03/012 Moeller Electric Corporation Moeller Electric Corporation 03/013

DIL Contactors UL / CSA / IEC / CE DIL Contactors UL / CSA / IEC / CE


Basic Devices, Modules Basic Devices, Modules
Rating data AC operation DC operation
UL/CSA max. Horsepower rating General IEC/EN 60 947 Standard Terminal Combination Notes
50/60 Hz purpose Max. 3-phase auxiliary contacts markings options
continuous motor ratings (kW)
1 phase 3 phase current AC-3 N.O. = normally open Type Price Type Price
open/ N.C. = normally closed 2
Magnetic Contactors,

Magnetic Contactors,
115 V 200 V 230 V 200 V 230 V 460 V 575 V 220 V 380 V 660 V Article No. see price list Article No. see price list
enclosed
230 V 400 V 690 V

Magnetic Starters
Magnetic Starters

HP HP HP HP HP HP HP A kW kW kW 1) N.O. N.C. Circuit diagram Coil voltages shown in (...) Coil voltages shown in (...)
For other coil voltages, For other coil voltages,
a page 03/065 a page 03/065
Basic devices 5

3-pole ½ 1 1½ 3 3 5 7½ 20/18 2.2 4 5.5 – – K – DIL00M(120V60HZ) DIL00M-G(24VDC)


060477 048587
½ 1 1½ 3 3 5 7½ 20/18 2.2 4 5.5 1 – K – DIL00M-10(120V60HZ) DIL00M-G-10(24VDC)
046643 048670
½ 1 1½ 3 3 5 7½ 20/18 2.2 4 5.5 – 1 K – DIL00M-01(120V60HZ) DIL00M-G-01(24VDC)
1
046651 048665
1 2 2 3 3 7½ 10 20/18 3 5.5 7.5 – – K – DIL00AM(120V60HZ) DIL00AM-G(24VDC)
061222 048567
1 2 2 3 3 7½ 10 20/18 3 5.5 7.5 1 – K – DIL00AM-10(120V60HZ) DIL00AM-G-10(24VDC)
046675 048650
3
1 2 2 3 3 7½ 10 20/18 3 5.5 7.5 – 1 K – DIL00AM-01(120V60HZ) DIL00AM-G-01(24VDC)
046683 048645
2 2 3 7½ 7½ 10 15 35/31 4 7.5 11 – – – K3) DIL0M(120V60HZ) DIL0M-G(24VDC)3)
061254 048597
2 3 5 7½ 10 15 20 35/31 5.5 11 15 – – – K3) DIL0AM(120V60HZ) DIL0AM-G(24VDC)3) 4
061262 048592

Accessories Page
3 5 5 10 10 20 25 55/50 7.5 15 18.5 – – – K DIL1M(120V60HZ) DIL1M-G(24VDC)
061270 048605 1Overload relay 04/004
3 5 7½ 10 15 25 30 55/50 11 18.5 22 – – – K DIL1AM(120V60HZ) DIL1AM-G(24VDC) 2Interface module or 03/059
061427 048602 suppressor module 03/053
3 7½ 10 15 20 40 40 90/81 15 22 30 – – – K DIL2M(120V60HZ) DIL2M-G(24VDC) 3Pneumatic timer module 03/057
046563 048615
4Mechanical latching module 03/057
5 10 15 20 25 50 50 90/81 18.5 30 37 – – – K DIL2AM(120V60HZ) DIL2AM-G(24VDC)
046571 048610 5Additional 4th pole 03/057
(DIL0M(-G) to DIL2AM(-G))
4-pole ½ 1 1½ 3 3 5 7½ 20/18 2.2 4 5.5 – – K – DIL00M4(120V60HZ) DIL00M4-G(24VDC) Additional auxiliary contact modules 02/010
046926 063171
Accessories 03/053
Other operating voltages 03/065
Auxiliary contact 03/066
modules
Side mounting 10 1 1 13
44
21
32
– K DILM820-XHI11-SI DILM820-XHI11-SI
208281 208281 DILM820-XHI... auxiliary contacts cannot be
14
43
22
31
combined with auxiliary contact module . ..SDILM
10 1 2) 1 2) 17
48
25
36
– K DILM820-XHI11V-SI 2) DILM820-XHI11V-SI 2)
208283 208283
18
47
26
35 Auxiliary contacts for side mounting can be
combined with auxiliary contacts for top mounting
15 1 – – K 10SDILM 10SDILM
44
13
up to a maximum of 5 contacts.
43
089080 089080
14

– 1 21
32
– K 01SDILM 01SDILM Maximum of one side-mounting auxiliary contact
31
001930 001930 module on either side.
22

1 1 13
44
21
32
– K 11SDILM 11SDILM
024626 024626 Notes:
43 31
14 22 1) Do not reverse directly
Top mounting 1 1 13 21 K K 11DILM 11DILM 2) 1 early-make contact, 1 late-break contact
017507 017507 3) Do not combine a DIL0(A)M-G with a
14 22
DILM820-XHI...

2 2 13 21 31 43 K K 22DILM 22DILM
019880 019880
14 22 32 44

3 1 13 21 33 43 K K 31DILM 31DILM
022253 022253
14 22 34 44

2 2) 2 2) 13 21 35 47 K K 22DDILM 2) 22DDILM 2)
026999 026999
14 22 36 48

1-866-595-9616
1-630-595-9515 Go to: http://www.klocknermoeller.com
03/012 Moeller Electric Corporation Moeller Electric Corporation 03/013
DIL Contactors UL / CSA / IEC / CE DIL Contactors UL / CSA / IEC / CE
Basic Devices, Modules Basic Devices, Modules
Rating data AC operation DC operation
UL/CSA max. Horsepower rating General IEC/EN 60 947 Standard Terminal Combination Notes
50/60 Hz purpose Max. 3-phase auxiliary contacts markings options
continuous motor ratings (kW)
1 phase 3 phase current AC-3 N.O. = normally open Type Price Type Price
open/ N.C. = normally closed 2
Magnetic Contactors,

Magnetic Contactors,
115 V 200 V 230 V 200 V 230 V 460 V 575 V 220 V 380 V 660 V Article No. see price list Article No. see price list
enclosed
230 V 400 V 690 V

Magnetic Starters
Magnetic Starters

HP HP HP HP HP HP HP A kW kW kW 1) N.O. N.C. Circuit diagram Coil voltages shown in (...) Coil voltages shown in (...)
For other coil voltages, For other coil voltages,
a page 03/065 a page 03/065
Basic devices 5

3-pole ½ 1 1½ 3 3 5 7½ 20/18 2.2 4 5.5 – – K – DIL00M(120V60HZ) DIL00M-G(24VDC)


060477 048587
½ 1 1½ 3 3 5 7½ 20/18 2.2 4 5.5 1 – K – DIL00M-10(120V60HZ) DIL00M-G-10(24VDC)
046643 048670
½ 1 1½ 3 3 5 7½ 20/18 2.2 4 5.5 – 1 K – DIL00M-01(120V60HZ) DIL00M-G-01(24VDC)
1
046651 048665
1 2 2 3 3 7½ 10 20/18 3 5.5 7.5 – – K – DIL00AM(120V60HZ) DIL00AM-G(24VDC)
061222 048567
1 2 2 3 3 7½ 10 20/18 3 5.5 7.5 1 – K – DIL00AM-10(120V60HZ) DIL00AM-G-10(24VDC)
046675 048650
3
1 2 2 3 3 7½ 10 20/18 3 5.5 7.5 – 1 K – DIL00AM-01(120V60HZ) DIL00AM-G-01(24VDC)
046683 048645
2 2 3 7½ 7½ 10 15 35/31 4 7.5 11 – – – K3) DIL0M(120V60HZ) DIL0M-G(24VDC)3)
061254 048597
2 3 5 7½ 10 15 20 35/31 5.5 11 15 – – – K3) DIL0AM(120V60HZ) DIL0AM-G(24VDC)3) 4
061262 048592

