Sika AnchorFix-2
ANCHORING ADHESIVE FOR MEDIUM TO HIGH LOADS
1/4
PRODUCT INFORMATION
Packaging 300 ml standard cartridge 12 cartridges per box
TECHNICAL INFORMATION
Compressive Strength 7 days (+20 C) ~68 N/mm2 (ASTM D 695)
Service Temperature Long term -40 C min. / +50 C max. (ETAG 001, Part 5)
Short term (12 hours) +80 C
APPLICATION INFORMATION
Mixing ratio Component A : component B = 10 : 1 by volume
Layer Thickness ~5 mm max.
Sag Flow Non-sag, even overhead
Product Temperature Sika AnchorFix-2 must be at a temperature of between +5 C and +20 C
for application.
Ambient Air Temperature -5 C min. / +35 C max.
Dew Point Beware of condensation.
Substrate temperature during application must be at least 3 C above dew
point.
Substrate Temperature 5 C min. / +35 C max.
Curing time Temperature Open time - Tgel Curing time - Tcur
+20 C +35 C 1 min 40 min
+10 C +20 C 4 min 70 min
+5 C +10 C 8 min 100 min
0 C +5 C * 180 min
5 C 0 C * 24 h
* Minimum cartridge temperature: +5 C
2/4
APPLICATION METHOD / TOOLS
APPLICATION INSTRUCTIONS
Anchors in solid masonry/concrete:
SUBSTRATE QUALITY Drilling of hole with an
electric drill to the dia-
Mortar and concrete must be older than 28 days. Sub-
meter and depth re-
strate strength (concrete, masonry, natural stone)
quired. Drill hole diamet-
must be verified. Pull-out tests must be carried out if
er must be in accordance
the substrate strength is unknown. The anchor hole
with anchor size.
must always be clean, dry, free from oil and grease
etc. Loose particles must be removed from the holes. The drill hole must be
Threaded rods and rebars have to be cleaned thor- cleaned with a blow
oughly from any oil, grease or any other substances pump or by compressed
and particles such as dirt etc. air, starting from the bot-
tom of the hole. (at least
MIXING 2)
Getting the cartridge ready: 300 mL Important: use oil-free
compressors.
1. Unscrew the cap
The drill hole must be
thoroughly cleaned with
the special steel brush
(brush at least 2). The
diameter of the brush
must be larger than the
diameter of the drill hole.
The drill hole must be
cleaned with a blow
2. Cut the film pump or by compressed
air, starting from the bot-
tom of the hole (at least
2).
Important: use oil-free
compressors.
The drill hole must be
thoroughly cleaned with
the special steel brush
(brush at least 2). The
3. Screw on the static diameter of the brush
mixer must be larger than the
diameter of the drill hole.
The drill hole must be
cleaned with a blow
pump or by compressed
air, starting from the bot-
tom of the hole (at least
2).
4. Place the cartridge in- Important: use oil-free
to the gun and start ap- compressors.
plication
3/4
Pump approx. twice until BASIS OF PRODUCT DATA
both parts come out uni-
formly. Do not use this All technical data stated in this Data Sheet are based
material. Release the gun on laboratory tests. Actual measured data may vary
pressure and clean the due to circumstances beyond our control.
cartridge opening with a
cloth. LOCAL RESTRICTIONS
Inject the adhesive into
the hole, starting from Please note that as a result of specific local regula-
the bottom, while slowly tions the declared data and recommended uses for
drawing back the static this product may vary from country to country. Please
mixer.In any case avoid consult the local Product Data Sheet for the exact
entrapping air. For deep product data and uses.
holes extension tubing
can be used. ECOLOGY, HEALTH AND SAFETY
For information and advice on the safe handling, stor-
Insert the anchor with a age and disposal of chemical products, users shall refer
rotary motion into the to the most recent Safety Data Sheet (SDS) containing
filled drill hole. Some ad- physical, ecological, toxicological and other safety-re-
hesive must come out of lated data.
the hole.
Important: the anchor LEGAL NOTES
must be placed within the
open time. The information, and, in particular, the recommenda-
During the resin harden- tions relating to the application and end-use of Sika
ing time the anchor must products, are given in good faith based on Sika's cur-
not be moved or loaded. rent knowledge and experience of the products when
Wash tools immediately properly stored, handled and applied under normal
with Sika Colma Cleaner. conditions in accordance with Sika's recommenda-
Wash hands and skin tions. In practice, the differences in materials, sub-
thoroughly with warm strates and actual site conditions are such that no war-
soap water. ranty in respect of merchantability or of fitness for a
particular purpose, nor any liability arising out of any
legal relationship whatsoever, can be inferred either
CLEANING OF TOOLS from this information, or from any written recom-
Clean all tools and application equipment with Sika mendations, or from any other advice offered. The
Colma Cleaner immediately after use. Hardened / user of the product must test the products suitability
cured material can only be mechanically removed. for the intended application and purpose. Sika re-
serves the right to change the properties of its
products. The proprietary rights of third parties must
FURTHER DOCUMENTS be observed. All orders are accepted subject to our
For specific information on design refer to the separ- current terms of sale and delivery. Users must always
ate documentation provided: refer to the most recent issue of the local Product Data
Technical Documentation Sika AnchorFix-2 870 43 02 Sheet for the product concerned, copies of which will
be supplied on request.
SikaAnchorFix-2_en_ID_(01-2017)_1_1.pdf
4/4