LPV444.99.00210  LPV444.99.00310  LPV444.99.00120  LPV444.99.00320 

Product Name TL2300 Tungsten Lamp TL2350 Tungsten Lamp TL2310 LED Turbidimeter, ISO, 0 - TL2360 LED Turbidimeter, ISO, 0
Turbidimeter, EPA, 0 - 4000 NTU Turbidimeter, EPA, 0 - 10000 1000 NTU - 10000 NTU
NTU

USD Price Contact Hach Contact Hach Contact Hach Contact Hach

Availability Call for ship date Call for ship date Call for ship date Call for ship date

Description The new TL23 Series laboratory The new TL23 Series laboratory The new TL23 Series laboratory The new TL23 Series laboratory
turbidimeters blend trusted turbidimeters blend trusted turbidimeters blend trusted turbidimeters blend trusted
technology and improved technology and improved technology and improved technology and improved
features to simplify testing in the features to simplify testing in the features to simplify testing in the features to simplify testing in the
most demanding industrial and most demanding wastewater and most demanding wastewater and most demanding wastewater and
wastewater applications. industrial applications. industrial applications. industrial applications.

Hach’s new TL23 lab turbidimeter


brings a new face to the trusted
legacy 2100N and 2100AN
turbidimeters. It utilizes the same
optic bloc while delivering an
improved user experience with its
intuitive interface, which ties
perfectly to the rest of Hach’s
laboratory instruments.

Having the same optic bloc


means that you can replace your

https://www.hach.com/product.comparitor-compare.products.jsa 1/6
7/27/2017 Compare Products

LPV444.99.00210  LPV444.99.00310  LPV444.99.00120  LPV444.99.00320 


old 2100N/AN with a TL23
turbidity meter without having
tochange any of your standard
operating procedures.

Just like the legacy instrument,


the TL23 lab turbidimeter comes
in 4 different models:

•2100N is replaced by TL2300


(EPA, up to 4,000NTU)

•2100NIS is replaced by TL2310


(ISO, up to 1,000NTU)

•2100AN is replaced by TL2350


(EPA, up to 10,000NTU)

•2100ANIS is replaced by TL2360


(ISO, up to 10,000NTU)

With their ratio technology, the


TL23 labturbidimeters are ideal
for industrial and other samples
with a wide range ofturbidity. The
main bene t of TL23’s ratio
technology is that it helps to
overcome the interference from
large particles and color when
measuring turbidity.

For drinking water applications,


please refer to Hach’s new
TU5200 turbidimeter speci cally
developed for unprecedented
accuracy at low level turbidity
with new detection technology
that is identical with the one used
in Hach’s new TU5300 and
TU5400 online turbidimeters.

https://www.hach.com/product.comparitor-compare.products.jsa 2/6
7/27/2017 Compare Products

LPV444.99.00210  LPV444.99.00310  LPV444.99.00120  LPV444.99.00320 


Accuracy Ratio on: ±2% of reading plus 0.01 Ratio on: ±2% of reading plus 0.01 ±2% of reading plus 0.01 FNU/NTU FNU: ±2% of reading plus 0.01
NTU from 0 - 1000 NTU, ±5% of NTU from 0 - 1000 NTU, ±5% of from 0 - 1000 FNU/NTU FNU from 0 - 1000 FNU
reading from 1000 - 4000 NTU reading from 1000 - 4000 NTU
based on formazin primary ±10 % of reading from 4000 - FAU: ±10% of reading from 20 -
standard 10000 NTU 10000 NTU

Ratio off: ±2% of reading plus 0.01 Ratio off: ±2% of reading plus 0.01 NTU: ±2% of reading plus 0.01
NTU from 0 - 40 NTU NTU from 0 - 40 NTU NTU from 0 - 1000 NTU, ±5% of
reading from 1000 - 4000 NTU,
±10% of reading from 4000 -
10000 NTU

