Sie sind auf Seite 1von 1

REPUBLIC OF THE PHILIPPINES

DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS


OFFICE OF THE BUILDING OFFICIAL
DAVAO CITY
ISSUANCE RECOMMENDED

HEAD ARCHITECTURAL DATE


SECTION
ISSUED BY:
01 01
A A-401.0 C E A-302.0 F G G' H H' J K L
3000 55350 100

9750 8000 8000 8000 2750 3450 2650 100 6375 6275 BUILDING OFFICIAL DATE
2775 3400 3575 1550 600 600
NOTE:

PROPERTY LINE FIREWALL FIREWALL This drawing is property of Archiglobal, Inc. whether the object for which they are
9 9 made is executed or not. Do not reproduce and disclose this drawing to any

ROOF OUTLINE ABOVE


unauthorized person without the written consent of Archiglobal, Inc.
FIRE RESERVE TANK UP

3000

3000
015 001
PUMP ROOM

Z-LOUVER
(VERIFY PLUMBING PLANS) Do not scale this drawing. All dimensions have to be verified on site. All

W11
+42.50m +41.50m STAIR 03 discrepancies have to be clarified with the Project Architect.
UGF OUTLINE
8 DS DS
8 All dimensions are in millimeters unless otherwise specified.

1625
RETAINING WALL 1.60m HIGH WALL 1.60m HIGH WALL
STAIR 2 All levels indicated are finish floor levels in meters unless otherwise specified.
STAIR 1 7'

3525
TELCO 009 PLINTH PLINTH PLINTH PLINTH

5025
TELCO RM-1 009

6250
EARTH FILL
RM-2 150 150 150

4625
D01

1500
001
D01 001 UP
UP GENSET/EE ROOM
DOMESTIC CISTERN TANK BELOW
+41.70m +42.20m

1225
001 003 +42.30m
PWD 27 36 D13 D03B D18A D18B
7 7

100

100
TOILET 1

200
925
D04
TRENCH DRAIN

100
CANOPY OUTLINE ABOVE

21500
W05

RETAINING WALL
DS

TRENCH DRAIN
TO BLDG. A TO BLDG. B

UGF OUTLINE

BUILDING-B LINE
+42.10m
6.00m DRIVEWAY
6000

6000
+42.10m
26 36 PARKING SLOTS
5075

+41.60m

TRENCH DRAIN
3400 1500

RAMP TO UGF RAMP FROM UGF


6 7 1
TRENCH DRAIN +42.10m
6
DRY
PROPERTY LINE

2550
GARBAGE

1.50m HIGH RAILING


+42.20m D02 100

SE 01 PE 01 +42.10m

6250
01 D02 100

OPEN ABOVE
A-400.0 WET

3100
GARBAGE
8250

+42.20m

BUILDING-B LINE
100 RETAINING WALL RETAINING WALL RETAINING WALL
ELEVATOR LOBBY
+41.70m
5
UGF OUTLINE

4
42700

EARTH FILL

01 8 01
A-303.0 A-301.0
6.00m DRIVEWAY
8000

RETAINING WALL

RETAINING WALL
DS
SEPTIC TANK ABOVE (VERIFY PLUMBING PLANS)

3 +41.60m
8000

RETAINING WALL

SID
EW
ALK

4 5

RAIN WATER
UP

2 TANK
DS
(VERIFY
PLUMBING
PLANS)
RETAINING WALL
RETAINING WALL
6200

RAMP
6 7

COMMERCIAL DEVELOPMENT
15 14
TO MAL
BAS L
EME
PAR NT
KING

7 3
50

BA
PA SE
RK ME
IN NT
G

UP
UP EX
DN IT

D03B 011

D
RETAINING WALL RETAINING WALL

R
O
P
8 A

-O
1

F
GH

F
9 4
+41.65m 6
11
2 10
5 2
FE 01 2 3
LOT 537-A 5
3
LOT 4-A
1875

K
L
P

A
A
R

W
UP

E
IN

ID
4

S
S
P
A
001 010

C
E
GAISANO GRAND MALL
+050.11m

LOT 537 B-1-A LOT 537 B-1-A

-OFF
RETAINING WALL

DROP
O
C
PA

EL
VE

EL

EV

S
EV

. -0.
ME

. -1.

88m.
NT

E
12m.
+047.35m

BR

R
IN
TA

IC
1 UN

F
FO

KS
G R plant
E E box
N E

L
R I
E S

A
plant
box
S I D E W plan
A t box
L K
G R
E E
N E plant
R I box
E S

12 1 plant
box

S I D E W plant
A G R box
L K E E
N E
R I
E S
ELEV.
-0.85m.
6 1

DR
ELEV.

OP
-1.0

-O
m. plan
t box

FF
CAN
JEEPN OPY
EY BAY
DROP
-OFF
LINE

plant F
8
G R box
E E OP-OF
S N E DR
I D E R I
E S

13
W plant
A L box
K

9
+038.00m

B
12 10
6250 6000 5450 800 11

3000 18500

01 BUILDING A
A B D E E' A-300.0

01 LOWER GROUND FLOOR PLAN KEY PLAN


A-200.0 SCALE 1:150m

- - -

REV. DATE DESCRIPTION


R.A.9266 Section 33 ARCHITECTURAL: STRUCTURAL:
SEAL ARCHIGLOBAL, INC.
JEMAR ENGINEERING PROJECT TITLE: APPROVED BY: DRAWING TITLE: SCALE: DATE: JULY 2017 SHEET NUMBER: REVISION:
Drawing and specifications and other SERVICES
contract documents signed, stamped or DESIGNED BY:
sealed, as instruments of service, are the ELECTRICAL: ELECTRONICS:
MICHAEL P. TORRES A PROPOSED 9-STOREY DYNASTY MANAGEMENT BUILDING A
A-200.0 R00
intellectual property and documents of the
architect, whether the object for which
JONATHAN A. VILLAFLOR VICTOR C. NAVARRO 1 : 150 A1 HHS
Unit 1501, 15th Floor, Appleone Equicom Tower, Mindanao Ave., cor. Biliran St., Cebu ARCHITECT they are made is executed or not, it shall MECHANICAL: FIRE PROTECTION:
AND DEVELOPMENT CORP.
Business Park, Cebu City, 6000 Philippines
REG. NO.: 11688 DATE : 06/27/1994
be unlawful for any person to duplicate or
to make copies of said documents for use
2KENS ENGINEERING & 2KENS ENGINEERING &
RESIDENTIAL CONDOMINIUM FLOOR PLAN

N
Telephone: (+63-32) 266-5575 CONSULTANCY SERVICES CONSULTANCY SERVICES DRAFTED BY:
in the repetition of and for other projects OWNER
Unit 07, Ground Floor Geson Bldg. D. Jakosalem St. Cebu City, 6000 Philippines PTR NO. : 5832853 DATE : 01/10/2017 EML/ARS
of building, whether executed partly in PLUMBING:
whole, without the written consent of
SITE DEVELOPMENT: 1 : 300 A3
Tele Fax: (+63-32) 255-4475 www.archiglobal.net LOCATION: BUHANGIN CABANTIAN- INDANGAN ROAD, DAVAO CITY ADDRESS: M.J. CUENCO AVE., CORNER HOLY NAME ST., CEBU CITY PROJECT CODE: P16_RES_345(A)
TIN : 167-004-094 architect or author of said documents. MARY CECILY B. SALERA

Das könnte Ihnen auch gefallen