Accessories Page
3 5 5 10 10 20 25 55/50 7.5 15 18.5 – – – K DIL1M(120V60HZ) DIL1M-G(24VDC)
061270 048605 1Overload relay 04/004
3 5 7½ 10 15 25 30 55/50 11 18.5 22 – – – K DIL1AM(120V60HZ) DIL1AM-G(24VDC) 2Interface module or 03/059
061427 048602 suppressor module 03/053
3 7½ 10 15 20 40 40 90/81 15 22 30 – – – K DIL2M(120V60HZ) DIL2M-G(24VDC) 3Pneumatic timer module 03/057
046563 048615
4Mechanical latching module 03/057
5 10 15 20 25 50 50 90/81 18.5 30 37 – – – K DIL2AM(120V60HZ) DIL2AM-G(24VDC)
046571 048610 5Additional 4th pole 03/057
(DIL0M(-G) to DIL2AM(-G))
4-pole ½ 1 1½ 3 3 5 7½ 20/18 2.2 4 5.5 – – K – DIL00M4(120V60HZ) DIL00M4-G(24VDC) Additional auxiliary contact modules 02/010
046926 063171
Accessories 03/053
Other operating voltages 03/065
Auxiliary contact 03/066
modules
Side mounting 10 1 1 13
44
21
32
– K DILM820-XHI11-SI DILM820-XHI11-SI
208281 208281 DILM820-XHI... auxiliary contacts cannot be
14
43
22
31
combined with auxiliary contact module . ..SDILM
10 1 2) 1 2) 17
48
25
36
– K DILM820-XHI11V-SI 2) DILM820-XHI11V-SI 2)
208283 208283
18
47
26
35 Auxiliary contacts for side mounting can be
combined with auxiliary contacts for top mounting
15 1 – – K 10SDILM 10SDILM
44
13
up to a maximum of 5 contacts.
43
089080 089080
14

– 1 21
32
– K 01SDILM 01SDILM Maximum of one side-mounting auxiliary contact
31
001930 001930 module on either side.
22

1 1 13
44
21
32
– K 11SDILM 11SDILM
024626 024626 Notes:
43 31
14 22 1) Do not reverse directly
Top mounting 1 1 13 21 K K 11DILM 11DILM 2) 1 early-make contact, 1 late-break contact
017507 017507 3) Do not combine a DIL0(A)M-G with a
14 22
DILM820-XHI...

2 2 13 21 31 43 K K 22DILM 22DILM
019880 019880
14 22 32 44

3 1 13 21 33 43 K K 31DILM 31DILM
022253 022253
14 22 34 44

2 2) 2 2) 13 21 35 47 K K 22DDILM 2) 22DDILM 2)
026999 026999
14 22 36 48

1-866-595-9616
1-630-595-9515 Go to: http://www.klocknermoeller.com
03/014 Moeller Electric Corporation Moeller Electric Corporation 03/015
DIL Contactors UL / CSA / IEC / CE DIL Contactors UL / CSA / IEC / CE
Basic devices, modules with cage clamp Basic devices, modules with cage clamp
AC operation DC operation
Rating data General IEC/EN 60 947 Standard Terminal Notes
purpose Max. 3-phase auxiliary contacts markings
UL/CSA max. horsepower rating continuous motor ratings (kW)
50/60 Hz current
open/
Magnetic Contactors,

Magnetic Contactors,
1 phase 3 phase enclosed AC-3 Type Price Type Price

Magnetic Starters
Magnetic Starters

115V 200V 230V 200V 230V 460V 575V 220 V 380 V 660 V N.O. = normally open Article No. see price Article No. see price
230 V 400 V 690 V N.C. = normally closed list list

HP HP HP HP HP HP HP A kW kW kW N.O. N.C. Circuit diagram

Basic devices
½ 1 1½ 3 3 5 7½ 20/18 2,2 4 5,5 1 – A1 1 3 5 13
3) DIL00M-10-C(120V60HZ) DIL00M-G-10-C(24VDC)
231703 230169
A2 2 4 6 14

½ 1 1½ 3 3 5 7½ 20/18 2,2 4 5,5 – 1 A1 1 3 5 21 3) DIL00M-01-C(120V60HZ) DIL00M-G-01-C(24VDC)


231725 230171
A2 2 4 6 22

1 2 2 3 3 7½ 10 20/18 3 5,5 7,5 1 – A1 1 3 5 13


3) DIL00AM-10-C(120V60HZ) DIL00AM-G-10-C(24VDC)
231747 230173
A2 2 4 6 14

1 2 2 3 3 7½ 10 20/18 3 5,5 7,5 – 1 A1 1 3 5 21 3) DIL00AM-01-C(120V60HZ) DIL00AM-G-01-C(24VDC)


231770 230175
A2 2 4 6 22

Basic devices with integrated


surge suppressor
½ 1 1½ 3 3 5 7½ 20/18 2,2 4 5,5 1 – A1 1 3 5 13
3) DIL00M-10-C(120V60HZ-Z) DIL00M-G-10-C(24VDC-Z)
231999 232002
A2 2 4 6 14
Accessories Page
3) 3 Pneumatic timer module 03/057
½ 1 1½ 3 3 5 7½ 20/18 2,2 4 5,5 – 1 A1 1 3 5 21 DIL00M-01-C(120V60HZ-Z) DIL00M-G-01-C(24VDC-Z)
4 Mechanical latching module 03/057
232005 232008
A2 2 4 6 22 Accessories 03/053
3) Other operating voltages 03/068
1 2 2 3 3 7½ 10 20/18 3 5,5 7,5 1 – A1 1 3 5 13 DIL00AM-10-C(120V60HZ-Z) DIL00AM-G-10-C(24VDC-Z)
232011 232014
A2 2 4 6 14

1 2 2 3 3 7½ 10 20/18 3 5,5 7,5 – 1 A1 1 3 5 21 3) DIL00AM-01-C(120V60HZ-Z) DIL00AM-G-01-C(24VDC-Z)


232017 232020
A2 2 4 6 22

Auxiliary contact modules


4-pole 15 2 2 13 21 31 43 22DILM-C 22DILM-C
230271 230271
14 22 32 44

3 1 13 21 33 43 31DILM-C 31DILM-C
230275 230275
14 22 34 44

2 2) 2 2) 13 21 35 47 22DDILM-C 22DDILM-C
230280 230280
14 22 36 48

4-pole – 4 51 61 71 81 04DIL-C 04DIL-C


230282 230282
52 62 72 82

1 3 53 61 71 81 13DIL-C 13DIL-C
230284 230284
54 62 72 82

2 2 53 61 71 83 22DIL-C 22DIL-C
230286 230286
54 62 72 84

3 1 53 61 73 83 31DIL-C 31DIL-C
230289 230289
54 62 74 84

4 – 53 63 73 83 40DIL-C 40DIL-C
230290 230290
54 64 74 84

Notes: 1) do not reverse directly


2) 1 early-make contact, 1 late-break contact
3) double contact markings when using a ...DILM-C auxiliary contact

