Sie sind auf Seite 1von 7

Figure 3.1. Photograph showing views of the Building Gate Cabin No.1 of IOCL Turbhe Plant.

(a) (b)

(c) (d)
Figure 3.2. Photographs showing distress in the columns of the Building Gate Cabin No.1 of
IOCL Turbhe Plant.
(a) (b)

(c)
Figure 3.3. Photographs showing distress in the beams of the Building Gate Cabin No.1 of
IOCL Turbhe Plant.
(a) (b)
Figure 3.4. Photographs showing distress in the slabs of the Building Gate Cabin No.1 of
IOCL Turbhe Plant.
NDT PHOTOS
(a)
Figure 3.5. Photographs showing Rebound Hammer Tests of Columns of the Building Gate
Cabin No.1 of IOCL Turbhe Plant.

(a) (b)
Figure 3.6. Photographs showing Rebound Hammer Tests of Slabs of the Building Gate Cabin
No.1 of IOCL Turbhe Plant.
(a)
Figure 3.7. Photographs showing Ultrasonic Pulse Velocity Tests of Columns of the Building
Gate Cabin No.1 of IOCL Turbhe Plant.

(a) (b)
Figure 3.8. Photographs showing Ultrasonic Pulse Velocity Tests of Slabs of the Building Gate
Cabin No.1 of IOCL Turbhe Plant.