1. Don’t put hands inside machine during operation. 2. Don’t touch the switch with wet hands. 3. Make sure that the machine is cleaned after the use. EXPERIMENT NAME: To determine workability by compaction factor INSTRUMENT NAME : Compaction Factor Apparatus Stock Entry Page No.: Equipment Price:
Close the door of all hopper
Pour the concrete in hopper A
Open the door of hopper A and
allow concrete to fall in hopper B
Open the door of hopper B and
allow the concrete to fall in cylinder (C)
Weight the concrete in cylinder (C)
Clean the apparatus
Do’s and Don’ts
1. Keep the hoppers and cylinders cleaned and oiled.
2. Make sure that the machine is cleaned after the use.
EXPERIMENT NAME: To determine workability by Flow test.
INSTRUMENT NAME : Flow table Apparatus
Stock Entry Page No.: Equipment Price:
Place the slump cone on the table
Pour the concrete (added with
superplasticizers) into the slump cone and lift the cone.
Allow the concrete to flow on the
table
Measure the diameter of the flow
of concrete in all direction.
Remove the concrete and clean the
apparatus
Do’s and Don’ts
1. Mix the concrete containing superplasticizers using gloves.
2. Make sure that the machine is cleaned after the use.
EXPERIMENT NAME : To determine workability by slump test
EQUIPMENT NAME : Slump Cone Apparatus
Stock Entry Page No.: Equipment Price:
Attach the slump cone to the base
plate and tighten it.
Pour the concrete in slump cone in
three layers while tamping
Remove the excess concrete from
the top surface using trimmer
Lift up the slump cone and allow
concrete to subsidize
Measure the subsidence
Clean the apparatus
Do’s and Don’ts
1. Keep the slump cone oiled before pouring the concrete.
2 Make sure that the machine is cleaned after the use.
EXPERIMENT NAME : To determine the fineness modulus
INSTRUMENT NAME : Sieve set
Stock Entry Page No.: Equipment Price:
Arrange the sieves in order
Put the material in top sieve.
Shake the sieve for 5 min. In mechanical sieve shaker
Take the weight of material in each sieve.
Clean the all sieve
Do’s and Don’ts
1. Arrange the sieve in correct order.
2. Make sure that the machine is cleaned after the use.
EXPERIMENT NAME : Sieve Analysis
INSTRUMENT NAME : Sieve Shaker
Stock Entry Page No.: Equipment Price:
Place the sieve on sieve shaker and
bolt it.
Set the timer as for 5 min. and than
start the machine
Switch off the machine and remove
the sieve
Clean the apparatus
Do’s and Don’ts
1. Don’t touch the switch with wet hands.
2. Don’ t touch the siever in working condition.
3. Place the sieve in correct order on siever machine.
4. Make sure that the machine is cleaned after the use