835
DP at Normal Flow: 67.545 inH2O@68F
DP at Max Flow: 80.384 inH2O@68F Rod Reynolds Number (Minimum): 418257
DP at Full Scale Flow: 80.384 inH2O@68F Rod Reynolds Number (Normal): 1242224
Resonant Frequency: 279 Hz Gas Expansion Factor: 0.9995
Wake Frequency: 153 Hz Permanent Pressure Loss:
Blockage: 0.12 at Normal Flow: 8.02 inH2O@68F
at Maximum Flow: 9.54 inH2O@68F
Velocity at Max Flow: 73.84 ft/sec
GUIDELINES
Primary Element Min Limit: 5.72 MMSCFD Recommended Min Rod Reynolds Number: 12500
Structural Limit (Flow): 390.49 MMSCFD Recommended Min DP: 0.100 inH2O@68F
Structural Limit (DP): 467.0 inH2O@68F
Max. Allow. Pressure@Temp.: 14251.5 kPa-g 55 C Max. Allow. Temp.: 260 C
Design Pressure/Temperature: 9860.00 kPa-g 55.00 C
WARNINGS
NOTES
This report is provided according to the terms and conditions of the Instrument Toolkit(TM) End-Use Customer License Agreement.
Version: 3.0 (Build203A) Calculation by RDB. Printed On: 11-Apr-2017