1-866-595-9616
1-630-595-9515 Go to: http://www.klocknermoeller.com
03/014 Moeller Electric Corporation Moeller Electric Corporation 03/015
DIL Contactors UL / CSA / IEC / CE DIL Contactors UL / CSA / IEC / CE
Basic devices, modules with cage clamp Basic devices, modules with cage clamp
AC operation DC operation
Rating data General IEC/EN 60 947 Standard Terminal Notes
purpose Max. 3-phase auxiliary contacts markings
UL/CSA max. horsepower rating continuous motor ratings (kW)
50/60 Hz current
open/
Magnetic Contactors,

Magnetic Contactors,
1 phase 3 phase enclosed AC-3 Type Price Type Price

Magnetic Starters
Magnetic Starters

115V 200V 230V 200V 230V 460V 575V 220 V 380 V 660 V N.O. = normally open Article No. see price Article No. see price
230 V 400 V 690 V N.C. = normally closed list list

HP HP HP HP HP HP HP A kW kW kW N.O. N.C. Circuit diagram

Basic devices
½ 1 1½ 3 3 5 7½ 20/18 2,2 4 5,5 1 – A1 1 3 5 13
3) DIL00M-10-C(120V60HZ) DIL00M-G-10-C(24VDC)
231703 230169
A2 2 4 6 14

½ 1 1½ 3 3 5 7½ 20/18 2,2 4 5,5 – 1 A1 1 3 5 21 3) DIL00M-01-C(120V60HZ) DIL00M-G-01-C(24VDC)


231725 230171
A2 2 4 6 22

1 2 2 3 3 7½ 10 20/18 3 5,5 7,5 1 – A1 1 3 5 13


3) DIL00AM-10-C(120V60HZ) DIL00AM-G-10-C(24VDC)
231747 230173
A2 2 4 6 14

1 2 2 3 3 7½ 10 20/18 3 5,5 7,5 – 1 A1 1 3 5 21 3) DIL00AM-01-C(120V60HZ) DIL00AM-G-01-C(24VDC)


231770 230175
A2 2 4 6 22

Basic devices with integrated


surge suppressor
½ 1 1½ 3 3 5 7½ 20/18 2,2 4 5,5 1 – A1 1 3 5 13
3) DIL00M-10-C(120V60HZ-Z) DIL00M-G-10-C(24VDC-Z)
231999 232002
A2 2 4 6 14
Accessories Page
3) 3 Pneumatic timer module 03/057
½ 1 1½ 3 3 5 7½ 20/18 2,2 4 5,5 – 1 A1 1 3 5 21 DIL00M-01-C(120V60HZ-Z) DIL00M-G-01-C(24VDC-Z)
4 Mechanical latching module 03/057
232005 232008
A2 2 4 6 22 Accessories 03/053
3) Other operating voltages 03/068
1 2 2 3 3 7½ 10 20/18 3 5,5 7,5 1 – A1 1 3 5 13 DIL00AM-10-C(120V60HZ-Z) DIL00AM-G-10-C(24VDC-Z)
232011 232014
A2 2 4 6 14

1 2 2 3 3 7½ 10 20/18 3 5,5 7,5 – 1 A1 1 3 5 21 3) DIL00AM-01-C(120V60HZ-Z) DIL00AM-G-01-C(24VDC-Z)


232017 232020
A2 2 4 6 22

Auxiliary contact modules


4-pole 15 2 2 13 21 31 43 22DILM-C 22DILM-C
230271 230271
14 22 32 44

3 1 13 21 33 43 31DILM-C 31DILM-C
230275 230275
14 22 34 44

2 2) 2 2) 13 21 35 47 22DDILM-C 22DDILM-C
230280 230280
14 22 36 48

4-pole – 4 51 61 71 81 04DIL-C 04DIL-C


230282 230282
52 62 72 82

1 3 53 61 71 81 13DIL-C 13DIL-C
230284 230284
54 62 72 82

2 2 53 61 71 83 22DIL-C 22DIL-C
230286 230286
54 62 72 84

3 1 53 61 73 83 31DIL-C 31DIL-C
230289 230289
54 62 74 84

4 – 53 63 73 83 40DIL-C 40DIL-C
230290 230290
54 64 74 84

Notes: 1) do not reverse directly


2) 1 early-make contact, 1 late-break contact
3) double contact markings when using a ...DILM-C auxiliary contact

1-866-595-9616
1-630-595-9515 Go to: http://www.klocknermoeller.com
03/016 Moeller Electric Corporation Moeller Electric Corporation 03/017
DIL Contactors UL / CSA / IEC / CE DIL Contactors UL / CSA / IEC / CE
Basic Devices, Modules Basic Devices, Modules
AC operation DC operation
Rating data Notes
UL/CSA max. Horsepower rating General IEC/EN 60 947 Standard Terminal Combination
50/60 Hz purpose Max. 3-phase auxiliary contacts markings options
continuous motor ratings (kW)
current
Magnetic Contactors,

Magnetic Contactors,
1 phase 3 phase AC-3 N.O. = normally open Type Price Type Price
open/ N.C. = normally closed 2
115 V 200 V 230 V 200 V 230 V 460 V 575 V 220 V 380 V 660 V 1000 V Article No. see price list Article No. see price list

Magnetic Starters
Magnetic Starters

enclosed
230 V 400 V 690 V
HP HP HP HP HP HP HP A kW kW kW kW N.O. N.C. Circuit diagram Coil voltages shown Coil voltages shown
in (...) in (...)
For other coil voltages, For other coil voltages,
a page 03/066 a page 03/066
Basic
devices
7½ 15 15 25 30 60 75 100/90 22 37 55 37 K DIL3M80(120V60HZ) DIL3M80(24VDC)
209691 209709

10 25 25 40 50 100 125 160/144 37 55 90 55 K DIL4M115(120V60HZ) DIL4M115(24VDC)


209750 209765
Accessories Page
1Overload relay 04/004
2Suppressor 03/053
Auxiliary Accessories 03/053
contact
modules
Auxiliary contact mounting options:
Side mounting 10 1 1 13
44
21
32
K DILM820-XHI11-SI DILM820-XHI11-SI
208281 208281
14
43
22
31 DILM820-XHI..-SI
DILM820-XHI11-SA
1 1) 1 1) 17
48
25
36
K DILM820-XHI11V-SI1) DILM820-XHI11V-SI1)
47 35
208283 208283
18 26

1 1 53
84
61
72
K DILM820-XHI11-SA DILM820-XHI11-SA
83 71
208282 208282 + DIL3, 4(A)M... +
54 62

Notes 1) 1 early-make contact, 1 late-break contact

DILM820-XHI..-SI

+ + DIL3, 4(A)M... + +

DILM820-XHI11-SA

+ DIL3,4 (A)M... + + DIL3, 4(A)M... +

DILM500-XMV

The contactors can be snap-mounted onto a 75mm


DIN rail to EN 50 023.
DC operated contactors are supplied as standard
with a varistor surge suppressor.
Up to 8 auxiliary contacts possible, but only up to 4
N.C. contacts or 4 N.O. contacts.
No auxiliary contacts can be mounted between the
mchanical interlock and the contactor

