Sie sind auf Seite 1von 3

,,:.; .......

EVONIK ENERGY SERVICES INDIA PVT. LTD. 'evonlK IHOUnlll!

IDOCUMENT REVIEW STATUS REMARKS


, .

IREVIEWED WITHOUT COMMENTS A Irt~


1REVIEWED WITH COMMENTS B I ·1
REJECTED C I I
FGr\ ii'~FORMATION ONLY o1 I
0>1,'1 ~lo J~ AJ
Signature
Refere, ce I Date
,---".,--­ ..,-, n Na
r •

NOTE:
THIS DOCUMENT CONTAINS 3 SHEETS INCLUDING THIS SHEET.

I ! DEPARTMENT ! NAME I SIGNATURE DATE


r---'" I • PREPARED PCB - Perf.&Prop. I K.N SIGNED 14108110
REVISED AS PER MOM
& DATED 30.10.10 & 18.11.10
KN/A.J.B M.N 26.11.1~ CHECKED
PCB - Perf.&Prop. • A.J.B I SIGNED • 14108110
REV ZONE I PARTICUlARS BY IAWD DATE I APPROVED PCB - Perf.&Prop. : A.T.S
.. _.. I SIGNED 14108/10
ON PROCESS I I FOR APPROVAL I FOR INFORMATION I e FORPLANNING I e I FOR ERECTION
THIS DOCUMENT IS THE PROPERTY OF MIS CETHAR VESSELS LIMITED. AND IT MUST NOT BE USED
DIRECTLY OR INDIRECTLY IN ANY WAY DETRIMENTAL TO THE INTEREST OF THE COMPANY.

COASTAL THERMAL POWER PROJECT (2X300 MW)


i PROJECT CODE CTP NO OF SlIEET
MEENAKSHI ENERGY PRIVATE LIMITED
rneenakEhl8nel'gy' I UVvUMCO 'NO SHEETS,

BOILER CONTRACTOR

@--~ CETHAR VESSELS LIMITED


~
TIRUCHIRAPALLI- 620 001 , TAMILNADU

TITLE

SCALE JOB NO. SIZING DATA FOR ESP-BOILER


I ~.- ........

\ REVISION
NTS
DRAWING NO. BJ087-00-01 013
i
A
i

MlB/J/087 BJ087 00-01


MIS MEENAKSHI ENERGY PRIVATE LTD 2 X 300 MW
SELECTION PHILOSOPHY & CALCULATIONS
CETHAR VESSELS LIMITED EQUIPMENT : ESP
EIS NO: Q11

SI.No Description UOM 100% TMCR

Fuel Worst Coal

a) Gas Flow through ESP

1. Heating Value of Fuel kcal/kg 3380


I
2. Excess Air % 25

3. Airheater leakage % 15

4. Duct Leakage % 2

5. Gas temperature °C 130

6. Gas flow with 20 % Excess air & kg/hr 1482000

7. Airheater leakage & kg/hr 222300

8. Duct Leakage & kg/hr 29640

9. Additional gas flow for 25 % Excess air & kg/hr 55080

10. Flue gas density at SI.No:5 kg/m A 3 0.864

kg/hr 1789020
Total gas flow
11. & Nm3/sec 389.64

m3/sec 575.17

b) Inlet Dust Concentration

1. Fuel quantity burnt & kg/hr 240070

2. % of Ash in fuel 32.9

3. % of Ash entering ESP for design 80

4. Dust load @ Inlet of ESP & kg/hr 63186

Page 02 of 03
MIS MEENAKSHI ENERGY PRIVATE LTD 2 X 300 MW
SELECTION PHILOSOPHY & CALCLILATIONS
( CETHAR VESSelS UMITEO EQUIPMENT : ESP
EIS NO: 011

SI.No Description UOM 100 % TMCR

Fuel Worst Coal

5. Dust load @ Inlet of ESP


&' gms/sec 17552

6. IDC @ Inlet of ESP gms/Nm 3 45.05


&
c) ODC requirement

1. No off fields in service N -1

2. ODC mg/Nm 3 Not to exceed 50

N - Number of fields

Page 03 of 03