Sie sind auf Seite 1von 6

Creating Clean Air

A Product Guide

Taking small steps together, always ahead, towards a better world


Creating Clean Air
A Product Guide

From coarse dust filters through to the latest laminar flow


operating theatre ceilings, our range of air filtration solutions has
been designed specifically to meet the exact requirements of our
customers, no matter what the field of application or the operating
environment.
The information contained in this brochure provides an introduction to our range and should help you
to make an initial selection. For further information, please consult the relevant product information
leaflet or contact us, and one of our dedicated team will be glad to offer you guidance. You will find
contact details for each country on the back page of this leaflet and full product information can be
found on our website - www.vokesair.com.

Filter Pads, Rolls & Mats Panel Filters Macrofalt & Macropac
High quality media for a variety of applications Pleated & glass panel filters for diverse usage Pleated filter for coarse & fine dust

Coarse dust filter for installation in air-conditioning For use in air conditioning systems or as a prefilter For use in air conditioning systems or as a prefilter
and other systems and as a prefilter for downstream where space is limited. where space is limited.
fine-dust filters.
u High performance u Maintenance free
u Filter media of synthetic, natural or u Suitable for critical applications u Large filter area
u Maintenance free u No dust breakthrough
glass fibers
u Compact design u Fully incinerable
u Fire retardant as per DIN 53438 or not
u Free of metals
burnable as per DIN 4102 respectively Dimensions (mm) Various
u Available in reel form or cut to size Temperature Resistance Up to 80C Dimensions (mm) Various
Plastic, Card or Galvanised Temperature Resistance Up to 80C
Frame Material
Dimensions (mm) Available on rolls or cut to size Steel
Frame Material Plastic
Temperature Resistance 70C Filter Class EN779 G3 F6
Filter Class EN779 G4 F5
Frame Material N/A
Filter Class EN779 G2 G4

1 | www.vokesair.com
Synthetic Pocket Glass Pocket Micratex FP-P
A range of filters for a variety of applications For high air purity & long service life Fine dust filter

Fresh or recirculation air filter in general ventilation Fresh or recirculation air filter in general ventilation Compact design filter for removal of fine-dust in air-
and air-conditioning systems. Prefilter for and air-conditioning systems. Prefilter for conditioning installations or as a prefilter.
downstream HEPA filters. downstream HEPA filters.
u Glass fibre paper - no fibre loss or
u Reduced energy consumption u Micro fine glass fibres shedding
u Extended maintenance intervals u Clean air side covering layers u Long service life
u Fully incinerable u Sealed stitches u Self-supporting and rigid
u High dust holding capacity u Long service life - high bursting pressure
Nanofyne
u Excellent life cycle cost profile u High dust holding capacity
t e c h n o l o g y

u Plastic cavity profile frame - fully incinerable


u Low energy and disposal costs u Also available in high temperature version
Dimensions (mm) Various
Temperature Resistance Up to 80C Dimensions (mm) Various 287 x 592 402 x 592
Dimensions (mm)
Frame Material Plastic or Metal Temperature Resistance Up to 100C 490 x 592 592 x 592
Filter Class EN779 G4 F8 Frame Material Plastic or Galvanised Steel Temperature Resistance 65C (120C for HT)
Filter Class EN779 F5 F8 Frame Material Plastic or Galvanised Steel
Filter Class EN779/EN1822 F6 E12

Compatex FP Micratex V Compatex TMP-TMPC


The superior solution Changeable filter system For gas turbine final filtration

Fresh, recirculation or final filter in general ventilation, Recirculate or final air filter in ventilation and air- Final filtration for gas turbines, compressors and other
in air-conditioning systems and in industry. Prefilter for conditioning systems. Prefilter for downstream HEPA rotating equipment.
downstream HEPA filters. filters. Suitable for duct installation.
u Robust frame - high burst resistance
u Glass fibre paper no fibre loss u Simple filter change - no special u Fully incinerable
u Fully incinerable tools required u Glass fibre paper medium
u Low pressure drop u Lightweight filter cell - no fibre loss or shedding
u Self-supporting and rigid u Micro fibre construction u Fully sealed for offshore, high
u High bursting pressure, u Incinerable - Metal and silicon free humidity and coastal applications
dust migration impossible u Low life cycle cost u Extended life characteristics
u Also available in high temperature version
Dimensions (mm) 287 x 592 592 x 592 Dimensions (mm) 287 x 592 592 x 592
Temperature Resistance 80C Temperature Resistance 70C
287 x 592 402 x 592
Dimensions (mm) Frame Material Plastic
490 x 592 592 x 592 Frame Material Plastic
Temperature Resistance 75C (120C for HT) Filter Class EN779 F6, F7, F9 Filter Class EN779/EN1822 F6 E12
Frame Material Plastic or Galvanised Steel
Filter Class EN779/EN1822 F6 H13

