Beruflich Dokumente
Kultur Dokumente
INTRODUCTION:
C-DOT-Center for Development of Telemetics
C-DOT is developd in India in 1984 by Dr.Sam Petroda,Head Quartrs at
Bangalor.
The Main Objective of C-DOT is to design and develop digital exchanges
suitable for Indian environment.
TG TG COPY 0 COPY 1 TG TG
P S R R S S P
S T T T T T T T T P S S P T T T T T T T T L S
U C C C C C C C C C C C C C C C C C C C CA U
V
0 0 0 1 1 E 1
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24E 25 26
T T
T R RM
C C
P C R S R R R R S R D DA P
R / /
S T T T T / A P S A A S P A T T S T T CS S
T R R T
U C C C C C T C C P P C C T C C / C C / EU
C M M
0 N 0 0 0 0 1 1 1 1 T TR1
F F
F C C
0 1
TG TG COPY 0 COPY 1 TG TG
C-DOT SBM:-
It is the THIRD generation of C-DOT DSS Family.
It is the DOUBLE the size of C-DOT 256 RAX and also serves Rural Areas and
Small Urban Areas.
It has a total of 2024 terminations and it contains 10 frames, Base Module (BM)
have 488 terminations and LM1 have 768 terminations and LM2 have768
terminations.
LM1 BM LM2
FIG: Single Base Module with TIC concentration.
C-DOT MBM:-
It is the FOURTH generation of C-DOT DSS Family.
C-DOT MAX is two types.
1. MAX-L (Main Automatic Exchange –Large)which supports a maximum
Of 16 BM’s.
2. MAX-XL (Main Automatic Exchange –Extra Large)which supports
A maximum of 16 BM’s.
It is controlled by Input-output processor(IOP) Module.
In MBM ,IOP’s are connected to AP.
In MBM, ADP’s are connected to AP.
TERMINAL UNIT-1
(TU-1)
TERMINAL UNIT-2
(TU-2)
TERMINAL UNIT-3
(TU-3)
TERMINAL UNIT-4
(TU-4)
BASE PROCESSOR UNIT
(BPU)
TIME SWITCH UNIT
(TSU)
FIG: BASE MODULE (BM) CONFIGURATION
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26
S S
P P
P P
T C T T T C
S T T T T T T T T T T T T T T T T S
I / U U I /
U C C C C C C C C C C C C C C C C U
C I I I C I
I I
S S
P P
FIG: ANALOG TERMINAL UNIT (ATU) CONFIGURATION
ADMINISTRATIVE MODULE:-
Aministrative module (AM) consist of Administrative processor(APC).
It Communicates with Base processors via the central message
switch
It supports the Input output module for providing man-machine
Interface.
It also supports the Alarm display panel for the audio visual
indication of faults in the system
INPUT-OUTPUT MODULE:-
Input-output module (IOM) consist of input-output processor (IOP).
Input-output processor is a general purpose computer with UNIX
Operating system.
It is used as a front end processor in C-DOT switch.
In MBM(multi base module) IOP connected to AP(administrative
processor) in CM –RACK.
In MBM alarm display panel connected to AP.
CENTRAL MODULE:-
Central module is responsible for communication between base
Module and administrative module,clock distribution and network
Synchronization for these functions,central module has a space
Switch ,space switch controller and central message switch.
CM provides connectivity to 16 BMs if it is CM-L and 32 BMs if it is
CM-XL
Each BM interfaces with CM via two 512 channel parallel buses as
BUS-0 and BUS-1 each operating at 4 mbps.
SUM BM:-
Signalling unit module(SUM) BM is used for signalling.
The calls which are going through TAX are routed through this SUM BM.
Any one of the ATU or DTU in a BM can be replaced by sum frame to support CCS7
Signalling.
VU FRAME
DIGITAL TERMINAL UNIT
(DTU)
DTU
DTU
BASE PROCESSOR UNIT
(BPU)
TIME SWITCH UNIT
(TSU)
FIG:VU BM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26
D
P D D D D D D D P
T T T T T
S T T T T T T T S
U U U U S
U S C S C S C C U
C I I C 3
I 0 0 1 1 2 2 3 I
FIG 1.1
.[;54.
S
Y
S
T
E
M
A
R
C
H
I
T
E
C
T
U
R
E