1-866-595-9616
1-630-595-9515 Go to: http://www.klocknermoeller.com
03/016 Moeller Electric Corporation Moeller Electric Corporation 03/017
DIL Contactors UL / CSA / IEC / CE DIL Contactors UL / CSA / IEC / CE
Basic Devices, Modules Basic Devices, Modules
AC operation DC operation
Rating data Notes
UL/CSA max. Horsepower rating General IEC/EN 60 947 Standard Terminal Combination
50/60 Hz purpose Max. 3-phase auxiliary contacts markings options
continuous motor ratings (kW)
current
Magnetic Contactors,

Magnetic Contactors,
1 phase 3 phase AC-3 N.O. = normally open Type Price Type Price
open/ N.C. = normally closed 2
115 V 200 V 230 V 200 V 230 V 460 V 575 V 220 V 380 V 660 V 1000 V Article No. see price list Article No. see price list

Magnetic Starters
Magnetic Starters

enclosed
230 V 400 V 690 V
HP HP HP HP HP HP HP A kW kW kW kW N.O. N.C. Circuit diagram Coil voltages shown Coil voltages shown
in (...) in (...)
For other coil voltages, For other coil voltages,
a page 03/066 a page 03/066
Basic
devices
7½ 15 15 25 30 60 75 100/90 22 37 55 37 K DIL3M80(120V60HZ) DIL3M80(24VDC)
209691 209709

10 25 25 40 50 100 125 160/144 37 55 90 55 K DIL4M115(120V60HZ) DIL4M115(24VDC)


209750 209765
Accessories Page
1Overload relay 04/004
2Suppressor 03/053
Auxiliary Accessories 03/053
contact
modules
Auxiliary contact mounting options:
Side mounting 10 1 1 13
44
21
32
K DILM820-XHI11-SI DILM820-XHI11-SI
208281 208281
14
43
22
31 DILM820-XHI..-SI
DILM820-XHI11-SA
1 1) 1 1) 17
48
25
36
K DILM820-XHI11V-SI1) DILM820-XHI11V-SI1)
47 35
208283 208283
18 26

1 1 53
84
61
72
K DILM820-XHI11-SA DILM820-XHI11-SA
83 71
208282 208282 + DIL3, 4(A)M... +
54 62

Notes 1) 1 early-make contact, 1 late-break contact

DILM820-XHI..-SI

+ + DIL3, 4(A)M... + +

DILM820-XHI11-SA

+ DIL3,4 (A)M... + + DIL3, 4(A)M... +

DILM500-XMV

The contactors can be snap-mounted onto a 75mm


DIN rail to EN 50 023.
DC operated contactors are supplied as standard
with a varistor surge suppressor.
Up to 8 auxiliary contacts possible, but only up to 4
N.C. contacts or 4 N.O. contacts.
No auxiliary contacts can be mounted between the
mchanical interlock and the contactor

1-866-595-9616
1-630-595-9515 Go to: http://www.klocknermoeller.com
03/018 Moeller Electric Corporation Moeller Electric Corporation 03/019
DIL Contactors UL / CSA / IEC / CE DIL Contactors UL / CSA / IEC / CE
Units complete with auxiliary contacts Units complete with auxiliary contacts
Rating data AC operation DC operation
UL/CSA max. Horsepower rating General purpose IEC/EN 60 947 Notes:
50/60 Hz continuous Max. 3-phase DIL3M80 to DIL4AM145:
current motor ratings (kW) 2

1 phase 3 phase open/enclosed AC-3 Type Price Type Price Accessories Page
1Overload relay 04/004
Magnetic Contactors,

Magnetic Contactors,
115 V 200 V 230 V 200 V 230 V 460 V 575 V 220 V 380 V 660 V 1000 V Article No. see price Article No. see price 2Suppressor 03/053

Magnetic Starters
Magnetic Starters

230 V 400 V 690 V list list Accessories 03/053


HP HP HP HP HP HP HP A kW kW kW kW Coil voltages shown in (...) Coil voltages shown in (...) Other operating voltages 03/068,
For other coil voltages, For other coil voltages, 03/069
a pages 03/068, 069 a pages 03/068, 069

- - - 50 60 125 150 225/ 3) 55 90 175 108 DILM185/22(RA250) 1) DILM185/22(RDC48)2)


208193 208191
1
- - - 60 75 150 200 250/ 3) 70 110 215 108 DILM225/22(RA250) 1) DILM225/22(RDC48)2)
208197 208195
- - - 75 100 200 250 350/ 3) 75 132 240 108 DILM250/22(RA250)1) DILM250/22(RDC48)2)
208201 208199
Terminal markings Coil to EN 50 005
- - - 100 125 250 300 350/ 3) 90 160 286 132 DILM300/22(RA250)1) DILM300/22(RDC48)2) Contacts to EN 50 005 + EN 50 012
208205 208203
DIL3(A)M80/85 and DIL4(A)M115/145 can be snap-mounted onto 75mm
- - - 125 150 300 400 450/ 3) 125 200 344 132 DILM400/22(RA250)1) DILM400/22(RDC48)2) DIN rail to EN 50 023
208209 208207
- - - 150 200 400 500 550/ 3) 155 250 344 132 DILM500/22(RA250)1) DILM500/22(RDC48)2) DC operated contactors DIL3M80 to DIL4AM145 and all contactors
208213 208211 DILM185 to DILM820 have an integral suppressor circuit.
When operating DILM580 to DILM820 with frequency inverter, the
suppressor circuit on the load side must be removed.
- - - 200 200 400 600 630/ 3) 185 315 560 600 DILM580/22(RA250)1) DILM580/22(RA250)1) DIL 3M80/22 to DILM820/22
208216 208216
- - - 200 250 500 600 700/ 3) 205 355 630 600 DILM650/22(RA250)1) DILM650/22(RA250)1)
208219 208219 Operating options: DILM185-820 with electronically controlled magnet
- - - 250 300 600 700 800/ 3) 240 400 720 800 DILM750/22(RA250)1) DILM750/22(RA250)1) systems
208222 208222 Conventional: L1
- - - 290 350 700 860 850/ 3) 260 450 750 800 DILM820/22(RA250)1) DILM820/22(RA250)1) A1/A2 have voltage applied, N
208225 208225 as normal.

Auxiliary contacts A11

A10
A1

A2

Right or left, internal 10 DILM820-XHI11-SI DILM820-XHI11-SI


208281 208281 A3

A4
44 32
13 21

31
Direct from the PLC:
43
14 22

A 24V output from the PLC L1


can be connected directly N
Right or left, external 10 DILM820-XHI11-SA DILM820-XHI11-SA to the A3/A4 terminals
208282 208282 A11 A1
84 72
53 61 A10 A2

83 71 A3
54 62
A4

Right or left, internal 10 DILM820-XHI11V-SI DILM820-XHI11V-SI 24 V


208283 208283 GND
48 36
17 25
From low level input
47 35 devices: L1
18 26
Low-consuption command N
devices such as printed
circuit board relays, control A11 A1

Notes: 1) 110 - 250 V AC/DC circuit devices or position A10 A2


2) 24 - 48 V DC switches can be connected
3) Consult Moeller Electric A3
directly to A10/A11. A4

Auxiliary contact modules


mounting options: Max. 8 auxiliary contacts possible
DIL M 820 XHI...(V)-SI

DILM820-XHI11V-SI with 1 early-


+ + DIL M + + make and 1 late-break contact.

