Table 4 presents the performance of the Animal Stunner in terms of

Voltage Output.
Table 4

Determine the Performance of the Developed Electronic Controlled Animal


Stunner on different Control Setting in terms of Voltage Output

Measured Output Voltage


Control Setting
Trial 1 Trial 2 Trial 3 Trial 4 Trial 5 Average
Minimum Setting 0V 0V 0V 0V 0V 0V
Medium Setting 25V 27.5V 26.5V 26V 25V 25.9V
Maximum Setting 68.8V 68.5V 69V 70V 69.7V 69.2V

The table shows the performance of the device in terms of voltage output.
During the first trial, the control setting is set to the minimum setting and the
result is 0V because there is no current flowing into it. In medium setting the
average output voltage result is 25.9V. But when the device is set to its maximum
setting, the average output voltage almost reaches 70V which happens to be its
maximum output.

Table 5
Determine the Performance of the Developed Electronic Controlled Animal
Stunner on different Control Setting of in terms of Current Output

Measured Current Voltage


Control Setting
Trial 1 Trial 2 Trial 3 Trial 4 Trial 5 Average
Minimum Setting 0A 0A 0A 0A 0A 0A
Medium Setting 1.39A 1.41A 1.43A 1.5A 1.49A 1.44A
Maximum Setting 2.87A 2.76A 2.89A 3.0A 2.97A 2.9A
The table shows the performance of the device in terms of current output.
During the first trial, the control setting is set to the minimum setting and the
result is 0V because there is no current flowing into it. In medium setting the
average output voltage result is 1.44A. But when the device is set to its maximum
setting, the average output current almost reaches 2.9A.
Table 6 presents the performance of the Animal Stunner in terms of its
Response time.

Table 6
Determine the Performance of the Developed Electronic Controlled Animal
Stunner on different Control Setting of in terms of Response Time

Control Measured Response Time


Setting Trial 1 Trial 2 Trial 3 Trial 4 Trial 5 Average
Minimum No No No No No No
Setting response response response response response response
Medium 3.0 min 3.6 min 3.84 min 2.75 min 3.0 min 3.24 min
Setting
Maximum 1.38 min 1.35 min 1.41 min 1.5 min 1.46 min 1.42 min
Setting

The table shows the response time of the device in different control
setting. When it is set to minimum setting, all the trials show no response
because there is no current flowing into it. In medium setting the average
response time result is 3 minutes and 24 seconds. But when the device is set to
its maximum setting, the average response time result is 1 minute and 42
seconds.

Table 7 presents on the level of acceptability in terms of functionality,


design, usefulness, and safety and maintenance.