Hepatex N Hepatex DP Hepatex CR


High performance in a compact design High performance deep pleat filters Laminar flow hepa panel filters

Final filter for inlet or exhaust air systems in nuclear Final filter in cleanrooms, air outlets or systems and Final filter in cleanrooms, air outlets or systems. For
technology, medical technology and industry. supply, recirculation and exhaust air filtration, where cleanrooms up to Class 1 according to ISO 14644.
Suitable for duct installation. the highest demands are placed on air purity.
u Optimised velocity distribution
u Large filter area long service life u Deep pleated media u Guaranteed leak-free
u Low Pressure Drop u Available in a variety of frame u Various frame types and sizes
u 100% leak tested and materials u Integrated one-piece round or gel
guaranteed leak-free u Low Pressure Drop gasket. Knife edge execution also
u Rigid metal frame u Robust pleating technology available
u Compact space saving u Guaranteed leak-free u Low Pressure Drop - reduced energy consumption
design - lower housing cost
Dimensions (mm) Various Dimensions (mm) Various
205 x 610 305 x 610 Temperature Resistance Up to 120C Temperature Resistance Up to 70C
Dimensions (mm)
610 x 610 610 x 762 Stainless Steel, Wood Galvanised Steel, Stainless
Frame Material Frame Material
Temperature Resistance 125 or 220C or Galvanised Steel Steel, Aluminium or Wood
Galvanised Steel, Stainless Filter Class EN1822 E10 H13 Filter Class EN1822 H13 U17
Frame Material
Steel or Wood
Filter Class EN779/EN1822 F7 U15
Carbotex AFP Also Available
Gas adsorption filters

Fresh or recirculation air filter for ventilation and


air-conditioning systems. For adsorption of various
Filter Frames
Vokes Air produce a wide array of filter frames
odours, vapours and air-pollutants, as well as process
to ensure that you obtain the maximum
gases.
performance from our filters.
u Activated carbon composite
material
u Self-supporting and rigid
Filter Housings
Robust filter housings produced to exacting
u Both incinerable or non-flammable
quality standards to ensure the protection of
frames available
your application.
u AFP-AZ-Duo features particle
filtration and odour removal in one stage
ScandVane
287 x 592 402 x 592
Dimensions (mm)
490 x 592 592 x 592
ScandVane is a heavy duty, high efficiency
Temperature Resistance 50C weather louvre featuring a low operating pressure
Frame Material Plastic drop and high water handling capability.
Filter Class EN779 F7 for AFP-AZ-Duo

NSC Housing
NSC safe change housings are gas tight, rigid
casings for HEPA and activated carbon filters. They
Carbotex S2600 allow the contamination-free replacement of the
Refillable cartridge carbon filter system
filter using a change bag.
For adsorption of various low-concentration odours,
vapours and air pollutants.
Filtrasept
u Refillable cartridges Filtrasept, an EPA/HEPA filter housing for ceilings
u Standard filter frames and walls, is designed to provide air filtration and
u Metal cartridges distribution in one unit.
available in galvanised & stainless steel
u Available with standard and impregnated carbon
ScandMist
Dimensions (mm) 145 x 250 145 x 450
ScandMist is an extra heavy-duty industrial air
Temperature Resistance 50C cleaner that efficiently separates oil fumes, oil
Frame Material Galvanised or Stainless Steel mists and emulsion mists during continuous
Filter Class EN779/EN1822 N/A operation, even during extreme operating
conditions.

Operating Theatre Ceilings


As a renowned world-leader in the production
of Operating Theatre Ceilings, Vokes Air offer a
variety of solutions to hospitals across the globe.

