1 3.

i 3.9.5
ii

2 NSR

i a)
ii b)
iii c)
iv d)

3 NSR

i a)
ii b)

1 4

4.1
4.2
4.3
4.4
4.5
4.6

2 NSR

a)
b)
c)
d)
e)
f)
3 NSR
b)
SUB-HEAD-3 (RISING MAINS & BUS TRUNKING)

Supplying, installing on wall, testing and commissioning of following capacity rising mains made of 1.6mm thick sheet ste
enclosure duly painted with powder coating, wall straps, fully insulated 4 Nos aluminium bus bars in convenient sections an
suitable for 415 volts, 3 phase, 4 wire, 50 Hz, A.C. supply with extension joints, fire proof barriers, expansion joints, thrust pa
including jointing, and earthing with 2 runs of galvanised iron strips etc. as required. (Rising mains confirming to IS 8623, TE
439) WITH end cap

630 amps (S.C. rating for 1 sec - 50 KA)


1600 amps (S.C. rating for 1 sec - 50 KA)
Supplying, installation,testing and commissioning of TAP OFF UNIT with following capacity MCCB in 1.6 mm thick CRCA she
steel enclosure I/c incoming bus trunking connection and connection to rising mains with PVC insulated copper strip with rota
handle etc as per specifications complete as required.

100 A FP MCCB, 25 kA breaking capacity with TMD with O/L,S/C,


125 A FP MCCB, 25 kA breaking capacity with TMD with O/L,S/C,
160 A FP MCCB, 25 kA breaking capacity with TMD with O/L,S/C,
1600 A FP MCCB, 50 kA breaking capacity with TMD with O/L,S/C,
Supplying, installation,testing and commissioning of end feed unit with following capacity MCCB in 1.6 mm thick CRCA she
steel enclosure I/c incoming bus trunking connection and connection to rising mains with PVC insulated copper strip with rota
handle etc as per specifications complete as required.

630 amps FP MCCB(S.C. rating for 1 sec -50 KA)with TMD with O/L,S/C,
1600 amps FP MCCB(S.C. rating for 1 sec - 50 KA)with TMD with O/L,S/C,

SUB-HEAD-4 (RISING MAINS & BUS TRUNKING, PVC TRUNKING, METAL TRUNKING)

Supplying, installing on wall, testing and commissioning of Busbar trunking Sandwitch Type, IP55, Alluminium Conducto
3P+N+E, 100% Neutral, with All neccessory Bends, Elbows, T Junction, Reducer, Mounting Support, Hangers, Tap Off Provisio
at Each Meter,

1600 amps (S.C. rating for 1 sec - 50 KA)


1250 amps (S.C. rating for 1 sec - 50 KA)
800 amps (S.C. rating for 1 sec - 50 KA)
630 amps (S.C. rating for 1 sec - 50 KA)
400 amps (S.C. rating for 1 sec - 50 KA)
250 amps (S.C. rating for 1 sec - 50 KA)
Supplying, installation,testing and commissioning of TAP OFF UNIT with Breakers in enclosure I/c incoming bus trunkin
connection and connection to rising mains with PVC insulated copper strip with rotary handle etc as per specifications comple
as required.

Tap off Unit with 63 A FP MCB, 10 kA breaking capacity


Tap off Unit with 100 A FP MCCB, 25 kA breaking capacity with TMD with O/L,S/C,
Tap off Unit with 160 A FP MCCB, 25 kA breaking capacity with TMD with O/L,S/C,
Tap off Unit with 250 A FP MCCB, 25 kA breaking capacity with TMD with O/L,S/C,
Tap off Unit with 400 A FP MCCB, 36 kA breaking capacity with TMD with O/L,S/C,
Tap off Unit with 630 A FP MCCB, 36 kA breaking capacity with TMD with O/L,S/C,
End Feed Unit for 1600A with MCCB, 50kA with Power Monitoring, Handle
1600 amps FP MCCB/ACB (S.C. rating for 1 sec - 50 KA)with Microprocessor with O/L,S/C,
Unit Unit Total Total Total
Supply Installation Supply Installation SITC

50 Metre - - -
25 Metre - - -

8 Nos. - - -
8 Nos. - - -
6 Nos. - - -
1 Nos. - - -

2 Nos. - - -
1 Nos. - - -
0 0 -

Unit Unit Total Total Total


Supply Installation Supply Installation SITC

60 Metre - - -
40 Metre - - -
120 Metre
60 Metre
60 Metre
60 Metre

6 Nos. - - -
13 Nos. - - -
2 Nos. - - -
10 Nos. - - -
3 Nos. - - -
1 Nos. - - -
1 Nos. - - -
0 0 -