Air Purge Dry nitrogen or instrument grade Dry nitrogen or instrument grade Dry nitrogen or instrument grade Dry nitrogen or instrument grade
air (ANSI MC 11.1, 1975) air (ANSI MC 11.1, 1975) air (ANSI MC 11.1, 1975) air (ANSI MC 11.1, 1975)
0.1 scfm at 69 kPa (10 psig); 138 0.1 scfm at 69 kPa (10 psig); 138 0.1 scfm at 69 kPa (10 psig); 138 0.1 scfm at 69 kPa (10 psig); 138
kPa (20 psig) max kPa (20 psig) max kPa (20 psig) max kPa (20 psig) max
Hose barb connection for 1/8-inch Hose barb connection for 1/8-inch Hose barb connection for 1/8-inch Hose barb connection for 1/8-inch
tubing tubing tubing tubing

Certi cations CE, KC, RCM CE, KC, RCM CE, KC, RCM CE, KC, RCM

Communication USB USB USB USB

Data Logging 2000 total logs, includes reading 2000 total logs, includes reading 2000 total logs, includes reading 2000 total logs, includes reading
log, veri cation log and log, veri cation log and log, veri cation log and log, veri cation log and
calibration log calibration log calibration log calibration log

Dimensions (H x W x D) 153 mm x 395 mm x 305 mm 153 mm x 395 mm x 305 mm 153 mm x 395 mm x 305 mm 153 mm x 395 mm x 305 mm

Display 17.8 mm (7 in.) color touch screen 17.8 mm (7 in.) color touch screen 17.8 mm (7 in.) color touch screen 17.8 mm (7 in.) color touch screen

Interface 2 USB-A ports for USB ash drive, 2 USB-A ports for USB ash drive, 2 USB-A ports for USB ash drive, 2 USB-A ports for USB ash drive,
external printer, keyboard and external printer, keyboard and external printer, keyboard and external printer, keyboard and
barcode scanner barcode scanner barcode scanner barcode scanner

Light Source Tungsten lament lamp Tungsten lament lamp Light-emitting diode (LED) at 860 Light-emitting diode (LED) at 860
± 30 nm ± 30 nm

Measurement Method Nephelometric Nephelometric Nephelometric Nephelometric

Operating Temperature 0 - 40 °C 0 - 40 °C 0 - 40 °C 0 - 40 °C
Range

Power Requirements 3.4 A 3.4 A 3.4 A 3.4 A


(Amps)

Power Requirements (Hz) 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz

https://www.hach.com/product.comparitor-compare.products.jsa 3/6
7/27/2017 Compare Products

LPV444.99.00210  LPV444.99.00310  LPV444.99.00120  LPV444.99.00320 


Power Requirements 100 - 240 VAC 100 - 240 VAC 100 - 240 VAC 100 - 240 VAC
(Voltage)

Range NTU (Ratio on): 0 - 4000 NTU (Ratio on): 0 - 10000 auto NTU/FNU: 0 - 1000 FNU (Ratio on): 0 - 1000
decimal
NTU (Ratio off): 0 - 40 FNU (Ratio off): 0 - 40
NTU (Ratio off): 0 - 40
EBC (Ratio on): 0 - 980 FAU (auto range): 20 - 10000
EBC (Ratio on): 0 - 2450 auto
EBC (Ratio off): 0 - 9.8 decimal NTU (Ratio on): 0 - 10000 auto
decimal
EBC (Ratio off): 0 - 9.8
NTU (Ratio off): 0 - 40
Absorbance (auto range): 0 - 1.0
EBC (Ratio on): 0 - 2450 auto
Transmittance (%): 1.0 - 100 decimal

Degree (mg/L): 1 - 100 EBC (Ratio off): 0 - 9.8

Absorbance (auto range): 0 - 2.00

Transmittance (%): 1.0 - 100

Degree (mg/L): 0 - 100

Reading Modes Single, continuous, Rapidly Single, continuous, Rapidly Single, continuous, Rapidly Manual or auto range, signal
Settling Turbidity™, signal Settling Turbidity™, signal Settling Turbidity™, signal averaging on and adjustable or
averaging on or off, ratio on or off averaging on or off, ratio on or off averaging on or off off, ratio on or off

Regulatory Meets EPA Method 180.1 Meets EPA Method 180.1 Meets ISO 7027, DIN EN 27027, Meets ISO 7027, DIN EN 27027,
DIN 38404 and NFT 9033 DIN 38404 and NFT 9033