No auxiliary contacts can be


DIL M 820 XHI 11-SA mounted between the mechanical
interlock and the contactor.

1-866-595-9616
1-630-595-9515 Go to: http://www.klocknermoeller.com
03/018 Moeller Electric Corporation Moeller Electric Corporation 03/019
DIL Contactors UL / CSA / IEC / CE DIL Contactors UL / CSA / IEC / CE
Units complete with auxiliary contacts Units complete with auxiliary contacts
Rating data AC operation DC operation
UL/CSA max. Horsepower rating General purpose IEC/EN 60 947 Notes:
50/60 Hz continuous Max. 3-phase DIL3M80 to DIL4AM145:
current motor ratings (kW) 2

1 phase 3 phase open/enclosed AC-3 Type Price Type Price Accessories Page
1Overload relay 04/004
Magnetic Contactors,

Magnetic Contactors,
115 V 200 V 230 V 200 V 230 V 460 V 575 V 220 V 380 V 660 V 1000 V Article No. see price Article No. see price 2Suppressor 03/053

Magnetic Starters
Magnetic Starters

230 V 400 V 690 V list list Accessories 03/053


HP HP HP HP HP HP HP A kW kW kW kW Coil voltages shown in (...) Coil voltages shown in (...) Other operating voltages 03/068,
For other coil voltages, For other coil voltages, 03/069
a pages 03/068, 069 a pages 03/068, 069

- - - 50 60 125 150 225/ 3) 55 90 175 108 DILM185/22(RA250) 1) DILM185/22(RDC48)2)


208193 208191
1
- - - 60 75 150 200 250/ 3) 70 110 215 108 DILM225/22(RA250) 1) DILM225/22(RDC48)2)
208197 208195
- - - 75 100 200 250 350/ 3) 75 132 240 108 DILM250/22(RA250)1) DILM250/22(RDC48)2)
208201 208199
Terminal markings Coil to EN 50 005
- - - 100 125 250 300 350/ 3) 90 160 286 132 DILM300/22(RA250)1) DILM300/22(RDC48)2) Contacts to EN 50 005 + EN 50 012
208205 208203
DIL3(A)M80/85 and DIL4(A)M115/145 can be snap-mounted onto 75mm
- - - 125 150 300 400 450/ 3) 125 200 344 132 DILM400/22(RA250)1) DILM400/22(RDC48)2) DIN rail to EN 50 023
208209 208207
- - - 150 200 400 500 550/ 3) 155 250 344 132 DILM500/22(RA250)1) DILM500/22(RDC48)2) DC operated contactors DIL3M80 to DIL4AM145 and all contactors
208213 208211 DILM185 to DILM820 have an integral suppressor circuit.
When operating DILM580 to DILM820 with frequency inverter, the
suppressor circuit on the load side must be removed.
- - - 200 200 400 600 630/ 3) 185 315 560 600 DILM580/22(RA250)1) DILM580/22(RA250)1) DIL 3M80/22 to DILM820/22
208216 208216
- - - 200 250 500 600 700/ 3) 205 355 630 600 DILM650/22(RA250)1) DILM650/22(RA250)1)
208219 208219 Operating options: DILM185-820 with electronically controlled magnet
- - - 250 300 600 700 800/ 3) 240 400 720 800 DILM750/22(RA250)1) DILM750/22(RA250)1) systems
208222 208222 Conventional: L1
- - - 290 350 700 860 850/ 3) 260 450 750 800 DILM820/22(RA250)1) DILM820/22(RA250)1) A1/A2 have voltage applied, N
208225 208225 as normal.

Auxiliary contacts A11

A10
A1

A2

Right or left, internal 10 DILM820-XHI11-SI DILM820-XHI11-SI


208281 208281 A3

A4
44 32
13 21

31
Direct from the PLC:
43
14 22

A 24V output from the PLC L1


can be connected directly N
Right or left, external 10 DILM820-XHI11-SA DILM820-XHI11-SA to the A3/A4 terminals
208282 208282 A11 A1
84 72
53 61 A10 A2

83 71 A3
54 62
A4

Right or left, internal 10 DILM820-XHI11V-SI DILM820-XHI11V-SI 24 V


208283 208283 GND
48 36
17 25
From low level input
47 35 devices: L1
18 26
Low-consuption command N
devices such as printed
circuit board relays, control A11 A1

Notes: 1) 110 - 250 V AC/DC circuit devices or position A10 A2


2) 24 - 48 V DC switches can be connected
3) Consult Moeller Electric A3
directly to A10/A11. A4

Auxiliary contact modules


mounting options: Max. 8 auxiliary contacts possible
DIL M 820 XHI...(V)-SI

DILM820-XHI11V-SI with 1 early-


+ + DIL M + + make and 1 late-break contact.

No auxiliary contacts can be


DIL M 820 XHI 11-SA mounted between the mechanical
interlock and the contactor.

1-866-595-9616
1-630-595-9515 Go to: http://www.klocknermoeller.com
03/020 Moeller Electric Corporation Moeller Electric Corporation 03/021
DIL Contactors UL / CSA / IEC / CE DIL Contactors UL / CSA / IEC / CE
Units complete with auxiliary contacts Units complete with auxiliary contacts
AC operation DC operation
Rating data General IEC/EN 60 947 Notes
UL/CSA max. Horsepower purpose Max. 3-phase
rating50/60Hz continuous motor ratings (kW)
current
3-phase open AC-3 Type Price Type Price
Magnetic Contactors,

Magnetic Contactors,
200V 230V 460V 575 V 220 V 380 V 660 V 1000 V Article No. see price Article No. see price

Magnetic Starters
Magnetic Starters

230 V 400 V 690 V list list

HP HP HP HP A kW kW kW kW

50 60 125 150 225 55 90 175 108 DILMC185/22(RA250)1) DILMC185/22(RDC48)2) Accessories Page


217963 229657 Accessories 03/053
60 75 150 200 250 70 110 215 108 DILMC225/22(RA250)1) DILMC225/22(RDC48)2) Other operating voltages 03/070
217966 229658
75 100 200 250 350 75 132 240 108 DILMC250/22(RA250)1) DILMC250/22(RDC48)2)
217969 229659 Terminal markings
Coil to EN 50 005
Contacts to EN 50 005 and EN 50 012
100 125 250 300 350 90 160 286 132 DILMC300/22(RA250)1) DILMC300/22(RDC48)2)
217972 229660
125 150 300 400 450 125 200 344 132 DILMC400/22(RA250)1) DILMC400/22(RDC48)2)
217975 229661
150 200 400 500 550 155 250 344 132 DILMC500/22(RA250)1) DILMC500/22(RDC48)2) Contactors DILMC185 to DILMC500 have an integral suppressor circuit.
217978 229662
A1 1 3 5 13 21 31 43

A2 2 4 6 14 22 32 44
DILMC185/22 to DILMC500/22

Auxiliary contacts Operating systems: DILMC185-500


right or left internal 10 DILM820-XHI-C11-SI DILM820-XHI-C11-SI Conventional: (+) L1
13
44
21
32 229513 229513 A1/A2 have voltage applied as normal. (–) N

14
43
22
31
a
A10 A2

A11 A1

A3

A4

right or left external 10 DILM820-XHI-C11-SA DILM820-XHI-C11-SA Direct from the PLC: (+) L1
53
84
61
72 229512 229512 A 24V output from the PLC can be (–) N
connected directly to the A3/A4
54
83
62
71
terminals. a
A10 A2