Grease Filters
High performance from a variety of designs
JK, JG & JP
Permanent and washable filters for grease capture in The JG, JK and JP are high efficiency cylindrical
kitchens to maintain hygiene standards and reduce filters designed to act as a pre or final filter for
the risk of fire. a variety of applications, including installation
in systems and apparatuses, and purge and
u High grease collection efficiency ventilation filters for containers and reservoirs.
u Improved working
environment
u Flexible application Accessories
u Ideal where exhaust air has A huge variety of accessories are available
particularly high grease content to ensure your filter is operating at optimum
performance, including pressure measuring
Dimensions (mm) Refer to specific datasheet meters, gloves, face masks and belts, plus
Temperature Resistance Refer to specific datasheet much more. Please contact your local Vokes Air
Frame Material Refer to specific datasheet representative for further information.
Filter Class EN779/EN1822 Refer to specific datasheet
CLEAN AIR
Typical Contaminants & Applications

Group Class Typical contaminants Typical applications

G1 Leaves | Insects | Textile Fibres Low Grade Applications (e.g. for protection against insects and leaves)
G G2 Human Hair | Sand | Water Droplets Low Grade Applications (e.g. for protection against insects and leaves)
Coarse Dust
Filters G3 Beach sand | Plant spores Exhaust air from spray booths | Kitchen exhaust air filters
EN779 G4 Pollen | Fog Compact room air conditioners | Prefilter for F7 and F8 filters

F5 Spores | Sedimenting Particles | Cement Inlet filter for very low requirement rooms | Prefilter for F8 and F9 filters

F F6 Larger Bacteria & Germs | PM10 dust Inlet filter for low requirements rooms | Prefilter for F9 and H10 filters
Fine Dust F7 Soot | Lung Damaging Dust (PM 2.5) Typical final filter for air conditioned offices and other buildings (VDI 6022)
Filters
EN779 F8 PM 2.5-dust | Cement Dust (fine fraction) Recirculated air in AC plants | Prefilter for H11 and H12 filters

F9 Oil Smoke | Bacteria Prefilter for H13 and H14 filters | Prefilter for gas adsorption filters

E
E10 Germs | Tobacco Smoke Final filter for air conditioned rooms of very high standard (e.g. hospitals)

E11 Viruses on Carrier Particles | Carbon Black Final filter for cleanrooms ISO class 7 8
EPA Filters
EN 1822 E12 Oil Fumes | Sea Salt Nuclei Final filter for cleanrooms ISO class 5 6

H H13 Radioactive Particles Exhaust air filter in nuclear industry | Final filter for military shelters

HEPA Filters
EN 1822 H14 Viruses Final filter for cleanrooms ISO class 4 5

U
U15 All Air Suspended Particulate Matter Final filter for cleanrooms ISO class 3 4

U16 All Air Suspended Particulate Matter Final filter for cleanrooms ISO class 2 3
ULPA Filters
EN 1822 U17 All Air Suspended Particulate Matter Final filter for cleanrooms ISO class 1

Physisorption VOCs | Solvent Vapours | Kitchen Odours Airports | Office Buildings | Hotels | Hospitals | Improvement of IAQ
A Gas Filters Acidic Gases | SO2 | SO4 | NO2 | NOX Computer & Control Rooms | Microelectronics | Museums | Libraries
Gas Filters
Chemisorption Amines | NH3 | NH4 | NMP | HMDS Recirculated air in Microelectronics Industry

The Eurovent Certification scheme is designed to give you the


confidence that the filter you are selecting really does what you
expect.

Eurovent Certification is an independently operated scheme for the air filtration industry. Companies
applying to join must offer their F-Class filters for testing through Eurovent, an impartial and neutral
trade association. The filters are randomly selected by Eurovent and their performance is verified
according to the manufacturers EN 779:2002 claims. Only those manufacturers meeting their claims
are awarded certification.

You can now be sure that what we say has been checked by a independent body.

Eurovent certified manufacturers can be trusted.

Vokes Air is participating in the Eurovent Certification Programme


for Air Filters.

The fine filter range, according to EN 779, is certified under the


number 07.02.338 and presented in the Directory of Certified Air
Filters on the Eurovent website: www.eurovent-certification.com
our locations

STERREICH
Tel: +43 (0) 1 698 66 77 0

FRANCE
Tel: +33 (0) 1 64 07 61 25

ITALIA
Tel: +39 022 692 6321

SOUTH AFRICA
Tel: +27 (0) 114 250 470

SVERIGE
Tel: +46 (0) 325 661 600

UNITED KINGDOM
Tel: +44 (0) 1282 413 131

DANMARK
Tel: +45 364 966 00

SCHWEIZ
Tel: +41 (0) 433 992 700

NEDERLAND
Tel: +31 888 653 724

DEUTSCHLAND
Tel: +49 (0) 2339 128 00
oder +49 (0) 6181 9082 01

ESPAA
Tel: +34 937 522 718

In view of continuous research and development


we reserve the right to modify specifications and
dimensions without prior notice. For quoted standards,
the issue valid at the print date of this leaflet is relevant.
Vokes Air 2/2011 EN 1001 Taking small steps together, always ahead, towards a better world

www.vokesair.com

Das könnte Ihnen auch gefallen