Repeatability ±1% of reading or 0.01 NTU, ±1% of reading or 0.01 NTU, ±1% of reading or 0.01 FNU/NTU, ±1% of reading or 0.01 FNU/NTU,
whichever is greater (under whichever is greater (under whichever is greater (under whichever is greater (under
reference conditions) reference conditions) reference conditions) reference conditions)

Response Time Signal averaging off: 6.8 seconds / Signal averaging off: 6.8 seconds / Signal averaging off: 6.8 seconds / Signal averaging off: 6.8 seconds /
Signal averaging on: 14 seconds Signal averaging on: 14 seconds Signal averaging on: 14 seconds Signal averaging on: 14 seconds
(when 10 measurements are used (when 10 measurements are used (when 10 measurements are used (when 10 measurements are used
to calculate the average) to calculate the average) to calculate the average) to calculate the average)

Sample Cell Compatibility Round cells 95 x 25 mm (3.74 x 1 Round cells 95 x 25 mm (3.74 x 1 Round cells 95 x 25 mm (3.74 x 1 Round cells 95 x 25 mm (3.74 x 1
in.) borosilicate glass with rubber- in.) borosilicate glass with rubber- in.) borosilicate glass with rubber- in.) borosilicate glass with rubber-
lined screw caps lined screw caps lined screw caps lined screw caps

Note: Smaller sample cells (less Note: Smaller sample cells (less Note: Smaller sample cells (less Note: Smaller sample cells (less
than 25 mm) can be used when a than 25 mm) can be used when a than 25 mm) can be used when a than 25 mm) can be used when a
cell adapter is used. cell adapter is used. cell adapter is used. cell adapter is used.

https://www.hach.com/product.comparitor-compare.products.jsa 4/6
7/27/2017 Compare Products

LPV444.99.00210  LPV444.99.00310  LPV444.99.00120  LPV444.99.00320 


Sample Requirements 25 mm sample cell: 20 mL 25 mm sample cell: 20 mL 25 mm sample cell: 20 mL 25 mm sample cell: 20 mL
minimum minimum minimum minimum
0 to 70 °C (32 to 158 °F) 0 to 70 °C (32 to 158 °F) 0 to 70 °C (32 to 158 °F) 0 to 70 °C (32 to 158 °F)

Stabilization Time Ratio on: 30 minutes after start- Ratio on: 30 minutes after start- Immediately Immediately
up up

Ratio off: 60 minutes after start- Ratio off: 60 minutes after start-
up up

Storage Conditions -20 to 60 °C -20 to 60 °C -20 to 60 °C -20 to 60 °C

Units NTU and EBC NTU, EBC, Abs (absorbance), %T FNU and NTU FNU, FAU, NTU, EBC, Abs
(% transmittance) and mg/L (absorbance), %T (%
transmittance) and mg/L

Weight 3.0 kg 3.0 kg 3.0 kg 3.0 kg

Accuracy 3 Absorbance: ±0.01 Abs from 0 - Absorbance: ±0.005 Abs from 0 -


0.5 Abs at 455 nm, ±2% Abs from 1 Abs at 860 nm
0.5 - 1 Abs at 455 nm
Transmittance: 0.12% T from 10 -
Transmittance: 2% T from 10 - 100% T at 860 nm
100% T at 455 nm

What's in the box? TL2300 Turbidimeter, silicone oil, TL2350 Turbidimeter, silicone oil, TL2310 Turbidimeter, silicone oil, TL2360 Turbidimeter, silicone oil,
oiling cloth, USEPA lter oiling cloth, USEPA lter oiling cloth, USEPA lter oiling cloth, USEPA lter
assembly, 1-inch sample cells (30 assembly, 1-inch sample cells (30 assembly, 1-inch sample cells (30 assembly, 1-inch sample cells (30
mL) with caps (6x), Gelex mL) with caps (6x), Gelex mL) with caps (6x), Gelex mL) with caps (6x), Gelex
secondary turbidity secondary turbidity secondary turbidity secondary turbidity
standardization kit, Stablcal standardization kit, Stablcal standardization kit, Stablcal standardization kit, Stablcal
calibration kit, power supply, calibration kit, power supply, calibration kit, power supply, calibration kit, power supply,
power cord, dust cover power cord, dust cover power cord, dust cover power cord, dust cover

https://www.hach.com/product.comparitor-compare.products.jsa 5/6