A11 A1

A3

A4

24 V
GND
(+) L1
From low level input devices: (–) N
Low level input devices such as printed circuit
board relays, control circuit devices or position switches can be a
connected directly to A10/A11. A10 A2
b
A11 A1

A3

A4

Auxiliary contact modules mounting options: a Standstill in emergency (Emergency-Off)


DILM820-XHI-C11-SI b max. capacity of conductor: 6 nF

Max. 8 auxiliary contacts possible


+ + DIL M + +
No auxiliary contacts can be mounted be-
tween the mechanical interlock and the
contactor..
DILM820-XHI-C11-SA

Notes 1) 110 – 250 V AC/DC


2) 24 – 48 V DC

1-866-595-9616
1-630-595-9515 Go to: http://www.klocknermoeller.com
03/020 Moeller Electric Corporation Moeller Electric Corporation 03/021
DIL Contactors UL / CSA / IEC / CE DIL Contactors UL / CSA / IEC / CE
Units complete with auxiliary contacts Units complete with auxiliary contacts
AC operation DC operation
Rating data General IEC/EN 60 947 Notes
UL/CSA max. Horsepower purpose Max. 3-phase
rating50/60Hz continuous motor ratings (kW)
current
3-phase open AC-3 Type Price Type Price
Magnetic Contactors,

Magnetic Contactors,
200V 230V 460V 575 V 220 V 380 V 660 V 1000 V Article No. see price Article No. see price

Magnetic Starters
Magnetic Starters

230 V 400 V 690 V list list

HP HP HP HP A kW kW kW kW

50 60 125 150 225 55 90 175 108 DILMC185/22(RA250)1) DILMC185/22(RDC48)2) Accessories Page


217963 229657 Accessories 03/053
60 75 150 200 250 70 110 215 108 DILMC225/22(RA250)1) DILMC225/22(RDC48)2) Other operating voltages 03/070
217966 229658
75 100 200 250 350 75 132 240 108 DILMC250/22(RA250)1) DILMC250/22(RDC48)2)
217969 229659 Terminal markings
Coil to EN 50 005
Contacts to EN 50 005 and EN 50 012
100 125 250 300 350 90 160 286 132 DILMC300/22(RA250)1) DILMC300/22(RDC48)2)
217972 229660
125 150 300 400 450 125 200 344 132 DILMC400/22(RA250)1) DILMC400/22(RDC48)2)
217975 229661
150 200 400 500 550 155 250 344 132 DILMC500/22(RA250)1) DILMC500/22(RDC48)2) Contactors DILMC185 to DILMC500 have an integral suppressor circuit.
217978 229662
A1 1 3 5 13 21 31 43

A2 2 4 6 14 22 32 44
DILMC185/22 to DILMC500/22

Auxiliary contacts Operating systems: DILMC185-500


right or left internal 10 DILM820-XHI-C11-SI DILM820-XHI-C11-SI Conventional: (+) L1
13
44
21
32 229513 229513 A1/A2 have voltage applied as normal. (–) N

14
43
22
31
a
A10 A2

A11 A1

A3

A4

right or left external 10 DILM820-XHI-C11-SA DILM820-XHI-C11-SA Direct from the PLC: (+) L1
53
84
61
72 229512 229512 A 24V output from the PLC can be (–) N
connected directly to the A3/A4
54
83
62
71
terminals. a
A10 A2

A11 A1

A3

A4

24 V
GND
(+) L1
From low level input devices: (–) N
Low level input devices such as printed circuit
board relays, control circuit devices or position switches can be a
connected directly to A10/A11. A10 A2
b
A11 A1

A3

A4

Auxiliary contact modules mounting options: a Standstill in emergency (Emergency-Off)


DILM820-XHI-C11-SI b max. capacity of conductor: 6 nF

Max. 8 auxiliary contacts possible


+ + DIL M + +
No auxiliary contacts can be mounted be-
tween the mechanical interlock and the
contactor..
DILM820-XHI-C11-SA

Notes 1) 110 – 250 V AC/DC


2) 24 – 48 V DC

1-866-595-9616
1-630-595-9515 Go to: http://www.klocknermoeller.com
03/022 Moeller Electric Corporation Moeller Electric Corporation 03/023
DIL Contactors UL / CSA / IEC / CE DIL Contactors UL / CSA / IEC / CE
Contactors for 3-phase capacitors Contactors for 3-phase capacitors
Circuit with quick discharge resistor Circuit without quick discharge resistor
Three-phase capacitors L1 L2 L3 Accessories required L1 L2 L3
50 – 60 Hz Type Price Type Price Notes
240V 480V 600V Article No. see price Auxiliary Quick Article No. see price
list contact discharge list
Magnetic Contactors,

Magnetic Contactors,
A1 1 3 5 21 31 module for resistor 1 3 5
A1
side mounting

Magnetic Starters
Magnetic Starters

A2 2 4 6 22 32
A2 2 4 6

22 4 32
R1 R1
R11 R11
R11 R11
C1
C1

kvar kvar kvar R11


Type Type
R11

With series resistors


Basic units
open 10 12 15 – – – DIL00MK-11(120V60HZ)
047020 Welding-safe for capacitors with
6 – – A1 1 3 5 21 31 DIL00MK-02(120V60HZ) – EWDIL A1 1 3 5 13 21 – inrush peaks up to 180 x IN
047031
A2 2 4 6 22 32 A2 2 4 6 14 22 with quick discharge resistor:

15 17 25 DIL0MK-10(120V60HZ) 2 x 01SDILM EWDIL DIL0MK-10(120V60HZ)


047042 047042
25 25 36 A1 1 3 5 13 DIL1MK-10(120V60HZ) 2 x 01SDILM EWDIL A1 1 3 5 13 DIL1MK-10(120V60HZ)
A2 2 4 6 14 047052 047052
A2 2 4 6 14
30 35 60 DIL2MK-10(120V60HZ) 2 x 01SDILM EWDIL DIL2MK-10(120V60HZ)
047062 047062

Auxiliary contact modules


General purpose continuous current = 10 A
Side mounting
1 N.O. contact – – – 13
44 10SDILM
089080
43
14

1 N.C. contact – – – 21
32 01SDILM
001930 2
31
22

without quick discharge resistor:

Accessories Page
2 Quick discharge resistor 03/057
Accessories 03/053
Application notes 03/025
Other operating voltages 03/071

1-866-595-9616
1-630-595-9515 Go to: http://www.klocknermoeller.com
03/022 Moeller Electric Corporation Moeller Electric Corporation 03/023
DIL Contactors UL / CSA / IEC / CE DIL Contactors UL / CSA / IEC / CE
Contactors for 3-phase capacitors Contactors for 3-phase capacitors
Circuit with quick discharge resistor Circuit without quick discharge resistor
Three-phase capacitors L1 L2 L3 Accessories required L1 L2 L3
50 – 60 Hz Type Price Type Price Notes
240V 480V 600V Article No. see price Auxiliary Quick Article No. see price
list contact discharge list
Magnetic Contactors,

