Sie sind auf Seite 1von 10

HMM INFRA LTD,ANBALA

TITLE TRESTLES DESIGN CALCULATION


PROJECT 60 MTR SPAN OPEN WEB GIRDER
CUSTOMER L&T LUCKNOW METRO

DESIGN OF TRESTLE ( CRIBS )

Length of Span = 60 m
Weight of span = 450 MT
weight/meter for span = 7.5
Max load in segment = 45
Max Reaction per Trestles = 1.5x135 67.5 MT
No. of Trestles = 4

Maximum Vertical load coming on the column = 16.9


Horizontal force @ % 10.0 = 1.69

Column provided4x(50x50x6)

Rolled Steel Joist Angle Rsj 50X50X6(Dimension and its Properties):

50

50

400
x x

400
y
Properties of RSJ:50x50x6
Ax = 5.68
Ixx = 12.90
Iyy = 12.90
rmin = 1.51
Cxx = 1.45
Cyy = 1.45
weight = 4.50
Area of combined section = 22.72
Moment of inertia of combined section = 7819.1
rxx of combined section = 18.55
Z of combined section = 390.96

Height of column considered = 3.00


= 300
Hence λ L/rxx = 16.17
Allowable slenderness ratio = 180.00
n n 1/n
Permissible compressive stress 0.66xfcc x fy/[(fcc) +(fy) ]
fcc= p 2xE/λ2 7548.08
fy = 250 MPA n= 1.4
Hence , Permissible compressive stress = 1640.08
Capacity of the column = 37263
= 37.3
> 16.9

Max. Bending moment = 5.06


Bending stress , sbc =M/Z = 1294.90
= 1650
Axial stress , sac=P/A = 742.74
Allowable axial stress, sas = 1640.08
Hence sbc/sbs + sac/sas = 1.2377

Design of Lacing System:


### kg
371
variable from 1.0 m

371 45 0.7854
to 3.0m

371

Lacing is designed for 2.5% of total axial force


Force on lacing system = 0.42188
sectio used for lacing system = ISMC 75
Ax = 5.68
rmin for each component of angles = 1.51
L 0.7 x ( 37.1 37.1 ) = 51.94
L/rmin = 34.40

n n 1/n
Permissible compressive stress 0.66xfcc x fy/[(fcc) +(fy) ]
fcc= p 2xE/λ2 1668.32
fy = 250 MPA n= 1.4
Hence , Permissible compressive stress = 1572
Axial Compressive stress < 74.2738

DESIGN OF MAIN BEAM ( B1 )

Maximum Bending moment = 9.00

USING RSJ - 300 x 140

Properties of Rsj 300 Here L 3.50 m

D = 300 mm
T = 13.1 mm
t = 7.7 mm
d1 = 300 - 2 x 13.1 = 273.8
Zxx = 599 cm3
ry = 12.4 mm d1 = 35.6
t
Now
fcb = k1( X +K2 x Y) (C2/C1)

Here K1 =1 K2 = 0.0 C2/C1 = 1

L = 282.3 D = 22.9
ry T
Values of X & Y from cl.6.2.4(IS:800-19Table:6.5
X = 130
Y = 46
fcb = 130
AS d1/ < 85 fcb = 130 x 1.2 = 156

Hence sbc = 1650 Kg/cm2


Stress = 1503 Kg/cm2 > 1650 Kg/cm2
Ok

Max shear force = 15.6


= 15642.6
Hence shear stress = 677.2
< 1125
Ok

x ≈
NBALA
PREPARED BY PS REV 0
CHECKED BY RKS DATE ###
REF DRAWING NO.

MT
t
cm2
cm4
cm4
cm
cm
cm
kg/m
cm2
cm4
cm
cm3

m considering max height


cm

Ok

( cl.5.1.1 of IS:800-1984)

N/mm2

kg/cm2
kg
t
t Ok

t-m (Horizontal force x Ht of column)


kg/cm 2

kg/cm2 Ok
kg/cm2
kg/cm2
> 1 check

165

45

( cl.5.7.2 of IS:800-1984)
MT
ISMC 75
cm2
cm
cm Ok
< 145 ( cl.5.7.2.3 of IS:800-1984)

( cl.5.1.1 of IS:800-1984)

N/mm2

kg/cm2
kg/cm3 Ok

t-m AS PER STADD FILE

1344 = 85
fy

mm

<
t AS PER STADD FILE
kg

Kg/cm2

Das könnte Ihnen auch gefallen