Magnetic Contactors,
A1 1 3 5 21 31 module for resistor 1 3 5
A1
side mounting

Magnetic Starters
Magnetic Starters

A2 2 4 6 22 32
A2 2 4 6

22 4 32
R1 R1
R11 R11
R11 R11
C1
C1

kvar kvar kvar R11


Type Type
R11

With series resistors


Basic units
open 10 12 15 – – – DIL00MK-11(120V60HZ)
047020 Welding-safe for capacitors with
6 – – A1 1 3 5 21 31 DIL00MK-02(120V60HZ) – EWDIL A1 1 3 5 13 21 – inrush peaks up to 180 x IN
047031
A2 2 4 6 22 32 A2 2 4 6 14 22 with quick discharge resistor:

15 17 25 DIL0MK-10(120V60HZ) 2 x 01SDILM EWDIL DIL0MK-10(120V60HZ)


047042 047042
25 25 36 A1 1 3 5 13 DIL1MK-10(120V60HZ) 2 x 01SDILM EWDIL A1 1 3 5 13 DIL1MK-10(120V60HZ)
A2 2 4 6 14 047052 047052
A2 2 4 6 14
30 35 60 DIL2MK-10(120V60HZ) 2 x 01SDILM EWDIL DIL2MK-10(120V60HZ)
047062 047062

Auxiliary contact modules


General purpose continuous current = 10 A
Side mounting
1 N.O. contact – – – 13
44 10SDILM
089080
43
14

1 N.C. contact – – – 21
32 01SDILM
001930 2
31
22

without quick discharge resistor:

Accessories Page
2 Quick discharge resistor 03/057
Accessories 03/053
Application notes 03/025
Other operating voltages 03/071

1-866-595-9616
1-630-595-9515 Go to: http://www.klocknermoeller.com
03/024 Moeller Electric Corporation

DIL Contactors
Contactors for Three-phase capacitors

Circuit with or without quick discharge Required accessories


resistor Circuit (a)
Three-phase capacitors Type Price
50 – 60 Hz
Magnetic Contactors,

Article No. see price Quick Added


list discharge terminals
Magnetic Starters

240V 480V 600V resistor

kvar kvar kvar Circuit diagram Type Type

Without series resistors


open
– 50 75 A1 1 3 5 13 21 31 43 DIL3MK72/22(120V60HZ) EWDIL 3X
209974 ZKDILM
A2 2 4 6 14 22 32 44

1-866-595-9616
1-630-595-9515 Go to: http://www.klocknermoeller.com
Moeller Electric Corporation 03/025
DIL Contactors
Contactors for Three-phase capacitors

Application notes
DIL3MK72/22
with quick discharge resistor::

Magnetic Contactors,
L1 L2 L3 L1 L2 L3

Magnetic Starters
A1 1 3 5 21 31 A1 1 3 5

A2 2 4 6 22 32 A2 2 4 6

22 4 32
R1 R1
R11 R11 R11
R11
C1 C1

R11 R11

a) Circuit with quick discharge b) Circuit without quick discharge


resistor resistor

Accessories Page
In the case of group compensation, multi-step capacitor banks are connected to the main supply, as required. In the
process, transient currents of up to 180 x Ie can flow between the capacitors. 1 Extension terminal 06/056

Contactors with series resistors a page 03/022 2 Quick discharge resistor 06/057

The contactors are pre-charged via the early-make auxiliary contacts and the mounted wire resistors, thereby reduc- Accessories 03/053
ing the inrush current. The main contacts then close after a time lag and carry the uninterrupted current.
Due to their special contacts, capacitor contactors are weld-resistant for capacitors with inrush current Other operating voltages 03/071
peaks up to 180 x Ie.
Through the use of quick discharge resistors, the danger of a full discharge in the event of rapidly recurring closure
can be excluded. The resultant discharge times are 0,2 s. The resistor is switched by means of two auxiliary contacts
of the conmtactor.

1-866-595-9616
1-630-595-9515 Go to: http://www.klocknermoeller.com
03/026 Moeller Electric Corporation Moeller Electric Corporation 03/027
DIL Contactors UL / CSA / IEC / CE DIL Contactors UL / CSA / IEC / CE
Reversing Contactor Combinations Reversing Contactor Combinations
Rating data AC operation
UL/CSA maximum Horsepower rating (HP) IEC/EN 60 947 Individual components of the combination Notes:
50/60Hz Max. 3-phase motor ratings (kW)
50/60 Hz

3 phase AC-3 Type Price


Magnetic Contactors,

Magnetic Contactors,
Magnetic Starters
Magnetic Starters

200 V 230 V 460 V 575 V 220 V 380 V 660 V Article No. see price Contactor Contactor Spare auxiliary contacts
230 V 400 V 690 V Coil voltages shown in (...) list Mechanical
240 V 440 V For other coil voltages, interlock
a page 03/070
HP HP HP HP kW kW kW Type Type
1
Reversing
contactors
2 3 5 5 2.2 4 4 DIULEM/21/MV(120V60HZ) DILEM-10 DILEM-10 33 33 +
051846 + 11DILEM + 11DILEM Accessories Page
34 34
1 Overload relay 04/004
Accessories 03/053
3 3 7½ 10 3 5.5 – DIUL00AM/11/MV(120V60HZ) DIL00AM DIL00AM – – + Other operating voltages 03/072
110199 + 11DILM + 11DILM
7½ 7½ 10 15 4 7.5 – DIUL0M/11/MV(120V60HZ) DIL0M DIL0M – – +
110215 + 11DILM + 11DILM
7½ 10 15 20 5.5 11 – DIUL0AM/11/MV(120V60HZ) DIL0AM DIL0AM – – +
110231 + 11DILM + 11DILM
10 10 20 25 7.5 15 – DIUL1M/11/MV(120V60HZ) DIL1M DIL1M – – +
+ 11DILM + 11DILM
10 15 25 30 11 18.5 – DIUL1AM/11/MV(120V60HZ) DIL1AM DIL1AM – – +
110246 + 11DILM + 11DILM
15 20 40 40 15 22 – DIUL2M/11/MV(120V60HZ) DIL2M DIL2M – – +
+ 11DILM + 11DILM
20 25 50 50 18.5 30 – DIUL2AM/11/MV(120V60HZ) DIL2AM DIL2AM – – +
110262 + 11DILM + 11DILM
25 30 60 75 22 37 55 DIUL3M80/11/XMV(120V60HZ) DIL3M80 DIL3M80 – – +
+ DILM820-XHI11-SI + DILM820-XHI11-SI
40 50 100 125 37 55 90 DIUL4M115/11/XMV(120V60HZ) DIL4M115 DIL4M115 – – +
+ DILM820-XHI11-SI + DILM820-XHI11-SI

1-866-595-9616
1-630-595-9515 Go to: http://www.klocknermoeller.com
03/026 Moeller Electric Corporation Moeller Electric Corporation 03/027
DIL Contactors UL / CSA / IEC / CE DIL Contactors UL / CSA / IEC / CE
Reversing Contactor Combinations Reversing Contactor Combinations
Rating data AC operation
UL/CSA maximum Horsepower rating (HP) IEC/EN 60 947 Individual components of the combination Notes:
50/60Hz Max. 3-phase motor ratings (kW)
50/60 Hz

3 phase AC-3 Type Price


Magnetic Contactors,

Magnetic Contactors,
Magnetic Starters
Magnetic Starters

200 V 230 V 460 V 575 V 220 V 380 V 660 V Article No. see price Contactor Contactor Spare auxiliary contacts
230 V 400 V 690 V Coil voltages shown in (...) list Mechanical
240 V 440 V For other coil voltages, interlock
a page 03/070
HP HP HP HP kW kW kW Type Type
1
Reversing
contactors
2 3 5 5 2.2 4 4 DIULEM/21/MV(120V60HZ) DILEM-10 DILEM-10 33 33 +
051846 + 11DILEM + 11DILEM Accessories Page
34 34
1 Overload relay 04/004
Accessories 03/053
3 3 7½ 10 3 5.5 – DIUL00AM/11/MV(120V60HZ) DIL00AM DIL00AM – – + Other operating voltages 03/072
110199 + 11DILM + 11DILM
7½ 7½ 10 15 4 7.5 – DIUL0M/11/MV(120V60HZ) DIL0M DIL0M – – +
110215 + 11DILM + 11DILM
7½ 10 15 20 5.5 11 – DIUL0AM/11/MV(120V60HZ) DIL0AM DIL0AM – – +
110231 + 11DILM + 11DILM
10 10 20 25 7.5 15 – DIUL1M/11/MV(120V60HZ) DIL1M DIL1M – – +
+ 11DILM + 11DILM
10 15 25 30 11 18.5 – DIUL1AM/11/MV(120V60HZ) DIL1AM DIL1AM – – +
110246 + 11DILM + 11DILM
15 20 40 40 15 22 – DIUL2M/11/MV(120V60HZ) DIL2M DIL2M – – +
+ 11DILM + 11DILM
20 25 50 50 18.5 30 – DIUL2AM/11/MV(120V60HZ) DIL2AM DIL2AM – – +
110262 + 11DILM + 11DILM
25 30 60 75 22 37 55 DIUL3M80/11/XMV(120V60HZ) DIL3M80 DIL3M80 – – +
+ DILM820-XHI11-SI + DILM820-XHI11-SI
40 50 100 125 37 55 90 DIUL4M115/11/XMV(120V60HZ) DIL4M115 DIL4M115 – – +
+ DILM820-XHI11-SI + DILM820-XHI11-SI

1-866-595-9616
1-630-595-9515 Go to: http://www.klocknermoeller.com
03/028 Moeller Electric Corporation Moeller Electric Corporation 03/029
DIL Contactors UL / CSA / IEC / CE DIL Contactors UL / CSA / IEC / CE
For DC Loads, AC and DC operated For DC Loads, AC and DC operated
AC operation DC operation
Rating data General Standard Terminal Notes
UL/CSA purpose auxiliary contacts markings
max. DC Horsepower rating continuous
3 pole current
open/ N.O. = normally open Type Price Type Prcie 2
Magnetic Contactors,

Magnetic Contactors,
enclosed N.C. = normally closed
125 V 250 V Article No. see price list Article No. see price list

Magnetic Starters
Magnetic Starters

HP HP A N.O. N.C. Circuit diagram Coil voltages shown Coil voltages shown
in (...) in (...)
For other coil voltages, For other coil voltages,
a pages 03/066, 067 a pages 03/066, 067 5
Basic devices

1 2 20/18 a page 03/012 DIL00M(120V60HZ) DIL00M-G(24VDC)


060477 048587
1½ 3 20/18 DIL00AM(120V60HZ) DIL00AM-G(24VDC)
061222 048567 1

2 5 35/31 DIL0M(120V60HZ) DIL0M-G(24VDC)


061254 048597
3
2 5 35/31 DIL0AM(120V60HZ) DIL0AM-G(24VDC)
061262 048592

5 10 55/50 DIL1M(120V60HZ) DIL1M-G(24VDC)


061270 048605 4
5 10 55/50 DIL1AM(120V60HZ) DIL1AM-G(24VDC)
061427 048602
7½ 15 90/81 DIL2M(120V60HZ) DIL2M-G(24VDC)
046563 048615
10 20 90/81 DIL2AM(120V60HZ) DIL2AM-G(24VDC) 2
046571 048610
10 20 100/90 a page 03/016 DIL3M80(120V60HZ) DIL3M80(24VDC)
209691 209709
10 20 100/90 DIL3AM85(120V60HZ) DIL3AM85(24VDC)
209723 209737

15 30 160/144 DIL4M115(120V60HZ) DIL4M115(24VDC)


209750 209765
15 30 160/144 DIL4AM145(120V60HZ) DIL4AM145(24VDC)
209778 209792
1

Accessories Page
1Overload relay 04/004
2Interface module or 03/059
suppressor module 03/053
3Pneumatic timer module 03/057
4Mechanical latching module 03/057
5Additional 4th pole from 03/057
DIL0M(-G)
Additional auxiliary contact modules 02/010
Accessories 03/053
Other operating voltages 03/066
03/067

1-866-595-9616
1-630-595-9515 Go to: http://www.klocknermoeller.com
03/028 Moeller Electric Corporation Moeller Electric Corporation 03/029
DIL Contactors UL / CSA / IEC / CE DIL Contactors UL / CSA / IEC / CE
For DC Loads, AC and DC operated For DC Loads, AC and DC operated
AC operation DC operation
Rating data General Standard Terminal Notes
UL/CSA purpose auxiliary contacts markings
max. DC Horsepower rating continuous
3 pole current
open/ N.O. = normally open Type Price Type Prcie 2
Magnetic Contactors,

Magnetic Contactors,
enclosed N.C. = normally closed
125 V 250 V Article No. see price list Article No. see price list

Magnetic Starters
Magnetic Starters

HP HP A N.O. N.C. Circuit diagram Coil voltages shown Coil voltages shown
in (...) in (...)
For other coil voltages, For other coil voltages,
a pages 03/066, 067 a pages 03/066, 067 5
Basic devices

1 2 20/18 a page 03/012 DIL00M(120V60HZ) DIL00M-G(24VDC)


060477 048587
1½ 3 20/18 DIL00AM(120V60HZ) DIL00AM-G(24VDC)
061222 048567 1

2 5 35/31 DIL0M(120V60HZ) DIL0M-G(24VDC)


061254 048597
3
2 5 35/31 DIL0AM(120V60HZ) DIL0AM-G(24VDC)
061262 048592

5 10 55/50 DIL1M(120V60HZ) DIL1M-G(24VDC)


061270 048605 4
5 10 55/50 DIL1AM(120V60HZ) DIL1AM-G(24VDC)
061427 048602
7½ 15 90/81 DIL2M(120V60HZ) DIL2M-G(24VDC)
046563 048615
10 20 90/81 DIL2AM(120V60HZ) DIL2AM-G(24VDC) 2
046571 048610
10 20 100/90 a page 03/016 DIL3M80(120V60HZ) DIL3M80(24VDC)
209691 209709
10 20 100/90 DIL3AM85(120V60HZ) DIL3AM85(24VDC)
209723 209737

15 30 160/144 DIL4M115(120V60HZ) DIL4M115(24VDC)


209750 209765
15 30 160/144 DIL4AM145(120V60HZ) DIL4AM145(24VDC)
209778 209792
1

Accessories Page
1Overload relay 04/004
2Interface module or 03/059
suppressor module 03/053
3Pneumatic timer module 03/057
4Mechanical latching module 03/057
5Additional 4th pole from 03/057
DIL0M(-G)
Additional auxiliary contact modules 02/010
Accessories 03/053
Other operating voltages 03/066
03/067

1-866-595-9616
1-630-595-9515 Go to: http://www.klocknermoeller.com